United States

SIMCO Electronics - Greensboro

8203-J Piedmont Triad Parkway, 27409, Greensboro, NC, United States

Visit website
A2LA 1395.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 1395.01 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 2 of 14 Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Current – Generate3 (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 11) A (11 to 20.5) A (20.5 to 150) A (150 to 1000) A 0.016 % + 20 nA 0.012 % + 50 nA 0.012 % + 0.25 µA 0.012 % + 2.5 µA 0.022 % + 40 µA 0.039 % + 500 µA 0.078 % + 750 µA 0.61 % + 0.14 A 0.62 % + 0.5 A Fluke 5522A/ SC1100 Fluke 5522A/SC1100 w/ current coil DC Power – Generate3 0.011 mW to 20.5 kW 0.15 % Fluke 5522A/SC1100 DC Current – Measure3 (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (0.1 to 1) A (>1 to 10) A (>10 to 100) A 0.0029 % + 800 pA 0.0029 % + 5 nA 0.0030 % + 50 nA 0.0047 % + 500 nA 0.013 % + 10 µA 0.12 % + 3.0 µA 0.058 % + 30 µA 0.017 % + 0.30 mA HP 3458A Guildline 9211A/ HP 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 3 of 14 Parameter/Equipment Range CMC2, 6 (±) Comments Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.11 to 1.1) GΩ 0.0045 % + 1 mΩ 0.0037 % + 1.5 mΩ 0.0029 % + 1.4 mΩ 0.0029 % + 2 mΩ 0.0028 % + 2 mΩ 0.0028 % + 0.02 Ω 0.0028 % + 0.02 Ω 0.0028 % + 0.2 Ω 0.0028 % 0.2 Ω 0.0033 % + 2 Ω 0.0032 % + 2 Ω 0.0062 % + 30 Ω 0.013 % + 50 Ω 0.026 % + 2.5 kΩ 0.062 % + 3 kΩ 0.30 % + 100 kΩ 1.5 % + 500 kΩ Fluke 5522A/ SC1100 Resistance – Generate3 (cont) Fixed Points (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ (100 to 1000) kΩ (1 to 10) MΩ (10 to 100) MΩ (10 to 100) MΩ (100 to 1000) MΩ (1 to 10) GΩ (10 to 100) GΩ 0.030 % + 5 mΩ 0.035 % + 3 mΩ 0.035 % + 3 mΩ 0.035 % + 3 mΩ 0.12 % + 3 mΩ 0.12 % + 3 mΩ 0.11 % + 3 mΩ 0.28 % + 3 mΩ 0.56 % + 3 mΩ 1.2 % + 3 mΩ IET Labs HRRS-Q-6-100 IET Labs HRRS-Q-4- 10M Resistance – Measure3 10 mΩ to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 24 µΩ/Ω + 50 µΩ 19 µΩ/Ω + 0.5 mΩ 15 µΩ/Ω + 0.5 mΩ 15 µΩ/Ω + 5 mΩ 15 µΩ/Ω + 0.05 Ω 22 µΩ/Ω + 2 Ω 85 µΩ/Ω + 100 Ω 0.10 % + 1 kΩ HP 3458A opt-2
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 4 of 14 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Oscilloscopes3 – Level Sine Amp: 50 kHz Ref. Level Sine Flatness: 5 mV to 5.5 V 5 mV to 3.5 V ≥600 MHz Relative to 50 kHz Reference Square Wave Amp DC Signal Level Time Marker Output into 50 Ω Edge Transition Time (200 to 350) ps Input Resistance Measurement 5.0 mV to 5.5 V p-p 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1000) MHz 1 mV to 130 Vp-p 1 mV to 6.6 Vp-p Up to 130 V Up to 6.6 V 1 ns to 20 ms 50 ms to 5 s 1 kHz to 2 MHz (2 to 10) MHz (40 to 60) Ω (0.5 to 1.5) MΩ 2.2 % + 300 µV 2.2 % + 100 µV 2.2 % + 100 µV 4.1 % + 100 µV 5.1 % + 100 µV 0.10 % + 40 µV 0.25 % + 40 µV 0.050 % + 40 µV 0.27 % + 40 µV 12 s/s (25 + 1000·t) µs/s 60 ps 90 ps 0.10 % 0.12 % Fluke 5522A/SC1100 Into 1 MΩ load Into 50 Ω load Into 1 MΩ load Into 50 Ω load t = time in seconds
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 5 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples – Generate & Measure3 Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100)°C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.58 °C 0.20 °C 0.18 °C 0.20 °C 0.25 °C 0.32 °C 0.21 °C 0.19 °C 0.22 °C 0.28 °C 0.39 °C 0.22 °C 0.20 °C 0.31 °C 0.47 °C 0.73 °C 0.29 °C 0.20 °C 0.18 °C Fluke 5522A/SC1100 Electrical Simulation of Thermocouples – Generate 3 Type E Type J Type K Type T (-250 to 1000) °C (-210 to 1200) °C (-200 to 1372) °C (-250 to 400) °C 0.14 °C 0.14 °C 0.14 °C 0.13 °C Fluke 5720A, burns PRT, Omega TRP series thermocouple reference probes
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 6 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples – Measure3 Type E Type J Type K Type T (-250 to 1000) °C (-210 to 1200) °C (-200 to 1372) °C (-250 to 400) °C 0.13 °C 0.13 °C 0.13 °C 0.13 °C HP 3458A, Burns PRT, Omega TRP series thermocouple reference probes Electrical Simulation of RTD3 – Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.064 °C 0.063 °C 0.086 °C 0.11 °C 0.12 °C 0.15 °C 0.27 °C Fluke 5522A/ SC1100 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.081 % + 6 µV 0.018 % + 6 µV 0.022 % + 6 µV 0.10 % + 6 µV 0.35 % + 12 µV 0.81 % + 50 µV 0.030 % + 8 µV 0.015 % + 8 µV 0.016 % + 8 µV 0.035 % + 8 µV 0.080 % + 32 µV 0.20 % + 70 µV Fluke 5522A/SC1100
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 7 of 14 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Generate3 (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 450) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.035 % + 50 µV 0.015 % + 60 µV 0.019 % + 60 µV 0.030 % + 50 µV 0.070 % + 130 µV 0.24 % + 600 µV 0.030 % + 650 µV 0.016 % + 600 µV 0.024 % + 600 µV 0.035 % + 600 µV 0.09 % + 1.6 mV 0.019 % + 2.0mV 0.020 % + 6.0 mV 0.025 % + 6.0 mV 0.032 % + 6.0 mV 0.20 % + 50 mV 0.030 % + 10 mV 0.035 % + 10 mV 0.031 % + 10 mV Fluke 5522A/SC1100
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 8 of 14 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure3 (10 to 100) mV, Locked on 100 mV Range 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V (1 to 85) kV 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz 100 kHz to 1 MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz 100 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz 100 kHz to 1 MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz 40 Hz to 1 kHz 60 Hz 0.009 % + 2 µV 0.016 % + 2 µV 0.092 % + 2 µV 1.2 % + 10 µV 0.0073 % + 20 µV 0.016 % + 20 µV 0.092 % + 20 µV 1.2 % + 100 µV 0.010 % + 0.4 mV 0.023 % + 0.2 mV 0.016 % + 0.2 mV 0.2 mV 1.2 % + 1.0 mV 0.020 % + 2 mV 0.023 % + 2 mV 0.14 % + 2 mV 0.041 % + 20 mV 0.62 % HP 3458A opt-2 Ross Eng. HV divider, HP 34401A AC Current – Generate3 (29 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Up to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.010 % + 27 nA 0.035 % + 95 nA 0.06 % + 95 nA 0.58 % + 0.17 µA 0.005 % + 42 nA 0.006 % + 49 nA 0.06 % + 86 nA 0.10 % + 0.24 µA 0.005 % + 0.40 µA 0.005 % + 0.50 µA 0.006 % + 0.70 µA 0.082 % + 1.1 µA 0.010 % + 25 µA 0.014 % + 36 µA 0.014 % + 36 µA 0.016 % + 41 µA Fluke 5522A/SC1100
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 9 of 14 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current – Generate3 (cont) (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (20.5 to 150) A (150 to 1000) A (20.5 to 150) A (150 to 1000) A 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz 0.019 % + 50 µA 0.20 % + 0.60 mA 0.29 % + 2.7 mA 0.028 % + 0.12 mA 0.068 % + 1.0 mA 0.36 % + 9.2 mA 0.025 % + 2.2 mA 0.013 % + 0.70 mA 1.0 % + 0.11 A 0.066 % + 3.3 mA 0.16 % + 3.5 mA 1.1 % + 0.18 A 0.25 % + 0.25 A 0.25 % + 0.9 A 0.90 % + 0.25 A 0.91 % + 0.91 A Fluke 5522A/SC1100 Fluke 5522A/SC1100 w/ current coil
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 10 of 14 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Power – Generate3 0.11 mW to 20.9 kW (Power Factor = 1) (45 to 65) Hz 0.10 % Fluke 5522A/SC1100 AC Current – Measure3 (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 50) A (1 to 50) A 45 Hz to 1 kHz 45 Hz to 5 kHz 45 Hz to 5 kHz 45 Hz to 5 kHz 45 Hz to 5 kHz 60 Hz 400 Hz 0.074 % + 0.03 µA 0.037 % + 0.2 µA 0.037 % + 2 µA 0.037 % + 20 µA 0.12 % + 0.2 mA 0.25 % + 7.0 mA 0.21 % + 7.0 mA HP 3458A opt-2 Crompton FN 50-50 current shunt/HP 3458A digital multimeter Parameter/Equipment Range CMC2, 6 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.71 % + 0.01 nF 0.58 % + 0.01 nF 0.58 % + 0.01 nF 0.29 % + 0.01 nF 0.29 % + 0.1 nF 0.29 % + 0.1 nF 0.29 % + 0.3 nF 0.30 % + 1 nF 0.30 % + 3 nF 0.30 % + 10 nF 0.47 % + 30 nF 0.53 % + 100 nF 0.53 % + 300 nF 0.53 % + 1 µF 0.52 % + 3 µF 0.52 % + 10 µF 0.87 % + 30 µF 1.3 % + 100 µF Fluke 5522A/ SC1100
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 11 of 14 II. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 5, 6 (±) Comments RF Absolute Power – Measure3 Power Reference: 1 mW, Type-N (f), 50 Ω (+20 to -30) dBm, 50 Ω (+20 to -30) dBm, 50 Ω (-20 to -70) dBm, 50 Ω (+30 to -20) dBm (+30 to -20) dBm 50 MHz 100 kHz to 4.2 GHz 10 MHz to 18 GHz 10 MHz to 18 GHz 100 kHz to 2.6 GHz 50 MHz to 26.5 GHz 0.017 dB (0.39 %) 0.12 dB (2.7 %) 0.081 dB (1.9 %) 0.11 dB (2.5 %) 0.072 dB (1.7 %) 0.22 dB (5.3 %) HP 432A w/ HP 478A-H75 HP 8482A w/ HP 438A HP 8481A w/ HP 438A HP 8481D w/ HP 438A HP 11722A w/ HP 8902A HP 11792A w/ HP 8902A
20 to -70 dBm
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 12 of 14 Parameter/Range Frequency CMC2, 6 (±) Comments Distortion – Measure3 (-80 to 0) dB (-65 to 0) dB CW Input ≥ -13 dB (-90 to 0) dB CW Input ≥ -13 dB 20 Hz to <20 kHz (20 to 100) kHz 100 kHz to 13.25 GHz 1.0 dB 2.0 dB 3.8 dB HP 8903B distortion analyzer HP 8563E spectrum analyzer RF Absolute Power – Generate3 Sine Wave into 50 Ω: (10 to 3) Vp-p (2.99 to 1) mVp-p Sine Wave into 50 Ω: (+13 to -3010) dBm (-20 to -70 dBm) Sine Wave into 50 Ω: (+11.5to -20) dBm (+8 to -20) dBm 1 Hz to 100 kHz 1 Hz to 100 kHz 100 kHz to 2 GHz 10 MHz to 18 GHz 10 MHz to 20 GHz 20 GHz to 26.5 GHz 3.0 % 1.1 % 0.15 dB 0.15 dB 0.19 dB 0.19 dB HP 3325B, Agilent 3458A HP 8657A HP 83630B HP 438 HP 8481D HP 83630B HP 8902A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 13 of 14 III. Mechanical Parameter/Equipment Range CMC2, 8 (±) Comments Pressure/Vacuum – Measure (-15 to 30) psig (0 to 50) psia (-15 to 100) psig (-15 to 500) psig (-15 to 1000) psig (0 to 10 000) psig 930 psi 930 psi 290 psi 0.19 psi 0.25 psi 10 psi Heise DXD-50 Heise DXD-50 Additel ADT160A-02- CP100-PSI-N Additel ADT160A-02- CP500-PSI-N Additel ADT160A-02- CPIK-PSI-N Additel ADT680-10- GP10K-PSI-N2 IV. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measure3 (-196 to 420) o C 0.089 o C Burns Eng. PRT 18332, HP 3458A Temperature – Measuring Equipment3 (0 to Ambient) °C (Ambient to 300) °C (>300 to 420) °C (16 to 32) °C 0.14 o C 0.16 o C 0.53 °C 0.14 °C Burns Eng. PRT 18332, HP 3458A, temperature blocks Vaisala HMP-155 & RH chamber Relative Humidity – Measuring Equipment (25 to 90) % RH 1.2 % RH Vaisala HMP-155 & RH chamber Relative Humidity – Measure3 (11 to 95) % RH 1.3 % RH Vaisala HMI41/HMP46
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.01) 11/26/2025 Page 14 of 14 V. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measuring Equipment3 20 MHz to 3 GHz (3 to 26.5) GHz (1.3 x 10-10) Hz/Hz (1.2 x 10 -6) Hz/Hz HP 83630B Frequency – Measure3 (3 to 26.5) GHz (1.2 x 10 -6) Hz/Hz HP 5351B Stopwatches & Timers3 1 s to 24 hr 0.034 s/day Helmut Klein 4500 timometer ____________________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 “The contributions from the “best existing device” are not included in the CMC claim.” (A2LA R205) 5 In the statement of CMC, R is the resolution of the unit under test; percentages are percent of reading, unless otherwise indicated; L is the numerical value of the nominal length of the device in inches. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
15ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

8203-J Piedmont Triad Parkway, Greensboro, NC, 27409, US

36.07264, -79.79198

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.