Fluke Calibration, Phoenix - Primary Pressure and Flow
4765 East Beautiful Lane, 85044, Phoenix, AZ, United States
- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1599.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1599.01) Revised 03/09/2026 Page 2 of 4
III. Mechanical
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Mass – Measure
Nominal Values
All Values
(2, 3.2, 4.0, 4.5, 5.0, 6.2,
6.4, 10.0, 10.1) kg
(0.8, 1.0, 1.6) kg
(0.1, 0.2, 0.3, 0.4, 0.5) kg
1 mg to 12 kg
0.0001 %
0.000 13 %
0.0002 %
0.0005 % or 0.5 mg,
whichever is greater
True mass
determinations for use
with piston gauges
Pressure – Gas
Effective Area of
Piston – Cylinder
Calibration of
Secondary Standards
& Pressure Devices
(5 to 500) kPa
(500 to 1000) kPa
(1000 to 5000) kPa
(5000 to 11 000) kPa
(11 to 20) MPa
(20 to 50) MPa
(50 to 100) MPa
(0 to 15) kPa
(5 to 500) kPa
(500 to 1000) kPa
(1000 to 5000) kPa
(5000 to 11 000) kPa
(11 to 110) MPa
(-15 to 15) kPa
(-90 to 550) kPa
(-990 to 990) kPa
(-50 to 50) MPa
0.000 56 %
0.000 65 %
0.000 76 %
0.000 77 %
0.0012 %
0.0013 %
0.0015 %
0.0025 % + 8 mPa
0.0009 % + 0.05 Pa
0.0010 %
0.0012 %
0.0014 %
0.0023 %
|0.0025 %| + 5 mPa
|0.001 %| + 0.3 Pa
0.0014 % + (0.1 Pa +
0.000 13 % x LP)
0.0035 % + (0.000 13
% x LP)
From the Fluke
calibration piston-
cylinder pressure
calibration chain
Absolute
Absolute & gauge
Gauge
Differential mode line
pressure from -90 kPa
to 550 kPa
HL differential: LP
(line pressure) range:
(10 to 1000) kPA
Line pressure range:
(1 to 100) MPa | ||
| 3 | - | OilShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1599.01) Revised 03/09/2026 Page 3 of 4
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pressure – Oil
Effective Area of Piston
Cylinder
Calibration of
Secondary Standards &
Pressure Devices
(0.2 to 50) MPa
(50 to 100) MPa
(100 to 200) MPa
(200 to 500) MPa
(0.1 to 20) MPa
(20 to 100) MPa
(100 to 200) MPa
(200 to 500) MPa
(500 to 700) MPa
0.0013 %
0.0015 %
0.0022 %
0.003 %
0.0017 % + 14 Pa
0.002 %
0.003 %
0.0047 %
0.03 %
From the Fluke
calibration piston-
cylinder pressure
calibration chain
Gauge & absolute
Pressure – Oil
Calibration of
Secondary Standards &
Pressure Devices
3
(0.1 to 20) MPa
(20 to 50) MPa
(50 to 70) MPa
(70 to 140) MPa
(140 to 200) MPa
(200 to 350) MPa
(350 to 500) MPa
0.0018 % + 14 Pa
0.0023 %
0.0025 %
0.0033 %
0.0038 %
0.0055 %
0.0075 %
Gauge & absolute
Calibration of Pressure
Devices
3 –
Gas
(0 to 133) Pa
(1.4 to 5) kPa
(5 to 550) kPa
(5 to 550) kPa
(550 to 2750) kPa
(550 to 2750) kPa
(2750 to 11 000) kPa
(11 to 20) MPa
(20 to 50) MPa
(50 to 103) MPa
(-7.5 to 7.5) kPa
(-1.4 to -100) kPa
0.5 % + 0.15 Pa
0.0015 % + 1 Pa
0.0015 % + 0.01 Pa
0.0015 % + 0.2 Pa
0.0017 %
0.0017 % + 0.2 Pa
0.0017 %
0.0019 %
0.0027 %
0.0038 %
|0.006 %| + 0.07 Pa
|0.0015 %| + 0.05 Pa
Gauge & absolute
(except where noted)
Absolute; using
capacitance diaphragm
pressure transducer
Absolute
Gauge
Absolute
Gauge
Absolute
Differential; using
quartz bourdon tube
pressure transducer
Negative gauge | See scope document |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1599.01) Revised 03/09/2026 Page 4 of 4
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature – Measure &
Measuring Equipment
(15 to 30) °C
0.03 °C
Fluke thermistor
Relative Humidity –
Measure & Measuring
Equipment
(5 to 95) % RH
3 % RH
Vaisala humidity probe
V. Time & Frequency
Parameter/Equipment
Frequency
CMC
2, 4, 6 (±)
Comments
Frequency – Measure
1000 Hz
0.0008 %
HP 53131A
__________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are to be read as percent of reading, unless indicated otherwise.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | 15 to 30 °C |
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - Los AngelesPanorama City, CA · ~595 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Oil
- BHD Test & MeasurementThornton, CO · ~953 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Oil
- Process InstrumentsPittsburgh, PA · ~2,936 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Oil
- Marvel Aero International, Inc., DBA Christie Distribution & Service CenterPhoenix, AZ · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ALS OIL & LUBRICANTS (TRIBOLOGY)Phoenix, AZ · ~6 kmA2LAShares 1 accredited materialOil
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.