Florida Metrology, LLC d/b/a Acme Metrology
Villa Park, IL, United States
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 3864.02 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 2 of 10
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Crimpers – Functional
Diameter
(0.011 to 0.060) in
(0.061 to 0.250) in
58 µin
60 µin
Pin gages
Rulers & Tape Measures
Up to 48 in
0.6R µin
Gage blocks
II. Electrical DC/Low Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Voltage3 – Generate
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(100 to 1000) V
25 µV/V + 1 µV
14 µV/V + 2 µV
15 µV/V + 20 µV
22 µV/V + 150 µV
22 µV/V + 1.5 mV
Fluke 5520A
DC Voltage3 – Measure
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
8.8 µV
39 µV
350 µV
5.6 mV
61 mV
Fluke 8846A
DC Current3 – Measure
(0 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
(100 to 400) mA
400 mA to 1 A
(1 to 3) A
(3 to 10) A
0.091 µA
0.66 µA
9.5 µA
66 µA
270 µA
840 µA
3.0 mA
18 mA
Fluke 8846A
DC Current3 – Generate
(0 to 329.999) µA
330 µA to 3.299 99 mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
0.018 % + 0.02 µA
0.012 % + 0.05 µA
0.012 % + 0.25 µA
0.013 % + 2.5 µA
0.024 % + 40 µA
0.046 % + 40 µA
0.06 % + 500 µA
0.12 % + 750 µA
Fluke 5520A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 3 of 10
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current3 – Generate
(cont)
Clamp-On Meters:
Toroidal
Non-Toroidal
(50 to 1000) A
(50 to 1000) A
0.39 % + 0.5 A
0.65 % + 0.5 A
With Fluke
5500/coil
Resistance3 – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
110 Ω to 1.1 kΩ
(1.1 to 11) kΩ
(11 to 110) kΩ
110 KΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
54 µΩ/Ω + 0.001 Ω
37 µΩ/Ω + 0.0015 Ω
35 µΩ/Ω + 0.0014 Ω
35 µΩ/Ω + 0.002 Ω
36 µΩ/Ω + 0.02 Ω
36 µΩ/Ω + 0.2 Ω
41 µΩ/Ω + 2 Ω
74 µΩ/Ω + 30 Ω
0.016 % + 50 Ω
0.031 % + 2.5 kΩ
0.062 % + 3 kΩ
0.37 % + 100 kΩ
1.8 % + 500 kΩ
Fluke 5520A
Resistance3 – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
4.7 mΩ
15 mΩ
130 mΩ
1.5 Ω
15 Ω
96 Ω
3.1 kΩ
0.97 MΩ
24 MΩ
Fluke 8846A
Capacitance3 – Generate
(3.3 to 11) nF
(11 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
330 µF to 1.1 mF
(1.1 to 3.3) mF
(3.3 to 11) mF
0.34 % + 0.01 nF
0.32 % + 0.1 nF
0.32 % + 0.3 nF
0.32 % + 1 nF
0.32 % + 3 nF
0.32 % + 10 nF
0.5 % + 30 nF
0.57 % + 100 nF
0.57 % + 300 nF
0.58 % + 300 nF
0.56 % + 3 µF
0.56 % + 10 µF
Fluke 5520A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 4 of 10
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Capacitance – Measure
(0 to 1) nF
(1 to 10) nF
(10 to 100) nF
100 nF to 1 µF
(1 to 10) µF
(10 to 100) µF
100 µF to 1 mF
(1 to 10) mF
(10 to 100) mF
0.091 nF
0.19 nF
1.9 nF
18 nF
180 nF
1.9 µF
19 µF
190 µF
5.2 mF
Fluke 8846A
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Measure
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(50 to 100) kHz
120 µV
120 µV
210 µV
5.4 mV
1.1 mV
1.1 mV
2.0 mV
54 mV
11 mV
11 mV
2.2 mV
2000 mV
110 mV
110 mV
200 mV
820 mV
990 mV
990 mV
1000 mV
3000 mV
Fluke 8846A
AC Voltage – Generate3
(0 to 33) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
0.099 % + 6 µV
0.021 % + 6 µV
0.026 % + 6 µV
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 5 of 10
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Generate
(cont)
(0 to 33) mV
(33 to 330) mV
33 mV to 3.3 V
(2.3 to 33) V
(33 to 330) V
(330 to 1020) V
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 10 kHz
0.12 % + 6 µV
0.42 % + 12 µV
0.96 % + 50 µV
0.040 % + 8 µV
0.018 % + 8 µV
0.020 % + 8 µV
0.043 % + 8 µV
0.097 % + 32 µV
0.24 % + 70 µV
0.040 % + 50 µV
0.019 % + 60 µV
0.023 % + 60 µV
0.037 % + 50 µV
0.085 % + 130 µV
0.29 % + 600 µV
0.04 % + 650 µV
0.019 % + 600 µV
0.029 % + 600 µV
0.043 % + 600 µV
0.11 % + 1.6 mV
0.024 % + 2 mV
0.025 % + 6 mV
0.031 % + 6 mV
0.038 % + 6 mV
0.24 % + 50 mV
0.36 % + 10 mV
Fluke 5520A
AC Current3 – Measure
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1.0 A
(1 to 3) A
(3 to 10) A
20 Hz to 10 kHz
20 Hz to 10 kHz
20 Hz to 10 kHz
20 Hz to 10 kHz
20 Hz to 10 kHz
20 Hz to 10 kHz
20 Hz to 10 kHz
0.25 µA
1.7 µA
2.9 µA
170 µA
1.7 mA
5.6 mA
25 mA
Fluke 8846A | ||
| 6 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 6 of 10
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate
(29 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(20.5 to 1000) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 1 kHz
(1 to 5) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(50 to 400) Hz
0.24 % + 0.1 µA
0.18 % + 0.1 µA
0.15 % + 0.1 µA
0.36 % + 0.15 µA
0.96 % + 0.2 µA
1.9 % + 0.4 µA
0.25 % + 0.15 µA
0.16 % + 0.15 µA
0.13 % + 0.15 µA
0.25 % + 0.2 µA
0.6 % + 0.3 µA
1.2 % + 0.6 µA
0.22 % + 2 µA
0.11 % + 2 µA
0.05 % + 2 µA
0.10 % + 2 µA
0.24 % + 3 µA
0.48 % + 4 µA
0.22 % + 20 µA
0.11 % + 20 µA
0.05 % + 20 µA
0.12 % + 50 µA
0.24 % + 100 µA
0.48 % + 200 µA
0.22 % + 100 µA
0.06 % + 100 µA
0.72 % + 1 mA
3 % + 5 mA
0.22 % + 100 µA
0.08 % + 100 µA
0.72 % + 1 mA
3 % + 5 mA
0.13 % + 2 mA
3.6 % + 2 mA
0.19 % + 5 mA
3.6 % + 5 mA
0.43 % + 0.5 A
Fluke 5520A
Fluke 5520A with
Fluke 5500/coil | See scope document |
| 7 | - | RTD Indicators & Controllers; Temperature IndicatorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 7 of 10
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators &
Controllers
PT 385, 100 Ω, 1000 Ω
(-200 to 0) °C
(0 to 200) °C
(200 to 600) °C
0.27 °C
0.37 °C
0.55 °C
Fluke 753/754
Electrical Calibration of
Temperature Indicators
3 –
Type E5
Type J
Type K
Type R
5
Type S5
Type T
5
(-200 to -100) °C
(-100 to 600) °C
(600 to 1000) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
(-200 to -100) °C
(-100 to 400) °C
(400 to 1200) °C
(1200 to 1372) °C
(0 to 100) °C
(100 to 1767) °C
(0 to 200) °C
(200 to 1400) °C
(1400 to 1767) °C
(-200 to 0) °C
(0 to 400) °C
0.44 °C
0.72 °C
0.67 °C
0.47 °C
0.35 °C
0.66 °C
0.53 °C
0.37 °C
0.44 °C
0.44 °C
1.8 °C
1.6 °C
1.8 °C
1.9 °C
1.9 °C
0.71 °C
0.61 °C
Fluke 744 | See scope document |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 8 of 10
III. Mechanical
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Scales & Balances3 –
(1 to 500) mg
Up to 5 g
Up to 10 g
Up to 20 g
Up to 50 g
Up to 100 g
Up to 200 g
Up to 500 g
Up to 1000 g
(> 1 to 19) kg
(5 to 10) g
(10 to 500) g
501 g to 25 kg
(> 20 to 5000) kg
Up to 1000 lb
(1000 to 120 000) lb
0.013 mg + 0.6R
0.042 mg + 0.6R
0.061 mg + 0.6R
0.091 mg + 0.6R
0.15 mg + 0.6R
0.31 mg + 0.6R
0.61 mg + 0.6R
1.5 mg + 0.6R
3.1 mg + 0.6R
3.1 mg per 1000 g + 0.6R
0.04 % + 0.6R
0.024 % + 0.6R
0.017 % + 0.6R
0.017 % per 20 kg + 0.6R
0.017 % + 0.6R
0.017 % per 1000 lb + 0.6R
ASTM Class 1
weights
Class F weights
Class F weights
Force3 – Compression &
Tension Measure
Up to 220 lbf
0.05 % IV
Class 6 weights
Torque – Wrenches
(10 to 200) lbf·in
(120 to 1200) lbf·in
(720 to 7200) lbf·in
1.2 lbf·in
5.3 lbf·in
23 lbf·in
Precision
TMH600F
horizontal master
torque tester
Pressure Gages3
Hydraulic
Absolute
(-14 to 0) psi
(0 to 15) psi
(0 to 30) psi
(0 to 300) psi
(0 to 500) psi
(0 to 1000) psi
(1000 to 10 000) psi
(0 to 100) psia
0.013 psi
0.012 psi
0.023 psi
0.061 psi
0.29 psi
0.60 psi
0.068 psi
0.062 psia
Fluke 744 with
pressure modules
Deadweight tester
with reference gage
Fluke 744 with
pressure modules | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 9 of 10
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature3 –
Measuring Equipment
(-32 to 375) °C
(-32 to 375) °C
(-50 to 275) °C
(275 to 400) °C
(400 to 600) °C
0.32 °C
0.14 °C
1.5 °C
2.2 °C
2.9 °C
Dry block
temperature calibrator
Temperature calibrator
with SPRT
Fluke 744 &
thermocouple probe
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Frequency – Measuring
Equipment
0.01 Hz to 2 MHz
12 µHz/Hz + 5 µHz
Fluke 5520A
________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, the percent is defined as the percentage of reading, unless otherwise noted, L
is the numerical value of the nominal length measured in inches, R is the resolution of the device under
test, and IV is defined as Indicated Value.
5 Fluke applicable to digital controllers only.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 10 of 10
7 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 11 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- DicksonAddison, IL · ~5 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GraftelRoselle, IL · ~14 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - ChicagoNaperville, IL · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Chicago, ILArlington Heights, IL · ~21 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- J. H. MetrologyRolling Meadows, IL · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.