FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Poland

EKOLABOS Sp. z o.o.

ul. Duńska 9, 54-427, Wrocław, Poland

PCA|AB 1868ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
6
Standards
32
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at EKOLABOS Sp. z o.o.?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 1868Active

Accredited standards

32

Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ISO

ISO 4832Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms - Colony-count technique
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
As written on the certificate · Line 6 (PCA AB 1868)

PN-ISO 5667-5; PN-EN ISO 19458; PN-EN ISO 10523; PB-25

ISO 6058Water quality - Determination of calcium content - EDTA titrimetric method
As written on the certificate · Line 2 (PCA AB 1868)

PN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467

ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
As written on the certificate · Line 2 (PCA AB 1868)

PN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467

ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
As written on the certificate · Line 3 (PCA AB 1868)

PN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. A

ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 6888-1Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 1: Method using Baird-Parker agar medium
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
As written on the certificate · Line 2 (PCA AB 1868)

PN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467

ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
As written on the certificate · Line 3 (PCA AB 1868)

PN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. A

ISO 8467Water quality - Determination of permanganate index
As written on the certificate · Line 2 (PCA AB 1868)

PN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467

ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
As written on the certificate · Line 3 (PCA AB 1868)

PN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. A

ISO 10523Water quality - Determination of pH
As written on the certificate · Line 2 (PCA AB 1868)

PN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467

As written on the certificate · Line 6 (PCA AB 1868)

PN-ISO 5667-5; PN-EN ISO 19458; PN-EN ISO 10523; PB-25

ISO 11290-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1: Detection method
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 11290-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 2: Enumeration method
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 11731Water quality - Enumeration of LegionellaCertificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (PCA AB 1868)

PN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. A

ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
As written on the certificate · Line 3 (PCA AB 1868)

PN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. A

ISO 16212Cosmetics - Microbiology - Enumeration of yeast and mould
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
As written on the certificate · Line 3 (PCA AB 1868)

PN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. A

ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 18416Cosmetics - Microbiology - Detection of Candida albicans
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

ISO 19458Water quality - Sampling for microbiological analysis
As written on the certificate · Line 6 (PCA AB 1868)

PN-ISO 5667-5; PN-EN ISO 19458; PN-EN ISO 10523; PB-25

ISO 21149Cosmetics - Microbiology - Enumeration and detection of aerobic mesophilic bacteria
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

ISO 21150Cosmetics - Microbiology - Detection of Escherichia coli
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

ISO 21527-1Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of yeasts and moulds - Part 1: Colony count technique in products with water activity greater than 0,95
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 21527-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of yeasts and moulds - Part 2: Colony count technique in products with water activity less than or equal to 0,95
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique
As written on the certificate · Line 4 (PCA AB 1868)

PN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2

ISO 22717Cosmetics - Microbiology - Detection of Pseudomonas aeruginosa
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

ISO 22718Cosmetics - Microbiology - Detection of Staphylococcus aureus
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

EN

EN 1276Name not checked yet
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

EN 1650Name not checked yet
As written on the certificate · Line 5 (PCA AB 1868)

PN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650

EN 27888Water quality - Determination of electrical conductivity
As written on the certificate · Line 2 (PCA AB 1868)

PN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467

Scope as published by PCA

6 lines
PCA

ISO/IEC 17025

Active

AB 1868

The scope document we hold says it is valid until 2027-07-09.

View on PCA

Accredited scope, certificate AB 1868

LineDisciplineMethodMatrixRange
1chemical-Water-
2chemicalPN-EN 27888; PN-EN ISO 10523; PN-EN ISO 7027-1; PB-01 na podstawie testu Merck 1.14752.0001; PB-02 na podstawie testu Merck 1.14773.0001; PB-03 na podstawie testu Merck 1.14776.0001; PB-04 na podstawie testu Merck 1.01846.0001; PB-05 na podstawie testu Merck 1.14761.0001; PB-06 na podstawie testu Merck 1.14897.0001; PB-07 na podstawie testu Merck 1.02537.0001; PN-ISO 6059; PN-ISO 6058; PN-C-04554-4; PN-EN ISO 8467Drinking water0.1 to 2500 μS/cm; mg/l; NTU; mg/l CaCO3; mg/lO2
3biologicalPN-EN ISO 6222; PN-EN ISO 7899-2; PN-EN ISO 9308-1; PN-EN ISO 14189; PN-EN ISO 16266; PN-EN ISO 11731; PN-Z-11001-3 Zał. ADrinking water-
4foodPN-EN ISO 6579-1; PN-EN ISO 11290-1; PN-ISO 4832; PN-EN ISO 21528; PN-ISO 16649-2; PN-EN ISO 4833-1; PN-EN ISO 11290-2; PN-EN ISO 6888-1; PN-ISO 21527-1; PN-ISO 21527-2Food productsto 0.95
5biologicalPN-EN ISO 21149; PN-EN ISO 16212; PN-EN ISO 18416; PN-EN ISO 22717; PN-EN ISO 21150; PN-EN ISO 22718; PN-EN 1276; PN-EN 1650Kosmetyki; Chemiczne środki dezynfekcyjne i antyseptyczne-
6chemicalPN-ISO 5667-5; PN-EN ISO 19458; PN-EN ISO 10523; PB-25Drinking water0.1 to 800 mg/l; mV

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Duńska 9, Wrocław, 54-427, PL

51.12631, 16.97820

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.