SIMCO Electronics - Los Angeles
13731 Saticoy Street, 91402, Panorama City, CA, United States
Visit website- Scope lines
- 28
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 28 scope lines.
A2LA certificate 1395.05 · 28 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 2 of 27
Parameter/Equipment
Range4
CMC2, 5, 8 (±)
Comments
Optical Flats/Parallels –
Flatness
Parallelism
Thickness
Up to 4 in
Up to 4 in
Up to 1 in
3.6 µin
2.4 µin
4.8 µin
Van Keuren optical flat,
gage blocks
Federal 130B-4 gage block
comparator
Federal 130B-4 gage block
comparator, gage blocks
Length Standards
Up to 60 in
0.000 05 % + 22 µin
SIP MUL 4000, Renishaw
XL-80 laser system, gage
blocks
Micrometers3 –
Flatness3
Parallelism3
Up to 48 in
Up to 48 in
Up to 48 in
(11 + 4.8L) µin
5.6 µin
9.6 µin
Gage blocks
Optical flats
Optical parallels
Height Gages3
Up to 40 in
(69 + 1.5L) µin
Gage blocks, surface plate
Depth Gages3
Up to 12 in
(38 + 0.63L) µin
Gage blocks, surface plate
Calipers3
Up to 5 in
(5 to 48) in
(48 to 72) in
(290 + 10L) µin
(540 + 6.4L) µin
(600 + 6.4L) µin
Gage blocks
Indicators3
Up to 6 in
(37 + 0.67L) µin
Gage blocks, surface plate
Tapes & Rules
Up to 60 in
(36 + 4.9L) µin
SIP MUL 4000, Renishaw
XL-80 laser system
Glass Scales
Up to 24 in
0.000 05 % + 32 µin
SIP MUL 4000, gage
blocks, Renishaw XL-80
laser system | to 4 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 3 of 27
Parameter/Equipment
Range4
CMC2, 5, 8 (±)
Comments
Plain Ring Gages
(0.25 to 4) in
(15 + 2.2L) µin
Gage blocks, Pratt &
Whitney universal
SupermicTM
Pin Gages
(0.005 to 4) in
(15 + 4.8L) µin
(0.38 + 0.0048L) µm
Pratt & Whitney universal
SupermicTM, gage blocks
Thread Plug Gages –
Major Diameter
Pitch Diameter
Up to 12 in
Up to 12 in
(36 + 4.8L) µin
(0.92 + 0.0048L) µm
(73 + 4.8L) µin
(1.8 + 0.0048L) µm
Pratt & Whitney universal
Supermic
TM w/ gage
blocks & thread wires
Crimper Tools
Up to 2 in
0.000 32 in
Optical comparator
Levels
Up to 0.015 in
11 µin/ft
Sine plate & gage blocks
Linear Indicators,
Comparators
Up to 4 in
(5.5 + 6.1L) µin
Gage blocks, Renishaw XL-
80 laser system
V Blocks –
Parallelism
Squareness
(0 to 0.1) in
(0 to 0.1) in
15 µin
83 µin
Gage blocks, MU-checker,
cylindrical square
Surface Plates3 –
Flatness
Repeatability
Up to 12 in
Up to 180 in DL
Up to 0.001 in
9.9 µin
(42 + 0.41DL) µin
36 µin
Gage blocks, MU-checker
Mahr leveling system
DL = diagonal length
measured in inches
Repeat-o-meter | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 4 of 27
Parameter/Equipment
Range4
CMC2, 5, 8 (±)
Comments
Precision Balls
Up to 2 in
(2 to 4) in
24 µin
17 µin
MU checker, universal
supermic & gage blocks
Renishaw XL-80 laser
system
Parallels
Up to 24 in
27 µin
MU checker, granite
parallels & gage blocks
Precision Squares
Up to 24 in
26 µin
Master square, MU
checker, true square
II. Dimensional Testing/Calibration
1
Parameter/Equipment
Range
CMC2 (±)
Comments
Length – 3 Dimensional6
X, Y, & Z
Up to 56 in
350 µin
Mitutoyo B231 CMM
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Voltage – Generate3
± (0 to 220) mV
± (0.22 to 2.2) V
± (2.2 to 11) V
± (11 to 22) V
± (22 to 220) V
± (220 to 1100) V
(1000 to 60 000) V
0.0008 % + 0.68 µV
0.0007 % + 1.6 µV
0.0007 % + 12 µV
0.0007 % + 14 µV
0.0008 % + 140 µV
0.0009 % + 1400 µV
0.12 % + 710 µV
Fluke 5700A-03
Ross VD60-6.2-B-K-AC,
DMM, high voltage source | to 2 in |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 5 of 27
Parameter/Equipment
Range CMC2, 7, 8 (±) Comments
DC Voltage – Measure3
± (0 to 100) mV
± (0.1 to 1) V
± (1 to 10) V
± (10 to 100) V
± (100 to 1000) V*
(1000 to 60 000) V
0.000 58 % + 0.056 µV
0.0004 % + 0.12 µV
0.0004 % + 0.74 µV
0.0006 % + 16 µV
0.0006 % + 0.57 mV*
0.12 %
HP 3458A OPT-2
*add 12(Vin /1000)2 1xE-6
to all Vin > 100
Ross VD60-6.2-B-K-AC
DC Current – Generate3
Clamp Meters
± (0 to 220) µA
± (0.22 to 2.2) mA
± (2.2 to 22) mA
± (22 to 220) mA
± (0.22 to 2.2) A
± (2.2 to 11) A
(11 to 20.5) A
(11 to 20) A
(20 to 100) A
(> 20.5 to < 150) A
(150 to 1025) A
0.005 % + 8.2 nA
0.005 % + 43 nA
0.005 % + 410 nA
0.006 % + 4.4 µA
0.008 % + 74 µA
0.036 % + 530 µA
0.078 % + 1300 µA
0.069 % + 3 mA
0.053 % + 3 mA
0.6 % + 0.17 A
0.6 % + 0.88 A
Fluke 5700A-03/5725A
Fluke 5520A/SC600
Valhalla 2555A
Fluke 5500A/coil &
5520A/SC600
DC Current – Measure3
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 2) A
(2 to 20) A
(20 to 100) A
0.04 % + 3 pA
0.0045 % + 0.018 nA
0.0022 % + 0.58 nA
0.0022 % + 0.072 nA
0.0021 % + 0.62 nA
0.0021 % + 3.1 nA
0.0035 % + 0.075 µA
0.011 % + 1.8 µA
0.000 78 A
0.0041 A
0.071A
HP 3458A OPT-2
Valhalla 2575A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 6 of 27
Parameter/Equipment
Range CMC2, 7, 8 (±) Comments
Resistance – Generate3
Fixed Points
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 99) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.999 99) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(0.33 to 1.1) GΩ
0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
100 MΩ
1 GΩ
31 µΩ/Ω + 0.077 Ω
23 µΩ/Ω + 1.9 mΩ
22 µΩ/Ω + 2.2 mΩ
22 µΩ/Ω + 4.4 mΩ
22 µΩ/Ω + 18 mΩ
22 µΩ/Ω + 44 mΩ
22 µΩ/Ω + 140 mΩ
22 µΩ/Ω + 0.43 Ω
22 µΩ/Ω + 1.3 Ω
25 µΩ/Ω + 7.7 Ω
25 µΩ/Ω + 22 Ω
47 µΩ/Ω + 34 Ω
0.01 % + 770 Ω
0.019 % + 3.7 kΩ
0.039 % + 35 kΩ
0.23 % + 80 kΩ
1.2 % + 2.6 MΩ
0.0058 %
0.012 % + 0.029 µΩ
0.012 % + 0.37 µΩ
0.012 % + 2.8
µΩ
54 µΩ
95 µΩ/Ω + 18 µΩ
95 µΩ/Ω + 31 µΩ
28 µΩ/Ω + 46 µΩ
27 µΩ/Ω + 82 µΩ
17 µΩ/Ω + 290 µΩ
17 µΩ/Ω + 560 µΩ
13 µΩ/Ω + 2.3 mΩ
13 µΩ/Ω + 6 mΩ
12 µΩ/Ω + 37 mΩ
12 µΩ/Ω + 51 mΩ
14 µΩ/Ω + 640 mΩ
14 µΩ/Ω + 1200 mΩ
20 µΩ/Ω + 6.2 Ω
21 µΩ/Ω + 12 Ω
40 µΩ/Ω + 190 Ω
47 µΩ/Ω + 360 Ω
110 µΩ/Ω + 2.7 kΩ
0.26 % + 0.081 MΩ
0.26 % + 0.72 MΩ
Fluke
5522A/SC1100
Standard resistors
Guildline, L&N
Fluke 5700A-03
Keithley 5155 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 7 of 27
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(100 to 1000) MΩ
25 µΩ/Ω + 50 µΩ
21 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 5 mΩ
12 µΩ/Ω + 50 mΩ
20 µΩ/Ω + 2 Ω
59 µΩ/Ω + 100 Ω
0.060 MΩ + 1 kΩ
0.079 MΩ + 10 kΩ
HP 3458A OPT-002
Capacitance – Generate3
(0.220 to < 1.1) nF
(1.1 to < 3.3) nF
(3.3 to < 11) nF
(11 to < 33) nF
(33 to < 110) nF
(110 to < 330) nF
(0.33 to < 1.1) µF
(1.1 to < 3.3) µF
(3.3 to < 11) µF
(11 to < 33) µF
(33 to < 110) µF
(110 to < 330) µF
(0.33 to < 1.1) mF
(1.1 to < 3.3) mF
(3.3 to < 11) mF
(11 to < 33) mF
(33 to < 110) mF
0.39 % + 7.8 pF
0.39 % + 7.9 pF
0.19 % + 9.7 pF
0.19 % + 81 pF
0.19 % + 120 pF
0.19 % + 250 pF
0.19 % + 0.86 nF
0.19 % + 2.7 nF
0.19 % + 9.7 nF
0.31 % + 33 nF
0.35 % + 100 nF
0.35 % + 240 nF
0.35 % + 0.80 µF
0.35 % + 2.4 µF
0.35 % + 8.3 µF
0.58 % + 26 µF
0.85 % + 81 µF
Fluke 5522A-SC1100
Electrical Simulation of
Thermocouples Indicating
Devices – Generate &
Measure
3
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.42 °C
0.23 °C
0.17 °C
0.21 °C
0.23 °C
0.25 °C
0.21 °C
0.17 °C
0.19 °C
0.26 °C
0.31 °C
0.2 °C
0.19 °C
0.26 °C
0.36 °C
0.53 °C
0.23 °C
0.18 °C
0.17 °C
Fluke 5520A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 8 of 27
Parameter/Equipment
Range4 CMC2, 7 (±) Comments
Oscilloscopes3 –
DC Signal:
Into 50 Ω
Into 1 MΩ
Level Sine Wave :
50 kHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
Square Wave:
50 Ω, 10 Hz to 10 kHz
1 MΩ, 10 Hz to 1 kHz
1 MΩ, (1 to 10) kHz
Time Marker Output:
Into 50 Ω
Pulse Rise Time
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 6.599) V
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 10.999) V
(11 to 130) V
5 mV to 5.5 V
5 mV to 5.5 V
5 mV to 5.5 V
5 mV to 5.5 V
4 mV to 3.5 V
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 6.599) V
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.199 V
(2.2 to 10.999) V
(11 to 130) V
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 10.999) V
(11 to 130) V
(2 to 5) ns
10 ns
(20 to 50) ns
100 ns to 20 ms
1 kHz to 2 MHz
(200 to 300) ps
(2 to 10) MHz
(200 to 350) ps
0.012 mV + 40 µV
0.014 mV + 40 µV
0.000 16 V + 40 µV
0.002 V + 40 µV
0.013 mV + 40 µV
0.019 mV + 40 µV
0.000 27 V + 40 µV
0.002 V + 40 µV
0.014 V + 40 µV
1.5 % + 0.3 mV
2.2 % + 0.4 mV
2.7 % + 0.4 mV
4.8 % + 0.4 mV
4.8 % + 0.4 mV
0.19 % + 40 µV
0.19 % + 40 µV
0.19 % + 40 µV
0.19 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
0.078 % + 40 µV
16 parts in 10
6 s
6.3 parts in 106 s
5.5 parts in 106 s
11 parts in 106 s
240 ps
270 ps
Fluke
5522A/SC1100 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 9 of 27
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Generate3
(0.22 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
0.055 % + 5 µV
0.021 % + 5 µV
0.011 % + 5 µV
0.037 % + 5.4 µV
0.085 % + 8 µV
0.11 % + 15 µV
0.17 % + 27 µV
0.34 % + 28 µV
0.055 % + 8 µV
0.021 % + 7 µV
0.011 % + 12 µV
0.037 % + 12 µV
0.085 % + 11 µV
0.11 % + 20 µV
0.17 % + 32 µV
0.34 % + 42 µV
0.055 % + 41 µV
0.021 % + 18 µV
0.011 % + 11 µV
0.032 % + 17 µV
0.085 % + 41 µV
0.11 % + 55 µV
0.17 % + 78 µV
0.34 % + 190 µV
0.05 % + 140 µV
0.016 % + 49 µV
0.0075 % + 43 µV
0.012 % + 78 µV
0.025 % + 170 µV
0.043 % + 330 µV
0.11 % + 560 µV
0.22 % + 1700 µV
0.05 % + 1400 µV
0.016 % + 540 µV
0.0075 % + 480 µV
0.012 % + 910 µV
0.025 % + 1600 µV
0.05 % + 3800 µV
0.13 % + 7700 µV
0.27 % + 21 000 µV
0.05 % + 48 mV
0.016 % + 6.5 mV
0.008 % + 6.1 mV
0.022 % + 12 mV
Fluke 5700A-03
& 5725A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 10 of 27
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Generate3
(cont)
(22 to 220) V
(220 to 250) V
(220 to 1000) V
(220 to 750) V
(1000 to 40 000) V
(50 to 100) kHz
(15 to 50) Hz
(0.04 to 1) kHz
(≥ 4 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
(50 to 60) Hz
0.05 % + 18 mV
0.04 % + 42 mV
0.008 % + 44 mV
0.017 % + 110 mV
0.06 % + 110 mV
0.06 % + 79 mV
0.23 % + 300 mV
0.59 % + 2.2 mV
Fluke 5700A-03 & 5725A
Ross VD60-6.2-B-K-AC,
DMM, high voltage source
Wideband AC Voltage –
Generate3
Amplitude:
(0.3 to 1.1) mV
(1.1 to 3) mV
(3 to 11) mV
(11 to 33) mV
(33 to 110) mV
(110 to 330) mV
(0.3 to 1.1) V
(1.1 to 3.5) V
Flatness Relative to
1 kHz Reference:
0.3 mV to 3.5 V
(0.03 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 12) kHz
(12 to 120) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
0.8 % + 2.4 µV
0.7 % + 9.8 µV
0.7 % + 15 µV
0.6 % + 23 µV
0.6 % + 55 µV
0.5 % + 130 µV
0.5 % + 460 µV
0.4 % + 680 µV
0.31 % + 5.8 µV
0.11 % + 5.8 µV
0.1 % + 5.8 µV
0.11 % + 5.8 µV
0.1 % + 5.8 µV
0.11 % + 6.7 µV
0.11 % + 6.7 µV
0.22 % + 6.7 µV
0.42 % + 6.7 µV
1 % + 6.7 µV
Fluke 5700A-03 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 11 of 27
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1000 to 40 000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(50 to 60) Hz
0.048 % + 3 µV
0.037 % + 1.1 µV
0.048 % + 1.1 µV
0.12 % + 1.1 µV
0.61 % + 1.1 µV
4.7 % + 2 µV
0.011 % + 4 µV
0.0091 % + 2 µV
0.017 % + 2 µV
0.036 % + 2 µV
0.096 % + 2 µV
0.76 % + 10 µV
1.2 % + 10 µV
0.0083 % + 40 µV
0.0083 % + 20 µV
0.016 % + 20 µV
0.035 % + 20 µV
0.093 % + 20 µV
0.35 % + 0.1 mV
1.2 % + 0.1 mV
0.0085 % + 0.4 mV
0.0084 % + 0.2 mV
0.016 % + 0.2 mV
0.035 % + 0.2 mV
0.093 % + 0.2 mV
0.35 % + 1.0 mV
1.2 % + 1.0 mV
0.023 % + 4 mV
0.023 % + 2 mV
0.023 % + 2 mV
0.041 % + 2 mV
0.14 % + 2 mV
0.046 % + 40 mV
0.046 % + 20 mV
0.069 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
0.59 % + 3.9 mV
HP 3458A OPT-002
Ross VD60-6.2-B-K-
AC | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 12 of 27
Parameter/Range
Frequency
CMC2, 7, 8 (±)
Comments
AC Voltage Flatness –
Measure3
Relative to 1 kHz
Reference:
3 V
(10 to 100) Hz
(0.1 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 8) MHz
(8 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(50 to 70) MHz
(70 to 80) MHz
(80 to 100) MHz
0.21 %
0.092 %
0.13 %
0.13 %
0.22 %
0.23 %
0.24 %
0.30 %
0.67 %
0.43 %
0.49 %
Thermal converters &
HP 3458A
AC Current3 – Generate
(9 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(20 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.07 % + 25 nA
0.035 % + 20 nA
0.014 % + 17 nA
0.06 % + 40 nA
0.16 % + 80 nA
0.07 % + 53 nA
0.035 % + 54 nA
0.014 % + 54 nA
0.06 % + 400 nA
0.16 % + 800 nA
0.07 % + 0.98 µA
0.035 % + 0.82 µA
0.014 % + 0.81 µA
0.06 % + 4.1 µA
0.16 % + 8 µA
0.07 % + 11 µA
0.035 % + 7.9 µA
0.014 % + 7.9 µA
0.06 % + 41 µA
0.16 % + 80 µA
0.065 % + 87 µA
0.075 % + 110 µA
0.85 % + 190 µA
Fluke 5700A-03/
5725A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 13 of 27
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Current3 – Generate
(cont)
(2.2 to 11) A
(2 to 20) A
Clamp Meters:
(> 20.5 to < 150) A
(150 to 1025) A
(> 20.5 to < 150) A
(150 to 1025) A
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
60 Hz
(45 to 65) Hz
(> 65 to 440) Hz
0.046 % + 710 µA
0.095 % + 780 µA
0.36 % + 1000 µA
0.71 % + 0.6 A
0.68 % + 0.3 A
0.67 % + 1.2 A
1.2 % + 0.3 A
1.2 % + 1.2 A
Fluke 5700A-03/
5725A
Valhalla 2555A
Fluke 5500A/coil &
5520A/SC600
LCOMP ON
AC Current – Measure3
10 µA
(> 10 to 100) µA
(> 0.1 to 1) mA
(> 1 to 10) mA
(> 10 to 100) mA
(> 0.1 to 1) A
(> 1 to 2) A
(> 2 to 20) A
(> 20 to 100) A
(0.045 to 1) kHz
(0.045 to 5) kHz
(45 to 1000) Hz
0.067 % + 0.58 nA
0.067 % + 3.6 nA
0.063 % + 2.3 nA
0.063 % + 660 nA
0.063 % + 170 nA
0.1 % + 67 µA
0.12 % + 0.2 mA
0.13 % + 2 mA
0.12 % + 2 mA
HP 3458A OPT-002
Valhalla 2575A
IV. Electrical – RF/Microwave
Parameter/Range
Frequency CMC2, 10 (±) Comments
RF Power – Generate
(13 to -5) dB
(-20 to -58) dB
(-50 to -80) dB
(26 to > 20) dBm
(20 to -10) dBm
(-10 to -90) dBm
200 Hz to 80 MHz
250 kHz to 40 GHz
0.054 dB
0.12 dB
0.26 dB
1.2 dB
0.95 dB
1.2 dB
HP 3335A
Agilent E8257D | ||
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 14 of 27
Parameter/Range
Frequency CMC2, 8, 10 (±) Comments
RF Power – Generate (cont)
(10 to -10) dBm
(-10 to > -60) dBm
(-60 to -110) dBm
(10 to -20) dBm
(2 to 26.5) GHz
(2 to 50) GHz
1.1 dB
1.4 dB
2 dB
2.3 dB
HP 83630B
HP 83650B
RF Power – Measure3
0 dBm
(-50 to 0) dBm
(0 to +30) dBm
(-70 to +20) dBm
(-30 to +20) dBm
Displayed Average Noise
Level
(-150 to 0) dBm
50 MHz
9 kHz to 18 GHz
(0.01 to 18) GHz
(0.05 to 50) GHz
3 Hz to 3 GHz
100 kHz to 3 GHz
(> 3 to 6.6) GHz
(> 6.6 to 22) GHz
(> 22 to 26.8) GHz
(> 26.8 to 31.15) GHz
(> 31.15 to 50) GHz
0.4 %
0.092 dB
0.089 dB
0.085 dB
0.15 dB
0.62 dB
0.91 dB
1.7 dB
2.2 dB
2.7 dB
2.2 dB
2.8 dB
HP 432A, 478A-H76,
3458ª
Agilent E4419A &
E9304A-H19
Agilent E4419A &
E4412A
Agilent E4419A &
8487A
50 Ω Terminal
Tuned RF Level – Measure3
(+16 to -10) dBm
(-10 to -20) dBm
(-20 to -30) dBm
(-30 to -40) dBm
(-40 to -50) dBm
(-50 to -60) dBm
(-60 to -70) dBm
(-70 to -80) dBm
(-80 to -90) dBm
(-90 to -100) dBm
100 kHz to 50 GHz
0.026 dB
0.024 dB
0.029 dB
0.04 dB
0.053 dB
0.056 dB
0.063 dB
0.074 dB
0.078 dB
0.096 dB
Agilent N5531S | to 50 GHz |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 15 of 27
Parameter/Range
Frequency CMC2, 8, 10 (±) Comments
Tuned RF Level – Measure3
(cont)
(< -100 to -140) dBm
(< -103 to -133) dBm
(< -100 to -130) dBm
(< -98 to -128) dBm
(< -86 to -116) dBm
(< -87 to -117) dBm
(< -76 to -106) dBm
(< -70 to -100) dBm
(< -58 to -88) dBm
100 kHz to 3.05 GHz
(> 3.05 to 6.6) GHz
(> 6.6 to 13.2) GHz
(> 13.2 to 19.2) GHz
(> 19.2 to 26.5) GHz
(> 26.5 to 31.15) GHz
(> 31.15 to 41) GHz
(> 41 to 45) GHz
(> 45 to 50) GHz
0.096 dB
0.29 dB
0.30 dB
0.12 dB
0.36 dB
0.21 dB
0.15 dB
0.15 dB
0.15 dB
Agilent N5531S
RF Attenuation – Generate
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -121) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -121) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
@ 50 MHz
@ 1.195 GHz
@ 4 GHz
0.0046 dB
0.0049 dB
0.0075 dB
0.0076 dB
0.0094 dB
0.010 dB
0.015 dB
0.018 dB
0.021 dB
0.030 dB
0.037 dB
0.046 dB
0.011 dB
0.013 dB
0.019 dB
0.019 dB
0.024 dB
0.028 dB
0.040 dB
0.050 dB
0.058 dB
0.080 dB
0.10 dB
0.11 dB
0.020 dB
0.025 dB
0.029 dB
0.035 dB
0.042 dB
0.046 dB
0.053 dB
Agilent 8494G &
8496G
Agilent 8494G &
8496G, Agilent
E4448A
Agilent 8494G &
8496G, Agilent
E4448A | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 16 of 27
Parameter/Range
Frequency CMC2, 8, 10 (±) Comments
RF Attenuation – Generate
(cont)
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -121) dB
@ 4 GHz
0.057 dB
0.063 dB
0.070 dB
0.098 dB
0.29 dB
Agilent 8494G &
8496G, Agilent
E4448A
Amplitude Modulation –
Generate
50 Hz to 50 kHz < 95 %
50 Hz to 50 kHz < 99 %
20 Hz to 100 kHz < 95 %
20 Hz to 100 kHz < 99 %
(11 to 13.5) MHz
0.27 % AM
0.33 % AM
0.38 % AM
0.43 % AM
HP 11715A
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 100 kHz
Depth: (5 to 20) %
Depth: (20 to 99) %
Depth: (5 to 20) %
Depth: (20 to 99) %
Depth: (5 to 20) %
Depth: (20 to 99) %
Depth: (5 to 20) %
Depth: (20 to 99) %
(0.1 to 10) MHz
(0.01 to 3) GHz
(3 to 26.5) GHz
(26.5 to 31.15) GHz
(31.15 to 50) GHz
0.87 % of rdg +
0.0005 % AM
2.9 % of rdg +
0.0005 % AM
0.58 % of rdg +
0.0005 % AM
5.2 % of rdg +
0.0005 % AM
1.7 % of rdg +
0.0005 % AM
7.9 % of rdg +
0.0005 % AM
2.3 % of rdg +
0.0005 % AM
30 % of rdg +
0.0005 % AM
6.9 % of rdg +
0.0005 % AM
Agilent N5531S | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 17 of 27
Parameter/Range
Frequency
CMC2, 8, 10 (±)
Comments
Frequency Modulation –
Generate
DC to 100 kHz Rate
DC to 200 kHz Rate
DC to 10 MHz Rate
(11 to 432) MHz
(11 to 432) MHz
(11 to 432) MHz
0.15 % + 0.005 lsd
0.31 % + 0.005 lsd
2.9 % + 0.005 lsd
HP 11715A
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Deviation: 200 Hz to
40 kHz
Rate: 50 Hz to 200 kHz
Deviation: 250 Hz to
400 kHz
(0.25 to 10) MHz
> 0.2 ß
> 1.2 ß
(0.01 to 6.6) GHz
> 0.2 ß
> 0.45 ß
(6.6 to 13.2) GHz
> 0.2 ß
> 8 ß
(13.2 to 31.15) GHz
> 0.2 ß
> 16 ß
(31.15 to 50) GHz
> 0.2 ß
> 32 ß
1.7 % + 0.68 Hz
1.2 % + 0.87 Hz
1.7 % + 2.4 Hz
1.2 % + 27 Hz
2.9 % + 19 Hz
1.2 % + 19 Hz
4.4 % + 27 Hz
1.2 % + 25 Hz
9.8 % + 5.8 Hz
1.2 % + 5.8 Hz
Agilent N5531S
ß is the ratio of
frequency
deviation to
modulation rate
Phase Modulation –
Measure
> 0.7 rad
> 0.3 rad
> 2 rad
> 0.6 rad
> 4 rad
> 1.2 rad
> 4 rad
> 1.3 rad
> 8 rad
> 2.4 rad
100 kHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
(26.5 to 31.5) GHz
(31.5 to 50) GHz
1.2 % + 0.0051 rad
3.5 % + 0.0058 rad
1.2 % + 0.011 rad
3.5 % + 0.01 rad
1.2 % + 0.021 rad
3.5 % + 0.021 rad
1.2 % + 0.0016 rad
3.5 % + 0.000 95 rad
1.2 % + 0.05 rad
3.5 % + 0.0011 rad
Agilent N5531S | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 18 of 27
Parameter/Range
Frequency
CMC2, 8, 10 (±)
Comments
Phase Noise – Measure
(0.25 to 1.6) GHz
(1.2 to 26.5) GHz
1 MHz to 50 GHz
Offsets from CW:
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
Offsets from CW:
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
Offsets from CW:
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
10 MHz
2.6 dB
2.6 dB
2.5 dB
2.4 dB
2.4 dB
2.3 dB
2.8 dB
2.5 dB
2.4 dB
2.4 dB
2.4 dB
2.3 dB
4.4 dB
2.1 dB
1.1 dB
0.91 dB
0.89 dB
0.99 dB
1.4 dB
Agilent E8257D &
N5500A
Agilent E4448A
Phase Noise – Generate3
(0.25 to 40) GHz
Offsets from CW:
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
10 Hz
100 Hz
1 kHz
10 kHz
30 kHz
100 kHz
1 MHz
6 MHz
10 MHz
3.1 dB
3.1 dB
2.7 dB
2.4 dB
2.4 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
2.3 dB
Agilent E8257D
Wenzel 500-13438C | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 19 of 27
Parameter/Range
Frequency
CMC2, 8, 10 (±)
Comments
Audio Distortion –
Measure3
(-80 to 0) dB
(-65 to 0) dB
20 Hz to 20 kHz
(> 20 to 100) kHz
1.3 dB
2.3 dB
HP 8903B
Modulation Distortion –
Measure
(0 to 100) %
100 kHz to 50 GHz
(0.02 to 250) kHz
1.3 dB
Agilent E4448A
Audio Distortion –
Generate
(-80 to 0) dB
(-65 to 0) dB
20 Hz to 20 kHz
(> 20 to 100) kHz
1.3 dB
2.3 dB
HP 8903B
Reflection S11/S22 –
Measure
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
(30 to 300) kHz
> 300 kHz to 1.3 GHz
(> 1.3 to 3.0) GHz
(> 3.0 to 6.0) GHz
45 MHz to 18 GHz
45 MHz to 18 GHz
0.0057 lin
0.0063 lin
0.0086 lin
0.014 lin
(0.012 to + 0.018) lin
(0.83 to + 0.94)°
(0.0064 to + 0.011) lin
(1.1 to + 1.8)°
(0.0051 to + 0.0056) lin
(3.3 to + 180)°
(0.0093 to + 0.015) lin
(0.63 to + 0.72)°
(0.0048 to + 0.0081) lin
(0.77 to + 1.4)°
(0.0035 to + 0.004) lin
(2.3 to + 180)°
HP 8753ES, HP
85029B, HP 85050A-
10
H-P 8510C,
85054A type-N
(sliding load cal)
H-P 8510C,
85050A 7 mm
(sliding load cal) | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 20 of 27
Parameter/Range
Frequency
CMC2, 8, 10 (±)
Comments
Reflection S11/S22 –
Measure
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
(0 to 0.1) lin
(0.1 to 1.0) lin
45 MHz to 26.5 GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
(> 50 to 65) GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
(> 50 to 65) GHz
(0.014 to + 0.023) lin
(1.2 to + 1.2)°
(0.0073 to + 0.012) lin
(1.3 to + 2.1)°
(0.0059 to + 0.0064) lin
(3.3 to + 180)°
0.011 lin
0.011 lin
0.017 lin
0.019 lin
0.023 lin
0.014 lin
0.015 lin
0.024 lin
0.034 lin
0.040 lin
H-P 8510C,
85052B 3.5 mm
(sliding load cal)
Anritsu 37397D,
Anritsu 3654B
Reflection S21/S12 –
Measure
(+10 to 0) dB
(0 to -30) dB
(-30 to -50) dB
(-50 to -60) dB
(+10 to 0) dB
(0 to -30) dB
(-30 to -50) dB
(-50 to -60) dB
(+10 to 0) dB
(0 to -30) dB
(-30 to -50) dB
(-50 to -60) dB
(+10 to 0) dB
(0 to -30) dB
(-30 to -50) dB
(-50 to -60) dB
(0.04 to 2) GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
0.13 dB
0.10 dB
0.15 dB
0.35 dB
0.16 dB
0.13 dB
0.21 dB
0.55 dB
0.23 dB
0.20 dB
0.51 dB
1.3 dB
0.42 dB
0.39 dB
0.77 dB
2 dB
Anritsu 37397D,
Anritsu 3654B | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 21 of 27
Parameter/Range
Frequency
CMC2, 8, 10 (±)
Comments
Reflection S21/S12 –
Measure (cont)
(+10 to 0) dB
(0 to -30) dB
(-30 to -50) dB
(-50 to -60) dB
(> 50 to 65) GHz
0.45 dB
0.48 dB
2.1 dB
5.4 dB
Anritsu 37397D,
Anritsu 3654B
Transmission S12/S21–
Measure
(0 to 0.1) lin
10 dB
0 dB
-10 dB
-20 dB
-30 dB
-40 dB
-50 dB
-60 dB
10 dB
0 dB
-10 dB
(30 to 50) kHz
(> 50 to 300) kHz
(> 0.3 to 1.3) GHz
(> 1.3 to 3.0) GHz
(> 3.0 to 6.0) GHz
45 MHz to 18 GHz
45 MHz to 18 GHz
0.042 lin
0.042 lin
0.042 lin
0.045 lin
0.068 lin
(0.13 to + 0.22) dB
(1.3 to + 4.2)°
(0.051 to + 0.093) dB
(0.21 to + 3.9)°
(0.066 to + 0.093) dB
(0.33 to + 4)°
(0.067 to + 0.094) dB
(0.34 to + 4)°
(0.07 to + 0.097) dB
(0.37 to + 4)°
(0.076 to + 0.12) dB
(0.45 to + 4.2)°
(0.11 to + 0.2) dB
(0.73 to + 4.8)°
(0.24 to + 0.49) dB
(1.7 to + 6.7)°
(0.068 to + 0.22) dB
(1.3 to + 3.8)°
(0.046 to + 0.049) dB
(0.18 to + 3.6)°
(0.05 to + 0.065) dB
(0.3 to + 3.7)°
HP 8753ES, HP
85029B, HP 85050A
HP 8510C,
85054A type-N
(sliding load cal) | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 22 of 27
Parameter/Range
Frequency
CMC2, 8, 10 (±)
Comments
Transmission S12/S21–
Measure (cont)
-20 dB
-30 dB
-40 dB
-50 dB
-60 dB
10 dB
0 dB
-10 dB
-20 dB
-30 dB
-40 dB
-50 dB
-60 dB
(0 to 1) lin
45 MHz to 18 GHz
45 MHz to 26.5 GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
(> 50 to 65) GHz
(0.051 to + 0.067) dB
(0.31 to + 3.7)°
(0.054 to + 0.068) dB
(0.34 to + 3.7)°
(0.063 to + 0.073) dB
(0.43 to + 3.9)°
(0.11 to + 0.15) dB
(0.72 to + 4.5)°
(0.24 to + 0.45) dB
(1.7 to + 6.4)°
(0.13 to + 0.22) dB
(1.3 to + 5.8)°
(0.054 to + 0.11) dB
(0.21 to + 5.7)°
(0.069 to + 0.11) dB
(0.31 to + 5.7)°
(0.07 to + 0.11) dB
(0.34 to + 5.7)°
(0.073 to + 0.13) dB
(0.38 to + 5.9)°
(0.076 to + 0.2) dB
(0.46 to + 6.4)°
(0.11 to + 0.46) dB
(0.75 to + 8.1)°
(0.24 to + 1.4) dB
(1.7 to + 14)°
0.042 lin
0.043 lin
0.046 lin
0.061 lin
0.063 lin
HP 8510C,
85050A 7 mm
(sliding load cal)
HP 8510C,
85052B 3.5 mm
(sliding load cal)
Anritsu 37397D,
Anritsu 3654B | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 23 of 27
V. Mechanical
Parameter/Equipment
Range4
CMC2, 5, 8, 10 (±)
Comments
Mass – Measure
(0.5 to 2) kg
5 kg
58 mg
110 mg
Reference weights &
electronic balance
Scales & Balances3
(1 to 500) mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
30 kg
(0 to 500) lb
6.1 µg + 0.58R
20 µg + 0.58R
20 µg + 0.58R
21 µg + 0.58R
33 µg + 0.58R
50 µg + 0.58R
0.14 mg + 0.58R
0.21 mg + 0.58R
0.38 mg + 0.58R
0.90 mg + 0.58R
1.9 mg + 0.58R
3.7 mg + 0.58R
9.0 mg + 0.58R
19 mg + 0.58R
37 mg + 0.58R
56 mg + 0.58R
0.012 % + 0.58R
Troemner Ultra-
Class weight set
Class F weights
Torque Transducers
(1 to 10) ozf·in
(> 10 to 50) ozf·in
> 50 ozf·in to 8 lbf·in
(> 8 to 100) lbf·in
(10 to 100) lbf·ft
(> 100 to 1000) lbf·ft
0.15 %
0.15 %
0.03 %
0.036 %
0.053 %
0.23 %
Torque wheels &
torque arms with
Ultra Class & Class
F weights
Torque3 – Wrenches &
Drivers
(1 to 10) ozf·in
(> 10 to 50) ozf·in
(1 to 10) lbf·in
(10 to 100) lbf·in
(8 to 100) lbf·ft
(100 to 1000) lbf·ft
1.2 %
0.61 %
0.58 %
0.59 %
0.76 %
0.56 %
AWS ITIO-10
AWS ITIO-50
AWS ITO-10
AWS ITI-100
AKO TSD 2050
torque system
Vacuum – Measure3
(0.01 to 10) Torr
(10 to 1000) Torr
0.087 %
0.089 %
MKS reference
transducers | ||
| 24 | - | OilShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 24 of 27
Parameter/Equipment
Range4
CMC2, 5, 8, 10 (±)
Comments
Pressure Measure &
Measuring Equipment3–
Nitrogen Gas
Oil
(0.01 to 10) Torr
> 10 to 1000 Torr
(1.45 to 60) psig
(> 60 to 300) psig
(1.45 to 200) psig
(> 200 to 1000) psig
(100 to 2000) psig
(> 2000 to 5000) psig
(> 5000 to 10 000) psig
(> 10 000 to 20 000) psig
(> 20 000 to 30 000) psig
0.12 Torr + 0.58R
0.14 Torr + 0.58R
0.011 psi + 0.58R
0.035 psi + 0.58R
0.035 psi + 0.58R
0.12 psi + 0.58R
0.27 psi
0.59 psi
1.2 psi
10 psi
15 psi
Mensor 2101
Additel 780S with
ADT160A AP3000Q,
AP1KQ
Ruska 2450
Air Velocity – Measuring
Equipment
(30 to 250) FPM
(250 to 1500) FPM
(1500 to 9000) FPM
2.4 % + 0.58R
2.4 % + 0.58R
1.3 % + 0.58R
TSI 8390 wind tunnel
Force Gages – Tension &
Compression3
(0 to 1) lbf
(> 1 to 10 lbf)
(> 10 to 100) lbf
(> 100 to 500) lbf
0.0023 lbf + 0.58R
0.0026 lbf + 0.58R
0.054 lbf + 0.58R
0.15 lbf + 0.58R
Weights, weight
hangers
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Temperature – Measure3
(-196 to 0) °C
(> 0 to 420) °C
(> 420 to 660) °C
0.018 °C
0.062 °C
0.087 °C
Fluke probe w/ display | See scope document |
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 25 of 27
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Temperature –
Measuring Equipment3
(-75 to 175) °C
(0 to 100) °C
(-20 to 350) °C
0.068 °C
0.045 °C
0.063 °C
Fluke 1523 with
baths, chambers
, dry
block calibrators
Relative Humidity –
Measure3
(5 to 15) % RH
(> 15 to 35) % RH
(> 35 to 55) % RH
(> 55 to 77) % RH
(> 77 to 95) % RH
0.15 % RH
0.35 % RH
0.5 % RH
0.69 % RH
0.83 % RH
RH Systems 973
Frost & Dew Point –
Measure
(-50 to < 0) °C
(0 to 20) °C
0.16 °C
0.12 °C
RH Systems 973
VII. Time & Frequency
Parameter/Equipment
Range4
CMC2, 5, 10 (±)
Comments
Frequency – Measuring
Equipment3
GPS Reference
10 MHz
1 PPS
0.001 Hz to 10 MHz
(> 0.01 to 12) GHz
(> 12 to 50) GHz
(7 x 10
-12) Hz
(8.3 x 10-12) PPS
(6 x 10-12) Hz + 0.58R
(6.4 x 10-12) Hz + 0.58R
(310 x 10-12) Hz + 0.58R
Fluke 910 GPS
frequency standard
Fluke 910 GPS
standard HP 3325A
& 83650B
Frequency – Measure3
0.001 Hz to 10 MHz
(> 0.01 to 12) GHz
(> 12 to 50) GHz
100 kHz to 50 GHz
(6.8 x 10-12) Hz + 0.58R
(6.4 x 10-12) Hz + 0.58R
(520 x 10-12) Hz + 0.58R
0.12 Hz
Fluke 910 GPS
frequency standard,
Agilent 53132A-
124 & N5531S
Agilent E4448A,
Fluke 910 GPS
frequency standard
Period – Measure
80.6 ps to 4.44 ns
4.44 ns to 5 µs
5 µs to to 10 ms
> 10 ms
3.2 x 10-8 ps
7.9 x 10-11 µs
2.4 x 10-9 µs
3.8 x 10-7 ms
Agilent E4438C,
Fluke 910 GPS,
Agilent 53132A,
Agilent 3325B | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 26 of 27
Parameter/Equipment
Range4
CMC2, 8, 10 (±)
Comments
Timers & Stopwatches3
Totalize – Up to 24 hours
Stopwatch to Stopwatch
(0 to 19.99) s/day
46 ms
510 ms
0.064 s/day
Fluke 910 GPS
standard, HP
53132A & 3325B
Stopwatch
comparison
Timometer
Pulse Characterization
Time Interval, Pulse
Width, Transition
Time & Jitter –
Measure3
Time Interval, Pulse
Width, Transition
Time
DC to 50 GHz
7 ps to 1 ms
1 ns to 100 000 s
9.2 ps + 0.12 %
1.3 ns
HP 54750A &
54752A
HP 53132A, Fluke
910 GPS frequency
standard, HP
81130A
__________________________________________
1 This laboratory offers commercial dimensional testing/calibration, and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Where ranges are not specified, the CMC stated is for the cardinal points only.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
or millimeters. In the statement of CMC, R is the numerical value of the resolution of the device.
6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration. | ||
| 27 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.05) Revised 04/16/2025 Page 27 of 27
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
8 In the statement of CMC, a % is defined as the percentage of reading unless otherwise noted.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 28 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Fluke Calibration, Phoenix - Primary Pressure and FlowPhoenix, AZ · ~595 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Oil
- BHD Test & MeasurementThornton, CO · ~1,347 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Oil
- Process InstrumentsPittsburgh, PA · ~3,440 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Oil
- Micro Quality CalibrationChatsworth, CA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Primary InstrumentsChatsworth, CA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.