Registers refreshed 2026-11-20.See refresh dates
United States

Kostal of America Test

350 Stephenson Hwy, 48083, Troy, MI, United States

Visit website
A2LA 2251.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
16
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 16 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-70
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO 16750 series4
ISO 16750-1Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 1: General
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
Other standards2
ASTM B117Standard Practice for Operating Salt Spray (Fog) ApparatusExclusion

Limits written next to it

Salt Fog ASTM B117 (excluding mass loss)

Exclusion. Written next to it on line 2 of A2LA certificate 2251.01.

ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

2251.01

The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 2251.01

LineMethodMatrixRange
1DIN 40 050; ISO 20653; MIL-STD-202G, Method 206; MIL-STD-810E501.37; ISO 16750-1; ISO 16750-2; ISO 16750-3; ISO 16750-4; IEC 60068-2-14; IEC 60068-2-30; IEC 60068-2-70; USCAR-21; SAE J1211; SAE USCAR 2; MIL-STD-810G Section 514.6; MIL-STD-202 Method 201A & 214A; IEC 60068-2-6; IEC 60068-2-64; CS-11982; MIL STD 202 G, Method 213Belectrical componentsSee scope document
2MIL-STD-810E 501.3 Procedure I & II; MIL-STD-810E 502.3 Process II; ISO 16750-4; IEC 60068-2-1A; IEC 60068-2-2B; IEC 60068-2-14; MIL-STD-202G, Method 103B; ISO 16750-2; IEC 60068-2-30; IEC-60068-2-38; IEC 60068-2-78; GM9110P; GMW3172; MIL-STD-202G, Method 107G; IEC 60068-2-38; ASTM B117; IEC 60068-2-11; ISO 16750-2; MIL-STD-202G, Methods 302,303, 307--50 to 130 °C
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited KOSTAL OF AMERICA TEST LAB Troy, MI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 30th day of October 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2251.01 Valid to October 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

350 Stephenson Hwy, Troy, MI, 48083, US

42.60559, -83.14993

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.