Trescal, Inc. - Philadelphia, PA

1565 Bustard Road, 19446, Lansdale, PA, United States

Visit website
A2LA 2551.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 2551.01 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 2 of 16 Parameter/Equipment Range CMC2 (±) Comments Calipers3 – Outside Depth & Step Inside Up to 24 in Up to 24 in 1 in 10 µin + 8 µin/in 15 µin + 7 µin/in 44 µin Gage blocks Gage blocks, surface plate Gage blocks, accessories Rulers Up to 12 in 35 µin + 10 µin/in Glass scale Dial Indicators3 Up to 1 in 14 µin + 32 µin/in Gage blocks III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage – Generate (0 to 330) mV (0 to 3.3) V (0 to 33) V (0 to 330) V (100 to 1000) V 18 µV/V + 1 µV 14 µV/V + 2.0 µV 15 µV/V + 20 µV 21 µV/V + 150 µV 15 µV/V + 1.5 mV Fluke 5520A DC Voltage – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 4.4 µV/V + 0.24 µV 4.1 µV/V + 0.4 µV 5.0 µV/V + 4 µV 6.4 µV/V + 40 µV 4.6 µV/V + 500 µV Fluke 8508A DC High Voltage – Measure (1 to 20) kV (20 to 25) kV 2.3 % 1.2 % Fluke 80K-40 with Fluke 8508A DC Clamp-On – Generate (20 to 150) A (150 to 1000) A 0.66 % + 0.14 A 0.43 % + 0.5 A Fluke 5520A/Fluke 50 turn coil
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 3 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Generate (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A 16 nA + 0.12 nA/µA 42 nA + 77 nA/mA 0.23 µA + 77 nA/mA 2 µA + 79 nA/mA 32 µA + 0.16 mA/A 0.36 mA + 0.3 mA/A 0.5 mA + 0.38 mA/A 9.2 mA + 0.79 mA/A Fluke 5520A DC Current – Measure (0 to 200) µA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 570 pA + 20 pA/µA 5 nA + 17 nA/mA 71 nA + 20 nA/mA 2.1 µA + 69 nA/mA 37 µA + 230 µA/A 820 µA + 500 µA/A Fluke 8508A Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 34 µΩ/Ω + 0.01 Ω 24 µΩ/Ω + 0.015 Ω 23 µΩ/Ω + 0.015 Ω 23 µΩ/Ω + 0.02 Ω 21 µΩ/Ω + 0.02 Ω 22 µΩ/Ω + 0.2 Ω 23 µΩ/Ω + 0.1 Ω 24 µΩ/Ω + 1 Ω 24 µΩ/Ω + 1 Ω 46 µΩ/Ω + 10 Ω 24 µΩ/Ω + 10 Ω 44 µΩ/Ω + 150 Ω 0.011 % + 250 Ω 0.021 % + 2.5 kΩ 0.048 % + 3 kΩ 0.24 % + 100 kΩ 1.2 % + 500 kΩ Fluke 5520A Resistance – Generate, Fixed Points 25 Ω 75 Ω 100 Ω 200 Ω 400 Ω 0.000 18 Ω 0.0014 Ω 0.000 71 Ω 0.0014 Ω 0.0028 Ω M.I. 5420-25 IET SRX-75 M.I. 5420-100 M.I. 5420-200 M.I. 5420-400 Resistance – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ 8 µΩ + 17 µΩ/Ω 58 µΩ + 8 µΩ/Ω 190 µΩ + 8 µΩ/Ω 1.4 mΩ + 8 µΩ/Ω 14 mΩ + 8 µΩ/Ω 0.13 Ω + 8 µΩ/Ω 1.9 Ω + 10 µΩ/Ω 130 Ω + 21 µΩ/Ω 12 kΩ + 120 µΩ/Ω 1.2 MΩ + 1.4 mΩ/Ω Fluke 8508A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 4 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators & Indicating Systems 3 – Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.40 °C 0.19 °C 0.17 °C 0.20 °C 0.54 °C 0.24 °C 0.18 °C 0.17 °C 0.18 °C 0.58 °C 0.28 °C 0.21 °C 0.18 °C 0.23 °C 0.57 °C 0.51 °C 0.23 °C 0.19 °C 0.18 °C Fluke 5520A Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (1 to 33) mV (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.063 % + 6 µV 0.016 % + 6 µV 0.019 % + 6 µV 0.08 % + 6 µV 0.28 % + 12 µV 0.63 % + 50 µV 0.037 % + 8 µV 0.012 % + 8 µV 0.013 % + 8 µV 0.028 % + 8 µV 0.063 % + 32 µV 0.16 % + 70 µV Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 5 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (cont) 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz 0.024 % + 50 µV 0.012 % + 60 µV 0.015 % + 60 µV 0.024 % + 50 µV 0.055 % + 130 µV 0.19 % + 600 µV 0.024 % + 650 µV 0.012 % + 600 µV 0.019 % + 600 µV 0.028 % + 600 µV 0.07 % + 1.6 mV 0.016 % + 2 mV 0.016 % + 6 mV 0.02 % + 6 mV 0.025 % + 6 mV 0.16 % + 50 mV 0.024 % + 0.13 mV 0.02 % + 10 mV Fluke 5520A AC Voltage – Measure (0 to 200) mV (0.2 to 2) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 160 nV/mV + 14 µV 0.014 % + 4 µV 93 µV/V + 4 µV 0.011 % + 2 µV 0.012 % + 4 µV 0.028 % + 8 µV 150 µV/V + 150 µV 0.01 % + 20 µV 83 µV/V + 20 µV 63 µV/V + 20 µV 90 µV/V + 20 µV 0.019 % + 40 µV 0.047 % + 200 µV Fluke 8508A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 6 of 16 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Voltage – Measure (cont) (2 to 20) V (20 to 200) V (200 to 1000) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (10 to 40) Hz 40 Hz to 10 kHz 160 µV/V + 290 µV 95 µV/V + 200 µV 74 µV/V + 200 µV 64 µV/V + 200 µV 89 µV/V + 200 µV 0.018 % + 400 µV 0.045 % + 2 mV 0.24 % + 20 mV 160 µV/V + 12 mV 95 µV/V + 2 mV 73 µV/V + 2 mV 62 µV/V + 2 mV 88 µV/V + 2 mV 0.018 % + 4 mV 0.046 % + 20 mV 0.01 % + 20 mV 93 µV/V + 20 mV Fluke 8508A AC High Voltage – Measure (1 to 5) kV 60 Hz 5.8 % Fluke 80K-40 with Fluke 8508A AC Current – Generate (30 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.12 % + 0.1 µA 0.10 % + 0.1 µA 0.23 % + 0.15 µA 0.62 % + 0.2 µA 1.3 % + 0.4 µA 0.12 % + 0.4 µA 0.08 % + 0.15 µA 0.16 % + 0.2 µA 0.39 % + 0.3 µA 0.78 % + 0.6 µA 0.07 % + 2 µA 0.03 % + 2 µA 0.06 % + 2 µA 0.16 % + 3 µA 0.32 % + 4 µA Fluke 5520A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 7 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate (cont) (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz 0.07 % + 20 µA 0.03 % + 20 µA 0.08 % + 50 µA 0.2 % + 100 µA 0.13 % + 100 µA 0.04 % + 100 µA 0.42 % + 1 mA 1.8 % + 5 mA 0.14 % + 10 mA 0.05 % + 10 mA 0.47 % + 1 mA 2 % + 5 mA 0.05 % + 2 mA 0.08 % + 2 mA 2.4 % + 2 mA 0.1 % + 5 mA 0.12 % + 5 mA 2.4 % + 5 mA Fluke 5520A Clamp-On Meters – Generate Toroidal: (20 to 150) A (150 to 1000) A Non-Toroidal: (20 to 150) A (150 to 1000) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.48 % + 0.025 A 0.76 % + 0.027 A 0.24 % + 0.09 A 0.98 % + 0.1 A 0.61 % + 0.25 A 0.89 % + 0.25 A 0.45 % + 0.9 A 1.1 % + 0.9 A Fluke 5520A & Fluke 50 turn coil
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 8 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure (0 to 200) µA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A (1 to 10) Hz (0.010 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.010 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.010 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.010 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.02 % + 0.02 µA 0.03 % + 0.02 µA 0.06 % + 0.02 µA 0.31 % + 0.02 µA 0.02 % + 0.2 µA 0.02 % + 0.2 µA 0.06 % + 0.2 µA 0.31 % + 0.2 µA 0.03 % + 2 µA 0.03 % + 2 µA 0.06 % + 2 µA 0.31 % + 2 µA 0.02 % + 20 µA 0.02 % + 20 µA 0.05 % + 20 µA 0.05 % + 200 µA 0.06 % + 200 µA 0.23 % + 200 µA 0.06 % + 2 mA 0.19 % + 2 mA Fluke 8508A Parameter/Equipment Range CMC2, 5 (±) Comments Oscilloscope – Amplitude – DC Signal: 50 Ω Load 1 MΩ Load Amplitude – Square Wave: 50 Ω Load 1 MΩ Load (0 to 6.6) V (0 to 130) V 1 mV to 6.6 Vp-p 10 Hz to 10 kHz 1 mV to 130 Vp-p 10 Hz to 1 kHz 1 mV to 130 Vp-p (1 to 10) kHz 33 µV + 2 mV/V 33 µV + 390 µV/V 40 µV + 2 mV/V 190 µV + 780 µV/V 230 µV + 1.9 mV/V Fluke 5522A/ SC1100
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 9 of 16 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Oscilloscope – (cont) Edge Into 50 Ω Bandwidth Into 50 Ω: 5 mV to 5.5 V 4 mV to 3.5 V Time Marker Into 50 Ω (200 to 300) ps 1 kHz to 2 MHz (200 to 350) ps (2 to 10) MHz 50 kHz (Reference) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 2 ns to 20 ms 50 ms to 5 s 82 ps 82 ps 330 µV + 17 mV/V 400 µV + 31 mV/V 420 µV + 36 mV/V 520 µV + 57 mV/V 580 µV + 67 mV/V 0.000 52 % 0.000 63 % x T x 0.1 % Fluke 5522A/ SC1100 T = time in seconds IV. Fluid Quantities Parameter/Equipment Range CMC2, 4, 6 (±) Comments Gas Flow – Measuring Equipment3 10 sccm to 5 SLPM (5 to 30) SLPM (30 to 100) SLPM (100 to 2000) SLPM 0.31 % 0.41 % 0.68 % 0.38 % Molbox™1 + /Molbloc™-L Molbox ™1 + /Molbloc™-S Volume – Calibration of Pipettes, Fixed Points3 0.1 µL 0.5 µL 1 µL 2 µL 5 µL 10 µL 20 µL 50 µL 100 µL 200 µL 500 µL 1000 µL 2000 µL 5000 µL 10 000 µL 0.01 µL 0.021 µL 0.029 µL 0.027 µL 0.048 µL 0.048 µL 0.062 µL 0.12 µL 0.21 µL 0.31 µL 1.4 µL 1.5 µL 1.5 µL 3.9 µL 7 µL Gravimetric method
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 10 of 16 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Gas Concentration3 – Measure O2 CO2 (0 to 5) Mole % O 2 (5 to 20) Mole % O2 (0 to 5) Mole % CO 2 (5 to 20) Mole % CO2 0.83 Mole % 0.83 Mole % + 0.55 % of rdg 0.48 Mole % 0.48 Mole % + 1.5 % of rdg Extech SDL 150 oxygen meter Vaisala MI70 w/GMP70 Gas Detection Equipment – O2 CO2 5 Mole % O 2 10 Mole % O2 20 Mole % O2 5 Mole % CO2 10 Mole % CO2 20 Mole % CO2 0.12 Mole % 0.23 Mole % 0.46 Mole % 0.12 Mole % 0.23 Mole % 0.46 Mole % Certified gas V. Mechanical Parameter/Equipment Range CMC2 (±) Comments Calibration of Mass Standards – Fixed Points 0.001 g 0.002 g 0.003 g 0.005 g 0.010 g 0.020 g 0.030 g 0.050 g 0.10 g 0.20 g 0.30 g 0.50 g 1.0 g 2.0 g 5.0 g 10 g 20 g 30 g 1.4 µg 1.2 µg 1.2 µg 1.4 µg 1.4 µg 1.5 µg 1.5 µg 1.7 µg 0.9 µg 0.8 µg 1.4 µg 1.4 µg 2.6 µg 2.7 µg 5.3 µg 8 µg 8 µg 11 µg Mass measurement by appropriate mass comparator method (ABBA, ABA, modified ABA, etc.) Troemner Ultra Class & ASTM Class 1 mass pieces
11ASTM Class 1; ASTM Class 3-See scope document
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 12 of 16 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Pneumatic Pressure – Measuring Equipment3 Hydraulic Gage Pressure – Measuring Equipment Pressure – Measuring Equipment 3 Vacuum – Measuring Equipment 3 (0 to 30) inH2O (-14 to 0) psig (0 to 145) psig (-14 to 0) psig (0 to 500) psig (0.015 to 17.5) psia (17.5 to 35) psia (8.75 to 17.5) psia (50 to 10 000) psig (0 to 1) inH 2O (0 to 10) inH2O (0 to 15) psi (-14 to 200) psi (50 to 10 000) psi Up to 1000 mTorr (1 to 1000) Torr 0.000 17 inH2O + 0.0001 inH2O/inH2O 0.0084 psi 0.0084 psi + 0.000 058 psi/psi 0.029 psi 0.029 psi + 0.000 059 psi/psi 0.0006 psia 0.002 psia + 0.000 056 psia/psia 0.001 psia 0.03 % 0.0036 psi 0.031 psi 0.0081 psi + 0.0001 psi/psi 0.16 psi 8.1 psi + 0.000 029 psi/psi 2.5 % 2.5 % Fluke 7250LP Mensor CPC6000 580DX dead weight tester Fluke 700P00 Fluke 700P01 Fluke 700P04 Fluke 700PD7 Fluke 700P31 MKS PVS6 Torque Wrenches (5 to 50) ozf·in (15 to 200) ozf·in (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft (4.4 to 44) lbf·in (44 to 440) lbf·in (36 to 362) lbf·ft (60 to 600) lbf·ft 0.63 % 0.53 % 0.3 % 0.3 % 0.33 % 0.3 % 0.33 lbf·in 2.9 lbf·in 2.4 lbf·ft 0.31 % CDI torque calibration system Torque Transducers 5 ozf in to 2000 lbf·ft 0.036 % Torque arms, wheels, & standard weights
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 13 of 16 VI. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Infrared Temperature – Measuring Equipment (-15 to -12) °C (-12 to -8) °C (-8 to -4) °C (-4 to 0) °C (0 to 120) °C (35 to 500) °C 0.51 °C 0.5 °C 0.49 °C 0.48 °C 0.6 °C + 0.0017 °C/°C 0.54 °C + ΔTChange from 35 °C x 0.0042 °C Fluke 4180 Ɛ = (0.9 to 1.0) λ = (8 to 14) µm Fluke 4181 Ɛ = (0.9 to 1.0) λ = (8 to 14) µm Relative Humidity – Measuring Equipment (0 to 70) °C (10 to 95) % RH 0.63 % RH Thunder Scientific 2500ST- LT Relative Humidity – Measure3 (10 to 90) % RH 1.6 % RH Vaisala MI70 & HMP77 Temperature – Measure3 (-196 to 660) °C (-196 to 660) °C (-196 to 660) °C (-196 to 660) °C (660 to 1200) °C 0.0025 °C + 0.000 021 °C/ °C 0.0058 °C + 0.000 016 °C/ °C 0.0029 °C + 0.000 002 °C/ °C 0.13 °C 1.1 °C + 0.004 °C/°C Fluke 1595A thermometer, Fluke 5699 SPRT Additel 286 thermometer, Fluke 5699 SPRT Additel 286 thermometer, standard resistor, Fluke 5699 SPRT Additel 286 Thermometer w/286-TS temperature scanner, Fluke 5699 SPRT Thermocouple scanner w/Type S thermocouple probe
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 14 of 16 Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measuring Equipment Fixed Point: * Liquid Nitrogen Mercury Triple Point Water Indium Tin Zinc Aluminum Comparison** Comparison*** Thermocouple / RTD -195.8 °C -38.8344 °C 0.010 °C 156.5985 °C 231.928 °C 419.527 °C 660.323 °C (-90 to 0) °C (0 to 200) °C (200 to 300) °C (300 to 400) °C (400 to 660) °C (-90 to -80) °C (-80 to -5) °C (-5 to 110) °C (110 to 180) °C (180 to 550) °C (550 to 660) °C (660 to 1200) °C 3.4 mK 2.6 mK 0.25 mK 3 mK 3.2 mK 3.5 mK 5.3 mK 0.0083 °C 0.004 °C 0.0043 °C 0.0065 °C + 0.000 078 x Tchange from 300 °C 0.014 °C + 0.000 061 x T change from 400 °C 0.017 °C 0.013 °C 0.011 °C 0.016 °C + 0.000 056 x T change from 110 °C 0.016 °C + 0.000 052 x Tchange from 180 °C 0.028 °C 1.2 °C + 0.0039 x Tchange from 660 °C Fluke miniature fixed reference point cells, SPRT * PRT/SPRT with accuracy down to 0.02 °C (20 mK) Fluke 1595A, Fluke 5699 PRT, calibration baths & reference point cells ** Equipment with accuracy down to 0.15 °C Fluke 5628 PRT, calibration baths & furnaces ***Equipment with accuracy down to 0.2 °C Type “S” thermocouple, calibration furnace Temperature – Measuring Equipment, Thermistors (0 to 100) °C 3.7 mK Fluke 1595A, Fluke 5681 PRT, calibration bath
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 15 of 16 Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measuring Equipment3 (0 to 150) °C (150 to 1000) °C (-195 to 500) °C (20 to 60) °C 0.71 °C + 0.0007 °C/°C 1.4 °C + 0.0041 x Tchange from 150 °C 0.12 °C 0.27 °C + 0.0026 °C/°C Fluke 741, Type T thermocouple Fluke 741, Type K thermocouple Fluke 1524, Burns 200G RTD Vaisala MI70 w/HMP77B Dew Point – Measuring Equipment (-95 to -90) °C (-90 to -80) °C (-80 to -70) °C (-70 to 10) °C (10 to 60) °C 0.93 °C 0.56 °C 0.54 °C 0.38 °C 0.44 °C Thunder Scientific 3900 humidity generator Thunder Scientific 2500ST-LT VII. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measure 0.1 Hz to 225 MHz 5.8 µHz + 5.8 µHz/Hz Keysight 53131A Frequency – Measuring Equipment (0.01 to 15) MHz 5.8 µHz + 26 µHz/Hz Keysight 33120A function generator Rotational Speed – Optical3 – Measuring Equipment (2.5 to 100 000) RPM 0.000 031 RPM + 0.000 039 RPM/RPM Fluke 5522A RPM – Measure3 (2.5 to 100 000) RPM 1.1 RPM + 0.0058 RPM/RPM Tachometer Time – Measure3 Up to 36 000 sec 0.001 % of time + 37 ms Stopwatch Stopwatches & Timers3 (0 to 19.99) s/day 0.037 s/day Timometer ___________________________________________ 1 This laboratory offers commercial calibration service.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2551.01) 2/12/2025 Page 16 of 16 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the measured displacement in inches; a percent refers to percent of reading unless otherwise noted. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
17ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.