Registers refreshed 2026-11-08.See refresh dates
Germany

Bayer Aktiengesellschaft Process and Plant Safety - Safety

Gebäude B407, 51368, Leverkusen, Germany

DAKKS D-PL-20963-01-00DAKKS D-PL-20963-01-01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
14
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 14 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO7
ISO 1523Determination of flash point - Closed cup equilibrium method
ISO 2719Determination of flash point - Pensky-Martens closed cup method
ISO 3679Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester
ISO 9038Determination of sustained combustibility of liquids
ISO 13736Determination of flash point - Abel closed-cup method
ISO/IEC 80079-20-1Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
ISO/IEC 80079-20-2Explosive atmospheres - Part 20-2: Material characteristics - Combustible dusts test methods
EN 14034 series4
EN 14034-1
EN 14034-2
EN 14034-3
EN 14034-4
Other standards3
DIN 51007-1
EN 15188
EN 17077

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-20963-01-00

View scope

Accredited scope, certificate D-PL-20963-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-20963-01-01

View scope

Accredited scope, certificate D-PL-20963-01-01

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001chemischen Produkten; Stoffen und Stoffgemischen-
2DIN EN 17077; UN - Manual; DIN EN ISO 13736; DIN EN ISO 2719chemischen Produkten in Mischung mit Luft oder anderen oxidierenden Stoffen; Staubschichten; flüssige Stoffe; Feststoffe-
3DIN EN ISO 3679; DIN EN ISO 1523; UN - Manual; DIN EN ISO 9038; DIN EN ISO/IEC 80079 -20 -2; DIN EN 14034 -3; DIN EN 14034 -1Flüssigkeiten; Staub/Luft-Gemische; brennbare Stäube-
4DIN EN 14034 -2; DIN EN 14034 -4; DIN EN ISO/IEC 80079 -20 -2; UN - Manual; DIN EN ISO/IEC 80079 -20 -2; DIN EN 15188; VDI 2263Staub/Luft-Gemischen; pyrophore feste Stoffe; pyrophore flüssige Stoffe; brennbare Stäube; Staubschüttungen; Schüttgütern-
5UN - Manual 2023; DIN EN ISO/IEC 80079 -20 -1 2020-09; DIN EN ISO/IEC 80079 -20 -2 2016-12 Berichtigung 1 2018-01; DIN 51007 -1 2024-08; EG Verordnung Nr. 440/2008 2023-03; SOP -DTA -M-1163 -0003 2023-07; SOP -DTA -M-1152 -0005 2023-06; SOP -DTA -M-1162 -0008 2023-01Stoffe und Stoff - gemischen-
6UN - Manual; DIN 51007 -1; VDI 2263kondensierter Stoffe; Schüttgütern-
7UN - Manual--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Gebäude B407, Leverkusen, 51368, DE

51.03247, 6.98812

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.