SIMCO Electronics - Greensboro
8203-J Piedmont Triad Parkway, 27409, Greensboro, NC, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 1395.01 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 2 of 14
Parameter/Equipment
Range CMC2, 5, 6 (±) Comments
DC Current – Generate3
(0 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 11) A
(11 to 20.5) A
(20.5 to 150) A
(150 to 1000) A
0.016 % + 20 nA
0.012 % + 50 nA
0.012 % + 0.25 µA
0.012 % + 2.5 µA
0.022 % + 40 µA
0.039 % + 500 µA
0.078 % + 750 µA
0.61 % + 0.14 A
0.62 % + 0.5 A
Fluke 5522A/ SC1100
Fluke 5522A/SC1100
w/ current coil
DC Power – Generate3
0.011 mW to 20.5 kW
0.15 %
Fluke 5522A/SC1100
DC Current – Measure3
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(0.1 to 1) A
(>1 to 10) A
(>10 to 100) A
0.0029 % + 800 pA
0.0029 % + 5 nA
0.0030 % + 50 nA
0.0047 % + 500 nA
0.013 % + 10 µA
0.12 % + 3.0 µA
0.058 % + 30 µA
0.017 % + 0.30 mA
HP 3458A
Guildline 9211A/ HP
3458A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 3 of 14
Parameter/Equipment
Range CMC2, 6 (±) Comments
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.11 to 1.1) GΩ
0.0045 % + 1 mΩ
0.0037 % + 1.5 mΩ
0.0029 % + 1.4 mΩ
0.0029 % + 2 mΩ
0.0028 % + 2 mΩ
0.0028 % + 0.02 Ω
0.0028 % + 0.02 Ω
0.0028 % + 0.2 Ω
0.0028 % 0.2 Ω
0.0033 % + 2 Ω
0.0032 % + 2 Ω
0.0062 % + 30 Ω
0.013 % + 50 Ω
0.026 % + 2.5 kΩ
0.062 % + 3 kΩ
0.30 % + 100 kΩ
1.5 % + 500 kΩ
Fluke 5522A/ SC1100
Resistance – Generate3
(cont)
Fixed Points
(100 to 1000) Ω
(1 to 10) kΩ
(10 to 100) kΩ
(100 to 1000) kΩ
(1 to 10) MΩ
(10 to 100) MΩ
(10 to 100) MΩ
(100 to 1000) MΩ
(1 to 10) GΩ
(10 to 100) GΩ
0.030 % + 5 mΩ
0.035 % + 3 mΩ
0.035 % + 3 mΩ
0.035 % + 3 mΩ
0.12 % + 3 mΩ
0.12 % + 3 mΩ
0.11 % + 3 mΩ
0.28 % + 3 mΩ
0.56 % + 3 mΩ
1.2 % + 3 mΩ
IET Labs HRRS-Q-6-100
IET Labs HRRS-Q-4-
10M
Resistance – Measure3
10 mΩ to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
24 µΩ/Ω + 50 µΩ
19 µΩ/Ω + 0.5 mΩ
15 µΩ/Ω + 0.5 mΩ
15 µΩ/Ω + 5 mΩ
15 µΩ/Ω + 0.05 Ω
22 µΩ/Ω + 2 Ω
85 µΩ/Ω + 100 Ω
0.10 % + 1 kΩ
HP 3458A opt-2 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 4 of 14
Parameter/Equipment
Range CMC2, 5, 6 (±) Comments
Oscilloscopes3 –
Level Sine Amp:
50 kHz Ref.
Level Sine Flatness:
5 mV to 5.5 V
5 mV to 3.5 V
≥600 MHz Relative
to 50 kHz
Reference
Square Wave Amp
DC Signal Level
Time Marker Output
into 50 Ω
Edge Transition
Time (200 to 350) ps
Input Resistance
Measurement
5.0 mV to 5.5 V
p-p
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1000) MHz
1 mV to 130 Vp-p
1 mV to 6.6 Vp-p
Up to 130 V
Up to 6.6 V
1 ns to 20 ms
50 ms to 5 s
1 kHz to 2 MHz
(2 to 10) MHz
(40 to 60) Ω
(0.5 to 1.5) MΩ
2.2 % + 300 µV
2.2 % + 100 µV
2.2 % + 100 µV
4.1 % + 100 µV
5.1 % + 100 µV
0.10 % + 40 µV
0.25 % + 40 µV
0.050 % + 40 µV
0.27 % + 40 µV
12 s/s
(25 + 1000·t) µs/s
60 ps
90 ps
0.10 %
0.12 %
Fluke 5522A/SC1100
Into 1 MΩ load
Into 50 Ω load
Into 1 MΩ load
Into 50 Ω load
t = time in seconds | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 5 of 14
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
Thermocouples –
Generate & Measure3
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100)°C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.58 °C
0.20 °C
0.18 °C
0.20 °C
0.25 °C
0.32 °C
0.21 °C
0.19 °C
0.22 °C
0.28 °C
0.39 °C
0.22 °C
0.20 °C
0.31 °C
0.47 °C
0.73 °C
0.29 °C
0.20 °C
0.18 °C
Fluke 5522A/SC1100
Electrical Simulation of
Thermocouples –
Generate
3
Type E
Type J
Type K
Type T
(-250 to 1000) °C
(-210 to 1200) °C
(-200 to 1372) °C
(-250 to 400) °C
0.14 °C
0.14 °C
0.14 °C
0.13 °C
Fluke 5720A, burns PRT,
Omega TRP series
thermocouple reference
probes | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 6 of 14
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
Thermocouples –
Measure3
Type E
Type J
Type K
Type T
(-250 to 1000) °C
(-210 to 1200) °C
(-200 to 1372) °C
(-250 to 400) °C
0.13 °C
0.13 °C
0.13 °C
0.13 °C
HP 3458A, Burns
PRT,
Omega TRP
series
thermocouple
reference probes
Electrical Simulation of
RTD3 –
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.064 °C
0.063 °C
0.086 °C
0.11 °C
0.12 °C
0.15 °C
0.27 °C
Fluke 5522A/
SC1100
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.081 % + 6 µV
0.018 % + 6 µV
0.022 % + 6 µV
0.10 % + 6 µV
0.35 % + 12 µV
0.81 % + 50 µV
0.030 % + 8 µV
0.015 % + 8 µV
0.016 % + 8 µV
0.035 % + 8 µV
0.080 % + 32 µV
0.20 % + 70 µV
Fluke
5522A/SC1100 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 7 of 14
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Voltage – Generate3
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 450) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.035 % + 50 µV
0.015 % + 60 µV
0.019 % + 60 µV
0.030 % + 50 µV
0.070 % + 130 µV
0.24 % + 600 µV
0.030 % + 650 µV
0.016 % + 600 µV
0.024 % + 600 µV
0.035 % + 600 µV
0.09 % + 1.6 mV
0.019 % + 2.0mV
0.020 % + 6.0 mV
0.025 % + 6.0 mV
0.032 % + 6.0 mV
0.20 % + 50 mV
0.030 % + 10 mV
0.035 % + 10 mV
0.031 % + 10 mV
Fluke
5522A/SC1100 | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 8 of 14
Parameter/Range
Frequency CMC2, 5, 6 (±) Comments
AC Voltage – Measure3
(10 to 100) mV,
Locked on 100 mV
Range
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 85) kV
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
100 kHz to 1 MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
100 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
100 kHz to 1 MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 100) kHz
40 Hz to 1 kHz
60 Hz
0.009 % + 2 µV
0.016 % + 2 µV
0.092 % + 2 µV
1.2 % + 10 µV
0.0073 % + 20 µV
0.016 % + 20 µV
0.092 % + 20 µV
1.2 % + 100 µV
0.010 % + 0.4 mV
0.023 % + 0.2 mV
0.016 % + 0.2 mV
0.2 mV
1.2 % + 1.0 mV
0.020 % + 2 mV
0.023 % + 2 mV
0.14 % + 2 mV
0.041 % + 20 mV
0.62 %
HP 3458A opt-2
Ross Eng. HV
divider, HP 34401A
AC Current – Generate3
(29 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
Up to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.010 % + 27 nA
0.035 % + 95 nA
0.06 % + 95 nA
0.58 % + 0.17 µA
0.005 % + 42 nA
0.006 % + 49 nA
0.06 % + 86 nA
0.10 % + 0.24 µA
0.005 % + 0.40 µA
0.005 % + 0.50 µA
0.006 % + 0.70 µA
0.082 % + 1.1 µA
0.010 % + 25 µA
0.014 % + 36 µA
0.014 % + 36 µA
0.016 % + 41 µA
Fluke 5522A/SC1100 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 9 of 14
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Current – Generate3
(cont)
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(20.5 to 150) A
(150 to 1000) A
(20.5 to 150) A
(150 to 1000) A
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(45 to 65) Hz
(65 to 440) Hz
(65 to 440) Hz
0.019 % + 50 µA
0.20 % + 0.60 mA
0.29 % + 2.7 mA
0.028 % + 0.12 mA
0.068 % + 1.0 mA
0.36 % + 9.2 mA
0.025 % + 2.2 mA
0.013 % + 0.70 mA
1.0 % + 0.11 A
0.066 % + 3.3 mA
0.16 % + 3.5 mA
1.1 % + 0.18 A
0.25 % + 0.25 A
0.25 % + 0.9 A
0.90 % + 0.25 A
0.91 % + 0.91 A
Fluke 5522A/SC1100
Fluke 5522A/SC1100
w/ current coil | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 10 of 14
Parameter/Range
Frequency CMC2, 5, 6 (±) Comments
AC Power – Generate3
0.11 mW to 20.9 kW
(Power Factor = 1)
(45 to 65) Hz
0.10 %
Fluke 5522A/SC1100
AC Current – Measure3
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 50) A
(1 to 50) A
45 Hz to 1 kHz
45 Hz to 5 kHz
45 Hz to 5 kHz
45 Hz to 5 kHz
45 Hz to 5 kHz
60 Hz
400 Hz
0.074 % + 0.03 µA
0.037 % + 0.2 µA
0.037 % + 2 µA
0.037 % + 20 µA
0.12 % + 0.2 mA
0.25 % + 7.0 mA
0.21 % + 7.0 mA
HP 3458A opt-2
Crompton FN 50-50
current shunt/HP
3458A digital
multimeter
Parameter/Equipment
Range CMC2, 6 (±) Comments
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.71 % + 0.01 nF
0.58 % + 0.01 nF
0.58 % + 0.01 nF
0.29 % + 0.01 nF
0.29 % + 0.1 nF
0.29 % + 0.1 nF
0.29 % + 0.3 nF
0.30 % + 1 nF
0.30 % + 3 nF
0.30 % + 10 nF
0.47 % + 30 nF
0.53 % + 100 nF
0.53 % + 300 nF
0.53 % + 1 µF
0.52 % + 3 µF
0.52 % + 10 µF
0.87 % + 30 µF
1.3 % + 100 µF
Fluke 5522A/ SC1100 | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 11 of 14
II. Electrical – RF/Microwave
Parameter/Range
Frequency CMC2, 5, 6 (±) Comments
RF Absolute Power –
Measure3
Power Reference:
1 mW, Type-N (f), 50 Ω
(+20 to -30) dBm, 50 Ω
(+20 to -30) dBm, 50 Ω
(-20 to -70) dBm, 50 Ω
(+30 to -20) dBm
(+30 to -20) dBm
50 MHz
100 kHz to 4.2 GHz
10 MHz to 18 GHz
10 MHz to 18 GHz
100 kHz to 2.6 GHz
50 MHz to 26.5 GHz
0.017 dB (0.39 %)
0.12 dB (2.7 %)
0.081 dB (1.9 %)
0.11 dB (2.5 %)
0.072 dB (1.7 %)
0.22 dB (5.3 %)
HP 432A w/ HP
478A-H75
HP 8482A w/ HP
438A
HP 8481A w/ HP
438A
HP 8481D w/ HP
438A
HP 11722A w/ HP
8902A
HP 11792A w/ HP
8902A | 20 to -70 dBm |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 12 of 14
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Distortion – Measure3
(-80 to 0) dB
(-65 to 0) dB
CW Input ≥ -13 dB
(-90 to 0) dB
CW Input ≥ -13 dB
20 Hz to <20 kHz
(20 to 100) kHz
100 kHz to 13.25 GHz
1.0 dB
2.0 dB
3.8 dB
HP 8903B distortion
analyzer
HP 8563E spectrum
analyzer
RF Absolute Power –
Generate3
Sine Wave into 50 Ω:
(10 to 3) Vp-p
(2.99 to 1) mVp-p
Sine Wave into 50 Ω:
(+13 to -3010) dBm
(-20 to -70 dBm)
Sine Wave into 50 Ω:
(+11.5to -20) dBm
(+8 to -20) dBm
1 Hz to 100 kHz
1 Hz to 100 kHz
100 kHz to 2 GHz
10 MHz to 18 GHz
10 MHz to 20 GHz
20 GHz to 26.5 GHz
3.0 %
1.1 %
0.15 dB
0.15 dB
0.19 dB
0.19 dB
HP 3325B,
Agilent 3458A
HP 8657A
HP 83630B
HP 438
HP 8481D
HP 83630B
HP 8902A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 13 of 14
III. Mechanical
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Pressure/Vacuum –
Measure
(-15 to 30) psig
(0 to 50) psia
(-15 to 100) psig
(-15 to 500) psig
(-15 to 1000) psig
(0 to 10 000) psig
930 psi
930 psi
290 psi
0.19 psi
0.25 psi
10 psi
Heise DXD-50
Heise DXD-50
Additel ADT160A-02-
CP100-PSI-N
Additel ADT160A-02-
CP500-PSI-N
Additel ADT160A-02-
CPIK-PSI-N
Additel ADT680-10-
GP10K-PSI-N2
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature – Measure3
(-196 to 420) o C
0.089 o C
Burns Eng. PRT 18332, HP
3458A
Temperature – Measuring
Equipment3
(0 to Ambient) °C
(Ambient to 300) °C
(>300 to 420) °C
(16 to 32) °C
0.14 o C
0.16 o C
0.53 °C
0.14 °C
Burns Eng. PRT 18332,
HP 3458A, temperature
blocks
Vaisala HMP-155 & RH
chamber
Relative Humidity –
Measuring Equipment
(25 to 90) % RH
1.2 % RH
Vaisala HMP-155 & RH
chamber
Relative Humidity –
Measure3
(11 to 95) % RH
1.3 % RH
Vaisala HMI41/HMP46 | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.01) 11/26/2025 Page 14 of 14
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Frequency – Measuring
Equipment3
20 MHz to 3 GHz
(3 to 26.5) GHz
(1.3 x 10-10) Hz/Hz
(1.2 x 10 -6) Hz/Hz
HP 83630B
Frequency – Measure3
(3 to 26.5) GHz
(1.2 x 10 -6) Hz/Hz
HP 5351B
Stopwatches & Timers3
1 s to 24 hr
0.034 s/day
Helmut Klein 4500
timometer
____________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and
Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level
of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 “The contributions from the “best existing device” are not included in the CMC claim.” (A2LA R205)
5 In the statement of CMC, R is the resolution of the unit under test; percentages are percent of reading,
unless otherwise indicated; L is the numerical value of the nominal length of the device in inches.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - Winston-SalemWinston-Salem, NC · ~41 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MSI-Viking GageDanville, VA · ~68 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MSI-Viking Gage, LLC.Durham, NC · ~80 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Troxler Electronic Laboratories, Inc.Research Triangle Park, NC · ~86 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - MORRISVILLEMorrisville, NC · ~91 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.