United States

Primary Instruments

9553 Vassar Avenue, 91311, Chatsworth, CA, United States

Visit website
A2LA 2011.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
18
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 18 scope lines.

A2LA certificate 2011.01 · 18 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 2 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Gage Blocks (0.01 to 0.95) in (1 to 4) in (0.5 to 5) mm (>5 to 10) mm (>10 to 20) mm (>20 to 25) mm (>25 to 50) mm (>50 to 75) mm (>75 to 100) mm 5 in 6 in 7 in 8 in 10 in 12 in 16 in 20 in (2.3 + 0.9L) μin (2.3 + 1.1L) μin 0.056 μm 0.077 μm 0.077 μm 0.089 μm 0.12 μm 0.14 μm 0.18 μm 14 μin 20 μin 20 μin 21 μin 21 μin 21 μin 25 μin 35 μin Master gage block set mechanical comparator Federal 130B-24 Master gage block set mechanical comparator Federal 130B-16 Micrometers3, 8 – Outside, Inside, & Depth Up to 40 in (6.7 + 2.4L) μin Gage blocks Height Masters Up to 12 in (12 to 24) in 22 μin 37 μin Gage blocks Height Gages3, 8 Up to 40 in (31 + 1.2L) µin Gage blocks Mu-Checker/Electronic Height Gage ± 0.000 15 in ± 0.0005 in ± 0.0015 in ± 0.005 in ± 0.015 in ± 0.05 in 4.7 μin 6.9 μin 29 μin 58 μin 0.000 29 in 0.000 58 in Gage blocks
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 3 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Plain Ring Gages – Up to Class X, XX, XXX (0.04 to 1) in (1 to 2) in (2 to 3) in (3 to 4) in (4 to 5) in (5 to 6) in (6 to 7) in (7 to 8) in (8 to 9) in (9 to 10) in (10 to 11) in (11 to 12) in 5.3 μin 6.5 μin 7.1 μin 8.2 μin 15 μin 21 μin 21 μin 22 μin 22 μin 22 μin 33 μin 33 μin Pratt & Whitney LabmasterTM Inside Diameter – Dial & Digital Bore Gages, Holtest, IntrimikV (0.04 to 12) in (17 + 1.4D) μin Lab Master plus master ring gages & gage blocks Dial & Test Indicators3, 8 Up to 0.5 in Up to 4 in 37 μin 0.000 18 in Gage blocks Digital Indicators3, 8 Up to 2 in (2 to 4) in (11 + 0.92L) µin (20 + 1.1L) µin Gage blocks Indicator Calibrator – Resolution: 0.0001 in 0.000 05 in 0.000 01 in Up to 1 in 68 μin 34 μin 7.2 μin Gage blocks Depth Gage3, 8 Up to 12 in 93 μin Gage blocks Feeler Gage/Thickness Specimen (0.0005 to 0.2) in 26 µin Pratt & Whitney SupermicrometerTM Thread Wire Set (4.5 to 80) TPI 5.9 µin Master wire set
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 4 of 17 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Thread Plug Gages – Pitch Diameter Major Diameter (4.5 to 80) TPI Up to 10 in 8 µin 10 µin Thread wire set & Pratt & Whitney LabmasterTM Adjustable Thread Rings6 (0.08 to 3) in Diameter Set Plug Tolerance Master threaded plug set End Standards (1 to 40) in (11 + 1.4L) µin Gage blocks with Mu- Checker V Blocks (Parallelism) Up to 8 in 14 µin Mu checker with lever head probe Cylindrical Plug Gages (0.005 to 1) in (1 to 2) in (2 to 3) in (3 to 4) in (4 to 5) in (5 to 6) in (6 to 7) in (7 to 8) in (8 to 9) in (9 to 10) in (10 to 11) in (11 to 12) in 5.6 µin 6.3 µin 7.6 µin 9.0 µin 16 µin 21 µin 22 µin 23 µin 24 µin 34 µin 25 µin 25 µin Gage blocks & Pratt & Whitney LabmasterTM Optical Comparator3 – Linear Travel Magnification Up to 8 in 10x to 50x 66 μin 0.12 % Gage blocks Glass scales Toolmakers Microscopes3 – Linear Travel Up to 12 in (93 + 4.0L) µin Glass scales Optical Flats/Parallels – Flatness Parallelism Up to 6 in Up to 6 in 3.2 µin 4.9 µin Master optical flat Mechanical comparator
to 80 in
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 5 of 17 Parameter/Equipment Range CMC2 (±) Comments Granite Surface Plates3 Flatness Repeatability (2 to 18) in Up to (48 x 72) in TIR ±0.002 in 48 μin 49 μin 29 µin Gage blocks & Mu Checker Autocollimator Repeat-o-meter (TIR means test indicator range) Autocollimator (0 to 60) arc-minutes 0.42 arc-sec Adjustable sine plate III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 7, 8 (±) Comments DC V oltage3 – Generate Fixed Point (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1000) V 10 V 11 µV/V + 0.80 µV 10 µV/V + 1.2 µV 10 µV/V + 4.0 µV 10 µV/V + 8.0 µV 10 µV/V + 0.10 mV 12 µV/V + 0.60 mV 2.3 µV/V Fluke 5700A Fluke 732B DC V oltage3 – Measure 100 mV 1 V 10 V 100 V 1000 V (1000 to 5000) V 15 µV/V + 0.30 µV 14 µV /V + 0.30 µV 14 µV /V + 0.50 µV 14 µV /V + 30 µV 14 µV/V + 0.10 mV* 0.067 % + 0.080 V HP 3458A, opt 002 *add 12 µV/V (Vin/1000)2 for Vin >100 V Vitrek 4700 DC Current3 – Generate (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (>11 to 20) A 60 µA /A + 0.010 µA 60 µA /A + 0.010 µA 60 µA /A + 0.10 µ A 69 µA /A + 1.0 µA 0.0093 % + 30 µA 0.039 % + 0.50 mA 0.079 % + 0.75 mA Fluke 5700A Fluke 5520A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 6 of 17 Parameter/Equipment Range CMC2, 5, 7 (±) Comments DC Current3 – Measure 100 μA 1 mA 10 mA 100 mA 1 A (1 to 15) A (1 to 100) A 35 µA /A + 0.80 nA 35 µA /A + 0.0050 µA 35 µA/A + 0.050 µA 53 µA/A + 0.50 µA 0.014 % + 10 µA 0.048 % 0.049 % HP 3458A, opt 002 L&N 4360 shunt L&N 4361 shunt DC Resistance – Generate, Fixed Points 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 26 μΩ/Ω 13 μΩ/Ω 13 μΩ/Ω 1.3 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω L&N 4223-B L&N 4222 L&N 4221 Thomas 4210 L&N Rosa 4025-B L&N Rosa 4030-B L&N Rosa 4035-B L&N Rosa 4214 L&N Rosa 4045-B L&N Rosa 4050-B Guildline 9330-10M DC Resistance3 – Generate, Fixed Points 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 0.012 % 0.011 % 34 μΩ/Ω 34 μΩ/Ω 22 μΩ/Ω 20 μΩ/Ω 15 μΩ/Ω 15 μΩ/Ω 15 μΩ/Ω 15 μΩ/Ω 17 μΩ/Ω 17 μΩ/Ω 24 μΩ/Ω 26 μΩ/Ω 51 μΩ/Ω 61 μΩ/Ω 0.013 % Fluke 5700A DC Resistance3 – Measure 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 28 μΩ/Ω + 0.10 mΩ 28 μΩ/Ω + 1.0 mΩ 21 μΩ/Ω + 1.0 mΩ 21 μΩ/Ω + 10 mΩ 21 μΩ/Ω + 0.10 Ω 27 μΩ/Ω + 4.0 Ω 92 μΩ/Ω + 0.10 kΩ 0.12 % + 1.0 kΩ HP 3458A opt 002
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 7 of 17 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Inductance – Measure @ 1 kHz 100 µH (1, 10, 100, 1000) mH 0.30 % 0.13 % GenRad 1689M bridge Inductance – Generate, Fixed Points @ 1 kHz 100 μH 1 mH 10 mH 100 mH 1 H 0.29 % 0.12 % 0.12 % 0.12 % 0.12 % GenRad 1482B GenRad 1482E GenRad 1482H GenRad 1482L GenRad 1482P Capacitance – Generate, Fixed Values @ 1 kHz 10 pF 100 pF 1000 pF 0.0040 % 0.0026 % 0.0024 % GenRad 1404-C GenRad 1404-B GenRad 1404-A Capacitance – Measure @ 1 kHz (10 to 100) pF (100 to 1000) pF 1000 pF 0.0070 % 0.0063 % 0.0062 % GenRad 1689M bridge Parameter/Range Frequency CMC2, 7 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) μF (1.1 to 3.299 99) μF (3.3 to 10.9999) μF (11 to 32.9999) μF (33 to 109.999) μF (110 to 329.999) μF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110.00) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.47 % + 0.010 nF 0.47 % + 0.010 nF 0.47 % + 0.010 nF 0.28 % + 0.010 nF 0.28 % + 0.10 nF 0.28 % + 0.10 nF 0.28 % + 0.30 nF 0.28 % + 1.0 nF 0.28 % + 3.0 nF 0.28 % + 10 nF 0.37 % + 30 nF 0.63 % + 0.10 μF 0.35 % + 0.30 μF 0.35 % + 1.0 μF 0.35 % + 3.0 μF 0.36 % + 10 μF 0.61 % + 30 μF 0.96 % + 0.10 mF Fluke 5520A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 8 of 17 Parameter/Range Frequency CMC2, 5, 7 (±) Comments AC V oltage3 – Generate (0 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.065 % + 5.0 μV 0.085 % + 5.0 μV 0.046 % + 5.0 μV 0.052 % + 5.0 μV 0.10 % + 8.0 μV 0.15 % + 15 μV 0.28 % + 30 μV 0.52 % + 40 μV 0.055 % + 6.0 μV 0.024 % + 6.0 μV 0.013 % + 6.0 μV 0.038 % + 6.0 μV 0.086 % + 8.0 μV 0.12 % + 15 μV 0.18 % + 30 μV 0.34 % + 25 μV 0.054 % + 16 μV 0.022 % + 10 μV 0.011 % + 10 μV 0.033 % + 10 μV 0.082 % + 30 μV 0.10 % + 30 μV 0.18 % + 40 μV 0.34 % + 0.10 mV 0.054 % + 0.10 mV 0.016 % + 30 μV 0.0092 % + 7.0 μV 0.013 % + 20 μV 0.027 % + 80 μV 0.048 % + 0.15 mV 0.13 % + 0.40 mV 0.23 % + 1.0 mV 0.054 % + 1.0 mV 0.016 % + 0.30 mV 0.0093 % + 70 μV 0.014 % + 0.20 mV 0.027 % + 0.40 mV 0.061 % + 1.7 mV 0.14 % + 5.0 mV 0.28 % + 9.0 mV Fluke 5700A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 9 of 17 Parameter/Range Frequency CMC2, 7 (±) Comments AC V oltage3 – Generate (cont) (22 to 220) V (220 to 1000) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 50 Hz to 1 kHz 0.054 % + 10 mV 0.017 % + 3.0 mV 0.0096 % + 1.0 mV 0.024 % + 4.0 mV 0.055 % + 10 mV 0.0097 % + 4.0 mV Fluke 5700A AC V oltage3 – Measure, 10 mV 100 mV 1 V 10 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.036 % + 3.0 μV 0.024 % + 1.1 μV 0.035 % + 1.1 μV 0.12 % + 1.1 μV 0.58 % + 1.1 μV 4.6 % + 2.0 μV 0.0088 % + 4.0 μV 0.0083 % + 2.0 μV 0.016 % + 2.0 μV 0.039 % + 2.0 μV 0.094 % + 2.0 μV 0.35 % + 10 μV 1.2 % + 10 μV 0.0084 % + 40 μV 0.0082 % + 20 μV 0.016 % + 20 μV 0.035 % + 20 μV 0.093 % + 20 μV 0.35 % + 0.10 mV 1.2 % + 0.10 mV 0.0084 % + 0.40 mV 0.0082 % + 0.20 mV 0.017 % + 0.20 mV 0.035 % + 0.20 mV 0.092 % + 0.20 mV 0.35 % + 1.0 mV 1.2 % + 1.0 mV HP 3458A, opt 002
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 10 of 17 Parameter/Range Frequency CMC2, 7 (±) Comments AC V oltage3 – Measure (cont) 100 V 700 V (700 to 1000) V (1000 to 5000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (50 to 400) Hz 60 Hz 0.023 % + 4.0 mV 0.023 % + 2.0 mV 0.024 % + 2.0 mV 0.041 % + 2.0 mV 0.14 % + 2.0 mV 0.46 % + 10 mV 0.046 % + 20 mV 0.069 % + 20 mV 0.15 % + 0.11 V 0.15 % + 0.15 V HP 3458A, opt 002 Vitrek 4700 AC Current3 – Generate (9 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.074 % + 30 nA 0.039 % + 25 nA 0.017 % + 20 nA 0.072 % + 50 nA 0.17 % + 0.10 µA 0.074 % + 50 nA 0.038 % + 40 nA 0.016 % + 40 nA 0.070 % + 0.50 µA 0.16 % + 1.0 µA 0.074 % + 0.50 µA 0.038 % + 0.40 µA 0.016 % + 0.40 µA 0.070 % + 5.0 µA 0.16 % + 10 µA 0.074 % + 5.0 µA 0.038 % + 4.0 µA 0.020 % + 4.0 µA 0.070 % + 50 µA 0.16 % + 0.10 mA 0.070 % + 40 µA 0.079 % + 0.10 mA 0.94 % + 0.20 mA Fluke 5700A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 11 of 17 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (cont) (2.2 to 10.9999) A (11 to 20) A (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz 0.048 % + 2.0 mA 0.079 % + 2.0 mA 2.3 % + 2.0 mA 0.094 % + 5.0 mA 0.13 % + 5.0 mA 2.6 % + 5.0 mA Fluke 5520A AC Current – Measure 100 μA 1 mA 10 mA 100 mA 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz 0.46 % + 0.030 μA 0.17 % + 0.030 μA 0.070 % + 0.030 μA 0.070 % + 0.030 μA 0.46 % + 0.20 μA 0.17 % + 0.20 μA 0.070 % + 0.20 μA 0.035 % + 0.20 μA 0.070 % + 0.20 μA 0.46 % + 2.0 μA 0.17 % + 2.0 μA 0.070 % + 2.0 μA 0.035 % + 2.0 μA 0.070 % + 2.0 μA 0.46 % + 20 μA 0.17 % + 20 μA 0.070 % + 20 μA 0.035 % + 20 μA 0.071 % + 20 μA 0.46 % + 0.20 mA 0.19 % + 0.20 mA 0.093 % + 0.20 mA 0.12 % + 0.20 mA 0.35 % + 0.20 mA HP 3458A opt 002
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 12 of 17 Parameter/Equipment Range CMC2, 7 (±) Comments Oscilloscopes3 – Level Sine Wave @ 50 kHz Reference Level Sine Flatness 5 mV to 5.5 V Vertical Gain DC – Into 50 Ω Into 1 MΩ Square Wave – Into 50 Ω Into 1 MΩ Time Marker Output Into 50 Ω Edge Rise Time 5 mV to 2.5 V(p-p) 5 mV to 5.5 V(p-p) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (0 to 6.6) V (0 to 130) V 1 mV to 6.6 V(p-p) 1 mV to 130 V(p-p) 5 s to 50 ms 20 ms to 2 ns ≤350 ps 2.3 % + 0.30 mV 2.1 % + 0.10 mV 2.6 % + 0.10 mV 4.8 % + 0.10 mV 0.30 % + 40 µV 0.060 % + 40 µV 0.30 % + 40 µV 0.13 % + 40 µV (31 + t*1000) µs/s 2.9 µs/s +0 ps/-59 ps Fluke 5520A/SC600 t = time in seconds Electrical Simulation of Thermocouple Indicating Devices3 – Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.40 °C 0.15 °C 0.13 °C 0.17 °C 0.20 °C 0.22 °C 0.15 °C 0.13 °C 0.17 °C 0.21 °C 0.29 °C 0.17 °C 0.15 °C 0.23 °C 0.33 °C 0.50 °C 0.20 °C 0.15 °C 0.16 °C Fluke 5520A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 13 of 17 I V. Electrical – RF/Microwave Parameter/Equipment Frequency CMC2, 5, 7 (±) Comments RF Power Sensors3 0.1 MHz to 8 GHz (8 to 12) GHz (12 to 18) GHz 2.0 % CF 2.2 % CF 2.3 % CF Tegam 1827 CF = calibration factor RF Power 3 – Measure (@ 0 dBm) 10 MHz 50 MHz to 7 GHz 8 GHz (9 to 10) GHz 1.5 % + M 2.5 % + M 2.3 % + M 2.5 % + M HP 478A w/ HP 432A M = mismatch on both ports V. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Scales & Balances3 – Linearity & Shift Test Only Resolution: 0.000 002 g 0.000 01 g 0.0001 g 0.001 g Resolution: 0.0001 g 0.001 g 0.01 g 0.1 g Resolution: 0.001 lb 0.01 lb 0.1 lb 1 mg to 3 g 1 mg to 200 g 200 g to 20 kg 2 oz to 2000 lb 0.0051 mg 0.050 mg 0.076 mg 0.58 mg 0.076 mg 0.58 mg 7.7 mg 58 mg 0.0023 lb 0.0062 lb 0.058 lb Class 1 weights Class 1 weights Class F weights Torque Wrenches & Screwdrivers3 0.5 ozf·in to 200 lbf·in 37.5 lbf·in to 2000 lbf·ft 0.085 % 0.070 % CDI 2000-011-0H CDI 2000-610-02 Torque Transducers 0.5 ozf·in to 200 lbf·in (37.5 to 2000) lbf·ft 0.049 % 0.048 % Calibrated weights & torque arms
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 14 of 17 Parameter/Equipment Range CMC2, 5, 9 (±) Comments Pressure – Measuring Equipment Pneumatic Vacuum Absolute Hydraulic Up to 1000 psig Up to 10 000 psig Up to 30 psig Down to -14.0 psig (1.7 to <8) psia (8 to 16) psia (60 to 40 000) psig 0.020 % 0.010 % 0.019 % 0.019 % 0.029 % 0.017 % 0.012 % DHI PPC3 DHI 5203 DHI RPM3 DHI RPM3 Mensor 2102 Ruska 2450 Force Gages – Tension & Compression 2 ozf to 1000 lbf (500 to 2000) lbf 1 gf to 20 kgf 0.043 lbf 0.52 % 0.099 gf Class F weights CDI-2000-011-0H Class 1 weights Load Cells – Tension & Compression (0 to 1000) lbf (500 to 25 000) lbf 0.060 lbf 0.17 lbf Class F weights Load cell & force stand Mass (1 to 5) mg (10 to 200) mg (>200 to 500) mg 1 g 2 g 3 g 4 g 5 g 10 g 20 g 50 g 100 g 200 g (>200 to 500) g 1kg 2 kg, 3 kg (>3 to 5) kg 20 kg 2.4 µg 2.7 µg 3.6 µg 2.6 µg 3.9 µg 4.0 µg 11 µg 13 µg 18 µg 18 µg 20 µg 31 µg 52 µg 0.17 mg 0.26 mg 0.78 mg 6.7 mg 15 mg Class 1 weights & Mettler AX26 balance Class 1 weights & Mettler AT201 balance Class 1 weights & V oland Jupiter 3000 Class 1 weights & Sartorius LC5101S Class 1 weight & Sartorius 3808 MP8-1
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 15 of 17 Parameter/Equipment Range CMC2, 5 (±) Comments Mass - Avoirdupois 0.125 lb 0.25 lb 0.5 lb 1 lb 2 lb 5 lb 10 lb 20 lb 25 lb 50 lb 27 µg 52 µg 0.59 mg 0.60 mg 0.63 mg 1.3 mg 6.7 mg 14 mg 14 mg 15 mg Class 1 weights & Mettler AT201 balance Class 1 weights & Sartorius LC5101S Class 1 weights & Sartorius 3808 MP8-1 Cable Tension Up to 2000 lbf 0.52 % CDI torque system with transducers &/or Class F weights VI. Thermodynamics Parameter/Equipment Range CMC2, 9 (±) Comments Temperature – Measuring Equipment -196 °C Nominal (-80 to 0) °C 0 °C (0 to 50) °C (50 to 200) °C (200 to 420) °C 0.036 °C 0.049 °C 0.034 0.034 °C 0.038 °C 0.068 °C LN2 w/ Hart 1590 & 5614 PRT Kaye CTR-80 bath w/ Hart 1590 Superthermometer & 5614 PRT Drywell 9101 ice point w/ Hart 1590 Superthermometer & 5614 PRT Fluke 7341 with Hart 1590 & 5614 PRT Fluke 6331 w/ Hart 1590 Superthermometer & 5614 PRT Drywell Hart 9122 w/ Hart 1590 Superthermometer & 5614 PRT Temperature3 – Measure (-196 to -38) °C (-38 to 0) °C 0 °C (0 to 232) °C (232 to 420) °C 0.033 °C 0.033 °C 0.032 °C 0.034 °C 0.036 °C Hart 1590 & 5614 PRT
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 16 of 17 Parameter/Equipment Range CMC2, 9 (±) Comments Temperature3 – Measure Uniformity of Ovens, Furnaces, Freezers, Refrigerators, Environmental Chambers (-30 to 140) °C (140 to 200) °C (200 to 400) °C (-30 to 140) °C (140 to 200) °C (200 to 400) °C 1.9 °C 2.5 °C 2.6 °C 1.4 °C 2.2 °C 2.4 °C Graphtec GL220 w/: Type K T/C Graphtec GL220 w/: Type T T/C Infrared Temperature3 – Measuring Equipment (-20 to +20) °C (400 to 1000) °C (20 to 500) °C 1.6 °C (0.8 + 0.0046T) °C (0.65 + 0.0012T) °C Mikron M340 Omega BB-4A w/ Fluke 52 where T is temperature in °C Fluke 9132 w/ Fluke 5614 PRT & 1590 Superthermometer Where: λ = (8 to 14 µm) ε = 0.95 ± 0.02 Relative Humidity3 – Generate & Measure (10 to 96) % RH 1.1 % RH Edgetech RH CAL w/ Vaisala MI70 VII. Time & Frequency Parameter/Range Frequency CMC 2, 9 (±) Comments Frequency – Measuring Equipment, Fixed Points (5, 10) MHz 3.2 x 10-12 Hz/Hz Fluke 910 GPS controlled frequency reference Timometer 32 768 Hz (nominal) 0.0093 s/day Fluke 910 w/ 33250A function generator Digital Stopwatches & Timers Quartz Crystal 32 768 Hz (nominal) 0.038 s/day Timometer ___________________________________________ 1 This laboratory offers commercial and field calibration service.
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2011.01) 11/05/2025 Page 17 of 17 2 Calibration and Measurement Capability (CMC) uncertainty is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; R is the numerical value of the resolution of the device in microinches; D is the diameter of the device in inches. 5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 6 Adjustable thread rings are set to applicable specifications using calibrated master set plug gages. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 Resolution of UUT not included in the calculation of CMC value. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 10 This scope meets A2LA’s P112 Flexible Scope Policy.
18ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

9553 Vassar Avenue, Chatsworth, CA, 91311, US

34.25725, -118.60170

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.