FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United Kingdom

Precision Analysis (North West)

Unit 3A Olympic Way, Sefton Business Park, Aintree, L30 1RD, Merseyside, United Kingdom

UKAS|1763ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
4
Standards
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Precision Analysis (North West)?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
1763Active

Accredited standards

8

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
As written on the certificate · Line 3 (UKAS 1763)

BS EN ISO 15213-2:2023 with in- house confirmation using BioMerieux API rapid ID 32; BS EN ISO 21528-2:2017; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021 Confirmation using Oxoid Staphytect plus kit or Pro-Lab Diagnostics Staph Latex kit Total aerobic colony count at 30; BS EN ISO 4833-1:2013/Amd 1:2022 Moulds and Yeasts A2/13

ISO 6888-1Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 1: Method using Baird-Parker agar medium
As written on the certificate · Line 3 (UKAS 1763)

BS EN ISO 15213-2:2023 with in- house confirmation using BioMerieux API rapid ID 32; BS EN ISO 21528-2:2017; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021 Confirmation using Oxoid Staphytect plus kit or Pro-Lab Diagnostics Staph Latex kit Total aerobic colony count at 30; BS EN ISO 4833-1:2013/Amd 1:2022 Moulds and Yeasts A2/13

ISO 6888-3Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 3: Detection and MPN technique for low numbers
As written on the certificate · Line 2 (UKAS 1763)

BS EN ISO 21872- 1:2017; BS EN ISO 21528- 1:2017; BS EN ISO 6888- 3:2003; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 21872- 1:2017

ISO 11290-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 2: Enumeration method
As written on the certificate · Line 3 (UKAS 1763)

BS EN ISO 15213-2:2023 with in- house confirmation using BioMerieux API rapid ID 32; BS EN ISO 21528-2:2017; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021 Confirmation using Oxoid Staphytect plus kit or Pro-Lab Diagnostics Staph Latex kit Total aerobic colony count at 30; BS EN ISO 4833-1:2013/Amd 1:2022 Moulds and Yeasts A2/13

ISO 15213-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Clostridium spp. - Part 2: Enumeration of Clostridium perfringens by colony-count technique
As written on the certificate · Line 3 (UKAS 1763)

BS EN ISO 15213-2:2023 with in- house confirmation using BioMerieux API rapid ID 32; BS EN ISO 21528-2:2017; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021 Confirmation using Oxoid Staphytect plus kit or Pro-Lab Diagnostics Staph Latex kit Total aerobic colony count at 30; BS EN ISO 4833-1:2013/Amd 1:2022 Moulds and Yeasts A2/13

ISO 21528-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 1: Detection of Enterobacteriaceae
As written on the certificate · Line 2 (UKAS 1763)

BS EN ISO 21872- 1:2017; BS EN ISO 21528- 1:2017; BS EN ISO 6888- 3:2003; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 21872- 1:2017

ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique
As written on the certificate · Line 3 (UKAS 1763)

BS EN ISO 15213-2:2023 with in- house confirmation using BioMerieux API rapid ID 32; BS EN ISO 21528-2:2017; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021 Confirmation using Oxoid Staphytect plus kit or Pro-Lab Diagnostics Staph Latex kit Total aerobic colony count at 30; BS EN ISO 4833-1:2013/Amd 1:2022 Moulds and Yeasts A2/13

ISO 21872-1Microbiology of the food chain - Horizontal method for the determination of Vibrio spp. - Part 1: Detection of potentially enteropathogenic Vibrio parahaemolyticus, Vibrio cholerae and Vibrio vulnificus
As written on the certificate · Line 2 (UKAS 1763)

BS EN ISO 21872- 1:2017; BS EN ISO 21528- 1:2017; BS EN ISO 6888- 3:2003; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 21872- 1:2017

Scope as published by UKAS

4 lines
UKAS

ISO/IEC 17025

Active

1763

View scope

Accredited scope, certificate 1763

LineDisciplineMethodMatrixRange
1Chemical TestingBS 4401; ISO/IEC 17025:2017; IEC 17025Food products-
2Biological TestingBS EN ISO 21872- 1:2017; BS EN ISO 21528- 1:2017; BS EN ISO 6888- 3:2003; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 21872- 1:2017Food products-
3Biological TestingBS EN ISO 15213-2:2023 with in- house confirmation using BioMerieux API rapid ID 32; BS EN ISO 21528-2:2017; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021 Confirmation using Oxoid Staphytect plus kit or Pro-Lab Diagnostics Staph Latex kit Total aerobic colony count at 30; BS EN ISO 4833-1:2013/Amd 1:2022 Moulds and Yeasts A2/13Food products-
4Biological TestingISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; in-house method usingDrinking water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Unit 3A Olympic Way, Sefton Business Park, Aintree, Merseyside, L30 1RD, GB

53.49536, -2.97394

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.