JM Test Systems, LLC.
1600 Watterberg Way, 71303, Alexandria, LA, United States
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Sites in our directory
- 5
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 1995.02 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 10 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 2 of 16
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5, 6 (±)
Comments
DC Voltage – Generate
3, 8
Up to 330 mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
17 µV/V + 1 µV
9.9 µV/V + 2 µV
11 µV/V + 20 µV
15 µV/V + 0.15 mV
15 µV/V + 1.5 mV
Fluke 5520A
DC Voltage – Measure
3, 8
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) kV
11 µV/V + 0.3 µV
10 µV/V + 0.3 µV
10 µV/V + 0.5 µV
13 µV/V + 30 µV
14 µV/V + 100 µV
0.23 %
Agilent 3458A
Fluke 80E10, DMM
DC Current – Generate
3, 8
Current Clamps
3, 8
(0 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
0.012 % + 0.02 µA
0.0079 % + 0.05 µA
0.0081 % + 0.25 µA
0.0084 % + 2.5 µA
0.018 % + 40 µA
0.031 % + 40 µA
0.043 % + 0.5 mA
0.08 % + 0.75 mA
0.19 % + 0.002 A
0.20 % + 0.015 A
0.21 % + 0.05 A
Fluke 5520A
Fluke 5520A + 50 turn
coil
DC Current – Measure
3, 8
(10 to 100) μA
(0.10 to 1.0) mA
(1.0 to 10) mA
(10 to 100) mA
(0.10 to 1) A
(1 to 1000) A
35 µA/A + 0.8 nA
35 µA/A + 5 nA
40 µA/A + 50 nA
53 µA/A + 0.5 µA
0.018 % + 10 µA
0.12 %
Agilent 3458A
Empro shunts & Agilent
3458A | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 3 of 16
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Power – Generate
3, 8
Up to 109 µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 109) W
(109 to 337) W
(337 to 990) W
(0.99 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
5.5 W to 16.8 kW
(16.8 to 153) kW
(153 to 1045) kW
0.018 %
0.010 %
0.0091 %
0.0089 %
0.0089 %
0.0090 %
0.0090 %
0.0093 %
0.022 %
0.032 %
0.048 %
0.084 %
0.19 %
0.20 %
0.21 %
Fluke 5520A
Fluke 5520A + 50 turn
coil
Resistance – Generate,
Fixed Points
3, 8 for
Insulation Testers
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
0.012 MΩ
0.12 MΩ
1.2 MΩ
0.012 GΩ
0.24 GΩ
5.8 GΩ
Fixed resistors
Resistance – Generate3, 8
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 33) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
40 µΩ/Ω + 0.001 Ω
29 µΩ/Ω + 0.0015 Ω
29 µΩ/Ω + 0.0014 Ω
35 µΩ/Ω + 0.002 Ω
28 µΩ/Ω + 0.002 Ω
25 µΩ/Ω + 0.02 Ω
25 µΩ/Ω + 0.02 Ω
25 µΩ/Ω + 0.2 Ω
24 µΩ/Ω + 0.2 Ω
33 µΩ/Ω + 2 Ω
32 µΩ/Ω + 2 Ω
53 µΩ/Ω + 30 Ω
0.012 % + 50 Ω
0.022 % + 2.5 kΩ
0.049 % + 3 kΩ
0.29 % + 0.1 MΩ
1.3 % + 0.5 MΩ
Fluke 5520A | to 1045 kW |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 4 of 16
Parameter/Equipment
Range
CMC2, 4, 5, 6 (±)
Comments
Resistance– Measure
3, 8
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(0 to 100) MΩ
10 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 100) GΩ
21 µΩ/Ω + 50 µΩ
18 µΩ/Ω + 0.5 mΩ
17 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 5 mΩ
19 µΩ/Ω + 50 mΩ
24 µΩ/Ω + 2 Ω
70 µΩ/Ω + 100 Ω
0.06 % + 1 kΩ
77 μΩ/Ω
0.54 %
0.70 %
Agilent 3458A
Voltage source & µA
range of 3458A
Capacitance – Generate
3, 8
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.49 % + 0.01 nF
0.4 % + 0.01 nF
0.41 % + 0.01 nF
0.23 % + 0.01 nF
0.2 % + 0.1 nF
0.2 % + 0.1 nF
0.2 % + 0.3 nF
0.21 % + 1 nF
0.22 % + 3 nF
0.22 % + 10 nF
0.36 % + 30 nF
0.36 % + 0.1 µF
0.36 % + 0.3 µF
0.36 % + 1 µF
0.42 % + 3 µF
0.41 % + 10 µF
0.77 % + 30 µF
0.86 % + 100 µF
Fluke 5520A
Capacitance –
Measure
3, 8
300 pF to 1000 nF
(1 to 300) µF
(300 to 1100) µF
0.05 %
0.12 %
0.15 %
GenRad 1689M
RLC Digibridge | 0 to 100 GΩ |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 5 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators –
Generate & Measure
3, 8
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.12 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.20 °C
0.31 °C
0.31 °C
0.18 °C
0.16 °C
0.15 °C
0.21 °C
0.44 °C
0.27 °C
0.26 °C
0.31 °C
0.36 °C
0.28 °C
0.29 °C
0.36 °C
0.49 °C
0.20 °C
0.13 °C
0.12 °C
Fluke 5520A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 6 of 16
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Electrical Calibration of
RTD Indicators –
Generate
3, 8
Pt 385, 100 W
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.04 °C
0.04 °C
0.04 °C
0.07 °C
0.08 °C
0.09 °C
0.19 °C
Fluke 5520A
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Generate
3, 8
(1.0 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
3.9 % + 170 µV
0.063 % + 6 µV
0.015 % + 6 µV
0.019 % + 6 µV
0.079 % + 6 µV
0.27 % + 12 µV
0.62 % + 50 µV
3.9 % + 1700 µV
0.025 % + 8 µV
0.012 % + 8 µV
0.013 % + 8 µV
0.028 % + 8 µV
0.063 % + 32 µV
0.16 % + 70 µV
3.9 % + 17 000 µV
0.024 % + 50 µV
0.012 % + 60 µV
0.015 % + 60 µV
0.024 % + 50 µV
0.055 % + 0.13 mV
0.19 % + 0.6 mV
Fluke 5520A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 7 of 16
Parameter/Range
Frequency
CMC2, 4, 5, 6 (±)
Comments
AC Voltage – Generate
3, 8
(cont)
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
3.9 % + 170 mV
0.024 % + 0.65 mV
0.012 % + 0.6 mV
0.019 % + 0.6 mV
0.028 % + 0.6 mV
0.071 % + 1.6 mV
0.016 % + 2 mV
0.016 % + 6 mV
0.02 % + 6 mV
0.029 % + 6 mV
0.16 % + 50 mV
0.026 % + 10 mV
0.02 % + 10 mV
0.024 % + 10 mV
Fluke 5520A
AC Voltage – Measure
3, 8
(0 to 10) mV
(10 to 100) mV
(0.10 to 1.0) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.051 % + 3 µV
0.056 % + 1.1 µV
0.083 % + 1.1 µV
0.46 % + 1.1 µV
0.78 % + 1.1 µV
4.7 % + 2 µV
0.013 % + 4 µV
0.016 % + 2 µV
0.027 % + 2 µV
0.12 % + 2 µV
0.23 % + 2 µV
0.41 % + 10 µV
1.2 % + 10 µV
0.011 % + 40 µV
0.016 % + 20 µV
0.024 % + 20 µV
0.041 % + 20 µV
0.11 % + 20 µV
0.36 % + 100 µV
1.2 % + 100 µV
Agilent 3458A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 8 of 16
Parameter/Range
Frequency CMC
2, 4, 5, 6 (±) Comments
AC Voltage – Measure3, 8
(cont)
(1 to 10) V
(10 to 100) V
(100 to 750) V
(0.75 to 10) kV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
60 Hz
0.029 % + 0.4 mV
0.012 % + 0.2 mV
0.02 % + 0.2 mV
0.037 % + 0.2 mV
0.095 % + 0.2 mV
0.36 % + 1 mV
1.2 % + 1 mV
0.025 % + 4 mV
0.025 % + 2 mV
0.026 % + 2 mV
0.048 % + 2 mV
0.15 % + 2 mV
0.47 % + 10 mV
1.7 % + 10 mV
0.048 % + 40 mV
0.048 % + 20 mV
0.07 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
0.23 %
Agilent 3458A
Fluke 80E10, DMM
AC Current – Generate
3, 8
(29 to 330) µA
(0.33 to 3.3) mA
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
3.9 % + 1.7 µA
0.16 % + 0.1 µA
0.12 % + 0.1 µA
0.1 % + 0.1 µA
0.24 % + 0.15 µA
0.62 % + 0.2 µA
1.3 % + 0.4 µA
3.9 % + 17 µA
0.16 % + 0.15 µA
0.1 % + 0.15 µA
0.081 % + 0.15 µA
0.16 % + 0.2 µA
0.39 % + 0.3 µA
0.78 % + 0.6 µA
Fluke 5520A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 9 of 16
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate
3, 8
(cont)
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
3.9 % + 170 µA
0.15 % + 2 µA
0.072 % + 2 µA
0.036 % + 2 µA
0.065 % + 2 µA
0.16 % + 3 µA
0.31 % + 4 µA
3.9 % + 1700 µA
0.15 % + 20 µA
0.073 % + 20 µA
0.037 % + 20 µA
0.081 % + 50 µA
0.16 % + 0.1 mA
0.31 % + 0.2 mA
0.15 % + 0.1 mA
0.045 % + 0.1 mA
0.052 % + 1 mA
1.9 % + 5 mA
0.15 % + 0.1 mA
0.051 % + 0.1 mA
0.47 % + 1 mA
1.9 % + 5 mA
0.06 % + 2 mA
0.086 % + 2 mA
2.3 % + 2 mA
0.098 % + 5 mA
0.12 % + 5 mA
2.3 % + 5 mA
Fluke 5520A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 10 of 16
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate
3, 8
(cont)
LCOMP On
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3) A
(3 to 20.5) A
Current Clamps
3, 8
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
(100 to 440) Hz
(10 to 100) Hz
(100 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.2 % + 0.2 µA
0.47 % + 0.5 µA
0.2 % + 0.3 µA
0.47 % + 0.8 µA
0.065 % + 4 µA
0.16 % + 10 µA
0.065 % + 40 µA
0.16 % + 0.1 mA
0.12 % + 0.2 mA
0.24 % + 1 mA
0.095 % + 2 mA
0.78 % + 5 mA
0.23 % + 0.003 A
0.64 % + 0.003 A
0.25 % + 0.025 A
0.66 % + 0.027 A
0.24 % + 0.09 A
1 % + 0.1 A
Fluke 5520A
Fluke 5520A + 50
turn coil
Electrical Calibration of
Phase Indicators – Generate
Only
3, 8
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.082 °phase
0.20 °phase
0.39 °phase
1.9 °phase
3.9 °phase
7.8 °phase
Fluke 5520A | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 11 of 16
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Current – Measure
3, 8
(10 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 1000) A
(10 to 20) Hz
(20 to 40) Hz
(40 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(45 to 65) Hz
0.46 % + 0.03 µA
0.18 % + 0.03 µA
0.074 % + 0.03 µA
0.074 % + 0.03 µA
0.46 % + 0.2 µA
0.18 % + 0.2 µA
0.076 % + 0.2 µA
0.047 % + 0.2 µA
0.074 % + 0.2 µA
0.46 % + 2 µA
0.18 % + 2 µA
0.077 % + 2 µA
0.048 % + 2 µA
0.075 % + 2 µA
0.46 % + 20 µA
0.18 % + 20 µA
0.077 % + 20 µA
0.049 % + 20 µA
0.075 % + 20 µA
0.47 % + 200 µA
0.2 % + 200 µA
0.12 % + 200 µA
0.14 % + 200 µA
0.35 % + 200 µA
0.15 %
Agilent 3458A
Empro current shunts
& Agilent 3458A | 10 to 1000 A |
| 12 | ASTM Class 7 | - | See scope document |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 13 of 16
Parameter/Equipment
Range
CMC2, 6, 10 (±)
Comments
Pneumatic Pressure – Measure
&/or Measuring Equipment
Calibration of Transfer
Standards & Pressure
Gauges
Absolute
Gauge & Differential
Effective Area
Determination of High
Accuracy Piston-Cylinder
Unit (PCU) or Ball-Nozzle
Units (BNU)
(0 to 15) psia
(15 to 50) psia
(0.14 to 300) psi
(0.14 to 30) psi
0.0028 psia
0.0088 psia
0.0081 %
0.0085 %
Mensor 2300
RK-300/1100WC
Direct cross-float
method– PK DWT,
std. mass
Pressure (Hydraulic) –
Measuring Equipment
Calibration of Transfer
Standards & Pressure
Gauges
(25 to 15 000) psi
0.018 %
Ametek Type T
deadweight tester
Conventional Mass –
(10 to 50) g
(50 to 100) g
(100 to 250) g
(250 to 350) g
(350 to 500) g
(500 to 1000) g
(1000 to 2000) g
(2000 to 5000) g
(5000 to 24 000) g
0.000 068 g
0.000 080 g
0.000 16 g
0.000 60 g
0.000 68 g
0.000 85 g
0.0063 g
0.0070 g
0.058 g
Single substitution
method | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 14 of 16
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Balances & Scales
3, 8
(10 to 50) g
(50 to 100) g
(100 to 150) g
(150 to 350) g
(350 to 500) g
(500 to 1100) g
(1100 to 3000) g
(3000 to 6000) g
(6000 to 12 000) g
(12 000 to 30 000) g
(50 to 100) lb
(100 to 200) lb
(200 to 500) lb
0.000 036 g
0.000 055 g
0.000 064 g
0.000 16 g
0.000 37 g
0.000 63 g
0.0026 g
0.0058 g
0.0062 g
0.013 g
0.011 lb
0.013 lb
0.020 lb
Class 1 weights
Class F weights
IV. Thermodynamics
Parameter/Equipment
Range
CMC
2, 10 (±)
Comments
Temperature – Measure
(-38 to 0) °C
(0 to 156) °C
(156 to 420) °C
(420 to 660) °C
0.019 °C
0.023 °C
0.052 °C
0.099 °C
PRT, readout
Temperature – Measuring
Equipment
(-25 to 0) °C
(0 to 156) °C
(156 to 250) °C
0.013 °C
0.019 °C
0.051 °C
PRT, readout, bath
V. Time & Frequency
Parameter/Equipment
Range
CMC
2, 10 (±)
Comments
Frequency – Measuring
Equipment
3,8
10 MHz
0.01 Hz to 2 MHz
4.0 parts in 10
11
29 μHz/Hz
GPS reference,
rubidium standard
Fluke 5520A | ||
| 15 | NIST SP 960-12 | - | See scope document |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.02) 11/18/2024 Page 16 of 16
7 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
inches
8 This Laboratory also has a Mobile Laboratory that can perform field calibrations for the noted calibrations.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 17 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
4 other sites in this organization
Labs with overlapping accredited scope in United States
- Cal-TecBroussard, LA · ~138 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - BOSSIER CITYBossier City, LA · ~181 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - JACKSONJackson, MS · ~240 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - HARAHANHarahan, LA · ~263 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - HOUSTONHouston, TX · ~329 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.