Registers refreshed 2026-11-20.See refresh dates
Italy

L.A.M. S.r.l. Laboratorio Analisi Microbiologiche

Via Giuseppe Di Vittorio 52, 21029, Vergiate, Italy

Visit website
ACCREDIA 00520ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
27
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 27 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO25
ISO 4832Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms - Colony-count technique
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 4833-2Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 2: Colony count at 30 °C by the surface plating technique
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 6888-1Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 1: Method using Baird-Parker agar medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 7932Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of presumptive Bacillus cereus - Colony-count technique at 30 degrees C
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 11290-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1: Detection method
ISO 11290-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 2: Enumeration method
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

Show all 25
ISO 11816-1Milk and milk products - Determination of alkaline phosphatase activity - Part 1: Fluorimetric method for milk and milk-based drinks
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 14675Milk and milk products - Guidelines for a standardized description of competitive enzyme immunoassays - Determination of aflatoxin M1 content
ISO 14698-1Cleanrooms and associated controlled environments - Biocontamination control - Part 1: General principles and methods
ISO 15214Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of mesophilic lactic acid bacteria - Colony-count technique at 30 degrees C
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
ISO 18593Microbiology of the food chain - Horizontal methods for surface sampling
ISO 19250Water quality - Detection of Salmonella spp.
ISO 19458Water quality - Sampling for microbiological analysis
ISO 21527-1Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of yeasts and moulds - Part 1: Colony count technique in products with water activity greater than 0,95
ISO 21527-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of yeasts and moulds - Part 2: Colony count technique in products with water activity less than or equal to 0,95
ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique
Other standards2
AOAC 2012.01
NF V08-061

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

3 lines
ACCREDIA

ISO/IEC 17025

Active

00520

View scope

Accredited scope, certificate 00520

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; ISO 11731:2017; ISO 19250:2010; ISO 9308-1:2014/Amd 1:2016; ISO 14189:2013; UNI EN ISO 7899-2:2003; ISO/TS 12869:2019; ISO 6222:1999; UNI 10678:1998; UNI EN ISO 16266:2008; APAT CNR IRSA 7080 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; AOAC 2012.01 2016; ISO 21527-2:2008; ISO 21527-1:2008Drinking water2 to 12
2NF V08-061:2009; ISO 15214:1998; ISO 16649-2:2001; ISO 7932:2004/Amd 1:2020; ISO 4832:2006; ISO 21528-2:2017; ISO/TS 13136:2012; AFNOR BIO 12/27-02/10; ISO 11290-2:2017; ISO 11290-1:2017; AFNOR BIO 12/33-05/12; AFNOR BIO 12/39-09/16; ISO 4833-2:2013/Cor 1:2014/Amd1:2022; ISO 4833-1:2013/Amd 1:2022; AFNOR BIO 12/38-06/16; ISO 6579-1:2017/Amd 1:2020; AFNOR BIO 12/32-10/11; ISO 6888-1:2021/Amd 1:2023; AFNOR BIO 12/25-05/09; UNI EN ISO 14675:2003; ISO 11816-1:2024; ISO/TS 11059:2009Food industry environment samples-
3ISO 19458:2006; ISO 14698-1:2003; ISO 18593:2018; UNI CEI EN ISO/IEC 17025:2018Drinking water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Giuseppe Di Vittorio 52, Vergiate, 21029, IT

45.72318, 8.71164

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.