Registers refreshed 2026-11-20.See refresh dates
Canada

Matrox Conformity Group

Dorval, Canada

Visit website
A2LA 993.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
15
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 15 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series10
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

KS C 9610-3-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

KS C 9610-3-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national

National versions in the same scope

KS C 9610-4-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national

National versions in the same scope

KS C 9610-4-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national

National versions in the same scope

KS C 9610-4-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national

National versions in the same scope

KS C 9610-4-5national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national

National versions in the same scope

KS C 9610-4-6national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national

National versions in the same scope

KS C 9610-4-11probably the same standard; matched by number only

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS CISPR 11national version with changes

KS C 9811national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national

National versions in the same scope

AS/NZS CISPR 32identical to it

CNS 15936identical to it

KS C 9832national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national

National versions in the same scope

KS C 9835national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Other standards2
FCC PART 15Radio Frequency Devices
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

993.01

The scope document we hold says it is valid until 2027-11-30.

View scope

Accredited scope, certificate 993.01

LineMethodMatrixRange
1CFR 47, FCC Part 15 B (using ANSI C63.4:2014); CISPR 32 (except CISPR 13); EN 55032; KS C 9832; AS/NZS CISPR 32; AS CISPR 11; CISPR 11; EN 55011; CNS 13803:2018; CNS 13438:2006; CNS 15936:2016; KS C 9811; KS C 9610-6-4; ICES-003; ICES-001; IEC/EN 61000-6-4; IEC/EN 61000-3-2; KS C 9610-3-2; IEC/EN 61000-3-3; KS C 9610-3-3; IEC/EN 61000-4-3; KS C 9610-4-3; IEC/EN 61000-4-6; KS C 9610-4-6; IEC/EN 61000-4-2; KS C 9610-4-2; IEC/EN 61000-4-4; KS C 9610-4-4; IEC/EN 61000-4-5; KS C 9610-4-5; IEC/EN 61000-4-11; KS C 9610-4-11; ISO/IEC 17025:2017electrical and electronic equipment80 to 5 MHz to GHz
2CISPR 35; EN55035; KS C 9835; IEC/EN 61326-1; KC S IEC 61326-1; IEC/EN 61000-6-2; KS C 9610-6-2; KS C 9610-4-8; IEC/EN 61000-4-3; KS C 9610-4-3; ANSI C63.4:2014materials and products related to Multimedia Equipment (MME); IT Equipment, Audio Equipment, and Video EquipmentSee scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited MATROX CONFORMITY GROUP Dorval, Quebec, Canada for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 13th day of November 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0993.01 Valid to November 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .