Reliability Laboratory of New H3C Technologies Co.,
466 Changhe Road, Binjiang District, Hangzhou, Zhejiang, People's Republic of China, Zhejiang,, China
Visit website- Accredited standards
- 54
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 54 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI17
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 386
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-4
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-50
ETSI EN 301 489-52
Show all 17
ETSI EN 301 893
ETSI EN 302 502
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 687
ETSI ES 201 468
IEC 61000 series16
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsExclusion
Limits written next to it
IEC 61000-6-3 (excluding IEC 61000-3-11, IEC 61000-
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-5
IEC 61000-6-8
IEC10
IEC 60571
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61850-3Exclusion
Limits written next to it
EN 61850-3 (excluding Ripple on d.c.
IEC 61850-3 (excluding Ripple on d.c.
IEC 62236-3-2
IEC 62236-4
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62920
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CNS 15936identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
EN5
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50155Railway applications - Rolling stock - Electronic equipment
EN 50385
Other standards1
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
GB/T 30094; GB/T 34120; GB/T 34133; GB/T 37408; GB/T 37409; YD/T 1082; YD/T 1312.1; YD/T 1312.8; YD/T 2583.13; YD/T 2583.14; YD/T 2583.18; YD/T 2583.17; YD/T 993; YD/T 950; NB/T 31016; NB/T 32004; IEEE 1613 (section 8 only); IEEE 1613.1 (sections 6, 8, 9 and 10 only); GR-1089-CORE (section 2 only); 3GPP TS 38.113; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 301 893 V2.1.1; ETSI EN 303 687; ETSI EN 300 440; ETSI EN 300 440 V2.1.1; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 303 413; ETSI EN 302 502; ETSI EN 302 502 V2.1.1; ANSI C63.10:2013; RSS-GEN; RSS-247 (with or without DFS); RSS-248; YD/T 3168; YD/T 2950; GB/T 32420; GB/T 12572; MIC Notice No. 88 Appendix No. 43; MIC Notice No. 88 Appendix No. 45; EN 50385; EN 62311; IEC 62311; EN 62479; IEC 62479; BS EN 50385; BS EN IEC 62311; BS EN 62479
IEC 61000-4-11; IEC 61000-4-11:2020; EN IEC 61000-4-11; EN IEC 61000-4-11:2020; BS EN IEC 61000-4-11; GB/T 17626.11; IEC 61000-4-29; IEC 61000-4-29:2000; EN 61000-4-29; EN 61000-4-29:2000; BS EN 61000-4-29; GB/T 17626.29; IEC 60571; IEC 60601-1-2; EN 60601-1-2; IEC 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN 61000-6-2; IEC 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-4; EN IEC 61000-6-4; IEC 61000-6-5; EN 61000-6-5; IEC 61000-6-8; EN IEC 61000-6-8; IEC 61850-3; EN 61850-3; IEC 62236-3-2; IEC 62236-4; IEC 62920; EN 50121-3-2; EN 50121-4; EN 50130-4; EN 50155; EN 55024; EN 55035; EN 55035:2017; EN 55035:2017+A11:2020; BS EN 55035; ETSI EN 300 386; ETSI EN 300 386 V1.6.1; ETSI EN 300 386 V2.1.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489-1; ETSI EN 301 489-1 V2.2.3; ETSI EN 301 489-17; ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-19; ETSI EN 301 489-50; ETSI EN 301 489-52; EN 301 489-52 V1.2.1; ETSI ES 201 468; CISPR 24; CISPR 35; CISPR 35:2016; GB/T 9254.2; GB/T 17618; GB/T 17799.1; GB/T 17799.2; GB 17799.3; GB 17799.4; GB/T 17799.6; GB 17799.8; GB/T 19286; GB/T 22450.1; GB/T 22451; GB/T 24338.4; GB/T 24338.5
IEC 61000-3-2; IEC 61000-3-2:2018+AMD1:2020; EN IEC 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-2:2014; EN IEC 61000-3-2:2019; EN IEC 61000-3-2:2019+A1:2021; EN IEC 61000-3-2:2019+A2:2024 ; GB 17625.1; GB 17625.1-2022; IEC 61000-3-3; IEC 61000-3-3:2013+AMD1:2017+AMD2:2021; EN 61000-3-3; BS EN 61000-3-3; EN 61000-3-3:2013; EN 61000-3-3:2013+A1:2019; EN 61000-3-3:2013+A2:2021; EN 61000-3-3:2013+A2:2021+AC:2022; GB/T 17625.2; IEC 61000-4-2; IEC 61000-4-2:2008; EN 61000-4-2; EN 61000-4-2:2009; BS EN 61000-4-2; GB/T 17626.2; IEC 61000-4-3; IEC 61000-4-3:2020; EN IEC 61000-4-3; EN IEC 61000-4-3:2020; BS EN IEC 61000-4-3; GB/T 17626.3; IEC 61000-4-4; IEC 61000-4-4:2012; EN 61000-4-4; EN 61000-4-4:2012; BS EN 61000-4-4; GB/T 17626.4; IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-5:2014+AMD1:2017; EN 61000-4-5; EN 61000-4-5:2006; EN 61000-4-5:2014+A1:2017; BS EN 61000-4-5; GB/T 17626.5; IEC 61000-4-6; IEC 61000-4-6:2023; EN IEC 61000-4-6; EN IEC 61000-4-6:2023; BS EN IEC 61000-4-6; GB/T 17626.6; IEC 61000-4-8; IEC 61000-4-8:2009; EN 61000-4-8; EN 61000-4-8:2010; BS EN 61000-4-8; GB/T 17626.8
IEC 60950-1; IEC 60950-1:2005+A1:2009+A2:2013; UL 60950-1; UL 60950-1 2nd:2014; IEC 62368-1; IEC 62368-1:2014; IEC 62368-1:2018; EN 62368-1; EN 62368-1:2014+A11:2017; UL 62368-1; UL 62368-1:2014; GB 4943.1; GB 4943.1-2022
ANSI C63.4:2014; ANSI C63.4:2003; ANSI C63.4:2009; GR-1089-CORE; GB/T 9254; GB/T 9254.1; ICES Gen; ICES-003; ICES-003 Issue 7; VCCI V-3; VCCI V-4; CNS 13438; CNS 15936; CISPR 22; AS/NZS CISPR 22; EN 55022; CISPR 32; CISPR 32:2015+AMD1:2019; EN 55032; EN 55032:2015+A11:2020; EN 55032:2015+A1:2020; BS EN 55032; AS/NZS CISPR 32; AS/NZS CISPR 32:2015+AMD1:2020; VCCI-CISPR 32; VCCI-CISPR 32:2016; CISPR 11; EN 55011; GB 4824
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active2608.01
The scope document we hold says it is valid until 2027-09-30.
Accredited scope, certificate 2608.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ANSI C63.4:2014; ANSI C63.4:2003; ANSI C63.4:2009; GR-1089-CORE; GB/T 9254; GB/T 9254.1; ICES Gen; ICES-003; ICES-003 Issue 7; VCCI V-3; VCCI V-4; CNS 13438; CNS 15936; CISPR 22; AS/NZS CISPR 22; EN 55022; CISPR 32; CISPR 32:2015+AMD1:2019; EN 55032; EN 55032:2015+A11:2020; EN 55032:2015+A1:2020; BS EN 55032; AS/NZS CISPR 32; AS/NZS CISPR 32:2015+AMD1:2020; VCCI-CISPR 32; VCCI-CISPR 32:2016; CISPR 11; EN 55011; GB 4824 | - | to 40 GHz |
| 2 | IEC 61000-3-2; IEC 61000-3-2:2018+AMD1:2020; EN IEC 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-2:2014; EN IEC 61000-3-2:2019; EN IEC 61000-3-2:2019+A1:2021; EN IEC 61000-3-2:2019+A2:2024 ; GB 17625.1; GB 17625.1-2022; IEC 61000-3-3; IEC 61000-3-3:2013+AMD1:2017+AMD2:2021; EN 61000-3-3; BS EN 61000-3-3; EN 61000-3-3:2013; EN 61000-3-3:2013+A1:2019; EN 61000-3-3:2013+A2:2021; EN 61000-3-3:2013+A2:2021+AC:2022; GB/T 17625.2; IEC 61000-4-2; IEC 61000-4-2:2008; EN 61000-4-2; EN 61000-4-2:2009; BS EN 61000-4-2; GB/T 17626.2; IEC 61000-4-3; IEC 61000-4-3:2020; EN IEC 61000-4-3; EN IEC 61000-4-3:2020; BS EN IEC 61000-4-3; GB/T 17626.3; IEC 61000-4-4; IEC 61000-4-4:2012; EN 61000-4-4; EN 61000-4-4:2012; BS EN 61000-4-4; GB/T 17626.4; IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-5:2014+AMD1:2017; EN 61000-4-5; EN 61000-4-5:2006; EN 61000-4-5:2014+A1:2017; BS EN 61000-4-5; GB/T 17626.5; IEC 61000-4-6; IEC 61000-4-6:2023; EN IEC 61000-4-6; EN IEC 61000-4-6:2023; BS EN IEC 61000-4-6; GB/T 17626.6; IEC 61000-4-8; IEC 61000-4-8:2009; EN 61000-4-8; EN 61000-4-8:2010; BS EN 61000-4-8; GB/T 17626.8 | - | 80 to 6 |
| 3 | IEC 61000-4-11; IEC 61000-4-11:2020; EN IEC 61000-4-11; EN IEC 61000-4-11:2020; BS EN IEC 61000-4-11; GB/T 17626.11; IEC 61000-4-29; IEC 61000-4-29:2000; EN 61000-4-29; EN 61000-4-29:2000; BS EN 61000-4-29; GB/T 17626.29; IEC 60571; IEC 60601-1-2; EN 60601-1-2; IEC 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN 61000-6-2; IEC 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-4; EN IEC 61000-6-4; IEC 61000-6-5; EN 61000-6-5; IEC 61000-6-8; EN IEC 61000-6-8; IEC 61850-3; EN 61850-3; IEC 62236-3-2; IEC 62236-4; IEC 62920; EN 50121-3-2; EN 50121-4; EN 50130-4; EN 50155; EN 55024; EN 55035; EN 55035:2017; EN 55035:2017+A11:2020; BS EN 55035; ETSI EN 300 386; ETSI EN 300 386 V1.6.1; ETSI EN 300 386 V2.1.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489-1; ETSI EN 301 489-1 V2.2.3; ETSI EN 301 489-17; ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-19; ETSI EN 301 489-50; ETSI EN 301 489-52; EN 301 489-52 V1.2.1; ETSI ES 201 468; CISPR 24; CISPR 35; CISPR 35:2016; GB/T 9254.2; GB/T 17618; GB/T 17799.1; GB/T 17799.2; GB 17799.3; GB 17799.4; GB/T 17799.6; GB 17799.8; GB/T 19286; GB/T 22450.1; GB/T 22451; GB/T 24338.4; GB/T 24338.5 | - | - |
| 4 | GB/T 30094; GB/T 34120; GB/T 34133; GB/T 37408; GB/T 37409; YD/T 1082; YD/T 1312.1; YD/T 1312.8; YD/T 2583.13; YD/T 2583.14; YD/T 2583.18; YD/T 2583.17; YD/T 993; YD/T 950; NB/T 31016; NB/T 32004; IEEE 1613 (section 8 only); IEEE 1613.1 (sections 6, 8, 9 and 10 only); GR-1089-CORE (section 2 only); 3GPP TS 38.113; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 301 893 V2.1.1; ETSI EN 303 687; ETSI EN 300 440; ETSI EN 300 440 V2.1.1; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 303 413; ETSI EN 302 502; ETSI EN 302 502 V2.1.1; ANSI C63.10:2013; RSS-GEN; RSS-247 (with or without DFS); RSS-248; YD/T 3168; YD/T 2950; GB/T 32420; GB/T 12572; MIC Notice No. 88 Appendix No. 43; MIC Notice No. 88 Appendix No. 45; EN 50385; EN 62311; IEC 62311; EN 62479; IEC 62479; BS EN 50385; BS EN IEC 62311; BS EN 62479 | - | - |
| 5 | IEC 60950-1; IEC 60950-1:2005+A1:2009+A2:2013; UL 60950-1; UL 60950-1 2nd:2014; IEC 62368-1; IEC 62368-1:2014; IEC 62368-1:2018; EN 62368-1; EN 62368-1:2014+A11:2017; UL 62368-1; UL 62368-1:2014; GB 4943.1; GB 4943.1-2022 | - | - |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
RELIABILITY LABORATORY OF NEW
H3C TECHNOLOGIES CO., LTD.
Zhejiang, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 8th day of July 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2608.01
Valid to September 30, 2027
Revised October 15, 2025 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014EN 300 328IEC 62368-1
- SGS-CSTC Standards Technical Services (Suzhou) Co.,SuzhouA2LAShares 3 accredited test methodsANSI C63.4:2014EN 300 328IEC 61000-4-11
- TUV SUD Certification and Testing (China) Co., Ltd. Shenzhen BranchShenzhenA2LAShares 3 accredited test methodsANSI C63.4:2014IEC 61000-4-11IEC 62368-1
- Attestation of Global Compliance (Shenzhen) Co.,GuangdongA2LAShares 2 accredited test methodsIEC 61000-3-2IEC 62368-1
- Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchDongguan City, Guangdong ProvinceA2LAShares 2 accredited test methodsIEC 61000-3-2IEC 62368-1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.