Registers refreshed 2026-11-08.See refresh dates
United States

G.T. MICHELLI CO., LLC - Goleta

275 Orange Avenue #A, 93117, Goleta, CA, United States

Visit website
A2LA 3601.14ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
21
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 21 scope lines.

A2LA certificate 3601.14 · 21 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 8 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Page 2 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2, 5 (±) Comments Feeler Gages3 Up to 0.01 in 35 µin P&W Supermic TM, gage blocks Gage Blocks Up to 0.11 in (0.11 to 1) in (1 to 4) in Up to 25 mm (25 to 50) mm (50 to 100) mm 4.5 µin (4 + 0.8L) µin (3 + 1.5L) µin 0.11 µm (0.1 + 0.02L) µm (0.1 + 0.01L) µm Gage block comparator, Grade 1 gage blocks Height Gages3 Up to 8 in (8 to 24) in (290 + 0.4L) µin (280 + 1.3L) µin Mu-checker, surface plate, gage blocks Height Master Up to 18 in (38 + 1.2 L) µin Mu-checker, surface plate, gage blocks Indicators3 (Drop & Test) Up to 4 in (4 to 10) in (24 + 19L) µin (250 + 9L) µin Micrometer head, gage blocks, Surface plate or P&W Supermic Inside Micrometers Up to 4 in (4 to 24) in 230 µin (69 + 3L) µin P&W Lab Master, gage blocks, riser block, sine plate, height master Outside Micrometers3 Up to 3 in (3 to 20) in 33 µin (52 + 1.8L) µin Gage blocks Micrometer Heads3 Up to 2 in 18 µin Mu-checker, gage blocks Mu Checkers3 Up to 150 µin 5.2 µin Gage blocks Optical Comparator3 Linear Measurement X-Axis & Y-Axis Angular Measurement Magnification Up to 6 in (6 to 12) in Up to 360 ° 10X, 20X, 31.25X, 100X 170 µin + 0.8L 140 µin + 6.1L 44 arcsec 0.011 in + 0.000 02L Microrule, gage blocks, glass scale Angle blocks Magnification checker
to 0.01 in
3

Extracted from the scope document; tables may not line up. View scope for the original.

Page 3 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2, 5 (±) Comments Plugs Cylindrical – Pin Gage Up to 6 in (2.5 + 4L) µin P&W LabMasterTM, gage blocks Protractors, Digital (0 to 90)° 0.058° Rotary table, level Protractors, Bevel Angle Blade Parallelism (0 to 35)° Up to 0.001 in 0.025° 34 µin Angle blocks, Mu- checker, surface plate Thread Plugs Gages Pitch Diameter Major Diameter Angle Up to 6 in Up to 6 in (0 to 60)° (130 + 0.2L) µin (10 + 1.7L) µin 1.5ʹ Gage blocks, thread wires, P&W SupermicTM, optical comparator Thread Ring Gauges – Adjustable Pitch Diameter Minor Diameter Up to 4 in Up to 6 in 79 µin (11 + 1.5L) µin Master setting plug gages, P&W SupermicTM Radius Gauge Up to 1 in 300 µin Optical comparator, radius screen Rings Gages Plain, Cylindrical Up to 1 in (1 to 11) in 5.6 µin (0.8 + 4.8L) µin P&W LabMasterTM, gage blocks Steel Rules Up to 72 in (130 + 37 L) µin Optical comparator Thread Wires (4 to 120) TPI 29 µin Plug gages, P&W LabMasterTM, gage blocks Tri-Micrometers3 (Intermics) Up to 4 in 250 µin Ring gages
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Page 4 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2 (±) Comments Vee Block Parallelism to Adjacent Side Parallelism to Opposite Side Side Squareness Surface Flatness & Parallelism Up to 0.001 in Up to 0.001 in Up to 0.001 in Up to 0.001 in 68 µin 36 µin 64 µin 34 µin Plug gauge, Mu checker, surface plate Angle block, Mu checker, surface plate Granite cube, Mu checker, surface plate Mu checker, surface plate II. Dimensional Testing7 Parameter Range CMC 2, 5 (±) Comments Dimensional Measurement7 – 1D Length Height Depth Flatness/Parallelism Go/No-Go Squareness Up to 13 in Up to 4 in Up to 4 in Up to 24 in Up to 1200 in Up to 18 in Up to 1 in Up to 0.001 in Up to 1 in Up to 11.31 inDL (2 + 4.2L) µin 78 µin (130 + 1L) µin (32 + 2.3L) µin (0.007 + 0.0002L) in (60 + 2.6L) µin 150 µin 36 µin (120 + 8L) µin 56 µin Universal length measuring machine Micrometer set Optical comparator (x-axis only) Gage blocks, Mu checker & surface plate Steel rule Height master, Mu checker & surface plate Drop indicator Mu checker & surface plate Pin gages Granite cube, Mu checker & surface
to 0.001 in
5

Extracted from the scope document; tables may not line up. View scope for the original.

Page 5 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2 (±) Comments Dimensional Measurement7 – 2D Angle Radius Up to 360° Up to 1 in 74ʺ 260 µin Optical comparator III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 4 (±) Comments DC Voltage3 – Generate Up to 329.9999 mV Up to 3.299 999 V Up to 32.999 99 V (30 to 329.9999) V (330 to 1020) V 13 µV/V + 0.7 µV 7 µV/V + 1.3 µV 8 µV/V + 13 µV 12 µV/V + 0.1 V 12 µV/V + 1 mV Fluke 5522A multiproduct calibrator DC Voltage3 – Measure Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V 100 V to 1 kV (1 to 10)kV 7.8 µV/V + 0.4 µV 6.8 µV/V + 0.35 µV 6.8 µV/V + 0.65 µV 9 µV/V + 40 µV 19 µV/V + 0.5 mV 0.056 % of rdg HP 3458A Opt 002 8.5-digit multimeter Vitrk 4700 DC Current3 – Generate Up to 329.999 µA Up to 3.299 99 mA Up to 32.9999 mA Up to 329.999 mA Up to 1.099 99 A (1.1 to 2.999 99) A Up to 10.9999 A (11 to 20.5) A 100 µA/A + 13 nA 67 µA/A + 33 nA 67 µA/A + 0.17 µA 67 µA/A + 1.7 µA 0.13 mA/A + 27 µA 0.25 mA/A + 27 µA 0.33 mA/A + 0.33 mA 0.67 mA/A + 0.5 mA Fluke 5522A multiproduct calibrator DC Current3 – Measure Up to 100 nA 100 nA to 1 µA (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 39 µA/A + 46 pA 30 µA/A + 46 pA 27 µA/A + 0.11 nA 28 µA/A + 0.86 nA 28 µA/A + 5.6 nA 28 µA/A + 56 nA 45 µA/A + 0.56 µA 0.13 mA/A + 10 µA HP 3458A Opt 002 8.5-digit multimeter
6

Extracted from the scope document; tables may not line up. View scope for the original.

Page 6 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage3 – Generate (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.53 mV/V + 4 µV 0.1 mV/V + 4 µV 0.13 mV/V + 4 µV 0.17 mV/V + 4 µV 2.3 mV/V + 8 µV 5.3 mV/V + 33 µV 0.2 mV/V + 5.3 µV 0.1 mV/V + 5.3 µV 0.11 µV/V + 5.3 µV 0.23 mV/V + 5.3 µV 0.53 mV/V + 21 µV 1.3 mV/V + 47 µV 0.2 mV/V + 33 µV 0.1 mV/V + 40 µV 0.13 mV/V + 40 µV 0.2 mV/V + 33 µV 0.43 mV/V + 83 µV 1.1 mV/V + 0.27 mV 0.2 mV/V + 0.43 mV 0.1 mV/V + 0.4 mV 0.16 mV/V + 0.4 mV 0.23 mV/V + 0.4 mV 0.6 mV/V + 1.1 mV 0.13 mV/V + 1.3 mV 0.13 mV/V + 4 mV 0.02 mV/V + 4 mV 0.2 mV/V + 4 mV 1.3 mV/V + 33 mV 0.2 mV/V + 6.7 mV 0.2 mV/V + 6.7 mV 0.2 mV/V + 6.7 mV Fluke 5522A multiproduct calibrator
7

Extracted from the scope document; tables may not line up. View scope for the original.

Page 7 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage3 – Measure Up to 10 mV (10 to 100 mV) 100 mV to 1 V (1 to 10) V (1 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 250) kHz (250 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 250) kHz (250 to 500) kHz 500 kHz to 1 MH (1 to 2) MHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 250) kHz (250 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 250) kHz (250 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz 4.1 µV/V + 34 µV 1.6 mV/V + 27 µV 0.77 mV/V + 27 µV 1.8 mV/V + 27 µV 1.6 mV/V + 27 µV 7.1 mV/V + 37 µV 40 mV/V + 72 µV 0.12 mV/V + 2.4 µV 0.12 mV/V + 2.4 µV 0.12 mV/V + 2.4 µV 4.1 mV/V + 20 µV 1.6 mV/V + 20 µV 0.68 mV/V + 10 µV 1.8 mV/V + 10 µV 1.6 mV/V + 40 µV 6.1 mV/V + 80 µV 20 mV/V + 0.5 mV 30 mV/V + 0.6 mV 50 mV/V + 2 mV 0.1 V/V + 5 mV 4.1 mV/V + 0.2 mV 1.6 mV/V + 0.2 mV 0.68 mV/V + 0.1 mV 1.8 mV/V + 0.1 mV 1.6 mV/V + 0.4 mV 6.1 mV/V + 0.8 mV 20 mV/V + 5 mV 30 mV/V + 6 mV 50 mV/V + 20 mV 0.1 V/V + 50 mV 4.1 mV/V + 2 mV 1.6 mV/V + 2 mV 0.68 mV/V + 1 mV 1.8 mV/V + 1 mV 1.6 mV/V + 4 mV 6.1 mV/V + 8 mV 20 mV/V + 50 mV 30 mV/V + 60 mV 50 mV/V + 0.2 V 0.1 V/V + 0.5 V HP 3458A Opt 002 8.5-digit multimeter
8

Extracted from the scope document; tables may not line up. View scope for the original.

Page 8 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage3 – Measure (cont) (10 to 100) V (100 to 1000) V (1000 to 10 000) V (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 250) kHz (250 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (50 to 60) Hz 4.1 mV/V + 20 mV 1.6 mV/V + 20 mV 0.68 mV/V + 10 mV 1.8 mV/V + 10 mV 1.6 mV/V + 40 mV 6.1 mV/V + 80 mV 20 mV/V + 0.5 V 30 mV/V + 0.6 V 50 mV/V + 2 V 4.3 mV/V + 0.3 V 1.8 mV/V + 0.3 V 0.88 mV/V + 0.2 V 2.2 mV/V + 0.2 V 1.6 mV/V + 0.4 V 6.1 mV/V + 2 V 0.16 % rdg HP 3458A Opt 002 8.5 digit multimeter Vitrek 4700 AC Current3 – Generate (29 to 329.99) µA (0.33 to 3.299 99) mA (3.3 to 32.9999) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.13 µA/A + 67 nA 0.1 µA/A + 67 nA 80 nA/A + 67 nA 0.2 µA/A + 0.1 µA 0.53 µA/A + 0.13 µA 1.1 µA/A + 0.27 µA 0.13 µA/A + 0.1 µA 80 nA/A + 0.1 µA 0.67 µA/A + 0.1 µA 0.13 µA/A + 0.13 µA 0.33 µA/A + 0.2 µA 70 nA/A + 0.4 µA 0.12 µA/A + 0.13 µA 60 nA/A + 0.13 µA 57 nA/A + 0.13 µA 53 nA/A + 0.13 µA 0.13 µA/A + 2 µA 0.27 µA/A + 2.7 µA Fluke 5522A multiproduct calibrator
9

Extracted from the scope document; tables may not line up. View scope for the original.

Page 9 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Current3 – Generate (cont) (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz 0.12 µA/A + 13 µA 60 nA/A + 13 µA 27 nA/A + 13 µA 67 nA/A + 33 µA 0.13 µA/A + 67 µA 0.27 µA/A + 0.13 mA 0.12 µA/A + 33 µA 33 nA/A + 67 µA 0.4 µA/A + 0.67 mA 1.7 µA/A + 3.3 mA 1.7 µA/A + 67 µA 1.7 µA/A + 37 µA 1.7 µA/A + 0.67 mA 1.7 µA/A + 3.3 mA 70 nA/A + 1.3 mA 67 nA/A + 1.3 mA 2 µA/A + 1.3 mA 80 nA/A + 3.3 mA 0.1 µA/A + 3.3 mA 2 µA/A + 3.3 mA Fluke 5522A multiproduct calibrator AC Current3 – Measure (5 to 100) µA 100 µA to 1 mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz 4.5 mA/A + 34 nA 1.6 mA/A + 30 nA 0.68 mA/A + 34 nA 0.68 mA/A + 35 nA 4.5 mA/A + 0.23 µA 1.7 mA/A + 0.23 µA 0.68 mA/A + 0.23 µA 0.38 mA/A + 0.22 µA 0.68 mA/A + 0.23 µA 4.5 mA/A + 0.45 mA 6.3 mA/A + 2 µA HP 3458A Opt 002 8.5-digit multimeter
10

Extracted from the scope document; tables may not line up. View scope for the original.

Page 10 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Current3 – Measure (cont) (1 to 10) mA (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 4.5 mA/A + 2.3 µA 1.7 mA/A + 2.3 µA 0.68 mA /A + 2.3 µA 0.38 mA /A + 2.1 µA 0.68 mA /A + 2.3 µA 4.5 mA/A + 4.5 µA 6.3 mA/A + 20 µA 4.5 mA/A + 23 µA 1.7 mA/A + 23 µA 0.69 mA/A + 23 µA 0.38 mA/A + 21 µA 0.69 mA/A + 20 µA 4.5 mA/A + 45 µA 6.2 mA/A + 0.17 mA 4.5 mA/A + 0.23 mA 1.8 mA/A + 0.23 mA 0.91 mA/A + 0.23 mA 1.1 mA/A + 0.25 mA 3.4 mA/A + 0.22 mA 11 mA/A + 0.45 mA HP 3458A Opt 002 8.5-digit multimeter Parameter/Equipment Range CMC 2, 4 (±) Comments Resistance3 – Generate Up to 10.9999 Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.999 99) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 27 µΩ/Ω + 6.7 mΩ 20 µΩ/Ω + 10 mΩ 19 uΩ/Ω + 10 mΩ 19 µΩ/Ω + 13 mΩ 19 µΩ/Ω + 13 mΩ 19 µΩ/Ω + 0.13 Ω 19 µΩ/Ω + 67 mΩ 19 µΩ/Ω + 0.67 Ω 19 µΩ/Ω + 0.67 Ω 21 µΩ/Ω + 6.7 Ω 21 µΩ/Ω + 6.7 Ω 40 µΩ/Ω + 0.1 kΩ 87 µΩ/Ω + 0.17 kΩ 0.17 mΩ/Ω + 1.7 Ω 0.33 mΩ/Ω + 2 Ω 2 mΩ/Ω + 17 kΩ 17 mΩ/Ω + 0.33 MΩ Fluke 5522A multiproduct calibrator
11

Extracted from the scope document; tables may not line up. View scope for the original.

Page 11 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2, 4 (±) Comments Resistance3 – Generate Fixed 0.1 Ω 2 mΩ 5 mΩ 10 mΩ 3.3 µΩ 0.5 µΩ 0.5 µΩ 1.2 µΩ Simpson current shunts Resistance3 – Measure Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 k Ω to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 M Ω to 1 GΩ 18 µΩ/Ω + 79 µΩ 17 µΩ/Ω + 0.58 mΩ 15 µΩ/Ω + 0.68 mΩ 15 µΩ/Ω + 2.1 mΩ 15 µΩ/Ω + 30 mΩ 20 µΩ/Ω + 2.4 Ω 59 µΩ/Ω + 0.13 kΩ 0.6 mΩ/Ω + 1.6 kΩ 5.6 mΩ/Ω + 54 kΩ HP 3458A Opt 002 8.5-digit multimeter Parameter/Range Frequency CMC 2, 4 (±) Comments Capacitance3 – Generate (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz DC to 50 Hz DC to 20 Hz DC to 6 Hz DC to 2 Hz DC to 0.6 Hz DC to 0.2 Hz 0.33 % of rdg + 6.7 pF 0.33 % of rdg + 6.7 pF 0.33 % of rdg + 6.7 pF 0.17 % of rdg + 6.7 pF 0.17 % of rdg + 67 pF 0.17 % of rdg + 67 pF 0.17 % of rdg + 0.2 nF 0.17 % of rdg + 1 nF 0.17 % of rdg + 2 nF 0.17 % of rdg + 6.7 nF 0.27 % of rdg + 20 nF 0.3 % of rdg + 67 nF 0.3 % of rdg + 0.2 µF 0.3 % of rdg + 0.7 µF 0.3 % of rdg + 2 µF 0.3 % of rdg + 6.7 µF 0.5 % of rdg + 20 µF 0.7 % of rdg + 67 µF Fluke 5522A multiproduct calibrator
12

Extracted from the scope document; tables may not line up. View scope for the original.

Page 12 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2 (±) Comments Oscilloscopes3 Amplitude – DC Signal Into 50 Ω Load Into 1 MΩ Load Amplitude – Square Wave Into 50 Ω Load Into 1M Ω Load Amplitude – Level Sine Wave 50 Ω, 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz Time Marker Into 50 Ω Load Pulse Rise Time Amplitude – Wave Generator Into 50 Ω Load Into 1M Ω Load 1 mVp-p to 6.6 Vp-p 1 mVp-p to 130 Vp-p 1m Vp-p to 6.6 Vp-p 10 Hz to 100 kHz 1m Vp-p to 130 Vp-p 10 Hz to 100 kHz 5 mV to 5.5 V 5 mV to 5.5 V 5 mV to 5.5 V 5 mV to 5.5 V 5 mV to 3.5 V 2 ns to 20 ms 50 ms to 5s < 350 ps 1 kHz to 10 MHz 1.8 mVp-p to 2.5 V p-p 10 Hz to 100 kHz 1.8 mVp-p to 55 V p-p 10 Hz to 100 kHz 0.25 % of rdg + 40 µV 0.05 % of rdg + 40 µV 0.28 % of rdg + 40 µV 0.11 % of rdg + 40 µV 2.01 % of rdg + 0.3 mV 4.14 % of rdg + 0.3 mV 4.36 % of rdg + 0.3 mV 6.22 % of rdg + 0.3 mV 7.13 % of rdg + 0.3 mV 0.00038 % of rdg 0.51 % of rdg 101 ps 3.01% of rdg + 0.1 mV 3.02 % of rdg + 0.1 mV Fluke 5522A/SC1100 multiproduct calibrator
13

Extracted from the scope document; tables may not line up. View scope for the original.

Page 13 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2 (±) Comments Electrical Simulation of Thermocouple Indicators3 – Generate/Measure Type B Type C Type E Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 15) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.44 °C 0.36 °C 0.32 °C 0.35 °C 0.30 °C 0.27 °C 0.31 °C 0.44 °C 0.70 °C 0.43 °C 0.20 °C 0.19 °C 0.20 °C 0.23 °C 0.26 °C 0.18 °C 0.17 °C 0.21 °C 0.24 °C 0.33 °C 0.20 °C 0.21 °C 0.25 °C 0.37 °C 0.40 °C 0.25 °C 0.22 °C 0.21 °C 0.27 °C 0.51 °C 0.37 °C 0.34 °C 0.38 °C 0.46 °C 0.36 °C 0.37 °C 0.44 °C 0.52 °C 0.24 °C 0.18 °C 0.20 °C Fluke 5522A multiproduct calibrator
14

Extracted from the scope document; tables may not line up. View scope for the original.

Page 14 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2 (±) Comments Electrical Simulation of RTD Indicators3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C 0.03 °C 0.03 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.15 °C 0.03 °C 0.03 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.17 °C 0.03 °C 0.03 °C 0.04 °C 0.05 °C 0.05 °C 0.06 °C 0.07 °C 0.15 °C 0.03 °C 0.03 °C 0.03 °C 0.03 °C 0.18 °C 0.09 °C 0.1 °C 0.11 °C 0.03 °C 0.03 °C 0.03 °C 0.04 °C 0.05 °C 0.05 °C 0.06 °C 0.07 °C 0.02 °C 0.02 °C 0.03 °C 0.04 °C 0.05 °C 0.05 °C Fluke 5522A multiproduct calibrator
15ASTM Class 1 weights; ASTM Class 4 weights; ASTM Class 6 weights; BP042-See scope document
16ASTM Class 1; ASTM Class 4; ASTM Class 5; ASTM Class 6-to 10000 lbf
17

Extracted from the scope document; tables may not line up. View scope for the original.

Page 17 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 Parameter/Equipment Range CMC 2,4 (±) Comments Pipettes (20 to 10 000) µL 0.04 % of rdg + 0.03 µL Precision balances, distilled water Pressure Gages, Pressure Transducers3 (-14.7 to 0) psig (-29.92 to 0) inHg Up to 30 psig (0 to 100) psig (0 to 500) psig (0 to 1000) psig (0 to 5000) psig (0 to 10 000) psig (60 to 110) kPa.a (17.7 to 32.4) inHg (0.000 01 to 0.5) inH2O 0.0051 psig 0.0084 inHg 0.004 psig 0.025 psig 0.12 psig 0.25 psig 1.3 psig 2.6 psig 0.056 kPa.a 0.017 inHg 0.000 73 inH2O Digital test gauges Torque Transducers Up to 27.6 lbf·in (27.6 to 150) lbf·in 150 lbf·in to 60 lbf·ft (60 to 2000) lbf·ft 0.007 % of rdg + 0.004 lbf·in 0.06 % of rdg + 0.0001 lbf·in 0.3 % of rdg + 0.009 lbf·ft 0.08 % of rdg + 0.0005 lbf·ft Torque wheels, torque arms, Class 6 weights Torque Tools3 (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft (60 to 600) lbf·ft (200 to 2000) lbf·ft 0.17 % of rdg + 0.11 lbf·in 0.41 % of rdg + 0.05 lbf-in 0.42 % of rdg + 0.02 lbf·in 0.39 % of rdg + 0.07 lbf·ft 0.3 % of rdg + 0.01 lbf·ft 0.3 % of rdg + 0.004 lbf·ft CDI torque machine
18

Extracted from the scope document; tables may not line up. View scope for the original.

Page 18 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 VI. Thermodynamics Parameter/Equipment Range CMC 2, 6 (±) Comments Humidity3 – (10 to 90) % RH (90 to 95) % RH 1.4 % RH 2.1 % RH Vaisala HMI70 temperature/ humidity indicator, salts Temperature3 – Measure (-20 to 60) °C (-270 to -210) °C (-210 to 400) °C (400 to 1370) °C (-270 to 400) °C (400 to 1370) °C (-200 to 100) °C (100 to 300) °C (300 to 500) °C (500 to 660) °C 0.25 °C 0.7 °C 0.6 °C 1.3 °C 0.6 °C 1.3 °C 0.046 °C 0.065 °C 0.085 °C 0.12 °C Vaisala HMI41 temperature/ humidity indicator Comparison to datalogger w/ type T thermocouple probe Comparison to Fluke 5500A, w/ Type T thermocouple probe Fluke/Hart 5628 PRT w/ HP 3458A Opt 002 8.5-digit multimeter Temperature3 – Measuring Equipment (-25 to 400) °C (-25 to 100) °C (100 to 300) °C (300 to 400) °C 0.6 °C 0.046 °C 0.065 °C 0.085 °C Dry well, Fluke w/ type T thermocouple probe Dry Well, Burns engineering PRT w/ HP 3458A Opt 002 8.5- digit multimeter Thermocouple3 (Wires, Probes) – (-25 to 400) °C 0.07 °C Ice bath, Dry-well, Burns engineering PRT w/ HP 3458A Opt 002 8.5-digit multimeter, Fluke 5500A Infrared Thermometers3 (-20 to 660) °C 50 °C 100 °C 200 °C 300 °C 400 °C 0.3 °C 1.4 °C 1.4 °C 1.8 °C 1.5 °C 1.6 °C Comparison to Burns Engineering PRT w/ HP 3458A Opt 002 8.5-digit multimeter, blackbody source Ɛ = 0.96, λ = (8 to 14) µm Ametek ETC-400R blackbody source (cavity) Ɛ = 0.96, λ = (8 to 14) µm
19

Extracted from the scope document; tables may not line up. View scope for the original.

Page 19 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 VII. Time & Frequency Parameter/Equipment Range CMC 2, 4, 6 (±) Comments Frequency – Measure3 (1 to 40) Hz 40 Hz to 10 kHz 10 kHz to 1 MHz (1 to 20) MHz (20 to 100) MHz 500 µHz/Hz 100 µHz/Hz 3.6 µHz/Hz + 1 Hz 0.4 Hz 2.4 Hz HP 3458A Opt 002 8.5-digit multimeter, HP 5334A counter Stopwatches & Timers3 Up to 24 hr 0.12 s Time signal receiver Tensile Testers3 Up to 24 in/min 0.14 % of rdg + 0.013 in/min Steel rule, stopwatch Rotational Indicating Devices3 Up to 30 000 rpm 0.011 % of rdg + 1.3 rpm Comparison to Ametek 1726 digital tachometer Tachometers3 (20 to 299.99) rpm (300.0 to 2999.9) rpm (3000 to 29 999) rpm 0.01 % of rdg + 0.02 rpm 0.01 % of rdg + 0.14 rpm 0.01 % of rdg + 1.4 rpm Comparison to Ametek 1965 digistrobe 1 This laboratory offers commercial calibration and dimensional testing. 2 Calibration and Measurement Capability Uncertainty (CMC)” is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
20

Extracted from the scope document; tables may not line up. View scope for the original.

Page 20 of 20 (A2LA Cert. No. 3601.14) Revised 01/24/2025 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, DL is the numerical value of the diagonal length of the device measured in inches and T represents the time, R is the numerical value of the resolution of the device. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration.
21ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

275 Orange Avenue #A, Goleta, CA, 93117, US

34.43583, -119.82764

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.