1701 Quincy Avenue, Suite 32, 60540, Naperville, IL, United States

Visit website
A2LA 1395.07ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
10
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 10 scope lines.

A2LA certificate 1395.07 · 10 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 2 of 9 Parameter/Equipment Range CMC2, 4, 5, 9 (±) Comments DC Current3 – Measure (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 39 µA/A + 64 pA 29 µA/A + 130 pA 28 µA/A + 1.1 nA 28 µA/A + 7.5 nA 28 µA/A + 75 nA 44 µA/A + 0.75 µA 0.013 % + 16 µA HP 3458A, opt 2 DC Current – Clamp-On Meters (10 to 25) A (25 to 150) A (150 to 1025) A 0.62 % + 0.02 A 0.62 % + 0.14 A 0.63 % + 0.5 A Fluke 5520A/SC1100, Fluke 5500A/coil Resistance3 – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 40 µΩ/Ω + 1 mΩ 24 µΩ/Ω + 1.5 mΩ 22 µΩ/Ω + 1.4 mΩ 29 µΩ/Ω + 2 mΩ 22 µΩ/Ω + 2 mΩ 52 µΩ/Ω + 0.02 Ω 22 µΩ/Ω + 0.02 Ω 25 µΩ/Ω + 0.2 Ω 22 µΩ/Ω + 0.2 Ω 44 µΩ/Ω + 2 Ω 28 µΩ/Ω + 2 Ω 52 µΩ/Ω + 30 Ω 0.011 % + 50 Ω 0.028 % + 2.5 kΩ 0.042 % + 3 kΩ 0.24 % + 80 kΩ 1.2 % + 400 kΩ Fluke 5520A/SC1100 Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1000) MΩ 19 µΩ/Ω + 90 µΩ 16 µΩ/Ω + 0.9 mΩ 14 µΩ/Ω + 1 mΩ 14 µΩ/Ω + 10 mΩ 14 µΩ/Ω + 90 mΩ 20 µΩ/Ω + 3 Ω 62 µΩ/Ω + 120 Ω 0.059 % + 4 kΩ 0.58 % + 260 kΩ HP 3458A, opt 2
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 3 of 9 Parameter/Equipment Range CMC2, 4, 9 (±) Comments Capacitance – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 109.999 99) nF (110 to 329.999) nF (0.33 to 1.9999) µF (2 to 3.2999) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.9999) µF (110 to 329.9999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.44 % + 8.1 pF 0.44 % + 8.1 pF 0.42 % + 8.1 pF 0.24 % + 8.1 pF 0.23 % + 85 pF 0.23 % + 0.24 nF 0.23 % + 0.8 nF 0.23 % + 2.3 nF 0.24 % + 7.8 nF 0.34 % + 23 nF 0.38 % + 78 nF 0.38 % + 230 nF 0.37 % + 0.8 µF 0.37 % + 2.3 µF 0.37 % + 7.8 µF 0.59 % + 23 µF 0.86 % + 78 µF Fluke 5520A Oscilloscopes3 – Square Wave Signal 10 Hz to 10 kHz 50 Ω Impedance 1 MΩ Impedance DC Signal 10 Hz to 10 kHz 50 Ω Impedance 1 MΩ Impedance Level Sine Amp – 50 Ω 50 kHz Ref. Level Sine Flatness – 50 Ω 5 mV to 5.5 V Relative to 50 kHz Ref. Time Marker – 50 Ω Rise Time 1 kHz to 10 MHz 1 mV to 6.6 V pk – pk 1 mV to 130 Vpk - pk 1 mV to 6.6 V 1 mV to 130 V 10 mV to 5 V (p-p) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 2 ns to 20 ms (50 to 5) s (250 to 350) ps 0.26 % + 100 µV 0.13 % + 100 µV 0.25 % + 40 µV 0.052 % + 40 µV 2 % + 300 µV 1.8 % + 100 µV 1.8 % + 100 µV 3.2 % + 100 µV 2.5 parts in 10 6 s (25 + 1000·t) µs/s 160 ps Fluke 5520A/SC1100 t = time in seconds
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 4 of 9 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators & Indicating Systems3 – Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.5 °C 0.16 °C 0.14 °C 0.16 °C 0.21 °C 0.27 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.16 °C 0.26 °C 0.4 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 5 of 9 Parameter/Range Frequency CMC2, 4, 9 (±) Comments AC Voltage3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.078 % + 6 µV 0.02 % + 6 µV 0.05 % + 6 µV 0.1 % + 6 µV 0.28 % + 12 µV 0.66 % + 50 µV 0.027 % + 8 µV 0.018 % + 8 µV 0.019 % + 8 µV 0.032 % + 8 µV 0.064 % + 32 µV 0.16 % + 70 µV 0.027 % + 40 µV 0.018 % + 50 µV 0.020 % + 50 µV 0.027 % + 40 µV 0.056 % + 100 µV 0.19 % + 70 µV 0.027 % + 0.65 mV 0.018 % + 0.6 mV 0.023 % + 0.6 mV 0.03 % + 0.6 mV 0.071 % + 1.6 mV 0.02 % + 2 mV 0.021 % + 6 mV 0.024 % + 6 mV 0.024 % + 6 mV 0.16 % + 50 mV 0.024 % + 10 mV 0.02 % + 10 mV 0.024 % + 10 mV Fluke 5520A/SC1100
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 6 of 9 Parameter/Range Frequency CMC2, 5, 9 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.04 % + 3.5 µV 0.025 % + 1.3 µV 0.035 % + 1.3 µV 0.14 % + 1.3 µV 0.58 % + 1.3 µV 4.6 % + 2.5 µV 90 µV/V + 5 µV 90 µV/V + 2.5 µV 0.017 % + 2.5 µV 0.036 % + 2.5 µV 0.093 % + 2.5 µV 0.35 % + 15 µV 1.2 % + 15 µV 90 µV/V + 50 µV 90 µV/V + 25 µV 0.017 % + 25 µV 0.035 % + 25 µV 0.092 % + 25 µV 0.35 % + 130 µV 1.2 % + 130 µV 90 µV/V + 0.5 mV 90 µV/V + 0.25 mV 0.017 % + 0.25 mV 0.035 % + 0.25 mV 0.093 % + 0.25 mV 0.35 % + 1.5 mV 1.2 % + 1.5 mV 0.03 % + 5 mV 0.03 % + 2.5 mV 0.024 % + 2.5 mV 0.041 % + 2.5 mV 0.14 % + 2.5 mV HP 3458A, opt 2
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 7 of 9 Parameter/Range Frequency CMC2, 4, 5, 9 (±) Comments AC Voltage – Measure3 (cont) (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.05 % + 50 mV 0.05 % + 25 mV 0.07 % + 25 mV 0.14 % + 25 mV 0.35 % + 25 mV HP 3458A, opt 2 AC Current – Generate3 (30 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A 45 Hz to 1 kHz 100 Hz to 1 kHz 0.1 % + 0.1 µA 0.078 % + 0.15 µA 0.032 % + 2 µA 0.032 % + 20 µA 0.04 % + 0.1 mA 0.05 % + 0.1 mA 0.081 % + 2 mA 0.12 % + 5 mA Fluke 5520A/SC1100; LCOMP off AC Current – Measure3 (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 45 Hz to 1 kHz (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz (45 to 100) Hz 100 Hz to 5 kHz 0.075 % + 0.04 µA 0.072 % + 0.25 µA 0.041 % + 0.25 µA 0.072 % + 2.5 µA 0.041 % + 2.5 µA 0.072 % + 25 µA 0.041 % + 25 µA 0.10 % + 0.25 mA 0.12 % + 0.25 mA HP 3458A, opt 2
100 to 1000 V
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 8 of 9 Parameter/Range Frequency CMC2, 4, 9 (±) Comments AC Current – Clamp on Meter (10 to 25) A (25 to 150) A (150 to 1000) A (45 to 60) Hz (64 to 440) Hz (45 to 60) Hz (64 to 440) Hz (45 to 60) Hz (64 to 440) Hz 0.71 % + 0.03 A 1.3 % + 0.03 A 0.71 % + 0.25 A 1.7 % + 0.25 A 0.74 % + 0.9 A 1.6 % + 0.9 A Fluke 5520A/SC1100, Fluke 5500A/coil II. Mechanical Parameter/Equipment Range CMC2, 6, 8 (±) Comments Torque Wrenches – Measure (20 to 200) ozf∙in (5 to 50) lbf∙in (40 to 400) lbf∙in (100 to 1000) lbf∙in (25 to 250) lbf∙ft 0.61 % 0.96 % 0.62 % 0.82 % 0.60 % CDI torque transducers III. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency3 – Measuring Equipment 10 MHz 0.01 Hz to 2 MHz 0.85 mHz 1.9 µHz/Hz + 5 µHz HP 58503A GPS Fluke 5520A ___________________________________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.07) Revised 04/16/2025 Page 9 of 9 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Based on using the standard at the temperature the Fluke 5520A with SC1100 was calibrated (tcal ± 5 °C) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 °C. For resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. 5 Based on using the standard at the temperature the HP 3458A was calibrated (tcal ± 5 °C) and an auto- calibration (ACAL) was performed within the previous 24 hours (± 1 °C of ambient). 6 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
10ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1701 Quincy Avenue, Suite 32, Naperville, IL, 60540, US

41.77287, -88.14793

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.