Florida Metrology, LLC d/b/a Acme Metrology

Villa Park, IL, United States

Visit website
A2LA 3864.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
11
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 11 scope lines.

A2LA certificate 3864.02 · 11 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 2 of 10 Parameter/Equipment Range CMC2, 4 (±) Comments Crimpers – Functional Diameter (0.011 to 0.060) in (0.061 to 0.250) in 58 µin 60 µin Pin gages Rulers & Tape Measures Up to 48 in 0.6R µin Gage blocks II. Electrical DC/Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage3 – Generate (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (100 to 1000) V 25 µV/V + 1 µV 14 µV/V + 2 µV 15 µV/V + 20 µV 22 µV/V + 150 µV 22 µV/V + 1.5 mV Fluke 5520A DC Voltage3 – Measure (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 8.8 µV 39 µV 350 µV 5.6 mV 61 mV Fluke 8846A DC Current3 – Measure (0 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA (100 to 400) mA 400 mA to 1 A (1 to 3) A (3 to 10) A 0.091 µA 0.66 µA 9.5 µA 66 µA 270 µA 840 µA 3.0 mA 18 mA Fluke 8846A DC Current3 – Generate (0 to 329.999) µA 330 µA to 3.299 99 mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A 0.018 % + 0.02 µA 0.012 % + 0.05 µA 0.012 % + 0.25 µA 0.013 % + 2.5 µA 0.024 % + 40 µA 0.046 % + 40 µA 0.06 % + 500 µA 0.12 % + 750 µA Fluke 5520A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 3 of 10 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current3 – Generate (cont) Clamp-On Meters: Toroidal Non-Toroidal (50 to 1000) A (50 to 1000) A 0.39 % + 0.5 A 0.65 % + 0.5 A With Fluke 5500/coil Resistance3 – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω 110 Ω to 1.1 kΩ (1.1 to 11) kΩ (11 to 110) kΩ 110 KΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 54 µΩ/Ω + 0.001 Ω 37 µΩ/Ω + 0.0015 Ω 35 µΩ/Ω + 0.0014 Ω 35 µΩ/Ω + 0.002 Ω 36 µΩ/Ω + 0.02 Ω 36 µΩ/Ω + 0.2 Ω 41 µΩ/Ω + 2 Ω 74 µΩ/Ω + 30 Ω 0.016 % + 50 Ω 0.031 % + 2.5 kΩ 0.062 % + 3 kΩ 0.37 % + 100 kΩ 1.8 % + 500 kΩ Fluke 5520A Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 4.7 mΩ 15 mΩ 130 mΩ 1.5 Ω 15 Ω 96 Ω 3.1 kΩ 0.97 MΩ 24 MΩ Fluke 8846A Capacitance3 – Generate (3.3 to 11) nF (11 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF 330 µF to 1.1 mF (1.1 to 3.3) mF (3.3 to 11) mF 0.34 % + 0.01 nF 0.32 % + 0.1 nF 0.32 % + 0.3 nF 0.32 % + 1 nF 0.32 % + 3 nF 0.32 % + 10 nF 0.5 % + 30 nF 0.57 % + 100 nF 0.57 % + 300 nF 0.58 % + 300 nF 0.56 % + 3 µF 0.56 % + 10 µF Fluke 5520A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 4 of 10 Parameter/Equipment Range CMC2, 7 (±) Comments Capacitance – Measure (0 to 1) nF (1 to 10) nF (10 to 100) nF 100 nF to 1 µF (1 to 10) µF (10 to 100) µF 100 µF to 1 mF (1 to 10) mF (10 to 100) mF 0.091 nF 0.19 nF 1.9 nF 18 nF 180 nF 1.9 µF 19 µF 190 µF 5.2 mF Fluke 8846A Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (50 to 100) kHz 120 µV 120 µV 210 µV 5.4 mV 1.1 mV 1.1 mV 2.0 mV 54 mV 11 mV 11 mV 2.2 mV 2000 mV 110 mV 110 mV 200 mV 820 mV 990 mV 990 mV 1000 mV 3000 mV Fluke 8846A AC Voltage – Generate3 (0 to 33) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz 0.099 % + 6 µV 0.021 % + 6 µV 0.026 % + 6 µV Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 5 of 10 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (0 to 33) mV (33 to 330) mV 33 mV to 3.3 V (2.3 to 33) V (33 to 330) V (330 to 1020) V (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 10 kHz 0.12 % + 6 µV 0.42 % + 12 µV 0.96 % + 50 µV 0.040 % + 8 µV 0.018 % + 8 µV 0.020 % + 8 µV 0.043 % + 8 µV 0.097 % + 32 µV 0.24 % + 70 µV 0.040 % + 50 µV 0.019 % + 60 µV 0.023 % + 60 µV 0.037 % + 50 µV 0.085 % + 130 µV 0.29 % + 600 µV 0.04 % + 650 µV 0.019 % + 600 µV 0.029 % + 600 µV 0.043 % + 600 µV 0.11 % + 1.6 mV 0.024 % + 2 mV 0.025 % + 6 mV 0.031 % + 6 mV 0.038 % + 6 mV 0.24 % + 50 mV 0.36 % + 10 mV Fluke 5520A AC Current3 – Measure (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1.0 A (1 to 3) A (3 to 10) A 20 Hz to 10 kHz 20 Hz to 10 kHz 20 Hz to 10 kHz 20 Hz to 10 kHz 20 Hz to 10 kHz 20 Hz to 10 kHz 20 Hz to 10 kHz 0.25 µA 1.7 µA 2.9 µA 170 µA 1.7 mA 5.6 mA 25 mA Fluke 8846A
6-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 6 of 10 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate (29 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (20.5 to 1000) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 45 Hz to 1 kHz (1 to 5) kHz (50 to 400) Hz 0.24 % + 0.1 µA 0.18 % + 0.1 µA 0.15 % + 0.1 µA 0.36 % + 0.15 µA 0.96 % + 0.2 µA 1.9 % + 0.4 µA 0.25 % + 0.15 µA 0.16 % + 0.15 µA 0.13 % + 0.15 µA 0.25 % + 0.2 µA 0.6 % + 0.3 µA 1.2 % + 0.6 µA 0.22 % + 2 µA 0.11 % + 2 µA 0.05 % + 2 µA 0.10 % + 2 µA 0.24 % + 3 µA 0.48 % + 4 µA 0.22 % + 20 µA 0.11 % + 20 µA 0.05 % + 20 µA 0.12 % + 50 µA 0.24 % + 100 µA 0.48 % + 200 µA 0.22 % + 100 µA 0.06 % + 100 µA 0.72 % + 1 mA 3 % + 5 mA 0.22 % + 100 µA 0.08 % + 100 µA 0.72 % + 1 mA 3 % + 5 mA 0.13 % + 2 mA 3.6 % + 2 mA 0.19 % + 5 mA 3.6 % + 5 mA 0.43 % + 0.5 A Fluke 5520A Fluke 5520A with Fluke 5500/coil
See scope document
7-RTD Indicators & Controllers; Temperature Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 7 of 10 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators & Controllers PT 385, 100 Ω, 1000 Ω (-200 to 0) °C (0 to 200) °C (200 to 600) °C 0.27 °C 0.37 °C 0.55 °C Fluke 753/754 Electrical Calibration of Temperature Indicators 3 – Type E5 Type J Type K Type R 5 Type S5 Type T 5 (-200 to -100) °C (-100 to 600) °C (600 to 1000) °C (-200 to -100) °C (-100 to 800) °C (800 to 1200) °C (-200 to -100) °C (-100 to 400) °C (400 to 1200) °C (1200 to 1372) °C (0 to 100) °C (100 to 1767) °C (0 to 200) °C (200 to 1400) °C (1400 to 1767) °C (-200 to 0) °C (0 to 400) °C 0.44 °C 0.72 °C 0.67 °C 0.47 °C 0.35 °C 0.66 °C 0.53 °C 0.37 °C 0.44 °C 0.44 °C 1.8 °C 1.6 °C 1.8 °C 1.9 °C 1.9 °C 0.71 °C 0.61 °C Fluke 744
See scope document
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 8 of 10 III. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Scales & Balances3 – (1 to 500) mg Up to 5 g Up to 10 g Up to 20 g Up to 50 g Up to 100 g Up to 200 g Up to 500 g Up to 1000 g (> 1 to 19) kg (5 to 10) g (10 to 500) g 501 g to 25 kg (> 20 to 5000) kg Up to 1000 lb (1000 to 120 000) lb 0.013 mg + 0.6R 0.042 mg + 0.6R 0.061 mg + 0.6R 0.091 mg + 0.6R 0.15 mg + 0.6R 0.31 mg + 0.6R 0.61 mg + 0.6R 1.5 mg + 0.6R 3.1 mg + 0.6R 3.1 mg per 1000 g + 0.6R 0.04 % + 0.6R 0.024 % + 0.6R 0.017 % + 0.6R 0.017 % per 20 kg + 0.6R 0.017 % + 0.6R 0.017 % per 1000 lb + 0.6R ASTM Class 1 weights Class F weights Class F weights Force3 – Compression & Tension Measure Up to 220 lbf 0.05 % IV Class 6 weights Torque – Wrenches (10 to 200) lbf·in (120 to 1200) lbf·in (720 to 7200) lbf·in 1.2 lbf·in 5.3 lbf·in 23 lbf·in Precision TMH600F horizontal master torque tester Pressure Gages3 Hydraulic Absolute (-14 to 0) psi (0 to 15) psi (0 to 30) psi (0 to 300) psi (0 to 500) psi (0 to 1000) psi (1000 to 10 000) psi (0 to 100) psia 0.013 psi 0.012 psi 0.023 psi 0.061 psi 0.29 psi 0.60 psi 0.068 psi 0.062 psia Fluke 744 with pressure modules Deadweight tester with reference gage Fluke 744 with pressure modules
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 9 of 10 IV. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature3 – Measuring Equipment (-32 to 375) °C (-32 to 375) °C (-50 to 275) °C (275 to 400) °C (400 to 600) °C 0.32 °C 0.14 °C 1.5 °C 2.2 °C 2.9 °C Dry block temperature calibrator Temperature calibrator with SPRT Fluke 744 & thermocouple probe V. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measuring Equipment 0.01 Hz to 2 MHz 12 µHz/Hz + 5 µHz Fluke 5520A ________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, the percent is defined as the percentage of reading, unless otherwise noted, L is the numerical value of the nominal length measured in inches, R is the resolution of the device under test, and IV is defined as Indicated Value. 5 Fluke applicable to digital controllers only. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.02) Revised 06/09/2026 Page 10 of 10 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
11ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.