FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Poland

Zakład Badań Środowiskowych Andrzej Kropiwiec

ul. Rysia 5, 05-075, Warszawa-Wesoła, Poland

PCA|AB 863ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Zakład Badań Środowiskowych Andrzej Kropiwiec?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 863Active

Certificates and scope

1
PCA

ISO/IEC 17025

Active

AB 863

The scope document we hold says it is valid until 2027-12-20.

View on PCA

Accredited scope, certificate AB 863

LineDisciplineMethodMatrixRange
1environmental-building items, machinery and devices; working environment (harmful factors - air); working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate, energy expenditure); general environment (physical factors – noise, ventilation)-
2environmentalPN-EN ISO 9612:2011; PN-N-01307:1994; PN-87/B-02156; PN-EN ISO 10052:2007; PN-EN ISO 10052:2007/A1:2010; PN-EN ISO 16032:2006; PN-EN ISO 3382-2:2010; PN-EN ISO 3746:2011; PN-EN ISO 3746:2011/Ap1:2017-09Workplace environment23 to 136 dB
3environmentalPN-ISO 9613-2:2002; PN-EN 1838:2013-11General environment0.5 to 10000 lx; s; dB
4environmentalPN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011; PN-EN 12599:2013-04; PB-06, wyd. 1 z dnia 05.04.2018 r.Workplace environment0.06 to 50 m/s2
5environmentalPN-EN ISO 7243:2018-01; PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04; PN-Z-04008-7:2002+Az1:2004Air0.15 to 85 °C; %; m/s
6chemicalPN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB-05, wyd. 1 z dnia 25.01.2017 r.; PN-Z-04476:2016-10; PN-Z-04224-3:2003Air0.05 to 1182 mg/m3; ppm; mg w próbce
7chemicalPB-07 wyd. 5 z dnia 06.12.2024 r.Ambient air0.032 to 4000 mg/m3; ppm; mg w próbce; mg/próbkę
8chemicalPB-07 wyd. 5 z dnia 06.12.2024 r.; PB-08 wyd. 3 z dnia 06.12.2024 r.Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z sorbentem; Środowisko pracy - powietrze - próbki powietrza pobrane na rurki0.008 to 3000 mg/m3; mg w próbce; ppm

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Rysia 5, Warszawa-Wesoła, 05-075, PL

52.25409, 21.22409

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.