Dytran Instruments
21592 Marilla St, 91311, Chatsworth, CA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2672.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 0.01 to 100 V |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2672.01) Revised 09/29/2025 Page 2 of 3
II. Mechanical
Parameter/Equipment
Range5
CMC2, 4, 6 (±)
Comments
Acceleration
Sensitivity/Frequency
Response – Measure
(1 to 20) Hz
(20 to 100) Hz
(100 to 2500) Hz
(2500 to 10 000) Hz
0.9 %
1.8 %
1.7 %
3.0 %
Custom calibration
system
Acceleration Sensitivity
Deviation Due to
Temperature – Measure
(24 to 316) °C @ 100 Hz, 1 g
5.0 %
Custom calibration
system
Transverse Sensitivity –
Measure
328 Hz @ 1 g
3.7 %
Custom calibration
system
Acoustic Pressure –
Measure
160 dB @ 1000 Hz
1.3 %
Comparison to
standard microphone
Static Force – Measure
1.876 lbf
2.840 lbf
3.290 lbf
4.170 lbf
(10 to 500) lbf
(500 to 1000) lbf
(1000 to 10 000) lbf
(10 000 to 100 000) lbf
0.7 %
1.0 %
1.3 %
1.1 %
1.2 %
Dead weights
Ring dynamometer,
strain gage, load cell
Ring dynamometer
load cell
Shock – Measure
(100 to 5000) g
(5000 to 20 000) g
(20 000 to 50 000) g
(50 000 to 100 000) g
3.0 %
4.4 %
5.2 %
6.0 %
Load cell
Hopkinson bar
Static Pressure –
Measure
(5 to 100) PSIG
(100 to 10 000) PSIG
2.5 %
1.1 %
Back-to-back
comparison in
pressure pump
Impulse Force –
Measure
(100 to 1000) lbf
(1000 to 5000) lbf
3.8 %
1.0 %
Load cell | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2672.01) Revised 09/29/2025 Page 3 of 3
Parameter/Equipment
Range5
CMC2, 4, 6 (±)
Comments
Acceleration Amplitude
Linearity Vibration –
Measure
100 Hz or 400 Hz, (1 to 20) g
1.7 %
Custom calibration
system
Angular Rate
(50 to 250) °/s
2.6 %
Robotic arm
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured values in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
4 In the statement of CMC, % denotes percentage of reading.
5 In the statements of Parameter and Range, g represents the gravitational acceleration.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges
indicated for the listed measurement parameter.
7 This scope contains measurands of sensor/transducer with input expression. The output measurand is
omitted and can be expressed in the form of sensitivity, for example, mV/g, pC/g, etc.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Micro Quality CalibrationChatsworth, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Primary InstrumentsChatsworth, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Los AngelesPanorama City, CA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Fischer Custom CommunicationsTorrance, CA · ~53 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - SANTA FE SPRINGSSanta Fe Springs, CA · ~60 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.