Harman International North America Validation
30001 Cabot Dr, 48377, Novi, MI, United States
Visit website- Accredited standards
- 8
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsExclusion
Limits written next to it
Radiated Immunity – BCI ISO 11452-4 (excluding TWC Test Method)
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
CISPR 25 (2021); ISO 10605; ISO 11452-2; ISO 11452-4; ISO 11452-9; ISO 11452-8; ISO 16750-2; ISO 7637-2; ISO 7637-3 (2016)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active3085.01
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 3085.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CISPR 25 (2021); ISO 10605; ISO 11452-2; ISO 11452-4; ISO 11452-9; ISO 11452-8; ISO 16750-2; ISO 7637-2; ISO 7637-3 (2016) | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
HARMAN INTERNATIONAL NORTH AMERICA
VALIDATION LABORATORY
Novi, MI
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 23rd day of January 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3085.01
Valid to January 31, 2027
Revised January 23, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- UL LLCNovi, MI · under 1 kmA2LAShares 1 accredited test methodISO 10605
- APTIV WESTFIELD TESTWestfield, IN · ~352 kmA2LAShares 1 accredited test methodISO 10605
- Radiometrics Midwest CorporationRomeoville, IL · ~392 kmA2LAShares 1 accredited test methodISO 10605
- Compliance Management Group (CMG)Marlboro, MA · ~1,023 kmA2LAShares 1 accredited test methodISO 10605
- Element Materials Technology - MelbourneMelbourne, FL · ~1,622 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.