Humboldt Scientific, Inc. dba Humboldt Mfg.

2525 Atlantic Ave., 27604, Raleigh, NC, United States

Visit website
A2LA 3956.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E4

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

3956.01

The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3956.01

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3956.01) Revised 02/27/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HUMBOLDT SCIENTIFIC, INC. dba HUMBOLDT MFG. CO. 2525 Atlantic Ave. Raleigh, NC 27604 Nestor Chonillo Phone: 708 468 6386 CALIBRATION Valid To: March 31, 2026 Certificate Number: 3956.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2 (±) Comments Linear Displacement Indicators and Transducers3 (0.008 to 0.4) in (0.4 to 1.0) in (1.0 to 2.0) in 0.000 36 in 0.0008 in 0.0044 in Micrometer head, gage blocks II. Electrical Parameter/Equipment Range CMC2 (±) Comments Electrical Density Gauge3 – Density Moisture (1775 to 2725) kg/m3 (0 to 800) kg/m3 27 kg/m3 16 kg/m3 MCU III. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Pressure Gauge3 Up to 300 psi 0.10 % Pressure calibrator
2ASTM E4-100 to 10000 lbf
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.