Trescal, Inc. - Philadelphia, PA
1565 Bustard Road, 19446, Lansdale, PA, United States
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 2551.01 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 2 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Calipers3 –
Outside
Depth & Step
Inside
Up to 24 in
Up to 24 in
1 in
10 µin + 8 µin/in
15 µin + 7 µin/in
44 µin
Gage blocks
Gage blocks, surface
plate
Gage blocks,
accessories
Rulers
Up to 12 in
35 µin + 10 µin/in
Glass scale
Dial Indicators3
Up to 1 in
14 µin + 32 µin/in
Gage blocks
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage – Generate
(0 to 330) mV
(0 to 3.3) V
(0 to 33) V
(0 to 330) V
(100 to 1000) V
18 µV/V + 1 µV
14 µV/V + 2.0 µV
15 µV/V + 20 µV
21 µV/V + 150 µV
15 µV/V + 1.5 mV
Fluke 5520A
DC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
4.4 µV/V + 0.24 µV
4.1 µV/V + 0.4 µV
5.0 µV/V + 4 µV
6.4 µV/V + 40 µV
4.6 µV/V + 500 µV
Fluke 8508A
DC High Voltage –
Measure
(1 to 20) kV
(20 to 25) kV
2.3 %
1.2 %
Fluke 80K-40 with
Fluke 8508A
DC Clamp-On –
Generate
(20 to 150) A
(150 to 1000) A
0.66 % + 0.14 A
0.43 % + 0.5 A
Fluke 5520A/Fluke 50
turn coil | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 3 of 16
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current –
Generate
(0 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
16 nA + 0.12 nA/µA
42 nA + 77 nA/mA
0.23 µA + 77 nA/mA
2 µA + 79 nA/mA
32 µA + 0.16 mA/A
0.36 mA + 0.3 mA/A
0.5 mA + 0.38 mA/A
9.2 mA + 0.79 mA/A
Fluke 5520A
DC Current –
Measure
(0 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
570 pA + 20 pA/µA
5 nA + 17 nA/mA
71 nA + 20 nA/mA
2.1 µA + 69 nA/mA
37 µA + 230 µA/A
820 µA + 500 µA/A
Fluke 8508A
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
34 µΩ/Ω + 0.01 Ω
24 µΩ/Ω + 0.015 Ω
23 µΩ/Ω + 0.015 Ω
23 µΩ/Ω + 0.02 Ω
21 µΩ/Ω + 0.02 Ω
22 µΩ/Ω + 0.2 Ω
23 µΩ/Ω + 0.1 Ω
24 µΩ/Ω + 1 Ω
24 µΩ/Ω + 1 Ω
46 µΩ/Ω + 10 Ω
24 µΩ/Ω + 10 Ω
44 µΩ/Ω + 150 Ω
0.011 % + 250 Ω
0.021 % + 2.5 kΩ
0.048 % + 3 kΩ
0.24 % + 100 kΩ
1.2 % + 500 kΩ
Fluke 5520A
Resistance –
Generate, Fixed
Points
25 Ω
75 Ω
100 Ω
200 Ω
400 Ω
0.000 18 Ω
0.0014 Ω
0.000 71 Ω
0.0014 Ω
0.0028 Ω
M.I. 5420-25
IET SRX-75
M.I. 5420-100
M.I. 5420-200
M.I. 5420-400
Resistance – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2) kΩ
(2 to 20) kΩ
(20 to 200) kΩ
(0.2 to 2) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
8 µΩ + 17 µΩ/Ω
58 µΩ + 8 µΩ/Ω
190 µΩ + 8 µΩ/Ω
1.4 mΩ + 8 µΩ/Ω
14 mΩ + 8 µΩ/Ω
0.13 Ω + 8 µΩ/Ω
1.9 Ω + 10 µΩ/Ω
130 Ω + 21 µΩ/Ω
12 kΩ + 120 µΩ/Ω
1.2 MΩ + 1.4 mΩ/Ω
Fluke 8508A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 4 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicators
& Indicating Systems
3 –
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.40 °C
0.19 °C
0.17 °C
0.20 °C
0.54 °C
0.24 °C
0.18 °C
0.17 °C
0.18 °C
0.58 °C
0.28 °C
0.21 °C
0.18 °C
0.23 °C
0.57 °C
0.51 °C
0.23 °C
0.19 °C
0.18 °C
Fluke 5520A
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.063 % + 6 µV
0.016 % + 6 µV
0.019 % + 6 µV
0.08 % + 6 µV
0.28 % + 12 µV
0.63 % + 50 µV
0.037 % + 8 µV
0.012 % + 8 µV
0.013 % + 8 µV
0.028 % + 8 µV
0.063 % + 32 µV
0.16 % + 70 µV
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 5 of 16
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(cont)
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
0.024 % + 50 µV
0.012 % + 60 µV
0.015 % + 60 µV
0.024 % + 50 µV
0.055 % + 130 µV
0.19 % + 600 µV
0.024 % + 650 µV
0.012 % + 600 µV
0.019 % + 600 µV
0.028 % + 600 µV
0.07 % + 1.6 mV
0.016 % + 2 mV
0.016 % + 6 mV
0.02 % + 6 mV
0.025 % + 6 mV
0.16 % + 50 mV
0.024 % + 0.13 mV
0.02 % + 10 mV
Fluke 5520A
AC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
160 nV/mV + 14 µV
0.014 % + 4 µV
93 µV/V + 4 µV
0.011 % + 2 µV
0.012 % + 4 µV
0.028 % + 8 µV
150 µV/V + 150 µV
0.01 % + 20 µV
83 µV/V + 20 µV
63 µV/V + 20 µV
90 µV/V + 20 µV
0.019 % + 40 µV
0.047 % + 200 µV
Fluke 8508A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 6 of 16
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage –
Measure (cont)
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
40 Hz to 10 kHz
160 µV/V + 290 µV
95 µV/V + 200 µV
74 µV/V + 200 µV
64 µV/V + 200 µV
89 µV/V + 200 µV
0.018 % + 400 µV
0.045 % + 2 mV
0.24 % + 20 mV
160 µV/V + 12 mV
95 µV/V + 2 mV
73 µV/V + 2 mV
62 µV/V + 2 mV
88 µV/V + 2 mV
0.018 % + 4 mV
0.046 % + 20 mV
0.01 % + 20 mV
93 µV/V + 20 mV
Fluke 8508A
AC High Voltage –
Measure
(1 to 5) kV
60 Hz
5.8 %
Fluke 80K-40 with
Fluke 8508A
AC Current –
Generate
(30 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.12 % + 0.1 µA
0.10 % + 0.1 µA
0.23 % + 0.15 µA
0.62 % + 0.2 µA
1.3 % + 0.4 µA
0.12 % + 0.4 µA
0.08 % + 0.15 µA
0.16 % + 0.2 µA
0.39 % + 0.3 µA
0.78 % + 0.6 µA
0.07 % + 2 µA
0.03 % + 2 µA
0.06 % + 2 µA
0.16 % + 3 µA
0.32 % + 4 µA
Fluke 5520A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 7 of 16
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate
(cont)
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
0.07 % + 20 µA
0.03 % + 20 µA
0.08 % + 50 µA
0.2 % + 100 µA
0.13 % + 100 µA
0.04 % + 100 µA
0.42 % + 1 mA
1.8 % + 5 mA
0.14 % + 10 mA
0.05 % + 10 mA
0.47 % + 1 mA
2 % + 5 mA
0.05 % + 2 mA
0.08 % + 2 mA
2.4 % + 2 mA
0.1 % + 5 mA
0.12 % + 5 mA
2.4 % + 5 mA
Fluke 5520A
Clamp-On Meters –
Generate
Toroidal:
(20 to 150) A
(150 to 1000) A
Non-Toroidal:
(20 to 150) A
(150 to 1000) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.48 % + 0.025 A
0.76 % + 0.027 A
0.24 % + 0.09 A
0.98 % + 0.1 A
0.61 % + 0.25 A
0.89 % + 0.25 A
0.45 % + 0.9 A
1.1 % + 0.9 A
Fluke 5520A & Fluke
50 turn coil | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 8 of 16
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Measure
(0 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(1 to 10) Hz
(0.010 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(0.010 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(0.010 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(0.010 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.02 % + 0.02 µA
0.03 % + 0.02 µA
0.06 % + 0.02 µA
0.31 % + 0.02 µA
0.02 % + 0.2 µA
0.02 % + 0.2 µA
0.06 % + 0.2 µA
0.31 % + 0.2 µA
0.03 % + 2 µA
0.03 % + 2 µA
0.06 % + 2 µA
0.31 % + 2 µA
0.02 % + 20 µA
0.02 % + 20 µA
0.05 % + 20 µA
0.05 % + 200 µA
0.06 % + 200 µA
0.23 % + 200 µA
0.06 % + 2 mA
0.19 % + 2 mA
Fluke 8508A
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Oscilloscope –
Amplitude – DC Signal:
50 Ω Load
1 MΩ Load
Amplitude – Square Wave:
50 Ω Load
1 MΩ Load
(0 to 6.6) V
(0 to 130) V
1 mV to 6.6 Vp-p
10 Hz to 10 kHz
1 mV to 130 Vp-p
10 Hz to 1 kHz
1 mV to 130 Vp-p
(1 to 10) kHz
33 µV + 2 mV/V
33 µV + 390 µV/V
40 µV + 2 mV/V
190 µV + 780 µV/V
230 µV + 1.9 mV/V
Fluke 5522A/
SC1100 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 9 of 16
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Oscilloscope –
(cont)
Edge Into 50 Ω
Bandwidth Into 50 Ω:
5 mV to 5.5 V
4 mV to 3.5 V
Time Marker Into 50 Ω
(200 to 300) ps
1 kHz to 2 MHz
(200 to 350) ps
(2 to 10) MHz
50 kHz (Reference)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
2 ns to 20 ms
50 ms to 5 s
82 ps
82 ps
330 µV + 17 mV/V
400 µV + 31 mV/V
420 µV + 36 mV/V
520 µV + 57 mV/V
580 µV + 67 mV/V
0.000 52 %
0.000 63 % x T x 0.1 %
Fluke 5522A/
SC1100
T = time in seconds
IV. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Gas Flow – Measuring
Equipment3
10 sccm to 5 SLPM
(5 to 30) SLPM
(30 to 100) SLPM
(100 to 2000) SLPM
0.31 %
0.41 %
0.68 %
0.38 %
Molbox™1 +
/Molbloc™-L
Molbox
™1 +
/Molbloc™-S
Volume – Calibration of
Pipettes, Fixed Points3
0.1 µL
0.5 µL
1 µL
2 µL
5 µL
10 µL
20 µL
50 µL
100 µL
200 µL
500 µL
1000 µL
2000 µL
5000 µL
10 000 µL
0.01 µL
0.021 µL
0.029 µL
0.027 µL
0.048 µL
0.048 µL
0.062 µL
0.12 µL
0.21 µL
0.31 µL
1.4 µL
1.5 µL
1.5 µL
3.9 µL
7 µL
Gravimetric method | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 10 of 16
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Gas Concentration3 –
Measure
O2
CO2
(0 to 5) Mole % O
2
(5 to 20) Mole % O2
(0 to 5) Mole % CO
2
(5 to 20) Mole % CO2
0.83 Mole %
0.83 Mole % + 0.55 % of rdg
0.48 Mole %
0.48 Mole % + 1.5 % of rdg
Extech SDL 150
oxygen meter
Vaisala MI70
w/GMP70
Gas Detection
Equipment –
O2
CO2
5 Mole % O
2
10 Mole % O2
20 Mole % O2
5 Mole % CO2
10 Mole % CO2
20 Mole % CO2
0.12 Mole %
0.23 Mole %
0.46 Mole %
0.12 Mole %
0.23 Mole %
0.46 Mole %
Certified gas
V. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Calibration of Mass
Standards – Fixed
Points
0.001 g
0.002 g
0.003 g
0.005 g
0.010 g
0.020 g
0.030 g
0.050 g
0.10 g
0.20 g
0.30 g
0.50 g
1.0 g
2.0 g
5.0 g
10 g
20 g
30 g
1.4 µg
1.2 µg
1.2 µg
1.4 µg
1.4 µg
1.5 µg
1.5 µg
1.7 µg
0.9 µg
0.8 µg
1.4 µg
1.4 µg
2.6 µg
2.7 µg
5.3 µg
8 µg
8 µg
11 µg
Mass
measurement by
appropriate mass
comparator
method (ABBA,
ABA, modified
ABA, etc.)
Troemner Ultra
Class & ASTM
Class 1 mass
pieces | ||
| 11 | ASTM Class 1; ASTM Class 3 | - | See scope document |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 12 of 16
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Pneumatic Pressure –
Measuring Equipment3
Hydraulic Gage
Pressure – Measuring
Equipment
Pressure – Measuring
Equipment
3
Vacuum – Measuring
Equipment
3
(0 to 30) inH2O
(-14 to 0) psig
(0 to 145) psig
(-14 to 0) psig
(0 to 500) psig
(0.015 to 17.5) psia
(17.5 to 35) psia
(8.75 to 17.5) psia
(50 to 10 000) psig
(0 to 1) inH
2O
(0 to 10) inH2O
(0 to 15) psi
(-14 to 200) psi
(50 to 10 000) psi
Up to 1000 mTorr
(1 to 1000) Torr
0.000 17 inH2O +
0.0001 inH2O/inH2O
0.0084 psi
0.0084 psi +
0.000 058 psi/psi
0.029 psi
0.029 psi +
0.000 059 psi/psi
0.0006 psia
0.002 psia +
0.000 056 psia/psia
0.001 psia
0.03 %
0.0036 psi
0.031 psi
0.0081 psi + 0.0001
psi/psi
0.16 psi
8.1 psi + 0.000 029
psi/psi
2.5 %
2.5 %
Fluke 7250LP
Mensor CPC6000
580DX dead weight
tester
Fluke 700P00
Fluke 700P01
Fluke 700P04
Fluke 700PD7
Fluke 700P31
MKS PVS6
Torque Wrenches
(5 to 50) ozf·in
(15 to 200) ozf·in
(4 to 50) lbf·in
(30 to 400) lbf·in
(80 to 1000) lbf·in
(20 to 250) lbf·ft
(4.4 to 44) lbf·in
(44 to 440) lbf·in
(36 to 362) lbf·ft
(60 to 600) lbf·ft
0.63 %
0.53 %
0.3 %
0.3 %
0.33 %
0.3 %
0.33 lbf·in
2.9 lbf·in
2.4 lbf·ft
0.31 %
CDI torque calibration
system
Torque Transducers
5 ozf in to 2000
lbf·ft
0.036 %
Torque arms, wheels, &
standard weights | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 13 of 16
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Infrared Temperature –
Measuring Equipment
(-15 to -12) °C
(-12 to -8) °C
(-8 to -4) °C
(-4 to 0) °C
(0 to 120) °C
(35 to 500) °C
0.51 °C
0.5 °C
0.49 °C
0.48 °C
0.6 °C + 0.0017 °C/°C
0.54 °C + ΔTChange from 35
°C x 0.0042 °C
Fluke 4180
Ɛ = (0.9 to 1.0)
λ = (8 to 14) µm
Fluke 4181
Ɛ = (0.9 to 1.0)
λ = (8 to 14) µm
Relative Humidity –
Measuring Equipment
(0 to 70) °C
(10 to 95) % RH
0.63 % RH
Thunder Scientific 2500ST-
LT
Relative Humidity –
Measure3
(10 to 90) % RH
1.6 % RH
Vaisala MI70 & HMP77
Temperature – Measure3
(-196 to 660) °C
(-196 to 660) °C
(-196 to 660) °C
(-196 to 660) °C
(660 to 1200) °C
0.0025 °C + 0.000 021
°C/ °C
0.0058 °C + 0.000 016
°C/ °C
0.0029 °C + 0.000 002
°C/ °C
0.13 °C
1.1 °C + 0.004 °C/°C
Fluke 1595A thermometer,
Fluke 5699 SPRT
Additel 286 thermometer,
Fluke 5699 SPRT
Additel 286 thermometer,
standard resistor, Fluke
5699 SPRT
Additel 286 Thermometer
w/286-TS temperature
scanner, Fluke 5699 SPRT
Thermocouple scanner
w/Type S thermocouple
probe | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 14 of 16
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature –
Measuring Equipment
Fixed Point: *
Liquid Nitrogen
Mercury
Triple Point Water
Indium
Tin
Zinc
Aluminum
Comparison**
Comparison***
Thermocouple / RTD
-195.8 °C
-38.8344 °C
0.010 °C
156.5985 °C
231.928 °C
419.527 °C
660.323 °C
(-90 to 0) °C
(0 to 200) °C
(200 to 300) °C
(300 to 400) °C
(400 to 660) °C
(-90 to -80) °C
(-80 to -5) °C
(-5 to 110) °C
(110 to 180) °C
(180 to 550) °C
(550 to 660) °C
(660 to 1200) °C
3.4 mK
2.6 mK
0.25 mK
3 mK
3.2 mK
3.5 mK
5.3 mK
0.0083 °C
0.004 °C
0.0043 °C
0.0065 °C + 0.000 078 x
Tchange from 300 °C
0.014 °C + 0.000 061 x
T
change from 400 °C
0.017 °C
0.013 °C
0.011 °C
0.016 °C + 0.000 056 x
T
change from 110 °C
0.016 °C + 0.000 052 x
Tchange from 180 °C
0.028 °C
1.2 °C + 0.0039 x Tchange
from 660 °C
Fluke miniature fixed
reference point cells,
SPRT
* PRT/SPRT with
accuracy down to 0.02 °C
(20 mK)
Fluke 1595A, Fluke 5699
PRT, calibration baths &
reference point cells
** Equipment with
accuracy down to 0.15 °C
Fluke 5628 PRT,
calibration baths &
furnaces
***Equipment with
accuracy down to 0.2 °C
Type “S” thermocouple,
calibration furnace
Temperature –
Measuring Equipment,
Thermistors
(0 to 100) °C
3.7 mK
Fluke 1595A, Fluke 5681
PRT, calibration bath | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 15 of 16
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature –
Measuring Equipment3
(0 to 150) °C
(150 to 1000) °C
(-195 to 500) °C
(20 to 60) °C
0.71 °C + 0.0007 °C/°C
1.4 °C + 0.0041 x Tchange from
150 °C
0.12 °C
0.27 °C + 0.0026 °C/°C
Fluke 741, Type T
thermocouple
Fluke 741, Type K
thermocouple
Fluke 1524, Burns
200G RTD
Vaisala MI70
w/HMP77B
Dew Point –
Measuring Equipment
(-95 to -90) °C
(-90 to -80) °C
(-80 to -70) °C
(-70 to 10) °C
(10 to 60) °C
0.93 °C
0.56 °C
0.54 °C
0.38 °C
0.44 °C
Thunder Scientific
3900 humidity
generator
Thunder Scientific
2500ST-LT
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measure
0.1 Hz to 225 MHz
5.8 µHz + 5.8 µHz/Hz
Keysight 53131A
Frequency – Measuring
Equipment
(0.01 to 15) MHz
5.8 µHz + 26 µHz/Hz
Keysight 33120A
function generator
Rotational Speed –
Optical3 – Measuring
Equipment
(2.5 to 100 000) RPM
0.000 031 RPM + 0.000
039 RPM/RPM
Fluke 5522A
RPM – Measure3
(2.5 to 100 000) RPM
1.1 RPM + 0.0058
RPM/RPM
Tachometer
Time – Measure3
Up to 36 000 sec
0.001 % of time + 37 ms
Stopwatch
Stopwatches & Timers3
(0 to 19.99) s/day
0.037 s/day
Timometer
___________________________________________
1 This laboratory offers commercial calibration service. | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2551.01) 2/12/2025 Page 16 of 16
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the measured displacement in inches; a percent refers to percent of reading
unless otherwise noted.
5 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 17 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Laboratory TestingHatfield, PA · ~4 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Maxpro CorporationHorsham, PA · ~14 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ellab, Inc.Doylestown, PA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - AllentownAllentown, PA · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Constellation PowerlabsCoatesville, PA · ~54 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.