K & S Associates

1926 Elm Tree Drive, 37210, Nashville, TN, United States

Visit website
A2LA 1866.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 1866.01 · 7 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1866.01) 3/6/2026 Page 2 of 6 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (1 to 5) mV (5 to 50) mV 50 mV to 1000 V (50 Hz to 1 kHz) 3.0 % 0.72 % 0.22 % Multifunction calibrator Parameter/Equipment Range CMC2, 3 (±) Comments Electrometers, Charge – Generate 25 pC to 700 nC (700 to 20 000) nC 0.17 % 0.10 % Therapy & diagnostic class Electrometers, Current – Generate 2 pA to 1000 nA 0.30 % Therapy & diagnostic class II. Ionizing Radiation & Radioactivity Parameter/Equipment Range CMC2, 3 (±) Comments Ionization Chambers – Therapy Class Co60 Air Kerma Co60 Dose to Water Cs137 Air Kerma X-Rays (Series) M L ISO Narrow Spectrum Up to 44 cGy/min Up to 44 cGy/min Up to 13 cGy/min (20 to 250) kVp (50 to 100) kVp (40 to 250) kVp 1.2 % 1.1 % 1.2 % 1.2 % 1.2 % 1.2 % Reference class & therapy class detectors
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1866.01) 3/6/2026 Page 3 of 6 Parameter/Equipment Range CMC2, 3 (±) Comments Ionization Chambers – Diagnostic Class Mo/Mo W/Al, W/Cu (22 to 35) kVp (40 to 150) kVp 2.5 % 1.9 % Reference class & diagnostic class detectors Ionization Chambers – Health Physics Standards Co60Air Kerma Cs137 Air Kerma X-Rays (Series) (30 to 250) kVp M Series (40 to 250) kVp ISO Narrow Spectrum (30 to 1000) mGy/min (5 to 120) mGy/min (0.3 to 200) mGy/min (6 to 1000) μGy/min 1.2 % 1.2 % 1.2 % 1.2 % Reference class & field class detectors Radiation Protection Survey Instruments – Cs137 Air Kerma X-Rays (30 to 250) kVp M Series (40 to 250) kVp ISO Narrow Spectrum 5 μGy/min to 8 Gy/h (10 to 3000) mGy/h (0.4 to 60) mGy/h 7.8 % 7 % 7 % Geiger-Mueller tubes, scintillation detectors, semiconductor detectors & ion chambers Environmental Survey Instruments – Cs137 Air Kerma Integrating Ion Chamber (PIC) Cs137 Air Kerma (0.4 to 5) µGy/h (0.4 to 5) µGy/h 5 % 11 % Geiger-Mueller tubes, scintillation detectors, semiconductor detectors & ion chambers Clinical Survey Instruments – Cs137 Air Kerma X-rays M Series Up to 1.0 Gy/min (30 to 150) kVp 7.6 % 7.5 % Survey instruments suitable for diagnostic x-ray measurements
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1866.01) 3/6/2026 Page 4 of 6 Parameter/Equipment Range CMC2, 3 (±) Comments Brachytherapy Sources – Low Dose Rate (LDR) Pd103 I125 Cs137 Ir192 Cs131 Up to 13 µGy·m2/h Up to 25 µGy·m2/h Up to 300 µGy·m2/h Up to 100 µGy·m2/h Up to 13 µGy·m2/h 2.5 % 2.5 % 2.1 % 2.1 % 1.6 % Reference source comparison in well chamber Well Chambers for Brachytherapy Sources – Low Dose Rate (LDR) Pd103 I125 Cs137 Ir192 Cs131 High Dose Rate (HDR) Ir192 Up to 13 µGy·m2/h Up to 25 µGy·m2/h Up to 300 µGy·m2/h Up to 80 µGy·m2/h Up to 13 µGy·m2/h Up to 46 mGy·m2/h 2.5 % 2.5 % 2.2 % 2.2 % 1.6 % 3 % Reference sources & working standards with well chambers Non-Invasive kVp Measuring Instruments – Mammography – Constant Potential Radiography – Constant Potential (22 to 35) kVp (40 to 150) kVp 1.5 % 1.6 % Digital single or multifunction meters Invasive kVp Measuring Instruments – Mammography & Radiography (22 to 150) kVp 1.2 % High voltage dividers
to 13 µGy·m2/h
5ISO Narrow Spectrum-See scope document
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1866.01) 3/6/2026 Page 6 of 6 IV. Time & Frequency Parameter/Range Frequency CMC2, 3, 5 (±) Comments Frequency/Period – Measuring Equipment 3 Hz to 500 kHz 0.20 % Multifunction calibrator Non-Invasive X-ray Beam Timers (20 to 50) ms 50 ms to 1.5 s 0.70 % 0.60 % Measured with dynalyzer ___________________________________________ 1 This laboratory offers commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, all percentages are to be read as percent of reading unless otherwise noted. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
3 to 500000 Hz
7ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1926 Elm Tree Drive, Nashville, TN, 37210, US

36.16228, -86.77430

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.