JM Test Systems, LLC.
1020 N. Texas Ave., 79761, Odessa, TX, United States
Visit website- Scope lines
- 16
- A2LA certificate
- 1
- Sites in our directory
- 5
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 1995.04 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 48 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 2 of 15
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
DC Voltage – Generate
3
(0 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
24 μV/V + 1 μV
13 μV/V + 2 μV
15 μV/V + 20 μV
21 μV/V + 0.15 mV
21 μV/V + 1.5 mV
Fluke 5522A
DC Current – Generate
3
Clamp Meters
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
0.017 % + 0.02 µA
0.012 % + 0.05 µA
0.012 % + 0.25 µA
0.012 % + 2.5 µA
0.023 % + 40 μA
0.044 % + 40 μA
0.059 % + 0.5 mA
0.12 % + 0.75 mA
0.25 % + 0.002 A
0.26 % + 0.015 A
0.28 % + 0.05 A
Fluke 5522A
Fluke 5522A, 50 turn
coil
Resistance – Generate,
Fixed Points3, 8
0.1 mΩ
0.5 mΩ
1 mΩ
2 mΩ
5 mΩ
10 mΩ
20 mΩ
50 mΩ
0.1 Ω
0.2 Ω
0.5 Ω
1 Ω
0.39 µΩ
1.6 µΩ
3.2 µΩ
6.3 µΩ
15 µΩ
29 µΩ
28 µΩ
66 µΩ
0.12 mΩ
0.25 mΩ
0.60 mΩ
1.2 mΩ
Empro shunts | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 3 of 15
Parameter/Equipment
Range
CMC2, 5, 9 (±)
Comments
Resistance – Generate
3
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 33) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
51 μΩ/Ω + 0.001 Ω
35 μΩ/Ω + 0.0015 Ω
33 μΩ/Ω + 0.0014 Ω
33 μΩ/Ω + 0.002 Ω
33 μΩ/Ω + 0.002 Ω
33 μΩ/Ω + 0.02 Ω
33 μΩ/Ω + 0.02 Ω
33 μΩ/Ω + 0.2 Ω
33 μΩ/Ω + 0.2 Ω
37 μΩ/Ω + 2 Ω
38 μΩ/Ω + 2 Ω
70 μΩ/Ω + 30 Ω
0.015 % + 50 Ω
0.029 % + 2.5 kΩ
0.06 % + 3 kΩ
0.35 % + 0.1 MΩ
1.7 % + 0.5 MΩ
Fluke 5522A
Resistance – Generate,
Fixed Points for
Insulation Testers
3
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
0.012 MΩ
0.12 MΩ
1.2 MΩ
0.012 GΩ
0.24 GΩ
5.8 GΩ
Fixed resistors
DC Power – Generate
3
Up to 109 µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 109) W
(109 to 337) W
(337 to 990) W
(0.99 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
5.5 W to 16.8 kW
(16.8 to 153) kW
(153 to 1045) kW
0.023 %
0.014 %
0.013 %
0.013 %
0.013 %
0.013 %
0.013 %
0.013 %
0.027 %
0.045 %
0.064 %
0.12 %
0.19 %
0.20 %
0.21 %
Fluke 5522A
Fluke 5520A + 50 turn
coil | to 1100 MΩ |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 4 of 15
Parameter/Range
Frequency
CMC2, 9 (±)
Comments
AC Voltage – Generate
3
Up to 33 mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.095 % + 6 μV
0.019 % + 6 μV
0.024 % + 6 μV
0.12 % + 6 μV
0.4 % + 12 μV
0.93 % + 50 μV
0.035 % + 8 μV
0.017 % + 8 μV
0.019 % + 8 μV
0.041 % + 8 μV
0.093 % + 32 μV
0.23 % + 70 μV
0.035 % + 50 μV
0.017 % + 60 μV
0.022 % + 60 μV
0.035 % + 50 μV
0.081 % + 0.13 mV
0.28 % + 0.6 mV
0.035 % + 0.65 mV
0.017 % + 0.6 mV
0.028 % + 0.6 mV
0.04 % + 0.6 mV
0.1 % + 1.6 mV
0.022 % + 2 mV
0.023 % + 6 mV
0.029 % + 6 mV
0.035 % + 6 mV
0.23 % + 50 mV
0.035 % + 10 mV
0.029 % + 10 mV
0.035 % + 10 mV
Fluke 5522A | to 1020 V |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 5 of 15
Parameter/Range
Frequency
CMC2,, 9 (±)
Comments
AC Current – Generate
3
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.23 % + 0.1 µA
0.17 % + 0.1 µA
0.14 % + 0.1 µA
0.35 % + 0.15 µA
0.92 % + 0.2 µA
1.8 % + 0.4 µA
0.23 % + 0.15 µA
0.14 % + 0.15 µA
0.12 % + 0.15 µA
0.23 % + 0.2 µA
0.58 % + 0.3 µA
1.2 % + 0.6 µA
0.21 % + 2 µA
0.1 % + 2 µA
0.046 % + 2 µA
0.092 % + 2 µA
0.23 % + 3 µA
0.46 % + 4 µA
0.21 % + 20 µA
0.1 % + 20
µA
0.046 % + 20 µA
0.12 % + 50 µA
0.23 % + 0.1 mA
0.46 % + 0.2 mA
0.21 % + 0.1 mA
0.058 % + 0.1 mA
0.069 % + 1 mA
2.9 % + 5 mA
0.21 % + 0.1 mA
0.069 % + 0.1 mA
0.69 % + 1 mA
2.9 % + 5 mA
0.069 % + 2 mA
0.12 % + 2 mA
3.5 % + 2 mA
0.14 % + 5 mA
0.17 % + 5 mA
3.5 % + 5 mA
Fluke 5522A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 6 of 15
Parameter/Range
Frequency
CMC2, 5, 9 (±)
Comments
AC Current – Generate
(cont)
3
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3) A
(3 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
(100 to 400) Hz
(10 to 100) Hz
(100 to 400) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.29 % + 0.2 µA
0.69 % + 0.5 µA
0.29 % + 0.3 µA
0.69 % + 0.8 µA
0.092 % + 4 µA
0.23 % + 10 µA
0.092 % + 40 µA
0.23 % + 0.1 mA
0.14 % + 0.2 mA
0.35 % + 1 mA
0.14 % + 2 mA
1.2 % + 5 mA
0.029 % + 0.003 A
0.83 % + 0.003 A
0.32 % + 0.025 A
0.87 % + 0.027 A
0.32 % + 0.09 A
1.5 % + 0.1 A
Fluke 5522A,
with LCOMP on
Fluke 5522A, 50 turn
coil
AC Power – Generate
PF=1
3
Up to 10.9 µW
(10.9 to 109 µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 37) W
(37 to 337) W
(0.337 to 1.12) kW
(1.12 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
0.55 W to 16.8 kW
(16.8 to 1045) kW
(45 to 65) Hz
0.17 %
0.13 %
0.06 %
0.056 %
0.055 %
0.055 %
0.055 %
0.058 %
0.063 %
0.076 %
0.081 %
0.09 %
0.17 %
0.23 %
0.25 %
Fluke 5522A
Fluke 5520A + 50 turn
coil | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 7 of 15
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Capacitance – Generate
3
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.58 % + 0.01 nF
0.58 % + 0.01 nF
0.58 % + 0.01 nF
0.29 % + 0.01 nF
0.29 % + 0.1 nF
0.29 % + 0.1 nF
0.29 % + 0.3 nF
0.29 % + 1 nF
0.29 % + 3 nF
0.29 % + 10 nF
0.46 % + 30 nF
0.52 % + 0.1 µF
0.52 % + 0.3 µF
0.52 % + 1 µF
0.52 % + 3 µF
0.52 % + 10 µF
0.87 % + 30 µF
1.2 % + 100 µF
Fluke 5522A
Electrical Calibration of
RTD Indicators –
Generate
3
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.04 °C
0.04 °C
0.04 °C
0.07 °C
0.08 °C
0.09 °C
0.19 °C
Fluke 5522A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 8 of 15
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators –
Generate & Measure
3
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.12 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.2 °C
0.31 °C
0.31 °C
0.18 °C
0.16 °C
0.15 °C
0.21 °C
0.44 °C
0.27 °C
0.26 °C
0.31 °C
0.36 °C
0.28 °C
0.29 °C
0.36 °C
0.49 °C
0.2 °C
0.13 °C
0.12 °C
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 9 of 15
Parameter/Equipment
Range
CMC2, 4, 5, 9 (±)
Comments
DC Voltage – Measure3
(0 to 100) mV
(0.10 to 1.0) V
(1.0 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 6) kV
(6 to 40) kV
16 µV/V + 0.3 µV
12 µV/V + 0.3 µV
11 µV/V + 0.5 µV
14 µV/V + 30 µV
15 µV/V + 100 µV
1.2 %
2.3 %
Agilent 3458A
Fluke 80K-6, DMM
Fluke 80K-40, DMM
Resistance – Measure3
Up to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
10 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 100) GΩ
28 µΩ/Ω + 50 µΩ
18 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 5 mΩ
18 µΩ/Ω + 50 mΩ
27 µΩ/Ω + 2 Ω
77 µΩ/Ω + 100 Ω
0.06 % + 1 kΩ
77 μΩ/Ω
0.54 %
0.70 %
Agilent 3458A
Voltage source & µA
range of 3458A
DC Current – Measure3
Up to 100 µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 50) A
(50 to 200) A
(200 to 1000) A
33 µA/A + 0.8 nA
29 µA/A + 5 nA
35 µA/A + 50 nA
49 µA/A + 0.5 µA
0.015 % + 10 µA
0.12 %
0.14 %
0.32 %
0.39 %
Agilent 3458A
Empro shunts, DMM | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 10 of 15
Parameter/Range
Frequency
CMC2, 4, 5, 9 (±)
Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(0.7 to 6) kV
(6 to 28) kV
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(DC to 500) Hz
60 Hz
0.035 % + 3 µV
0.046 % + 1.1 µV
0.076 % + 1.1 µV
0.46 % + 1.1 µV
0.77 % + 1.1 µV
4.7 % + 2 µV
0.011 % + 4 µV
0.014 % + 2 µV
0.026 % + 2 µV
0.12 % + 2 µV
0.23 % + 2 µV
0.41 % + 10 µV
1.2 % + 10 µV
0.011 % + 40 µV
0.015 % + 20 µV
0.023 % + 20 µV
0.042 % + 20 µV
0.11 % + 20 µV
0.36 % + 100 µV
1.2 % + 100 µV
95 µV/V + 0.4 mV
0.011 % + 0.2 mV
0.02 % + 0.2 mV
0.037 % + 0.2 mV
0.095 % + 0.2 mV
0.36 % + 1 mV
1.2 % + 1 mV
0.025 % + 4 mV
0.025 % + 2 mV
0.027 % + 2 mV
0.048 % + 2 mV
0.15 % + 2 mV
0.47 % + 10 mV
1.7 % + 10 mV
0.048 % + 40 mV
0.048 % + 20 mV
0.07 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
1.4 %
5.8 %
Agilent 3458A
Fluke 80K-6, DMM
Fluke 80K-40, DMM | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 11 of 15
Parameter/Range
Frequency
CMC2, 4, 5, 9 (±)
Comments
AC Current – Measure
3
Up to 100 μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 50) A
(50 to 200) A
(200 to 1000) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
0.46 % + 0.03 µA
0.17 % + 0.03 µA
0.072 % + 0.03 µA
0.072 % + 0.03 µA
0.46 % + 0.2 µA
0.17 % + 0.2 µA
0.073 % + 0.2 µA
0.041 % + 0.2 µA
0.069 % + 0.2 µA
0.46 % + 2 µA
0.17 % + 2 µA
0.072 % + 2 µA
0.041 % + 2 µA
0.069 % + 2 µA
0.46 % + 20 µA
0.17 % + 20 µA
0.073 % + 20 µA
0.041 % + 20 µA
0.069 % + 20 µA
0.47 % + 200 µA
0.2 % + 200 µA
0.11 % + 200 µA
0.13 % + 200 µA
0.35 % + 200 µA
0.12 %
0.14 %
0.32 %
0.39 %
Agilent 3458A
Empro shunts, DMM | to 1000 A |
| 12 | NCSLI RISP 4 | - | See scope document |
| 13 | NCSLI RISP 4 | - | 5 to 2000 lbf-in to lbf-ft |
| 14 | NIST SP 960-12 | - | See scope document |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.04) 07/14/2025 Page 15 of 15
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification. | ||
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
4 other sites in this organization
Labs with overlapping accredited scope in United States
- Ludlum MeasurementsSweetwater, TX · ~197 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ETS LindgrenCedar Park, TX · ~456 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Southwest Research InstituteSan Antonio, TX · ~458 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- NI Global Calibration Services dba NI Calibration Services AustinAustin, TX · ~474 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mensor, LPSan Marcos, TX · ~476 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.