RATLR
9622 South Margo Drive, 85284, Tempe, AZ, United States
- Accredited standards
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-21
ANSI C63.4a:2017; ANSI C63.25.1 (2018); CISPR 16-1-4 (2019); ANSI C63.4-2014; CISPR 16-1-4:2010; CISPR 16-1-4:2010/AMD1:2012; CISPR 25:2021; IEC 61000-4-3:2020; IEC 61000-4-21:2011
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6393.01
The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 6393.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ANSI C63.4a:2017; ANSI C63.25.1 (2018); CISPR 16-1-4 (2019); ANSI C63.4-2014; CISPR 16-1-4:2010; CISPR 16-1-4:2010/AMD1:2012; CISPR 25:2021; IEC 61000-4-3:2020; IEC 61000-4-21:2011 | - | 1 to 18 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6393.01) 10/28/2024 Page 1 of 1
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the
laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration. The CMC uncertainty was originally calculated in the
linear terms (symmetrical) and converted to logarithmic values (asymmetrical).
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- TUV SUD AmericaSan Diego, CA · ~493 kmA2LAShares 1 accredited test methodANSI C63.4-2014
- International Certification ServicesGlencoe, MN · ~1,979 kmA2LAShares 1 accredited test methodANSI C63.4-2014
- TUV SUD AmericaNew Brighton, MN · ~2,059 kmA2LAShares 1 accredited test methodANSI C63.4-2014
- TUV SUD AmericaAlpharetta, GA · ~2,549 kmA2LAShares 1 accredited test methodANSI C63.4-2014
- UL LLCDurham, NC · ~3,019 kmA2LAShares 1 accredited test methodANSI C63.4-2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.