Registers refreshed 2026-11-08.See refresh dates
China

Shenzhen Bangce Testing Technology Co. ,

101, building 10, Yunli Intelligent Park, Shutian Pu community, Matian Street, Guangming District, Shenzhen, Shenzhen, People's Republic of China, Shenzhen, China

Visit website
A2LA 7121.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
59
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 59 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI33
ETSI EN 300 113
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-1
ETSI EN 300 422-2
ETSI EN 300 422-3
ETSI EN 300 422-4
Show all 33
ETSI EN 300 440
ETSI EN 301 357
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 303 345-1
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 446-1
ETSI EN 303 446-2
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national

National versions in the same scope

AS/NZS 61000.4.2probably the same standard; matched by number only

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national

National versions in the same scope

AS/NZS 61000.4.3probably the same standard; matched by number only

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national

National versions in the same scope

AS/NZS 61000.4.4probably the same standard; matched by number only

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national

National versions in the same scope

AS/NZS 61000.4.5probably the same standard; matched by number only

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national

National versions in the same scope

AS/NZS 61000.4.6probably the same standard; matched by number only

Certificate says EN 61000-4-6. Probably the same standard; not checked against the EN document.

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national

National versions in the same scope

AS/NZS 61000.4-8probably the same standard; matched by number only

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national

National versions in the same scope

AS/NZS 61000.4.11probably the same standard; matched by number only

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national

National versions in the same scope

AS/NZS 61000.6.3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

AS/NZS 61000.6.4identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national

National versions in the same scope

AS CISPR 14.1national version with changes

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national

National versions in the same scope

AS/NZS CISPR 14-2probably the same standard; matched by number only

Certificate says EN 55014-2. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national

National versions in the same scope

AS CISPR 15national version with changes

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

IEC4
IEC 61547Equipment for general lighting purposes - EMC immunity requirements

Certificate says EN 61547. Probably the same standard; not checked against the EN document.

IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50364
FCC PART 15Radio Frequency Devices

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

7121.01

The scope document we hold says it is valid until 2027-09-30.

View scope

Accredited scope, certificate 7121.01

LineMethodMatrixRange
1CFR 47, FCC Part 15B; ANSI C63.4:2014; CFR 47, FCC Part 18; FCC MP-5:1986; ICES-001; ICES-003; ICES-005; RSS-GEN; AS CISPR 11; BS EN 55011; EN 55011; CISPR 11; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J55014-1; BS EN IEC 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; J55015; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; J55011; VCCI V-3; VCCI V-32-1; BS EN IEC 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; AS/NZS 61000.4.2; BS EN IEC 61000-4-3; EN IEC 61000-4-3; IEC 61000-4-3; AS/NZS 61000.4.3; BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4; AS/NZS 61000.4.4; BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5; AS/NZS 61000.4.5--
2BS EN 61000-4-6; IEC 61000-4-6; EN 61000-4-6; AS/NZS 61000.4.6; BS EN 61000-4-8; EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000.4-8; BS EN 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; AS/NZS 61000.4.11; BS EN 55014-2; EN 55014-2; CISPR 14-2; AS/NZS CISPR 14-2; EN 62040-2; BS EN 61547; IEC 61547; EN 61547; BS EN 55035; EN 55035; CISPR 35; BS EN 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; BS EN IEC 61000-6-2; IEC 61000-6-2; EN IEC 61000-6-2; BS EN 61000-6-3; IEC 61000-6-3; EN 61000-6-3; AS/NZS 61000.6.3; BS EN IEC 61000-6-4; IEC 61000-6-4; EN IEC 61000-6-4; AS/NZS 61000.6.4; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-9; EN 301 489-17; EN 301 489-19; EN 301 489-34; EN 301 489-50; EN 301 489-52; EN 303 446-1; EN 303 446-2; CFR 47, FCC Part 15C; ANSI C63.10-2013; CFR 47, FCC Part 15E; FCC KDB 905462 D02 (v02); ANSI C63.10:2020; RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-310; CFR 47, FCC Parts 22, 24, 25, 27, 30, 74, 90, 95, 96, 97, and 101; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; RSS-GEN; RSS-119; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; EN 300 328; EN 301 893; EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2--
3EN 300 220-4; EN 300 440; EN 300 330; EN 300 422-1; EN 300 422-2; EN 300 422-3; EN 300 422-4; EN 303 413; EN 301 357; EN 303 345-1; EN 300 113; EN 301 511; ETSI EN 301 908-1; EN 301 908-2; EN 301 908-13; EN 303 417; AS/NZS 4268; AS/NZS 4771; BS EN 62311; IEC 62311; EN 62311; EN IEC 62311; BS EN 62479; IEC 62479; EN 62479; AS/NZS 2772.2; BS EN 50364; EN 50364--
4ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015-to 40000 MHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHENZHEN BANGCE TESTING TECHNOLOGY CO., LTD. Shenzhen, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 19th day of August 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7121.01 Valid to September 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.