A2LA certificate 1866.01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1866.01) 3/6/2026 Page 2 of 6
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Generate
(1 to 5) mV
(5 to 50) mV
50 mV to 1000 V
(50 Hz to 1 kHz)
3.0 %
0.72 %
0.22 %
Multifunction calibrator
Parameter/Equipment
Range CMC2, 3 (±) Comments
Electrometers, Charge –
Generate
25 pC to 700 nC
(700 to 20 000) nC
0.17 %
0.10 %
Therapy & diagnostic
class
Electrometers, Current –
Generate
2 pA to 1000 nA
0.30 %
Therapy & diagnostic
class
II. Ionizing Radiation & Radioactivity
Parameter/Equipment
Range CMC2, 3 (±) Comments
Ionization Chambers –
Therapy Class
Co60 Air Kerma
Co60 Dose to Water
Cs137 Air Kerma
X-Rays (Series)
M
L
ISO Narrow Spectrum
Up to 44 cGy/min
Up to 44 cGy/min
Up to 13 cGy/min
(20 to 250) kVp
(50 to 100) kVp
(40 to 250) kVp
1.2 %
1.1 %
1.2 %
1.2 %
1.2 %
1.2 %
Reference class &
therapy class detectors | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1866.01) 3/6/2026 Page 3 of 6
Parameter/Equipment
Range CMC2, 3 (±) Comments
Ionization Chambers –
Diagnostic Class
Mo/Mo
W/Al, W/Cu
(22 to 35) kVp
(40 to 150) kVp
2.5 %
1.9 %
Reference class &
diagnostic class
detectors
Ionization Chambers –
Health Physics Standards
Co60Air Kerma
Cs137 Air Kerma
X-Rays (Series)
(30 to 250) kVp M Series
(40 to 250) kVp ISO
Narrow Spectrum
(30 to 1000) mGy/min
(5 to 120) mGy/min
(0.3 to 200) mGy/min
(6 to 1000) μGy/min
1.2 %
1.2 %
1.2 %
1.2 %
Reference class & field
class detectors
Radiation Protection
Survey Instruments –
Cs137 Air Kerma
X-Rays
(30 to 250) kVp M Series
(40 to 250) kVp ISO
Narrow Spectrum
5 μGy/min to 8 Gy/h
(10 to 3000) mGy/h
(0.4 to 60) mGy/h
7.8 %
7 %
7 %
Geiger-Mueller tubes,
scintillation detectors,
semiconductor
detectors & ion
chambers
Environmental Survey
Instruments –
Cs137 Air Kerma
Integrating Ion Chamber
(PIC) Cs137 Air Kerma
(0.4 to 5) µGy/h
(0.4 to 5) µGy/h
5 %
11 %
Geiger-Mueller tubes,
scintillation detectors,
semiconductor
detectors & ion
chambers
Clinical Survey
Instruments –
Cs137 Air Kerma
X-rays M Series
Up to 1.0 Gy/min
(30 to 150) kVp
7.6 %
7.5 %
Survey instruments
suitable for diagnostic
x-ray measurements | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1866.01) 3/6/2026 Page 4 of 6
Parameter/Equipment
Range CMC2, 3 (±) Comments
Brachytherapy Sources –
Low Dose Rate (LDR)
Pd103
I125
Cs137
Ir192
Cs131
Up to 13 µGy·m2/h
Up to 25 µGy·m2/h
Up to 300 µGy·m2/h
Up to 100 µGy·m2/h
Up to 13 µGy·m2/h
2.5 %
2.5 %
2.1 %
2.1 %
1.6 %
Reference source
comparison in well
chamber
Well Chambers for
Brachytherapy Sources –
Low Dose Rate (LDR)
Pd103
I125
Cs137
Ir192
Cs131
High Dose Rate (HDR)
Ir192
Up to 13 µGy·m2/h
Up to 25 µGy·m2/h
Up to 300 µGy·m2/h
Up to 80 µGy·m2/h
Up to 13 µGy·m2/h
Up to 46 mGy·m2/h
2.5 %
2.5 %
2.2 %
2.2 %
1.6 %
3 %
Reference sources
& working standards
with well chambers
Non-Invasive kVp
Measuring Instruments –
Mammography –
Constant Potential
Radiography –
Constant Potential
(22 to 35) kVp
(40 to 150) kVp
1.5 %
1.6 %
Digital single or
multifunction meters
Invasive kVp Measuring
Instruments –
Mammography &
Radiography
(22 to 150) kVp
1.2 %
High voltage dividers | to 13 µGy·m2/h |
| 5 | ISO Narrow Spectrum | - | See scope document |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1866.01) 3/6/2026 Page 6 of 6
IV. Time & Frequency
Parameter/Range
Frequency CMC2, 3, 5 (±) Comments
Frequency/Period –
Measuring Equipment
3 Hz to 500 kHz
0.20 %
Multifunction
calibrator
Non-Invasive X-ray Beam
Timers
(20 to 50) ms
50 ms to 1.5 s
0.70 %
0.60 %
Measured with
dynalyzer
___________________________________________
1 This laboratory offers commercial calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, all percentages are to be read as percent of reading unless otherwise noted.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | 3 to 500000 Hz |
| 7 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- G.T. Michelli Co., LLC - LEBANONLebanon, TN · ~44 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - MADISONMadison, AL · ~156 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Integrity Calibration ServicesEvansville, IN · ~213 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ludlum Measurements Inc. Knoxville Calibration DivisionKnoxville, TN · ~257 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - MemphisCordova, TN · ~293 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.