G.T. Michelli Company, LLC - BATON ROUGE
9663 Mammoth Drive, 70814, Baton Rouge, LA, United States
Visit website- Scope lines
- 14
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 14 scope lines.
A2LA certificate 3601.03 · 14 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 2 of 13
Parameter/Equipment
Range
CMC2 (±)
Comments
Location8
Length & Travel
Indicators
Up to 1 in
Up to 6 in
56 µin
480 µin
P&W
Supermicrometer
TM
Gage blocks &
granite surface
plate
BTR
BTR
Height Gages3
Up to 24 in
95 µin
Gage blocks &
granite surface
plate
BTR
II. Electrical DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Location8
DC Voltage –
Generate
3
Up to 120 mV
(0.12 to 1.2) V
(0 to 12) V
(12 to 120) V
(120 to 1020) V
37 µV/V + 1.6 µV
24 µV/V + 2.0 µV
24 µV/V + 20 µV
33 µV/V + 200 µV
33 µV/V + 2000 µV
Fluke 5540A
BTR
DC Current –
Generate3
Up to 120 µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
110 µA/A + 7.2 nA
85 µA/A + 18 nA
85 µA/A + 96 nA
100 µA/A + 4.0 µA
470 µA/A + 12 µA
290 µA/A + 180 µA
360 µA/A + 300 µA
1.9 mA/A + 0.6 mA
Fluke 5540A
BTR
DC Voltage –
Measure
3
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1050) V
8.0 µV/V + 0.30 µV
7.3 µV/V + 0.30 µV
7.0 µV/V + 0.5 µV
9.4 µV/V + 30 µV
13 µV/V + 100 µV
Keysight 3458A
BTR | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 3 of 13
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Location8
DC Current –
Measure3
Up to 100 µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
35 µA/A + 0.000 80 µA
18 µA/A + 0.0050 µA
20 µA/A + 0.050 µA
36 µA/A + 0.50 µA
100 µA/A + 10 µA
Keysight
3458A
BTR
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Location8
AC Voltage –
Generate3
Up to 12 mV
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.20 % + 15 µV
0.20 % + 15 µV
0.03 % + 7.0 µV
0.15 % + 7.0 µV
0.25 % + 18 µV
0.30 % + 36 µV
0.30 % + 36 µV
0.15 % + 15 µV
0.15 % + 15 µV
0.03 % + 7.0 µV
0.15 % + 20 µV
0.25 % + 26 µV
0.30 % + 400 µV
0.30 % + 400 µV
0.15 % + 150 µV
0.15 % + 150 µV
0.03 % + 85 µV
0.15 % + 200 µV
0.20 % + 260 µV
0.20 % + 4 mV
0.50 % + 4 mV
0.15 % + 1.5 mV
0.15 % + 1.5 mV
0.03 % + 0.5 mV
0.15 % + 2.0 mV
0.20 % + 2.6 mV
0.30 % + 40 mV
0.50 % + 40 mV
Fluke 5540A
BTR | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 4 of 13
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Location8
AC Voltage –
Generate3 (cont)
(12 to 120) V
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 10 kHz
0.15 % + 15 mV
0.15 % + 15 mV
0.06 % + 4 mV
0.20 % + 20 mV
0.50 % + 26 mV
0.15 % + 0.016 V
0.15 % + 0.016 V
0.07 % + 0.016 V
0.80 % + 390 mV
1.0 % + 520 mV
0.15 % + 150 mV
0.15 % + 150 mV
0.07 % + 100 mV
Fluke 5540A
BTR
AC Voltage –
Measure
3
Up to 100 mV
(0.1 to 1) V
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300 kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300 kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
0.0072 % + 0.0048 mV
0.0096 % + 0.0024 mV
0.017 % + 0.0024 mV
0.031 % + 0.0024 mV
0.092 % + 0.0024 mV
0.41 % + 0.012 mV
1.3 % + 0.012 mV
4.1 % + 0.084 mV
4.2 % + 0.096 mV
15 % + 0.12 mV
0.0082 % + 0.000 048 V
0.0086 % + 0.000 024 V
0.016 % + 0.000 024 V
0.036 % + 0.000 024 V
0.079 % + 0.000 024 V
0.32 % + 0.000 12 V
0.99 % + 0.000 12 V
4.0 % + 0.000 84 V
4.1 % + 0.000 96 V
15 % + 0.0012 V
Keysight
3458A
BTR | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 5 of 13
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Location8
AC Voltage –
Measure3 (cont)
(1 to 10) V
(10 to 100) V
(100 to 750) V
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300 kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 10) kHz
(20 to 50) kHz
(50 to 100) kHz
0.016 % + 0.000 48 V
0.0086 % + 0.000 24 V
0.016 % + 0.000 24 V
0.033 % + 0.000 24 V
0.082 % + 0.000 24 V
0.32 % + 0.0012 V
0.99 % + 0.0012 V
4.0 % + 0.0084 V
4.0 % + 0.0096 V
15 % + 0.012 V
0.020 % + 0.0048 V
0.021 % + 0.0024 V
0.022 % + 0.0024 V
0.036 % + 0.0024 V
0.12 % + 0.0024 V
0.041 % + 0.040 V
0.047 % + 0.020 V
0.063 % + 0.020 V
0.12 % + 0.020 V
0.30 % + 0.020 V
Keysight
3458A
BTR
AC Current –
Generate3
(Up to 120) µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.15 % + 20 nA
0.03 % + 20 nA
0.03 % + 20 nA
0.5 % + 150 nA
1.2 % + 1 µA
0.15 % + 200 nA
0.03 % + 200 nA
0.03 % + 200 nA
0.5 % + 300 nA
1.2 % + 5 µA
0.15 % + 2.0 µA
0.03 % + 2.0 µA
0.03 % + 2.0 µA
0.5 % + 3.0 µA
1.2 % + 10 µA
Fluke 5540A
BTR | 1 to 10 V |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 6 of 13
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Location8
AC Current –
Generate3 (cont)
(12 to 120) mA
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
0.15 % + 20 µA
0.03 % + 20 µA
0.03 % + 20 µA
0.5 % + 30 µA
1.2 % + 100 µA
0.15 % + 100 µA
0.03 % + 100 µA
0.03 % + 100 µA
0.5 % + 300 µA
1.2 % + 300 µA
0.1 % + 1 mA
0.1 % + 1 mA
0.25 % + 1 mA
0.5 % + 1.5 mA
0.15 % + 2 mA
0.15 % + 2 mA
0.3 % + 2 mA
0.5 % + 4 mA
0.3 % + 50 mA
0.3 % + 50 mA
0.5 % + 50 mA
Fluke 5540A
BTR
AC Current –
Measure3
(Up to 100) µA
(0.1 to 1) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.4 % + 0.03 µA
0.15 % + 0.03 µA
0.06 % + 0.03 µA
0.06 % + 0.03 µA
0.4 % + 0.3 µA
0.15 % + 0.2 µA
0.06 % + 0.2 µA
0.03 % + 0.2 µA
0.06 % + 0.2 µA
0.4 % + 0.4 µA
0.55 % + 1.5 µA
Keysight
3458A
BTR | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 7 of 13
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Location8
AC Current –
Measure3 (cont)
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
0.4 % + 0.3 µA
0.15 % + 0.3 µA
0.06 % + 0.3 µA
0.03 % + 0.2 µA
0.06 % + 0.2 µA
0.4 % + 0.4 µA
0.55 % + 1.5 µA
0.4 % + 3 µA
0.15 % + 3 µA
0.06 % + 3 µA
0.03 % + 2 µA
0.06 % + 2 µA
0.4 % + 4 µA
0.55 % + 15 µA
0.4 % + 0.2 mA
0.16 % + 0.2 mA
0.08 % + 0.2 mA
0.1 % + 0.2 mA
0.3 % + 0.2 mA
1 % + 0.4 mA
Keysight
3458A
BTR
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Location8
Resistance –
Generate
3
Up to 12 Ω
(12 to 120) Ω
(0.12 to 1.2) kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
(0.12 to 1.2) MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(120 to 1200) MΩ
50 µΩ/Ω + 10 mΩ
50 µΩ/Ω + 0.0012 Ω
0.0076 % + 0.0011 Ω
0.0075 % + 0.0016 Ω
0.0073 % + 0.000 0016 kΩ
0.0071 % + 0.000 016 kΩ
0.0070 % + 0.000 016 kΩ
0.0071 % + 0.00016 kΩ
0.0088 % + 0.000 16 kΩ
Fluke 5540A
BTR | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 8 of 13
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Location8
Resistance –
Measure3
Up to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
17 µΩ/Ω + 0.000 050 Ω
15 µΩ/Ω + 0.000 50 Ω
18 µΩ/Ω + 0.000 000 50 kΩ
14 µΩ/Ω + 0.000 0050 kΩ
14 µΩ/Ω + 0.000 050 kΩ
220 µΩ/Ω + 0.000 0020 MΩ
180 µΩ/Ω + 0.000 10 MΩ
0.087 % + 0.0010 MΩ
0.41 % + 0.000 010 GΩ
0.087 % + 0.0010 MΩ
0.41 % + 0.000 010 GΩ
Keysight
3458A
BTR
Capacitance –
Generate
Up to 1.2 nF
(1.2 to 12) nF
(12 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
0.43 % + 5 pF
0.27 % + 10 pF
0.19 % + 50 pF
0.19 % + 500 pF
0.19 % + 5 nF
0.27 % + 50 nF
0.35 % + 500 nF
0.35 % + 5 µF
0.78 % + 50 µF
Fluke
5540A
BTR
Electrical Calibration
of Thermocouple
Indicators
3 –
Generate & Measure
Type B
Type C
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
0.34 °C
0.26 °C
0.23 °C
0.26 °C
0.19 °C
0.16 °C
0.20 °C
0.35 °C
0.61 °C
Fluke
5540A
BTR | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 9 of 13
Parameter/Equipment
Range
CMC2 (±)
Comments
Location8
Electrical Calibration
of Thermocouple
Indicators3 –
Generate & Measure
(cont)
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.31 °C
0.11 °C
0.09 °C
0.12 °C
0.16 °C
0.19 °C
0.10 °C
0.09 °C
0.11 °C
0.16 °C
0.22 °C
0.10 °C
0.09 °C
0.16 °C
0.27 °C
0.26 °C
0.12 °C
0.09 °C
0.09 °C
0.16 °C
0.40 °C
0.23 °C
0.21 °C
0.26 °C
0.33 °C
0.24 °C
0.25 °C
0.32 °C
0.47 °C
0.16 °C
0.10 °C
0.09 °C
Fluke 5540A
BTR | ||
| 10 | ASTM Class 5 | - | See scope document |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 11 of 13
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Location8
Pressure – Measuring
Equipment3
(-14.1 to 0) psig
(0 to 2) psig
(0 to 15) psig
(0 to 30) psig
(0 to 100) psig
(0 to 500) psig
(0 to 1000) psig
(0 to 1500) psig
(0 to 3000) psig
(0 to 5000) psig
(0 to 10 000) psig
(0 to 20 000) psig
(0 to 40 000) psig
0.0026 psig
0.00049 psig
0.0023 psig
0.0034 psig
0.017 psig
0.045 psig
0.17 psig
0.21 psig
0.34 psig
0.61 psig
1.8 psig
3.9 psig
6.5 psig
Digital test gauges
BTR
Torque – Measuring
Equipment
(5 to 50) lbf·in
(50 to 500) lbf·in
(25 to 250) lbf·ft
(100 to 1000) lbf·ft
(250 to 2500) lbf·ft
(750 to 7500) lbf·ft
(2500 to 25 000) lbf·ft
0.018 lbf·in
0.3 lbf·in
0.15 lbf·ft
0.37 lbf·ft
15 lbf·ft
45 lbf·ft
150 lbf·ft
Mountz torque
transducers
AWS torque
transducers
BTR
BTR
Accelerometers3
(5 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
5.4 %
1.6 %
4.0 %
IMI Sensors
699A07 portable
vibration
calibrator
BTR
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Location8
Temperature – Measure3
(-197 to 0) °C
(0 to 157) °C
(157 to 232) °C
(232 to 420) °C
(420 to 660) °C
(-195 to - 40) °C
(- 40 to 0) °C
(0 to 230) °C
(230 to 420) °C
0.027 °C
0.027 °C
0.027 °C
0.029 °C
0.053 °C
0.071 °C
0.061 °C
0.068 °C
0.1 °C
Fluke 9144 field
metrology well
with
Fluke 5609 PRT
Additel ADT282
Readout
w/AccuMac
AM1640 PRT
BTR
BTR | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 12 of 13
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Location8
Temperature –
Measuring Equipment3
(-25 to 140) °C
Up to 50 °C
(50 to 200) °C
(200 to 420) °C
(420 to 550) °C
(550 to 660) °C
Up to 50 °C
(50 to 200) °C
(200 to 420) °C
(420 to 550) °C
(550 to 660) °C
0.037 °C
0.15 °C
0.11 °C
0.14 °C
0.17 °C
0.2 °C
0.027 °C
0.027 °C
0.027 °C
0.029 °C
0.053 °C
Fluke 7109A
Portable bath
w/Fluke 5609
PRT
Fluke 9144 field
metrology well
Fluke 9144
field metrology
well with
Fluke 5609
PRT
BTR
BTR
BTR
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Location8
Frequency –
Measuring Equipment3
0.01 Hz to 120 Hz
120 Hz to 1.2 MHz
(1.2 to 2) MHz
48 µHz/Hz
58 µHz/Hz
290 µHz/Hz
Fluke 5540A
BTR
___________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could ret in the actual measurement uncertainty achievable on a
customer’s site being larger than the CMC. | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.03) 11/05/2024 Page 13 of 13
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 In the statement of CMC, L is length in inches.
8 The locations that can perform the calibrations are given by a letter code given in the table below . The
field locations below are service locations and all calibrations are performed at customer sites:
Location Code
(Main Location) 9663 Mammoth Drive, Baton Rouge,
LA 70814 BTR
(Field Location) 103 North Pat Street, Suite H, Scott,
LA 70583 SCT | ||
| 14 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- JM Test Systems, LLC.Baton Rouge, LA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cal-TecBroussard, LA · ~82 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - HARAHANHarahan, LA · ~110 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- JM Test Systems, LLC.Alexandria, LA · ~154 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - JACKSONJackson, MS · ~227 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.