Registers refreshed 2026-11-08.See refresh dates
United Kingdom

Siemens

Digital Industries, Motion Control, Varey Road, Congleton, CW12 1PH, Cheshire, United Kingdom

Visit website
UKAS 21541ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
17
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 17 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series6
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 60068 series4
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 61800 series4
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine toolsSome clauses

Limits written next to it

1.3 – EMC Tests IEC 61800-3:2017 (clause 5.2.2)

Some clauses. Written next to it on line 3 of UKAS certificate 21541.

IEC 61800-5-1
IEC 61800-5-2
IEC 61800-9-2Some clauses

Limits written next to it

3.4 – Energy Efficiency CDM Losses IEC 61800-9-2:2017 (clause 7.7)

Some clauses. Written next to it on line 7 of UKAS certificate 21541.

IEC3
IEC 60060-1Some clauses

Limits written next to it

IEC 60060-1:2010 (clause 5&6)

Some clauses. Written next to it on line 6 of UKAS certificate 21541.

IEC 60060-1:2010 (clause 7)

Some clauses. Written next to it on line 6 of UKAS certificate 21541.

IEC 60146-1-1
IEC 61180Some clauses

Limits written next to it

IEC 61180:2016 (clause 5&6)

Some clauses. Written next to it on line 6 of UKAS certificate 21541.

IEC 61180:2016 (clause 7)

Some clauses. Written next to it on line 6 of UKAS certificate 21541.

Read from the scope as published by UKAS. Register refreshed 2026-11-06.

Scope as published by UKAS

9 lines
UKAS

ISO/IEC 17025

Active

21541

View scope

Location

Digital Industries, Motion Control, Varey Road, Congleton, Cheshire, CW12 1PH, GB

53.17158, -2.20214

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.