What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 85 standard numbers and the 56 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC16
IEC 60065
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60355-2-75
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60598-1Luminaires - Part 1: General requirements and tests
IEC 60598-2-1
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60825-1
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61347-1
IEC 61558-1
IEC 62301
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirementsExclusion
Limits written next to it
EN 62368-1:2014 + A11:2017 (Excluding cl.10.5)
EN 62368-1:2020 (Excluding cl.10.5)
IEC 62368-1:2014 (Excluding cl.10.5)
IEC 62368-1:2018 (Excluding cl.10.5)
IEC 62947
IEC 60335 series15
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
IEC 60335-2-15
IEC 60335-2-23
IEC 60335-2-24
IEC 60335-2-25
IEC 60335-2-27
IEC 60335-2-28
IEC 60335-2-49
IEC 60335-2-55
IEC 60335-2-75
IEC 60335-2-80
IEC 60335-2-84
IEC 60335-2-89
IEC 60335-2-98
IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.4identical to it
IEC 61000-6-8+1 national
National versions in the same scope
AS/NZS 61000.6.8probably the same standard; matched by number only
CISPR9
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers+1 national
National versions in the same scope
AS/NZS CISPR 12national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 24identical to it
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61326 series6
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
ISO 11452 series6
ISO 11452-1Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 1: General principles and terminology
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-3Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: Transverse electromagnetic (TEM) cell
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ETSI5
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
EN4
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
EN 50563
EN 50564
ISO4
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic dischargeExclusion
Limits written next to it
ISO 10605 (2008) (except Annex F)
ISO 13766-1Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 1: General EMC requirements under typical electromagnetic environmental conditions
ISO 13766-2Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 2: Additional EMC requirements for functional safety
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
IEC 60335-2-49:2002 + A1:2008; EN 60335-2-49:2003 + A1:2008 + A11:2012; IEC 60335-2-55:2002 + A1:2008; EN 60335-2-55:2003 + A1:2008; IEC 60335-2-75:2002 + A1:2004 + A2:2008; IEC 60355-2-75:2012 + A1:2015 + A2:2018; EN 60335-2-75:2004 + A1:2005 + A11:2006 + A2:2008 + A12:2010; IEC 60335-2-80:2002 + A1:2004 + A2:2008; IEC 60335-2-80:2015; EN 60335-2-80:2003 + A1:2004 + A2:2009; IEC 60335-2-84:2002 + A1:2008 + A2:2013; IEC 60335-2-84:2019; EN 60335-2-84:2003 + A1:2008 + A2:2019; EN IEC 60335-2-84:2021 + A11:2021; JIS C 9335-2-84:2019; IEC 60335-2-89:2010 + A1:2012 + A2:2015; EN 60335-2-89:2010 + A2:2016; IEC 60335-2-98:2002 + A1:2004 + A2:2008; EN 60335-2-98:2003 + A1:2005 + A2:2008; IEC 60065:1998; IEC 60065:2001 + A1:2005 + A2:2010; IEC 60065:2014; EN 60065:1998; EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011; UL 60065:2003; CAN/CSA C22.2 No.60065-03; JIS C6065:2013; IEC 60529; 1989 + A1:1999 + A2:2013; JIS C 0920:2003
IEC/EN 60335-1, -2-29 (2016), Amd.No.1(2019); IEC/EN 60335-1, -2-29 (2016); IEC/EN 60335-1, -2-35 (2012), Amd.No.1(2016); IEC/EN 60335-1, -2-54 (2008), Amd.No.1(2015), Amd.No.2(2019); IEC/EN 60335-1, -2-59 (2002), Amd.No.1(2006), Amd.No.2(2009); IEC/EN 60335-1, -2-65 (2002), Amd.No.1(2008), Amd.No.2(2015); IEC/EN 60335-1, -2-75 (2012), Amd.No.1(2015); IEC 60335-1, -2-84(2002), Amd.No.1(2008), Amd.No.2(2013); EN IEC 60335-1, 2-84(2021), Amd.No.11(2021); IEC/EN 60335-1, -2-89(2019); IEC/EN 60065 (2014) Corrigendum1/2; IEC/EN 61347-1 (2015), Amd.No.1(2017); IEC/EN 61347-1 (2007), Amd.No.1(2010), Amd.No.2(2012); IEC/EN 61347-1, -2-13(2014); IEC/EN 61558-1(2017); IEC/EN 61558-1 (2005), Amd.No.1(2009); IEC/EN 60950-1 (2005), Amd.No.1(2009), Amd.No.2(2013); IEC 62368-1(2014); IEC 62368-1(2018); IEC 60598-1(2014); IEC 60598-2-1(1979), Amd.No.1(1987); CISPR11 (2009:5th), Amd.No.1(2010); CISPR 14-1 (2005:5th), Amd.No.1(2009); CISPR 15(2013:8th); CISPR 32(2015:2nd)
IEC 60825-1:2014; EN 60825-1:2014; JIS C 6802:2014; JIS C 6802:2018; IEC 62947:2022; JIS A 4422:2024; IEC 60204-1:2016 +A1:2021; EN 60204-1:2018 +A1:2025; JIS B 9960-1:2019 +A1:2023; Department of Energy 10 CFR Part 430; CALIFORNIA ENERGY COMMISSION APPLIANCE EFFICIENCY REGULATIONS TITLE 20, SECTIONS 1601 THROUGH 1609; Commission Regulation (EU) 2019/1782; DIRECTIVE 2009/125/EC; EN 50563:2011 +A1:2013; AS/NZS 4665.1:2005/Amdt 1/2009-02-27; AS/NZS 4665.2/Amdt 1/2009-02-27
IEC 60950-1:2001; IEC 60950-1:2005 + A1:2009 + A2:2013; EN 60950-1:2001 + A11; EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+ A2:2013; UL 60950-1:2003; UL 60950-1:2007; UL 60950-1:2014; CAN/CSA C22.2 No.60950-1-03; CAN/CSA C22.2 No.60950-1-07 + A1:2011 + A2:2014; JIS C 6950-1:2012 + A1:2014; IEC 62368-1:2014; IEC 62368-1:2018; EN 62368-1:2014 + A11:2017; EN 62368-1:2020; IEC 60601-1:2005 + A1:2012 + A2:2020; EN 60601-1:2006 + A11:2011 + A1:2013 + A12:2014; CAN/CSA-C22.2 No. 60601-1-08; ANSI/AAMI ES60601 + A1:2005; JIS T 0601-1:2012 + A1:2014; JIS T 0601-1:2017; IEC 61010-1:2010 + A1:2016; EN 61010-1:2010 + A1:2019; UL 61010-1:2012; CAN/CSA-C22.2 No. 61010-1:2012; JIS C1010-1:2014; JIS C1010-1:2019; IEC 60335-1:2001 + A1:2004 + A2:2006; IEC 60335-1:2010 + A1 :2013+ A2:2016; IEC 60335-1:2020; EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011; EN 60335-1:2012 + A11:2014 + A13:2017 + A14:2019 + A1:2019 + A2:2019; UL 60335-1:2004; CAN/CSA E60335-1/4E:03; JIS C 9335-1:2003; JIS C 9335-1:2014; JIS C 9335-1:2023
EN 61326-2-3; EN 61326-2-3:2013; EN IEC 61326-2-3:2021; IEC 61326-2-3; IEC 61326-2-3:2012; IEC 61326-2-3:2020; JIS C 61326-2-3:2019; SANS 61326-2-3:2009; EN 61326-2-4; EN 61326-2-4:2013; EN IEC 61326-2-4:2021; IEC 61326-2-4; IEC 61326-2-4:2012; IEC 61326-2-4:2020; SANS 61326-2-4:2009; EN 61326-2-5; EN 61326-2-5:2013; EN IEC 61326-2-5:2021; IEC 61326-2-5; IEC 61326-2-5:2012; IEC 61326-2-5:2020; SANS 61326-2-5:2009; EN 60601-1-2; EN 60601-1-2:2015; EN 60601-1-2:2015+A1:2021; IEC 60601-1-2; IEC 60601-1-2:2014; IEC 60601-1-2:2014+A1:2020; JIS T 0601-1-2:2018; JIS T 0601-1-2:2023; EN 50130-4:2011; EN 50130-4:2011 + A1:2014; EN 301 489-1; EN 301 489-3; EN 301 489-17
EN 61000-6-3; EN 61000-6-3:2007 + A1:2011; EN IEC 61000-6-3:2021; IEC 61000-6-3; IEC 61000-6-3:2020; IEC 61000-6-8:2020; AS/NZS 61000.6.3; SANS 61000-6-3:2011; EN 61000-6-4; EN 61000-6-4:2007 + A1:2011; EN IEC 61000-6-4:2019; IEC 61000-6-4; IEC 61000-6-4:2018; AS/NZS 61000.6.4; SANS 61000-6-4:2011; EN 61326-1; EN 61326-1:2013; EN IEC 61326-1:2021; IEC 61326-1; IEC 61326-1:2012; IEC 61326-1:2020; JIS C 61326-1:2017; JIS C 61326-1:2022; SANS 61326-1:2007; EN 60601-1-2; EN 60601-1-2:2015; EN 60601-1-2:2015+A1:2021; IEC 60601-1-2; IEC 60601-1-2:2014; IEC 60601-1-2:2014+A1:2020; JIS T 0601-1-2:2018; JIS T 0601-1-2:2023; EN 55014-1; EN 55014-1:2017; EN IEC 55014-1:2021; CISPR 14-1; CISPR 14-1:2016; CISPR 14-1:2020; AS/NZS CISPR14.1:2021; J55014-1 (H27); SANS 214-1:2020
COMMISSION REGULATION (EC) No 1275/2008; COMMISSION REGULATION (EU) No801/2013; COMMISSION REGULATION (EU) 2023/826; DIRECTIVE 2009/125/EC; IEC 62301 Ed 1.0; IEC 62301 Ed 2.0; EN 50564:2011
JIS C 9335-1; JIS C 6065; JIS C 8147-1; JIS C 61558-1; JIS C 6950-1; JIS C 62368-1; JIS C 8105-1; JIS C 8105-2-1; IEC/EN 60335-1
IEC 60335-2-9:2002 + A1:2004 + A2:2006; IEC 60335-2-9:2008 + A1:2012 + A2:2016; EN 60335-2-9:2003 + A1:2004 + A2:2006 + A12:2007 +A13:2010; EN 60335-2-9:2016; IEC 60335-2-15:2002 + A1:2005 + A2:2008; IEC 60335-2-15:2012 + A1:2016 + A2:2018; EN 60335-2-15:2002 + A1:2005 + A2:2008 + A11:2012; EN 60335-2-15:2016 + A11:2018; IEC 60335-2-23:2003 + A1:2008 + A2:2012; IEC 60335-2-23:2016; EN 60335-2-23:2003 + A1:2008 + A11:2010 + A2:2015; EN 60335-2-23:2016; IEC 60335-2-24:2002 + A1:2005 + A2:2007; IEC 60335-2-24:2010 + A1:2012; EN 60335-2-24:2003 + A11:2004 + A1:2005 + A2:2007 + A12:2009; EN 60335-2-24:2010; IEC 60335-2-25:2002 + A1:2005 + A2:2006; EN 60335-2-25:2002 + A1:2005 + A2:2006 + A11:2010; IEC 60335-2-27:2002 + A1:2004 + A2:2007; EN 60335-2-27:2003 + A1:2008 + A2:2008; JIS C 9335-2-27:2005; IEC 60335-2-28:2002 + A1:2008; EN 60335-2-28:2003 + A1:20
EN 61000-4-6; EN 61000-4-6:2014; EN 61000-4-6:2009; EN 61000-4-6:2007; IEC 61000-4-6; IEC 61000-4-6:2023; IEC 61000-4-6:2013; IEC 61000-4-6:2008; IEC 61000-4-6:2003 + A1:2004 + A2:2006; JIS C 61000-4-6:2006; JIS C 61000-4-6:2017; SANS 61000-4-6:2017; EN 61000-4-8; EN 61000-4-8:2010; IEC 61000-4-8; IEC 61000-4-8:2009; JIS C 61000-4-8:2016; SANS 61000-4-8:2009; EN 61000-4-11; EN 61000-4-11:2004; EN 61000-4-11:2004 + A1:2017; EN IEC 61000-4-11:2020; IEC 61000-4-11; IEC 61000-4-11:2004; IEC 61000-4-11:2004 + A1:2017; IEC 61000-4-11:2020; JIS C 61000-4-11:2008; JIS C 61000-4-11:2021; SANS 61000-4-11:2005; IEC 61000-4-39; IEC 61000-4-39:2017; EN 61000-4-39; EN 61000-4-39:2017; EN 61000-3-2; EN 61000-3-2:2014; EN IEC 61000-3-2: 2019; EN IEC 61000-3-2: 2019+A1:2021; EN 61000-3-2:2006 + A1:2009 + A2:2009; IEC 61000-3-2; IEC 61000-3-2:2014; IEC 61000-3-2:2018; IEC 61000-3-2:2018+A1:2020; IEC 61000-3-2:2005 + A1:2008 + A2:2009; JIS C 61000-3-2:2011; JIS C 61000-3-2:2019; SANS 61000-3-2:2009
EN 61000-3-3; EN 61000-3-3:2013; EN 61000-3-3:2008; EN 61000-3-3:2013 + A1:2019; EN IEC 61000-3-3:2013 + A1:2019+A2:2021; IEC 61000-3-3; IEC 61000-3-3:2008; IEC 61000-3-3:2013; IEC 61000-3-3:2013 + A1:2017; IEC 61000-3-3:2013 + A1:2017 + A2:2021; SANS 61000-3-3:2009; EN 55024; EN 55024:2010+A1:2015; EN 55035:2017; EN 55035:2017+A11:2020; CISPR 24; CISPR 24:2010+A1:2015; CISPR 35:2016; AS/NZS CISPR 24; AS/NZS CISPR 24:2013+A1:2017; SANS 2335:2018; EN 61000-6-3; EN 61000-6-3:2007 + A1:2011; EN IEC 61000-6-3:2021; IEC 61000-6-3; IEC 61000-6-3:2020; IEC 61000-6-8:2020; AS/NZS 61000.6.3:2021; SANS 61000-6-3:2011; EN 61000-6-4; EN 61000-6-4:2007 + A1:2011; EN IEC 61000-6-4:2019; IEC 61000-6-4; IEC 61000-6-4:2018; AS/NZS 61000.6.4:2012; AS 61000.6.4:2020; SANS 61000-6-4:2011; IEC 61000-6-8; IEC 61000-6-8:2020; EN 61000-6-8; EN IEC 61000-6-8:2020; AS/NZS 61000.6.8; AS/NZS 61000.6.8:2021
EN 61000-4-2; EN 61000-4-2:1995 + A1:1998 + A2:2001; EN 61000-4-2:2009; IEC 61000-4-2; IEC 61000-4-2:1995 + A1:1998 + A2:2000; IEC 61000-4-2:2008; JIS C 61000-4-2:2012; SANS 61000-4-2:2009; EN 61000-4-3; EN IEC 61000-4-3:2020; EN 61000-4-3:2006 + A1:2008 + A2:2010; EN 61000-4-3:2006 + A1:2008; IEC 61000-4-3; IEC 61000-4-3:2020; IEC 61000-4-3:2006 + A1:2007 + A2:2010; IEC 61000-4-3:2006 + A1:2007; JIS C 61000-4-3:2012; JIS C 61000-4-3:2022; SANS 61000-4-3:2008; EN 61000-4-4; EN 61000-4-4:2012; EN 61000-4-4:2004 + A1:2010; EN 61000-4-4:2004; IEC 61000-4-4; IEC 61000-4-4:2004 + A1:2010; IEC 61000-4-4:2004; JIS C 61000-4-4:2007; JIS C 61000-4-4:2015; SANS 61000-4-4:2011; EN 61000-4-5; EN 61000-4-5:2006; EN 61000-4-5:2014; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-5:2014; IEC 61000-4-5:2014 + A1:2017; JIS C 61000-4-5:2009; JIS C 61000-4-5:2018; SANS 61000-4-5:2006
IEC 61000-4-2; ISO 10605; IEC 61000-4-4; IEC 61000-4-5: 2014/2017
ANSI C63.5 1998; SAE ARP958 Rev. D; SAE ARP958 Rev. E; ANSI C63.5 2017; CISPR 16-1-6:2014/AMD1:2017; IEC 61000-4-11; IEC 61000-4-6 (2008, 2013)
EN 61000-6-1; EN 61000-6-1:2007; EN IEC 61000-6-1:2019; IEC 61000-6-1; IEC 61000-6-1:2016; AS/NZS 61000.6.1:2006; JIS C 61000-6-1:2019; SANS 61000-6-1:2005; EN 61000-6-2; EN 61000-6-2:2005; EN IEC 61000-6-2:2019; IEC 61000-6-2; IEC 61000-6-2:2016; AS/NZS 61000.6.2:2022; JIS C 61000-6-2:2019; SANS 61000-6-2:2005; EN 61326-1; EN 61326-1:2013; EN IEC 61326-1:2021; IEC 61326-1; IEC 61326-1:2012; IEC 61326-1:2020; JIS C 61326-1:2017; JIS C 61326-1:2022; SANS 61326-1:2007; EN 61326-2-1; EN 61326-2-1:2013; EN IEC 61326-2-1:2021; IEC 61326-2-1; IEC 61326-2-1:2012; IEC 61326-2-1:2020; JIS C 61326-2-1:2017; JIS C 61326-2-1:2022; SANS 61326-2-1:2009; EN 61326-2-2; EN 61326-2-2:2013; EN IEC 61326-2-2:2021; IEC 61326-2-2; IEC 61326-2-2:2012; IEC 61326-2-2:2020; JIS C 61326-2-2:2017; SANS 61326-2-2:2009
EN 55011; EN 55011:2009 + A2:2010; EN 55011:2016; EN 55011:2016+A1:2017; EN 55011:2016+A11:2020; EN 55011:2016+A2:2021; CISPR 11; CISPR 11:2009 + A1:2010; CISPR 11:2015; CISPR 11:2015+A1:2016+A2:2019; AS CISPR 11:2017; AS CISPR 11:2017+A1:2020; ICES-001 Issue 5; CAN/30TCSA30T-30T; CEI/IEC CISPR30T38T11-04; CSA CISPR 11:19; SANS 211:201; EN 55012; EN 55012:2007 + A1:2009; CISPR 12; CISPR 12:2007 + A1:2009; ICES-002 Issue 7; CAN/CSA-CISPR12-10; AS/NZS CISPR12; EN 55014-1; EN 55014-1:2017+A11:2020; EN IEC 55014-1:2021; CISPR 14-1; CISPR 14-1:2016; CISPR 14-1:2020; J55014-1 (H27); AS/NZS CISPR 14.1:2021; SANS 214-1:2020; EN 55014-2; EN 55014-2:1997 + A1:2001 + A2:2008; EN 55014-2:2015; EN IEC 55014-2:2021; CISPR 14-2; CISPR 14-2:2015; CISPR 14-2:2020; AS/NZS CISPR 14.2:2021; SANS 214-2:2009
EN 55011; EN 55011:2009 + A2:2010; EN 55011:2016; EN 55011:2016+A1:2017; EN 55011:2016+A11:2020; EN 55011:2016+A2:2021; CISPR 11; CISPR 11:2009 + A1:2010; CISPR 11:2015; CISPR 11:2015+A1:2016+A2:2019; AS CISPR 11:2017; AS CISPR 11:2017+A1:2020; ICES-001 Issue 5; CAN/30TCSA30T-30TCEI/IEC CISPR30T38T11-04; CSA CISPR 11:19; SANS 211:2010; EN 55012; EN 55012:2007 + A1:2009; CISPR 12; CISPR 12:2007 + A1:2009; ICES-002 Issue 6:2013; ICES-002 Issue 7; CAN/CSA-CISPR 12-10; AS/NZS CISPR 12; EN 55022:2010; EN 55032; EN 55032:2015; EN 55032:2015+A1:2020; EN 55032:2015+A11:2020; CISPR 22:2008; CISPR 32; CISPR 32:2015; CISPR 32:2015+A1:2019; AS/NZS CISPR 32:2015; AS/NZS CISPR 32:2015+A1:2020; ICES-003 Issue 7; CAN/CSA-CEI/IEC CISPR 22:2010; FCC 47 CFR Part 15, Subpart B (using ANSI C63.4-2014, up to 26.5 GHz); ANSI C63.4-20143; J55032 (H29); SANS 233:2017
FCC 47 CFR Part 15B (using ANSI C63.4-2014); FCC 47 CFR Part 15C (using ANSI C63.10-2020); ANSI C63.4-2014; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024; ICES-003 Issue 7; RSS-Gen; RSS-210; RSS-247; EN 300 328; EN 300 330; FCC 47 CFR Part 18 (using MP-5-1986); EN 55014-1; EN 55014-1:2017+A11:2020; EN IEC 55014-1:2021; CISPR 14-1; CISPR 14-1:2016; CISPR 14-1:2020; AS/NZS CISPR 14.1:2021; J55014-1 (H27); SANS 214-1:2020; ANSI C63.4-2014; FCC MP-5 (February 1986); ANSI C63.10-2020
EN 55022:2010; EN 55032; EN 55032:2015; EN 55032:2015+A1:2020; EN 55032:2015+A11:2020; CISPR 22:2008; CISPR 32; CISPR 32:2015; CISPR 32:2015+A1:2019; AS/NZS CISPR 32:2015; AS/NZS CISPR 32:2015+A1:2020; ICES-003 Issue 7; CAN/CSA-CEI/IEC CISPR 22:2010; CFR 47 FCC Part 15B (using ANSI C63.4-2014); CFR 47 FCC Part 18 (using MP-5-1986); ANSI C63.4-2014; J55032 (H29); VCCI-CISPR 32:2016; SANS 2332:2017
ECE Reg.10 (2014) Rev. 5 + A1:2016; ECE Reg.10 (2019) Rev. 6 + A1:2020; ECE Reg.10 (2019) Rev. 6 + A1:2020+ A2:2022; ECE Reg.10 (2019) Rev. 6 + A1:2020+ A2:2022+A3:2024+A4:2025; EN 50498; EN 50498 (2010); ISO 13766-1; ISO 13766-1 (2018); ISO 13766-2; ISO 13766-2 (2018); CISPR 25; CISPR 25 (2021) Section 6.3, H.3; CISPR 25 (2016) Section 6.3, I.2; CISPR 25 (2008) Section 6.2; CISPR 25 (2002) Section 6.2; CISPR 25 (2021) Section 6.3, H.4; CISPR 25 (2016) Section 6.4, I.3; CISPR 25 (2008) Section 6.3; CISPR 25 (2002) Section 6.3; CISPR 25 (2021) Section 6.3, H.5; CISPR 25 (2016) Section 6.5, I.4; CISPR 25 (2008) Section 6.4; CISPR 25 (2002) Section 6.4; ISO 7637-2; ISO 7637-2 (2011); ISO 7637-1 (2002) + A1 (2008); ISO 7637-2 (2004) + A1 (2008) Section 4.3; ISO 7637-2 (2004) + A1 (2008) Sections 4.4, 5.6.1 to 5.6.5
ISO 7637–3; ISO 7637–3 (2016); ISO 7637-3 (2007) Sections 3.4.2, 3.4.3, 3.4.4; ISO 16750-2; ISO 16750-2 (2023); ISO 16750-2 (2012); ISO 16750-2 (2006); ISO 10605; ISO 10605 (2023); ISO 10605 (2008) + A1 (2014); ISO 10605 (2008) (except Annex F); ISO 10605 (2001); ISO 11452-9; ISO 11452-9 (2021); ISO 11452-9 (2012); ISO 11452-1; ISO 11452-1 (2015); ISO 11452-1 (2005); ISO 11452-2; ISO 11452-2 (2019); ISO 11452-2 (2004); ISO 11452-3; ISO 11452-3 (2016); ISO 11452-3 (2001); ISO 11452-4; ISO 11452-4 (2020); ISO 11452-4 (2011); ISO 11452-4 (2005); ISO 11452-8; ISO 11452-8 (2015) (Radiating Loop); ISO 11452-8 (2007) (Radiating Loop)
ANSI C63.4a:2017; ANSI C63.4:2014; A2LA document R222 - Specific Requirements - EPA ENERGY STAR Accreditation Program
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
44 lines
ISO/IEC 17025
Active2900.01
The scope document we hold says it is valid until 2027-09-30.
ISO/IEC 17025
Active2900.02
The scope document we hold says it is valid until 2027-09-30.
ISO/IEC 17065
Active2900.03
The scope document we hold says it is valid until 2027-03-31.
Location
718-1, Katsurase-cho, Matsusaka-shi, Mie, 515-1104, Japan, Matsusaka-shi, Mie, JP
34.57794, 136.52760
Open in MapsLabs with overlapping accredited scope in Japan
- LAB SupportAzumino-shi, Nagano-ken · ~229 kmA2LAShares 2 accredited test methodsANSI C63.4:2014EN 55032
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~276 kmA2LAShares 2 accredited test methodsCISPR 25IEC 61000-4-11
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~342 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61000-4-2
- JEL LimitedAbiko · ~349 kmDAKKSShares 2 accredited test methodsEN 55032EN 61000-4-2
- JEL LimitedChiba · ~357 kmA2LAShares 2 accredited test methodsCISPR 25IEC 61000-4-2
Accreditation data refreshed from the A2LA register on .