JM Test Systems, LLC.

1600 Watterberg Way, 71303, Alexandria, LA, United States

Visit website
A2LA 1995.02ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
17
A2LA certificate
1
Sites in our directory
5
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 1995.02 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 10 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 2 of 16 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments DC Voltage – Generate 3, 8 Up to 330 mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 17 µV/V + 1 µV 9.9 µV/V + 2 µV 11 µV/V + 20 µV 15 µV/V + 0.15 mV 15 µV/V + 1.5 mV Fluke 5520A DC Voltage – Measure 3, 8 (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) kV 11 µV/V + 0.3 µV 10 µV/V + 0.3 µV 10 µV/V + 0.5 µV 13 µV/V + 30 µV 14 µV/V + 100 µV 0.23 % Agilent 3458A Fluke 80E10, DMM DC Current – Generate 3, 8 Current Clamps 3, 8 (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 0.012 % + 0.02 µA 0.0079 % + 0.05 µA 0.0081 % + 0.25 µA 0.0084 % + 2.5 µA 0.018 % + 40 µA 0.031 % + 40 µA 0.043 % + 0.5 mA 0.08 % + 0.75 mA 0.19 % + 0.002 A 0.20 % + 0.015 A 0.21 % + 0.05 A Fluke 5520A Fluke 5520A + 50 turn coil DC Current – Measure 3, 8 (10 to 100) μA (0.10 to 1.0) mA (1.0 to 10) mA (10 to 100) mA (0.10 to 1) A (1 to 1000) A 35 µA/A + 0.8 nA 35 µA/A + 5 nA 40 µA/A + 50 nA 53 µA/A + 0.5 µA 0.018 % + 10 µA 0.12 % Agilent 3458A Empro shunts & Agilent 3458A
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 3 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments DC Power – Generate 3, 8 Up to 109 µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 109) W (109 to 337) W (337 to 990) W (0.99 to 3.06) kW (3.06 to 11.2) kW (11.2 to 20.9) kW 5.5 W to 16.8 kW (16.8 to 153) kW (153 to 1045) kW 0.018 % 0.010 % 0.0091 % 0.0089 % 0.0089 % 0.0090 % 0.0090 % 0.0093 % 0.022 % 0.032 % 0.048 % 0.084 % 0.19 % 0.20 % 0.21 % Fluke 5520A Fluke 5520A + 50 turn coil Resistance – Generate, Fixed Points 3, 8 for Insulation Testers 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 0.012 MΩ 0.12 MΩ 1.2 MΩ 0.012 GΩ 0.24 GΩ 5.8 GΩ Fixed resistors Resistance – Generate3, 8 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 33) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 40 µΩ/Ω + 0.001 Ω 29 µΩ/Ω + 0.0015 Ω 29 µΩ/Ω + 0.0014 Ω 35 µΩ/Ω + 0.002 Ω 28 µΩ/Ω + 0.002 Ω 25 µΩ/Ω + 0.02 Ω 25 µΩ/Ω + 0.02 Ω 25 µΩ/Ω + 0.2 Ω 24 µΩ/Ω + 0.2 Ω 33 µΩ/Ω + 2 Ω 32 µΩ/Ω + 2 Ω 53 µΩ/Ω + 30 Ω 0.012 % + 50 Ω 0.022 % + 2.5 kΩ 0.049 % + 3 kΩ 0.29 % + 0.1 MΩ 1.3 % + 0.5 MΩ Fluke 5520A
to 1045 kW
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 4 of 16 Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments Resistance– Measure 3, 8 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (0 to 100) MΩ 10 MΩ to 1 GΩ (1 to 10) GΩ (10 to 100) GΩ 21 µΩ/Ω + 50 µΩ 18 µΩ/Ω + 0.5 mΩ 17 µΩ/Ω + 0.5 mΩ 16 µΩ/Ω + 5 mΩ 19 µΩ/Ω + 50 mΩ 24 µΩ/Ω + 2 Ω 70 µΩ/Ω + 100 Ω 0.06 % + 1 kΩ 77 μΩ/Ω 0.54 % 0.70 % Agilent 3458A Voltage source & µA range of 3458A Capacitance – Generate 3, 8 (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.49 % + 0.01 nF 0.4 % + 0.01 nF 0.41 % + 0.01 nF 0.23 % + 0.01 nF 0.2 % + 0.1 nF 0.2 % + 0.1 nF 0.2 % + 0.3 nF 0.21 % + 1 nF 0.22 % + 3 nF 0.22 % + 10 nF 0.36 % + 30 nF 0.36 % + 0.1 µF 0.36 % + 0.3 µF 0.36 % + 1 µF 0.42 % + 3 µF 0.41 % + 10 µF 0.77 % + 30 µF 0.86 % + 100 µF Fluke 5520A Capacitance – Measure 3, 8 300 pF to 1000 nF (1 to 300) µF (300 to 1100) µF 0.05 % 0.12 % 0.15 % GenRad 1689M RLC Digibridge
0 to 100 GΩ
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 5 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators – Generate & Measure 3, 8 Type E Type J Type K Type N Type R Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.19 °C 0.26 °C 0.15 °C 0.13 °C 0.20 °C 0.31 °C 0.31 °C 0.18 °C 0.16 °C 0.15 °C 0.21 °C 0.44 °C 0.27 °C 0.26 °C 0.31 °C 0.36 °C 0.28 °C 0.29 °C 0.36 °C 0.49 °C 0.20 °C 0.13 °C 0.12 °C Fluke 5520A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 6 of 16 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Electrical Calibration of RTD Indicators – Generate 3, 8 Pt 385, 100 W (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.04 °C 0.04 °C 0.04 °C 0.07 °C 0.08 °C 0.09 °C 0.19 °C Fluke 5520A Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Generate 3, 8 (1.0 to 33) mV (33 to 330) mV (0.33 to 3.3) V (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 3.9 % + 170 µV 0.063 % + 6 µV 0.015 % + 6 µV 0.019 % + 6 µV 0.079 % + 6 µV 0.27 % + 12 µV 0.62 % + 50 µV 3.9 % + 1700 µV 0.025 % + 8 µV 0.012 % + 8 µV 0.013 % + 8 µV 0.028 % + 8 µV 0.063 % + 32 µV 0.16 % + 70 µV 3.9 % + 17 000 µV 0.024 % + 50 µV 0.012 % + 60 µV 0.015 % + 60 µV 0.024 % + 50 µV 0.055 % + 0.13 mV 0.19 % + 0.6 mV Fluke 5520A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 7 of 16 Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments AC Voltage – Generate 3, 8 (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 3.9 % + 170 mV 0.024 % + 0.65 mV 0.012 % + 0.6 mV 0.019 % + 0.6 mV 0.028 % + 0.6 mV 0.071 % + 1.6 mV 0.016 % + 2 mV 0.016 % + 6 mV 0.02 % + 6 mV 0.029 % + 6 mV 0.16 % + 50 mV 0.026 % + 10 mV 0.02 % + 10 mV 0.024 % + 10 mV Fluke 5520A AC Voltage – Measure 3, 8 (0 to 10) mV (10 to 100) mV (0.10 to 1.0) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.051 % + 3 µV 0.056 % + 1.1 µV 0.083 % + 1.1 µV 0.46 % + 1.1 µV 0.78 % + 1.1 µV 4.7 % + 2 µV 0.013 % + 4 µV 0.016 % + 2 µV 0.027 % + 2 µV 0.12 % + 2 µV 0.23 % + 2 µV 0.41 % + 10 µV 1.2 % + 10 µV 0.011 % + 40 µV 0.016 % + 20 µV 0.024 % + 20 µV 0.041 % + 20 µV 0.11 % + 20 µV 0.36 % + 100 µV 1.2 % + 100 µV Agilent 3458A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 8 of 16 Parameter/Range Frequency CMC 2, 4, 5, 6 (±) Comments AC Voltage – Measure3, 8 (cont) (1 to 10) V (10 to 100) V (100 to 750) V (0.75 to 10) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 0.029 % + 0.4 mV 0.012 % + 0.2 mV 0.02 % + 0.2 mV 0.037 % + 0.2 mV 0.095 % + 0.2 mV 0.36 % + 1 mV 1.2 % + 1 mV 0.025 % + 4 mV 0.025 % + 2 mV 0.026 % + 2 mV 0.048 % + 2 mV 0.15 % + 2 mV 0.47 % + 10 mV 1.7 % + 10 mV 0.048 % + 40 mV 0.048 % + 20 mV 0.07 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV 0.23 % Agilent 3458A Fluke 80E10, DMM AC Current – Generate 3, 8 (29 to 330) µA (0.33 to 3.3) mA (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 3.9 % + 1.7 µA 0.16 % + 0.1 µA 0.12 % + 0.1 µA 0.1 % + 0.1 µA 0.24 % + 0.15 µA 0.62 % + 0.2 µA 1.3 % + 0.4 µA 3.9 % + 17 µA 0.16 % + 0.15 µA 0.1 % + 0.15 µA 0.081 % + 0.15 µA 0.16 % + 0.2 µA 0.39 % + 0.3 µA 0.78 % + 0.6 µA Fluke 5520A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 9 of 16 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate 3, 8 (cont) (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 3.9 % + 170 µA 0.15 % + 2 µA 0.072 % + 2 µA 0.036 % + 2 µA 0.065 % + 2 µA 0.16 % + 3 µA 0.31 % + 4 µA 3.9 % + 1700 µA 0.15 % + 20 µA 0.073 % + 20 µA 0.037 % + 20 µA 0.081 % + 50 µA 0.16 % + 0.1 mA 0.31 % + 0.2 mA 0.15 % + 0.1 mA 0.045 % + 0.1 mA 0.052 % + 1 mA 1.9 % + 5 mA 0.15 % + 0.1 mA 0.051 % + 0.1 mA 0.47 % + 1 mA 1.9 % + 5 mA 0.06 % + 2 mA 0.086 % + 2 mA 2.3 % + 2 mA 0.098 % + 5 mA 0.12 % + 5 mA 2.3 % + 5 mA Fluke 5520A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 10 of 16 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate 3, 8 (cont) LCOMP On Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20.5) A Current Clamps 3, 8 (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz (100 to 440) Hz (10 to 100) Hz (100 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.2 % + 0.2 µA 0.47 % + 0.5 µA 0.2 % + 0.3 µA 0.47 % + 0.8 µA 0.065 % + 4 µA 0.16 % + 10 µA 0.065 % + 40 µA 0.16 % + 0.1 mA 0.12 % + 0.2 mA 0.24 % + 1 mA 0.095 % + 2 mA 0.78 % + 5 mA 0.23 % + 0.003 A 0.64 % + 0.003 A 0.25 % + 0.025 A 0.66 % + 0.027 A 0.24 % + 0.09 A 1 % + 0.1 A Fluke 5520A Fluke 5520A + 50 turn coil Electrical Calibration of Phase Indicators – Generate Only 3, 8 (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.082 °phase 0.20 °phase 0.39 °phase 1.9 °phase 3.9 °phase 7.8 °phase Fluke 5520A
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 11 of 16 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Current – Measure 3, 8 (10 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 1000) A (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (45 to 65) Hz 0.46 % + 0.03 µA 0.18 % + 0.03 µA 0.074 % + 0.03 µA 0.074 % + 0.03 µA 0.46 % + 0.2 µA 0.18 % + 0.2 µA 0.076 % + 0.2 µA 0.047 % + 0.2 µA 0.074 % + 0.2 µA 0.46 % + 2 µA 0.18 % + 2 µA 0.077 % + 2 µA 0.048 % + 2 µA 0.075 % + 2 µA 0.46 % + 20 µA 0.18 % + 20 µA 0.077 % + 20 µA 0.049 % + 20 µA 0.075 % + 20 µA 0.47 % + 200 µA 0.2 % + 200 µA 0.12 % + 200 µA 0.14 % + 200 µA 0.35 % + 200 µA 0.15 % Agilent 3458A Empro current shunts & Agilent 3458A
10 to 1000 A
12ASTM Class 7-See scope document
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 13 of 16 Parameter/Equipment Range CMC2, 6, 10 (±) Comments Pneumatic Pressure – Measure &/or Measuring Equipment Calibration of Transfer Standards & Pressure Gauges Absolute Gauge & Differential Effective Area Determination of High Accuracy Piston-Cylinder Unit (PCU) or Ball-Nozzle Units (BNU) (0 to 15) psia (15 to 50) psia (0.14 to 300) psi (0.14 to 30) psi 0.0028 psia 0.0088 psia 0.0081 % 0.0085 % Mensor 2300 RK-300/1100WC Direct cross-float method– PK DWT, std. mass Pressure (Hydraulic) – Measuring Equipment Calibration of Transfer Standards & Pressure Gauges (25 to 15 000) psi 0.018 % Ametek Type T deadweight tester Conventional Mass – (10 to 50) g (50 to 100) g (100 to 250) g (250 to 350) g (350 to 500) g (500 to 1000) g (1000 to 2000) g (2000 to 5000) g (5000 to 24 000) g 0.000 068 g 0.000 080 g 0.000 16 g 0.000 60 g 0.000 68 g 0.000 85 g 0.0063 g 0.0070 g 0.058 g Single substitution method
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 14 of 16 Parameter/Equipment Range CMC2, 6 (±) Comments Balances & Scales 3, 8 (10 to 50) g (50 to 100) g (100 to 150) g (150 to 350) g (350 to 500) g (500 to 1100) g (1100 to 3000) g (3000 to 6000) g (6000 to 12 000) g (12 000 to 30 000) g (50 to 100) lb (100 to 200) lb (200 to 500) lb 0.000 036 g 0.000 055 g 0.000 064 g 0.000 16 g 0.000 37 g 0.000 63 g 0.0026 g 0.0058 g 0.0062 g 0.013 g 0.011 lb 0.013 lb 0.020 lb Class 1 weights Class F weights IV. Thermodynamics Parameter/Equipment Range CMC 2, 10 (±) Comments Temperature – Measure (-38 to 0) °C (0 to 156) °C (156 to 420) °C (420 to 660) °C 0.019 °C 0.023 °C 0.052 °C 0.099 °C PRT, readout Temperature – Measuring Equipment (-25 to 0) °C (0 to 156) °C (156 to 250) °C 0.013 °C 0.019 °C 0.051 °C PRT, readout, bath V. Time & Frequency Parameter/Equipment Range CMC 2, 10 (±) Comments Frequency – Measuring Equipment 3,8 10 MHz 0.01 Hz to 2 MHz 4.0 parts in 10 11 29 μHz/Hz GPS reference, rubidium standard Fluke 5520A
15NIST SP 960-12-See scope document
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.02) 11/18/2024 Page 16 of 16 7 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches 8 This Laboratory also has a Mobile Laboratory that can perform field calibrations for the noted calibrations. 9 This scope meets A2LA’s P112 Flexible Scope Policy. 10 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
17ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1600 Watterberg Way, Alexandria, LA, 71303, US

31.31195, -92.44536

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.