Poland
Zakład Badań Środowiskowych Andrzej Kropiwiec
ul. Rysia 5, 05-075, Warszawa-Wesoła, Poland
PCA|AB 863ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
8
Locations
1
Contact this laboratory
Work at Zakład Badań Środowiskowych Andrzej Kropiwiec?
Claim this profile to keep it accurate.
Claim this profileRegister record
- PCACollected
- AB 863Active
Certificates and scope
1PCA
ISO/IEC 17025
ActiveAB 863
Accredited scope, certificate AB 863
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | PB-07 wyd. 5 z dnia 06.12.2024 r. | Ambient air | 0.032 to 4000 mg/m3; ppm; mg w próbce; mg/próbkę |
| chemical | PB-07 wyd. 5 z dnia 06.12.2024 r.; PB-08 wyd. 3 z dnia 06.12.2024 r. | Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z sorbentem; Środowisko pracy - powietrze - próbki powietrza pobrane na rurki | 0.008 to 3000 mg/m3; mg w próbce; ppm |
| chemical | PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB-05, wyd. 1 z dnia 25.01.2017 r.; PN-Z-04476:2016-10; PN-Z-04224-3:2003 | Air | 0.05 to 1182 mg/m3; ppm; mg w próbce |
| environmental | PN-EN ISO 7243:2018-01; PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04; PN-Z-04008-7:2002+Az1:2004 | Air | 0.15 to 85 °C; %; m/s |
| environmental | PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011; PN-EN 12599:2013-04; PB-06, wyd. 1 z dnia 05.04.2018 r. | Workplace environment | 0.06 to 50 m/s2 |
| environmental | PN-ISO 9613-2:2002; PN-EN 1838:2013-11 | General environment | 0.5 to 10000 lx; s; dB |
| environmental | - | building items, machinery and devices; working environment (harmful factors - air); working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate, energy expenditure); general environment (physical factors – noise, ventilation) | - |
| environmental | PN-EN ISO 9612:2011; PN-N-01307:1994; PN-87/B-02156; PN-EN ISO 10052:2007; PN-EN ISO 10052:2007/A1:2010; PN-EN ISO 16032:2006; PN-EN ISO 3382-2:2010; PN-EN ISO 3746:2011; PN-EN ISO 3746:2011/Ap1:2017-09 | Workplace environment | 23 to 136 dB |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Poland
- Zakład Wykonywania Pomiarów EMITOROpole · ~288 kmPCAShares 6 accredited methods and materialsEN ISO 9612:2011PN-Z-04507:2022-05Air
- Zakład Badań Środowiska Pracy Izabela GrabowskaWarszawa · ~11 kmPCAShares 5 accredited methods and materialsEN ISO 5349-1:2004EN ISO 7243:2018-01PN-Z-04507:2022-05
- TES LABORATORIUM Spółka z ograniczoną odpowiedzialnościąWarszawa · ~21 kmPCAShares 5 accredited methods and materialsEN ISO 5349-1:2004PN-Z-04507:2022-05Air
- Laboratorium Ochrony Środowiska PracySiedlce · ~72 kmPCAShares 5 accredited methods and materialsEN ISO 7243:2018-01PN-Z-04507:2022-05Air
- Ośrodek Badań Podstawowych Projektów i Wdrożeń Ochrony Środowiska i Biotechnologii "OIKOS"Święta Katarzyna · ~152 kmPCAShares 5 accredited methods and materialsEN ISO 5349-1:2004PN-Z-04507:2022-05Air
Accreditation data collected from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.