What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 101 standard numbers and the 52 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60601 series29
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 60601-2-1
IEC 60601-2-2
IEC 60601-2-5
IEC 60601-2-10
IEC 60601-2-11
IEC 60601-2-16
IEC 60601-2-18
IEC 60601-2-19
IEC 60601-2-20
IEC 60601-2-21
IEC 60601-2-22
Show all 29
IEC 60601-2-23
IEC 60601-2-25
IEC 60601-2-27
IEC 60601-2-28Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
IEC 60601-2-29
IEC 60601-2-31
IEC 60601-2-33Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis
IEC 60601-2-34
IEC 60601-2-36
IEC 60601-2-37
IEC 60601-2-43Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
IEC 60601-2-44Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
IEC 60601-2-45Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices
IEC 60601-2-47
IEC 60601-2-50
IEC 60601-2-52
IEC 60601-2-64
IEC 61000 series17
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-8national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-16
Show all 17
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
KS C 9610-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-4national version with changes
IEC11
IEC 60092-504
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60533
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61851-21-1
IEC 61851-21-2
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 63000
IEC 80601-2-59
IEC 80601-2-60
ETSI9
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330-2
ETSI EN 300 440-1
ETSI EN 300 440-2
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-52
IEC 61326 series8
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61326-3-1
CISPR7
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
KS C 9811national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
KS C 9814-1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
KS C 9815national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS 3548identical to it
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national
National versions in the same scope
KS C 9835national version with changes
ISO6
ISO 7176-21Wheelchairs - Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery chargers
ISO 13766-1Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 1: General EMC requirements under typical electromagnetic environmental conditions
ISO 13766-2Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 2: Additional EMC requirements for functional safety
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
ISO 22200Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity
EN5
EN 14982
EN 50085-1
EN 50270
EN 50370-1
EN 50370-2
ISO 80601 series5
ISO 80601-2-56Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
ISO 80601-2-69Medical electrical equipment - Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment
ISO 80601-2-70Medical electrical equipment - Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment
ISO 80601-2-80Medical electrical equipment - Part 2-80: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory insufficiency
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
BS 14982
FCC PART 15Radio Frequency Devices
KS C 9832
EN 50270; BS 50270; EN 55015; EN 60601-1-2; BS 60601-1-2; EN 61000-6-3; BS 61000-6-3; EN 61000-6-4; BS 61000-6-4; EN 61326-1; BS 61326-1; EN 61326-2-1; BS 61326-2-1; EN 50370-1; BS 50370-1; EN 61326-2-2; BS 61326-2-2; EN 61326-2-3; BS 61326-2-3; EN 61326-2-4; BS 61326-2-4; EN 61326-2-5; BS 61326-2-5; EN 61326-2-6; BS 61326-2-6; EN 61326-3-1; EN 61851-21-2 (Charging Systems Only); BS 61851-21-2 (Charging Systems Only); EN 55014-1; BS 55014-1; EN 62233; BS 62233; IEC 62233; EN 14982; BS 14982; ISO 14982; BS EN ISO 13766-1; BS EN ISO 13766-2; EN ISO 13766-1; EN ISO 13766-2; ISO 13766-1; ISO 13766-2; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-3; IEC 61326-2-4; CISPR 12; ICES-002; IEC 61326-2-5; IEC 61326-2-6; IEC 61851-21-1 (Charging Systems Only); CAN/CSA CISPR 12; IEC 60601-1-2 1; IEC 60601-1-2 Ed. 3.0 b:2007 1; EN 60601-1-2:2007/AC:2010; BS 60601-1-2 2007+ C 2010; EN 60601-1-2:2015; BS 60601-1-2 2015; IEC 60601-1-2 Ed. 4.0:2014 1; KS C IEC 60601-1-2; IEC 61000-6-3; KS C 9610-6-3; KS C 9610-6-4; IEC 61000-6-4; IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; CISPR 15; KS C 9814-1; KS C 9815; CNS 13438 (up to 6 GHz); CNS 15936; ISO/IEC 17025:2017
KS C 9832; CISPR 32; EN 55032; BS 55032; SI 961 Part 32; IMDA TS SRD; IEC 60533; IEC 60092-504; IEC 60945; CISPR 16-1-4; CISPR 16-2-1; CISPR 16-2-3; IEC 60601-2-64; IEC 60601-2-1; ANSI C63.27:2017; CFR 47, FCC Part 15, Part B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP-5:1986; CFR 47, FCC Part 15, Part C; ANSI C63.10:2013; ANSI C63.4:2009; ICES-001; ICES-003; VCCI-CISPR 32:2016; CNS 13438; AS/NZS 3548; EN 55011; BS 55011; KS C 9811; CISPR 11; EN IEC 61000-3-2; BS EN 61000-3-3; EN IEC 61000-3-3; IEC 60601-1-2; EN 60601-1-2:2015; BS 60601-1-2 2015; EN 60601-1-2:2007/AC:2010; BS 60601-1-2:2007/AC:2010; EN 14982; BS 14982; ISO 14982; IEC 60601-1-2 Ed. 3.0 b:2007; IEC 60601-1-2 Ed. 4.0:2014; AIM 7351731; SI 961 Part 24; EN 61547; BS 61547; EN 61000-6-1; BS 61000-6-1; EN 61000-6-2; BS 61000-6-2; EN 55024; BS 55024; EN 55035; EN 61326-1; BS 61326-1; EN 61326-3-1; EN 60601-1-2; BS 60601-1-2; EN 50270; BS 50270; EN 301 489-1; EN 61851-21-2; BS 61851-21-2; EN 301 489-3; EN 301 489-17; EN 301 489-52; IEC 61000-6-1; IEC 61000-6-2; EN 50370-2; BS 50370-2; IEC 55024; IEC 61326-1; IEC 61851-21-2; ANSI/RESNA WC-2 2009, Section 21; ISO 7176-21:2009; KS C 9835; UL 2331-2; UL 2202; UL 991; IEC 61547; IEC 60533; IEC 60092-504; IEC 60945; KS C IEC 60601
ISO 80601-2-56; IEC 80601-2-59; IEC 80601-2-60; ISO 80601-2-61; ISO 80601-2-69; ISO 80601-2-70; ISO 80601-2-80; IEC 60601-1-2; ANSI AAMI IEC 60601-1-2:2014; IEC TR 60601-4-2; CFR 47, FCC Part 15; CFR 47, FCC Part 18; ANSI C63.4:2014; ANSI C63.4:2009; EN 60601-1-2:2015; BS 60601-1-2 2015; EN 60601-1-2:2007/AC:2010; BS 60601-1-2 2007+ C 2010; IEC 60601-1-2 Ed. 4.0:2014; IEC 60601-1-2 Ed. 3.0 b:2007; EN 60601-1-2; BS 60601-1-2; EN 61000-6-3; BS 61000-6-3; EN 61000-6-4; EN 61326-1; BS 61326-1; EN 55014-1; BS 55014-1; IEC 55014-1; IEC 60601-1-2; IEC 61000-6-3; IEC 61000-6-4; IEC 61326-1; CISPR 14-1; EN 50370-1; EN 55011; EN 55022; BS 55022; ICES-001; ICES-003; ICES-002; CISPR 11; CISPR 12; CISPR 22; CISPR 32; CAN/CSA CISPR 12; EN 14982; ISO 14982; EN 61000-6-1; EN 61000-6-2; BS 61000-6-2; EN 55024; ISO 14982; EN 61326-1; BS 61326-1; IEC 61000-6-1; IEC 61000-6-2; IEC 55024; IEC 61326-1; EN 50370-2; IEC 60601-1-2; CISPR 35; EN 55035; CISPR 14-2; CISPR 24; ISO 22200; EN 61000-4-2; BS 61000-4-2; IEC 61000-4-2; EN 61000-4-3; BS 61000-4-3; IEC 61000-4-3; EN 61000-4-4; BS 61000-4-4; IEC 61000-4-4
KS C 9610-4-2; EN 61000-4-3; BS 61000-4-3; IEC 61000-4-3; KS C 9610-4-3; EN 61000-4-4; BS 61000-4-4; IEC 61000-4-4; KS C 9610-4-4; EN 61000-4-5; BS 61000-4-5; IEC 61000-4-5; KS C 9610-4-5; EN IEC 61000-4-12; BS EN IEC 61000-4-12; EN 61000-4-6; BS 61000-4-6; IEC 61000-4-6; KS C 9610-4-6; EN 61000-4-8; BS 61000-4-8; IEC 61000-4-8; KS C 9610-4-8; EN 61000-4-11; BS 61000-4-11; IEC 61000-4-11; KS C 9610-4-11; EN IEC 61000-4-29; EN IEC 61000-4-13; BS EN IEC 61000-4-13; IEC 61000-4-16; EN 61000-4-16; BS 61000-4-16; CFR 47, FCC Part 15, Subpart C (using ANSI C63.10:2013); CFR 47, FCC Part 15, Subpart E (without DFS), (using ANSI C63.10:2013); RSS-GEN, Issue 5 (April 2018, Amendment 1 – March 2019, Amendment 2 – February 2021); RSS-210 (Issue 11, June 2024); RSS-247 (without DFS), Issue 4 (July 2025); EN 300 220-2; EN 300 328; EN 300 330-2; EN 300 440-1; EN 300 440-2; IMDA TS SRD; IEEE C95.1; IEEE C95.3; ICNIRP Guidelines Vol. 74 #4; DO 160-Sections 21 and 25; NFPA 1982- Sections 8.19-8.23; IEC 60601-2-1 Edition 4.0 2020-10; IEC 60601-2-10 Edition 2.1 2016-04; IEC 60601-2-11 Edition 3.0 2013-01; ANSI AAMI IEC 60601-2-16:2018; IEC 60601-2-18: Edition 3.0 2009-08; ANSI AAMI IEC 60601-2-19 Edition 2.1 2016-04; ANSI AAMI IEC 60601-2-19 Edition 3.0 2020-09; ANSI AAMI IEC 60601-2-2:2017
ANSI AAMI IEC 60601-2-20 Edition 2.1 2016-04; ANSI AAMI IEC 60601-2-20 Edition 3.0 2020-09; ANSI AAMI IEC 60601-2-21 Edition 2.1 2016-04; ANSI AAMI IEC 60601-2-21 Edition 3.0 2020-09; IEC 60601-2-22 Edition 3.1 2012-10; IEC 60601-2-22 Edition 4.0 2019-11; IEC 60601-2-23 Edition 3.0 2011-02; IEC 60601-2-25 Edition 2.0 2011-10; ANSI AAMI IEC 60601-2-25:2011/(R)2016; ANSI AAMI IEC 60601-2-25 Edition 2.0 2011-10; ANSI AAMI IEC 60601-2-27:2011(R)2016; IEC 60601-2-28 Edition 2.0 2010-03; IEC 60601-2-28 Edition 3.0 2017-06; IEC 60601-2-29 Edition 3.0 2008-06; IEC 60601-2-31 Edition 2.1 2011-09; IEC 60601-2-33 Edition 4.0 2022-08; IEC 60601-2-34 Edition 3.0 2011-05; IEC 60601-2-36 Edition 2.0 2014-04; IEC 60601-2-37 Edition 2.1 2015; IEC 60601-2-37 Edition 3.0 2024-07; IEC 60601-2-43 - Ed. 2.0 2010-03; IEC 60601-2-43 Edition 2.1 2017-05; IEC 60601-2-43 Edition 3.0 2022-12; IEC 60601-2-44 Edition 3.2: 2016; IEC 60601-2-45 Edition 3.1 2015; ANSI AAMI IEC 60601-2-47:2012/(R)2016; IEC 60601-2-5: Edition 3.0 2009-07; ANSI AAMI IEC 60601-2-50 Edition 2.1 2016-04; IEC 60601-2-50 Edition 3.0 2020-09; IEC 60601-2-52 Edition 1.1 2015-03
IEC/EN: 60335-1; IEC/EN: 60730-1; BS: 60335-1; BS: 60730-1; ANSI/CAN/UL 2849; UL: 122; UL: 469; UL: 813; UL: 1459; UL: 1492; UL: 2044; UL: 3044; UL: 60065-1; UL: 60950-1; UL: 62368-1; CSA: 107.3; CSA: 60065-1; CSA: 60950-1; CSA: 62368-1; IEC/EN/BS: 60065-1; IEC/EN/BS: 60950-1; IEC/EN/BS: 60950-22; IEC/EN/BS: 60945; IEC/EN/BS: 62040-1; IEC/EN/BS: 62368-1; AS/NZS: 60065-1; AS/NZS: 60950-1; AS/NZS: 62040-1; AS/NZS: 62368-1; BS: 60950-1; BS: 60950-22; BS: 62368-1; UL: 48; UL: 482; UL: 153; UL: 298; UL: 496; UL: 542; UL: 676; UL: 924; UL: 935; UL: 970; UL: 1029; UL: 1088; UL: 1230; UL: 1573; UL: 1574; UL: 1598; UL: 1786; UL: 1838; UL: 1993; UL: 2108; UL: 2703; UL: 8750; UL: 60598-1; CSA: 12; CSA: 89; CSA: 166; CSA: 207; CSA: 250; CSA: E60598-1; IEC/EN: 60598-1; IEC/EN: 61347-1; BS: 60598-1; BS: 61347-1; UL: 506; UL: 697; UL: 1012; UL: 1236; UL: 1310; UL: 1561; UL: 1562; UL: 1585; UL: 2161; CSA: 47; CSA: 107.1; CSA: 107.2; UL: 45; UL: 987; UL: 1447; UL: 1448; UL: 60745-1; UL: 62841-1; CSA: 60745-1; CSA: 62841-1; IEC/EN: 60745-1; IEC/EN: 62841-1; BS: 60745-1; BS: 62841-1; UL: 50; UL: 50e; UL: 514; CSA: 0.4; CSA: 94-1; CSA: 94-2; IEC/EN 60529; BS 60529; NEMA 250; ISO 20653
UL: 609; UL: 696; UL: 869a; UL: 961; UL: 962; UL: 969; UL: 1097; UL: 1244; UL: 1418; UL: 2305; UL: 2361; UL: 4200A; EN 50085-1; EN/IEC 63000; CSA 203; SPE1000; SPE3000; AAMI TIR101; ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
11 lines
ISO/IEC 17025
Active793.02
The scope document we hold says it is valid until 2027-11-30.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Bay Area ComplianceSunnyvale, CA · ~3,510 kmA2LAShares 3 accredited test methodsANSI C63.4:2014EN 61000-4-3KS C 9832
- UL LLCNorthbrook, IL · ~565 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 60601-1-2
- TUV Rheinland of North AmericaPleasanton, CA · ~3,490 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 60601-1-2
- Clark Dynamic Testing Laboratory, Inc.Jefferson Hills, PA · ~162 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Intertek Testing Services NAKentwood, MI · ~408 kmA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .