JM Test Systems, LLC.

3848 Hwy 73, 77642, Port Arthur, TX, United States

Visit website
A2LA 1995.05ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
15
A2LA certificate
1
Sites in our directory
5
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 1995.05 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 4 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 2 of 14 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage 3 – Generate (0 to 330) mV (0.33 to 33) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 17 µV/V + 1 µV 9.9 µV/V + 2 µV 11 µV/V + 20 µV 15 µV/V + 0.15 mV 15 µV/V + 1.5 mV Fluke 5520A DC Current 3 – Generate Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 0.012 % + 0.02 µA 0.0079 % + 0.05 µA 0.0081 % + 0.25 µA 0.0084 % + 2.5 µA 0.018 % + 40 µA 0.031 % + 40 µA 0.043 % + 0.5 mA 0.08 % + 0.75 mA 0.19 % + 0.002 A 0.2 % + 0.015 A 0.21 % + 0.05 A Fluke 5520A Fluke 5520A, 50 turn coil Resistance3– Generate Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 33) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 40 µΩ/Ω + 0.001 Ω 29 µΩ/Ω + 0.0015 Ω 29 µΩ/Ω + 0.0014 Ω 35 µΩ/Ω + 0.002 Ω 28 µΩ/Ω + 0.002 Ω 25 µΩ/Ω + 0.02 Ω 25 µΩ/Ω + 0.02 Ω 25 µΩ/Ω + 0.2 Ω 24 µΩ/Ω + 0.2 Ω 33 µΩ/Ω + 2 Ω 32 µΩ/Ω + 2 Ω 53 µΩ/Ω + 30 Ω 0.012 % + 50 Ω 0.022 % + 2.5 kΩ 0.049 % + 3 kΩ 0.29 % + 0.1 MΩ 1.3 % + 0.5 MΩ Fluke 5520A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 3 of 14 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Resistance 3– Generate (cont) Fixed Points for Insulation Testers 3 Fixed Points for Ground Testers & Low Resistance Ohmmeters 3 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 0.1 mΩ 0.5 mΩ 1 mΩ 2 mΩ 5 mΩ 10 mΩ 20 mΩ 50 mΩ 0.1 Ω 0.2 Ω 0.5 Ω 1 Ω 0.012 MΩ 0.12 MΩ 1.2 MΩ 0.012 GΩ 0.24 GΩ 5.8 GΩ 0.39 µΩ 1.6 µΩ 3.2 µΩ 6.3 µΩ 15 µΩ 29 µΩ 28 µΩ 66 µΩ 0.12 mΩ 0.25 mΩ 0.60 mΩ 1.2 mΩ Fixed resistors Current shunts DC Power3 – Generate Up to 109 µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 109) W (109 to 337) W (337 to 990) W (0.99 to 3.06) kW (3.06 to 11.2) kW (11.2 to 20.9) kW 5.5 W to 16.8 kW (16.8 to 153) kW (153 to 1045) kW 0.023 % 0.014 % 0.013 % 0.013 % 0.013 % 0.013 % 0.013 % 0.013 % 0.027 % 0.045 % 0.064 % 0.12 % 0.19 % 0.20 % 0.21 % Fluke 5520A Fluke 5520A + 50 turn coil
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 4 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage 3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 3.9 % + 170 µV 0.063 % + 6 µV 0.015 % + 6 µV 0.019 % + 6 µV 0.079 % + 6 µV 0.27 % + 12 µV 0.62 % + 50 µV 3.9 % + 1700 µV 0.025 % + 8 µV 0.012 % + 8 µV 0.013 % + 8 µV 0.028 % + 8 µV 0.063 % + 32 µV 0.16 % + 70 µV 3.9 % + 17 000 µV 0.024 % + 50 µV 0.012 % + 60 µV 0.015 % + 60 µV 0.024 % + 50 µV 0.055 % + 0.13 mV 0.19 % + 0.6 mV 3.9 % + 170 mV 0.024 % + 0.65 mV 0.012 % + 0.6 mV 0.019 % + 0.6 mV 0.028 % + 0.6 mV 0.071 % + 1.6 mV 0.016 % + 2 mV 0.016 % + 6 mV 0.02 % + 6 mV 0.029 % + 6 mV 0.16 % + 50 mV 0.026 % + 10 mV 0.020 % + 10 mV 0.024 % + 10 mV Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 5 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3– Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (0.01 to 10) Hz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 3.9 % + 1.7 µA 0.16 % + 0.1 µA 0.12 % + 0.1 µA 0.1 % + 0.1 µA 0.24 % + 0.15 µA 0.62 % + 0.2 µA 1.3 % + 0.4 µA 3.9 % + 17 µA 0.16 % + 0.15 µA 0.1 % + 0.15 µA 0.081 % + 0.15 µA 0.16 % + 0.2 µA 0.39 % + 0.3 µA 0.78 % + 0.6 µA 3.9 % + 170 µA 0.15 % + 2 µA 0.072 % + 2 µA 0.036 % + 2 µA 0.065 % + 2 µA 0.16 % + 3 µA 0.31 % + 4 µA 3.9 % + 1700 µA 0.15 % + 20 µA 0.073 % + 20 µA 0.037 % + 20 µA 0.081 % + 50 µA 0.16 % + 0.1 mA 0.31 % + 0.2 mA 0.15 % + 0.1 mA 0.045 % + 0.1 mA 0.052 % + 1 mA 1.9 % + 5 mA 0.15 % + 0.1 mA 0.051 % + 0.1 mA 0.47 % + 1 mA 1.9 % + 5 mA 0.06 % + 2 mA 0.086 % + 2 mA 2.3 % + 2 mA Fluke 5520A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 6 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Generate (cont) (11 to 20.5) A (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz (100 to 440) Hz (10 to 100) Hz (100 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.098 % + 5 mA 0.12 % + 5 mA 2.3 % + 5 mA 0.2 % + 0.2 µA 0.47 % + 0.5 µA 0.2 % + 0.3 µA 0.47 % + 0.8 µA 0.065 % + 4 µA 0.16 % + 10 µA 0.065 % + 40 µA 0.16 % + 0.1 mA 0.12 % + 0.2 mA 0.24 % + 1 mA 0.095 % + 2 mA 0.78 % + 5 mA 0.23 % + 0.003 A 0.64 % + 0.003 A 0.25 % + 0.025 A 0.66 % + 0.027 A 0.24 % + 0.09 A 1 % + 0.1 A Fluke 5520A Fluke 5520A with LCOMP On Fluke 5520A, 50 turn coil
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 7 of 14 Parameter/Equipment Range CMC2, 4, 6 (±) Comments AC Power 3 – Generate (45 to 65 Hz, PF=1) Up to 10.9 µW (10.9 to 109 µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 37) W (37 to 337) W (0.337 to 1.12) kW (1.12 to 3.06) kW (3.06 to 11.2) kW (11.2 to 20.9) kW 0.55 W to 16.8 kW (16.8 to 1045) kW 0.13 % 0.09 % 0.05 % 0.044 % 0.044 % 0.044 % 0.045 % 0.047 % 0.051 % 0.057 % 0.061 % 0.08 % 0.13 % 0.23 % 0.25 % Fluke 5520A Fluke 5520A, 50 turn coil Capacitance3 – Generate (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.49 % + 0.01 nF 0.40 % + 0.01 nF 0.41 % + 0.01 nF 0.23 % + 0.01 nF 0.20 % + 0.1 nF 0.20 % + 0.1 nF 0.20 % + 0.3 nF 0.21 % + 1 nF 0.22 % + 3 nF 0.22 % + 10 nF 0.36 % + 30 nF 0.36 % + 0.1 µF 0.36 % + 0.3 µF 0.36 % + 1 µF 0.42 % + 3 µF 0.41 % + 10 µF 0.77 % + 30 µF 0.86 % + 100 µF Fluke 5520A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 8 of 14 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Indicators 3 – Generate & Measure Type E Type J Type K Type N Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.19 °C 0.26 °C 0.15 °C 0.13 °C 0.20 °C 0.31 °C 0.31 °C 0.18 °C 0.16 °C 0.15 °C 0.21 °C 0.49 °C 0.20 °C 0.13 °C 0.12 °C Fluke 5520A Electrical Calibration of RTD Indicators 3 – Generate Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.04 °C 0.04 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.19 °C Fluke 5520A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 9 of 14 Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments Electrical Calibration of Phase Indicators 3 – Generate (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.082 °phase 0.20 °phase 0.39 °phase 1.9 °phase 3.9 °phase 7.8 °phase Fluke 5520A DC Voltage3 – Measure (0 to 100) mV (0.10 to 1.0) V (1.0 to 10) V (10 to 100) V (100 to 1000) V 11 µV/V + 0.3 µV 10 µV/V + 0.3 µV 10 µV/V + 0.5 µV 13 µV/V + 30 µV 14 µV/V + 100 µV Keysight 3458A DC High Voltage3 – Generate & Measure (1 to 100) kV 1.2 % Phenix KVM- (series) Resistance3 – Measure Up to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 10 MΩ to 1 GΩ (1 to 10) GΩ (10 to 100) GΩ 21 µΩ/Ω + 50 µΩ 18 µΩ/Ω + 0.5 mΩ 17 µΩ/Ω + 0.5 mΩ 16 µΩ/Ω + 5 mΩ 19 µΩ/Ω + 50 mΩ 24 µΩ/Ω + 2 Ω 70 µΩ/Ω + 100 Ω 0.060 % + 1 kΩ 77 μΩ/Ω 0.54 % 0.70 % Keysight 3458A Voltage source & µA range of 3458A DC Current 3 – Measure Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 50) A (50 to 200) A (200 to 1000) A 35 µA/A + 0.8 nA 35 µA/A + 5 nA 40 µA/A + 50 nA 53 µA/A + 0.5 µA 0.018 % + 10 µA 0.12 % 0.14 % 0.32 % 0.39 % Keysight 3458A Current shunts, DMM
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 10 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 40) Hz 40 Hz to 1 kHz (1to20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.051 % + 3 µV 0.056 % + 1.1 µV 0.083 % + 1.1 µV 0.46 % + 1.1 µV 0.77 % + 1.1 µV 4.7 % + 2 µV 0.013 % + 4 µV 0.016 % + 2 µV 0.027 % + 2 µV 0.12 % + 2 µV 0.23 % + 2 µV 0.41 % + 10 µV 1.2 % + 10 µV 0.011 % + 40 µV 0.016 % + 20 µV 0.024 % + 20 µV 0.041 % + 20 µV 0.11 % + 20 µV 0.36 % + 100 µV 1.2 % + 100 µV 0.029 % + 0.4 mV 0.012 % + 0.2 mV 0.020 % + 0.2 mV 0.037 % + 0.2 mV 0.095 % + 0.2 mV 0.36 % + 1 mV 1.2 % + 1 mV 0.025 % + 4 mV 0.025 % + 2 mV 0.027 % + 2 mV 0.048 % + 2 mV 0.15 % + 2 mV 0.47 % + 10 mV 1.8 % + 10 mV Keysight 3458A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 11 of 14 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage3 – Measure (cont) (100 to 700) V (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.048 % + 40 mV 0.048 % + 20 mV 0.070 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV Keysight 3458A AC High Voltage – Generate & Measure3 (0.7 to 6) kV (6 to 80 kV) (DC to 500) Hz 60 Hz 1.5 % 1.6 % Fluke 80K-6, DMM Phenix KVM- (series) AC Current3 – Measure Up to 100 μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz 0.46 % + 0.03 µA 0.18 % + 0.03 µA 0.074 % + 0.03 µA 0.074 % + 0.03 µA 0.46 % + 0.2 µA 0.18 % + 0.2 µA 0.076 % + 0.2 µA 0.047 % + 0.2 µA 0.074 % + 0.2 µA 0.46 % + 2 µA 0.18 % + 2 µA 0.077 % + 2 µA 0.048 % + 2 µA 0.075 % + 2 µA 0.46 % + 20 µA 0.18 % + 20 µA 0.077 % + 20 µA 0.049 % + 20 µA 0.075 % + 20 µA 0.47 % + 200 µA 0.20 % + 200 µA 0.11 % + 200 µA 0.13 % + 200 µA 0.35 % + 200 µA Agilent 3458A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 12 of 14 Parameter/Range Frequency CMC2, 6, 9 (±) Comments AC Current3 – Measure (cont) (1 to 10) A (10 to 50) A (50 to 200) A (200 to 1000) A (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz 0.12 % 0.14 % 0.32 % 0.39 % Current shunts, DMM III. Mechanical Parameter/Equipment Range CMC 2, 6, 9 (±) Comments Torque Devices (Wrenches, Drivers, Screwdrivers) 3 5 lbfꞏin to 2000 lbfꞏft 0.94 % CDI & AWS torque testers Pressure (Pneumatic) – Measuring Equipment Calibration of Transfer Standards & Pressure Gauges: Absolute Gauge & Differential (0 to 15) psia (15 to 50) psia (0.14 to 300) psi 0.0035 psia 0.015 psia 0.0081 % Mensor 2300 RK-300/1100WC Pressure (Hydraulic) – Measuring Equipment Calibration of Transfer Standards & Pressure Gauges (25 to 15 000) psi 0.018 % Ametek Type T series deadweight tester
13NIST SP 960-12-See scope document
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.05) 12/04/2025 Page 14 of 14 3 Field calibration service is available for th ese calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncerta inty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. Field environmental conditions are limited to 15 °C to 30 °C and <80% relative humidity to 30 °C. 4 Fluke 5520A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 oC. For Resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. For AC Current, CMCs are determined with the LCOMP off and ON. CMCs are also based upon 1-year floor specifications. CMCs are expressed as either a specifi c value that covers the full range or as a fraction of the reading plus a fixed floor specification. 5 Agilent 3458A CMCs are based upon the temper ature the standard was calibrated (tcal ± 5 oC) and an auto calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature.) CMCs are also based upon 1-year floor specifications . CMCs are expressed as either a specific value that covers the full range or as a combination of a percent or the fraction of the reading/output plus a range specification. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. 7 Applicable when the internal time base (oscillator) of the device under test is/can be measured directly by the frequency counter. 8 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 9 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 10 This scope meets A2LA’s P112 Flexible Scope Policy.
15ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.