What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 1995.05 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 4 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 2 of 14
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage
3 – Generate
(0 to 330) mV
(0.33 to 33) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
17 µV/V + 1 µV
9.9 µV/V + 2 µV
11 µV/V + 20 µV
15 µV/V + 0.15 mV
15 µV/V + 1.5 mV
Fluke 5520A
DC Current
3 – Generate
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
0.012 % + 0.02 µA
0.0079 % + 0.05 µA
0.0081 % + 0.25 µA
0.0084 % + 2.5 µA
0.018 % + 40 µA
0.031 % + 40 µA
0.043 % + 0.5 mA
0.08 % + 0.75 mA
0.19 % + 0.002 A
0.2 % + 0.015 A
0.21 % + 0.05 A
Fluke 5520A
Fluke 5520A, 50
turn coil
Resistance3– Generate
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 33) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
40 µΩ/Ω + 0.001 Ω
29 µΩ/Ω + 0.0015 Ω
29 µΩ/Ω + 0.0014 Ω
35 µΩ/Ω + 0.002 Ω
28 µΩ/Ω + 0.002 Ω
25 µΩ/Ω + 0.02 Ω
25 µΩ/Ω + 0.02 Ω
25 µΩ/Ω + 0.2 Ω
24 µΩ/Ω + 0.2 Ω
33 µΩ/Ω + 2 Ω
32 µΩ/Ω + 2 Ω
53 µΩ/Ω + 30 Ω
0.012 % + 50 Ω
0.022 % + 2.5 kΩ
0.049 % + 3 kΩ
0.29 % + 0.1 MΩ
1.3 % + 0.5 MΩ
Fluke 5520A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 3 of 14
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Resistance
3– Generate
(cont)
Fixed Points for
Insulation Testers
3
Fixed Points for Ground
Testers & Low
Resistance Ohmmeters
3
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
0.1 mΩ
0.5 mΩ
1 mΩ
2 mΩ
5 mΩ
10 mΩ
20 mΩ
50 mΩ
0.1 Ω
0.2 Ω
0.5 Ω
1 Ω
0.012 MΩ
0.12 MΩ
1.2 MΩ
0.012 GΩ
0.24 GΩ
5.8 GΩ
0.39 µΩ
1.6 µΩ
3.2 µΩ
6.3 µΩ
15 µΩ
29 µΩ
28 µΩ
66 µΩ
0.12 mΩ
0.25 mΩ
0.60 mΩ
1.2 mΩ
Fixed resistors
Current shunts
DC Power3 – Generate
Up to 109 µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 109) W
(109 to 337) W
(337 to 990) W
(0.99 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
5.5 W to 16.8 kW
(16.8 to 153) kW
(153 to 1045) kW
0.023 %
0.014 %
0.013 %
0.013 %
0.013 %
0.013 %
0.013 %
0.013 %
0.027 %
0.045 %
0.064 %
0.12 %
0.19 %
0.20 %
0.21 %
Fluke 5520A
Fluke 5520A + 50
turn coil | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 4 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage
3 – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
3.9 % + 170 µV
0.063 % + 6 µV
0.015 % + 6 µV
0.019 % + 6 µV
0.079 % + 6 µV
0.27 % + 12 µV
0.62 % + 50 µV
3.9 % + 1700 µV
0.025 % + 8 µV
0.012 % + 8 µV
0.013 % + 8 µV
0.028 % + 8 µV
0.063 % + 32 µV
0.16 % + 70 µV
3.9 % + 17 000 µV
0.024 % + 50 µV
0.012 % + 60 µV
0.015 % + 60 µV
0.024 % + 50 µV
0.055 % + 0.13 mV
0.19 % + 0.6 mV
3.9 % + 170 mV
0.024 % + 0.65 mV
0.012 % + 0.6 mV
0.019 % + 0.6 mV
0.028 % + 0.6 mV
0.071 % + 1.6 mV
0.016 % + 2 mV
0.016 % + 6 mV
0.02 % + 6 mV
0.029 % + 6 mV
0.16 % + 50 mV
0.026 % + 10 mV
0.020 % + 10 mV
0.024 % + 10 mV
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 5 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3– Generate
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(0.01 to 10) Hz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
3.9 % + 1.7 µA
0.16 % + 0.1 µA
0.12 % + 0.1 µA
0.1 % + 0.1 µA
0.24 % + 0.15 µA
0.62 % + 0.2 µA
1.3 % + 0.4 µA
3.9 % + 17 µA
0.16 % + 0.15 µA
0.1 % + 0.15 µA
0.081 % + 0.15 µA
0.16 % + 0.2 µA
0.39 % + 0.3 µA
0.78 % + 0.6 µA
3.9 % + 170 µA
0.15 % + 2 µA
0.072 % + 2 µA
0.036 % + 2 µA
0.065 % + 2 µA
0.16 % + 3 µA
0.31 % + 4 µA
3.9 % + 1700 µA
0.15 % + 20 µA
0.073 % + 20 µA
0.037 % + 20 µA
0.081 % + 50 µA
0.16 % + 0.1 mA
0.31 % + 0.2 mA
0.15 % + 0.1 mA
0.045 % + 0.1 mA
0.052 % + 1 mA
1.9 % + 5 mA
0.15 % + 0.1 mA
0.051 % + 0.1 mA
0.47 % + 1 mA
1.9 % + 5 mA
0.06 % + 2 mA
0.086 % + 2 mA
2.3 % + 2 mA
Fluke 5520A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 6 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3 – Generate
(cont)
(11 to 20.5) A
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3) A
(3 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
(100 to 440) Hz
(10 to 100) Hz
(100 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.098 % + 5 mA
0.12 % + 5 mA
2.3 % + 5 mA
0.2 % + 0.2 µA
0.47 % + 0.5 µA
0.2 % + 0.3 µA
0.47 % + 0.8 µA
0.065 % + 4 µA
0.16 % + 10 µA
0.065 % + 40 µA
0.16 % + 0.1 mA
0.12 % + 0.2 mA
0.24 % + 1 mA
0.095 % + 2 mA
0.78 % + 5 mA
0.23 % + 0.003 A
0.64 % + 0.003 A
0.25 % + 0.025 A
0.66 % + 0.027 A
0.24 % + 0.09 A
1 % + 0.1 A
Fluke 5520A
Fluke 5520A with
LCOMP On
Fluke 5520A, 50
turn coil | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 7 of 14
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
AC Power
3 – Generate
(45 to 65 Hz, PF=1)
Up to 10.9 µW
(10.9 to 109 µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 37) W
(37 to 337) W
(0.337 to 1.12) kW
(1.12 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
0.55 W to 16.8 kW
(16.8 to 1045) kW
0.13 %
0.09 %
0.05 %
0.044 %
0.044 %
0.044 %
0.045 %
0.047 %
0.051 %
0.057 %
0.061 %
0.08 %
0.13 %
0.23 %
0.25 %
Fluke 5520A
Fluke 5520A, 50
turn coil
Capacitance3 – Generate
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.49 % + 0.01 nF
0.40 % + 0.01 nF
0.41 % + 0.01 nF
0.23 % + 0.01 nF
0.20 % + 0.1 nF
0.20 % + 0.1 nF
0.20 % + 0.3 nF
0.21 % + 1 nF
0.22 % + 3 nF
0.22 % + 10 nF
0.36 % + 30 nF
0.36 % + 0.1 µF
0.36 % + 0.3 µF
0.36 % + 1 µF
0.42 % + 3 µF
0.41 % + 10 µF
0.77 % + 30 µF
0.86 % + 100 µF
Fluke 5520A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 8 of 14
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration of
Thermocouple Indicators
3
– Generate & Measure
Type E
Type J
Type K
Type N
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.12 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.20 °C
0.31 °C
0.31 °C
0.18 °C
0.16 °C
0.15 °C
0.21 °C
0.49 °C
0.20 °C
0.13 °C
0.12 °C
Fluke 5520A
Electrical Calibration of
RTD Indicators
3 –
Generate
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.04 °C
0.04 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.19 °C
Fluke 5520A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 9 of 14
Parameter/Equipment
Range
CMC2, 4, 5, 6 (±)
Comments
Electrical Calibration of
Phase Indicators
3 –
Generate
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.082 °phase
0.20 °phase
0.39 °phase
1.9 °phase
3.9 °phase
7.8 °phase
Fluke 5520A
DC Voltage3 – Measure
(0 to 100) mV
(0.10 to 1.0) V
(1.0 to 10) V
(10 to 100) V
(100 to 1000) V
11 µV/V + 0.3 µV
10 µV/V + 0.3 µV
10 µV/V + 0.5 µV
13 µV/V + 30 µV
14 µV/V + 100 µV
Keysight 3458A
DC High Voltage3 –
Generate & Measure
(1 to 100) kV
1.2 %
Phenix KVM-
(series)
Resistance3 – Measure
Up to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
10 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 100) GΩ
21 µΩ/Ω + 50 µΩ
18 µΩ/Ω + 0.5 mΩ
17 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 5 mΩ
19 µΩ/Ω + 50 mΩ
24 µΩ/Ω + 2 Ω
70 µΩ/Ω + 100 Ω
0.060 % + 1 kΩ
77 μΩ/Ω
0.54 %
0.70 %
Keysight 3458A
Voltage source &
µA range of 3458A
DC Current
3 – Measure
Up to 100 µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 50) A
(50 to 200) A
(200 to 1000) A
35 µA/A + 0.8 nA
35 µA/A + 5 nA
40 µA/A + 50 nA
53 µA/A + 0.5 µA
0.018 % + 10 µA
0.12 %
0.14 %
0.32 %
0.39 %
Keysight 3458A
Current shunts,
DMM | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 10 of 14
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(10 to 40) Hz
40 Hz to 1 kHz
(1to20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.051 % + 3 µV
0.056 % + 1.1 µV
0.083 % + 1.1 µV
0.46 % + 1.1 µV
0.77 % + 1.1 µV
4.7 % + 2 µV
0.013 % + 4 µV
0.016 % + 2 µV
0.027 % + 2 µV
0.12 % + 2 µV
0.23 % + 2 µV
0.41 % + 10 µV
1.2 % + 10 µV
0.011 % + 40 µV
0.016 % + 20 µV
0.024 % + 20 µV
0.041 % + 20 µV
0.11 % + 20 µV
0.36 % + 100 µV
1.2 % + 100 µV
0.029 % + 0.4 mV
0.012 % + 0.2 mV
0.020 % + 0.2 mV
0.037 % + 0.2 mV
0.095 % + 0.2 mV
0.36 % + 1 mV
1.2 % + 1 mV
0.025 % + 4 mV
0.025 % + 2 mV
0.027 % + 2 mV
0.048 % + 2 mV
0.15 % + 2 mV
0.47 % + 10 mV
1.8 % + 10 mV
Keysight 3458A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 11 of 14
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage3 – Measure
(cont)
(100 to 700) V
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.048 % + 40 mV
0.048 % + 20 mV
0.070 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
Keysight 3458A
AC High Voltage –
Generate & Measure3
(0.7 to 6) kV
(6 to 80 kV)
(DC to 500) Hz
60 Hz
1.5 %
1.6 %
Fluke 80K-6, DMM
Phenix KVM-
(series)
AC Current3 – Measure
Up to 100 μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
0.46 % + 0.03 µA
0.18 % + 0.03 µA
0.074 % + 0.03 µA
0.074 % + 0.03 µA
0.46 % + 0.2 µA
0.18 % + 0.2 µA
0.076 % + 0.2 µA
0.047 % + 0.2 µA
0.074 % + 0.2 µA
0.46 % + 2 µA
0.18 % + 2 µA
0.077 % + 2 µA
0.048 % + 2 µA
0.075 % + 2 µA
0.46 % + 20 µA
0.18 % + 20 µA
0.077 % + 20 µA
0.049 % + 20 µA
0.075 % + 20 µA
0.47 % + 200 µA
0.20 % + 200 µA
0.11 % + 200 µA
0.13 % + 200 µA
0.35 % + 200 µA
Agilent 3458A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 12 of 14
Parameter/Range
Frequency
CMC2, 6, 9 (±)
Comments
AC Current3 – Measure
(cont)
(1 to 10) A
(10 to 50) A
(50 to 200) A
(200 to 1000) A
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
0.12 %
0.14 %
0.32 %
0.39 %
Current shunts,
DMM
III. Mechanical
Parameter/Equipment
Range
CMC
2, 6, 9 (±)
Comments
Torque Devices (Wrenches,
Drivers, Screwdrivers)
3
5 lbfꞏin to 2000 lbfꞏft
0.94 %
CDI & AWS torque
testers
Pressure (Pneumatic) –
Measuring Equipment
Calibration of Transfer
Standards & Pressure
Gauges:
Absolute
Gauge & Differential
(0 to 15) psia
(15 to 50) psia
(0.14 to 300) psi
0.0035 psia
0.015 psia
0.0081 %
Mensor 2300
RK-300/1100WC
Pressure (Hydraulic) –
Measuring Equipment
Calibration of Transfer
Standards & Pressure
Gauges
(25 to 15 000) psi
0.018 %
Ametek Type T
series deadweight
tester | ||
| 13 | NIST SP 960-12 | - | See scope document |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.05) 12/04/2025 Page 14 of 14
3 Field calibration service is available for th ese calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the actual uncerta inty introduced by the item being calibrated, (e.g.
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC. Field environmental conditions
are limited to 15 °C to 30 °C and <80% relative humidity to 30 °C.
4 Fluke 5520A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and assuming
the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5
oC. For Resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. For AC
Current, CMCs are determined with the LCOMP off and ON. CMCs are also based upon 1-year floor
specifications. CMCs are expressed as either a specifi c value that covers the full range or as a fraction
of the reading plus a fixed floor specification.
5 Agilent 3458A CMCs are based upon the temper ature the standard was calibrated (tcal ± 5 oC) and an
auto calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature.)
CMCs are also based upon 1-year floor specifications . CMCs are expressed as either a specific value
that covers the full range or as a combination of a percent or the fraction of the reading/output plus a
range specification.
6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
7 Applicable when the internal time base (oscillator) of the device under test is/can be measured directly by
the frequency counter.
8 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
9 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
10 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
4 other sites in this organization
Labs with overlapping accredited scope in United States
- G.T. MICHELLI CO., LLC - HOUSTONHouston, TX · ~139 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technology & Calibration, Inc. dba Tech CalHouston, TX · ~139 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cal-TecBroussard, LA · ~192 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - BOSSIER CITYBossier City, LA · ~295 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - HARAHANHarahan, LA · ~360 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.