Registers refreshed 2026-11-20.See refresh dates
United States

JM Test Systems, LLC.

738 S. Main Street, 77531, Clute, TX, United States

Visit website
A2LA 1995.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
19
A2LA certificate
1
Sites in our directory
5
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 19 scope lines.

A2LA certificate 1995.03 · 19 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 4 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 2 of 18 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 8 (±) Comments DC Voltage 3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V (0 to 330) mV (0.33 to 33) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 8.6 µV/V + 0.6 µV 7.3 µV/V + 1 µV 7.3 µV/V + 3.5 µV 7.2 µV/V + 6.5 µV 8.4 µV/V + 80 µV 10 µV/V + 500 µV 24 µV/V + 1 µV 13 µV/V + 2 µV 15 µV/V + 20 µV 21 µV/V + 0.15 mV 21 µV/V + 1.5 mV Fluke 5700A Fluke 5522A DC Current3 – Generate (0 to 220) μA (0.22 to 22) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 52 µA/A + 8 nA 52 µA/A + 8 nA 52 µA/A + 80 nA 65 µA/A + 0.8 µA 84 µA/A + 25 µA 0.017 % + 0.02 µA 0.012 % + 0.05 µA 0.012 % + 0.25 µA 0.012 % + 2.5 µA 0.023 % + 40 µA 0.044 % + 40 µA 0.059 % + 0.5 mA 0.12 % + 0.75 mA 0.25 % + 0.002 A 0.26 % + 0.015 A 0.28 % + 0.05 A Fluke 5700A Fluke 5522A Fluke 5522A, 50 turn coil
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 3 of 18 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Resistance – Generate Fixed Points Fixed points for Insulation testers 3 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 41 µΩ 98 µΩ/Ω 98 µΩ/Ω 30 µΩ/Ω 28 µΩ/Ω 20 µΩ/Ω 18 µΩ/Ω 17 µΩ/Ω 14 µΩ/Ω 16 µΩ/Ω 14 µΩ/Ω 20 µΩ/Ω 16 µΩ/Ω 24 µΩ/Ω 23 µΩ/Ω 46 µΩ/Ω 51 µΩ/Ω 110 µΩ/Ω 0.012 MΩ 0.12 MΩ 1.2 MΩ 0.012 GΩ 0.24 GΩ 5.8 GΩ Fluke 5700A Fixed Resistors
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 4 of 18 Parameter/Equipment Range CMC2, 8 (±) Comments Fixed Points for Ground Testers & Other Low Resistance Ohmmeters 3 Resistance 3 – Generate 0.1 mΩ 0.5 mΩ 1 mΩ 2 mΩ 5 mΩ 10 mΩ 20 mΩ 50 mΩ 0.1 Ω 0.2 Ω 0.5 Ω 1 Ω Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 33) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.39 µΩ 1.6 µΩ 3.2 µΩ 6.3 µ Ω 15 µΩ 29 µΩ 28 µΩ 66 µΩ 0.12 mΩ 0.25 mΩ 0.60 mΩ 1.2 mΩ 51 µΩ/Ω + 0.001 Ω 35 µΩ/Ω + 0.0015 Ω 33 µΩ/Ω + 0.0014 Ω 33 µΩ/Ω + 0.002 Ω 33 µΩ/Ω + 0.002 Ω 33 µΩ/Ω + 0.02 Ω 33 µΩ/Ω + 0.02 Ω 33 µΩ/Ω + 0.2 Ω 33 µΩ/Ω + 0.2 Ω 37 µΩ/Ω + 2 Ω 38 µΩ/Ω + 2 Ω 70 µΩ/Ω + 30 Ω 0.015 % + 50 Ω 0.029 % + 2.5 kΩ 0.060 % + 3 kΩ 0.35 % + 0.1 MΩ 1.7 % + 0.5 MΩ Current shunts Fluke 5522A DC Power3 – Generate Up to 109 µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 109) W (109 to 337) W (337 to 990) W (0.99 to 3.06) kW (3.06 to 11.2) kW 11.2 to 20.9) kW 5.5 W to 16.8 kW (16.8 to 153) kW (153 to 1045) kW 0.023 % 0.014 % 0.013 % 0.013 % 0.013 % 0.013 % 0.013 % 0.013 % 0.027 % 0.045 % 0.064 % 0.12 % 0.19 % 0.20 % 0.21 % Fluke 5522A Fluke 5522A + 50 turn coil
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 5 of 18 Parameter/Range Frequency CMC2, 8 (±) Comments AC Voltage 3 – Generate Up to 33 mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.095 % + 6 µV 0.019 % + 6 µV 0.024 % + 6 µV 0.12 % + 6 µV 0.4 % + 12 µV 0.93 % + 50 µV 0.035 % + 8 µV 0.017 % + 8 µV 0.019 % + 8 µV 0.041 % + 8 µV 0.093 % + 32 µV 0.23 % + 70 µV 0.035 % + 50 µV 0.017 % + 60 µV 0.022 % + 60 µV 0.035 % + 50 µV 0.081 % + 0.13 mV 0.28 % + 0.6 mV 0.035 % + 0.65 mV 0.017 % + 0.6 mV 0.028 % + 0.6 mV 0.04 % + 0.6 mV 0.1 % + 1.6 mV 0.022 % + 2 mV 0.023 % + 6 mV 0.029 % + 6 mV 0.035 % + 6 mV 0.23 % + 50 mV 0.035 % + 10 mV 0.029 % + 10 mV 0.035 % + 10 mV Fluke 5522A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 6 of 18 Parameter/Range Frequency CMC2, 4, 8 (±) Comments AC Voltage 3 – Generate Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.2 % + 4.5 µV 0.11 % + 4.5 µV 0.083 % + 4.5 µV 0.14 % + 4.5 µV 0.2 % + 7 µV 0.34 % + 13 µV 0.44 % + 25 µV 0.57 % + 25 µV 0.064 % + 5 µV 0.029 % + 5 µV 0.017 % + 5 µV 0.045 % + 5 µV 0.094 % + 7 µV 0.14 % + 12 µV 0.2 % + 25 µV 0.38 % + 25 µV 0.06 % + 13 µV 0.023 % + 8 µV 0.011 % + 8 µV 0.034 % + 8 µV 0.088 % + 25 µV 0.12 % + 25 µV 0.18 % + 35 µV 0.36 % + 80 µV 0.055 % + 80 µV 0.018 % + 25 µV 80 µV/V + 6 µV 0.013 % + 16 µV 0.027 % + 70 µV 0.048 % + 130 µV 0.11 % + 350 µV 0.24 % + 0.85 mV 0.055 % + 0.8 mV 0.018 % + 250 µV 81 µV/V + 60 µV 0.013 % + 160 µV 0.027 % + 350 µV 0.055 % + 1.5 mV 0.13 % + 4.3 mV 0.3 % + 8.5 mV Fluke 5700A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 7 of 18 Parameter/Range Frequency CMC2, 4, 8 (±) Comments AC Voltage 3 – Generate (cont) (22 to 220) V (220 to 250) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 0.055 % + 8 mV 0.018 % + 2.5 mV 87 µV/V + 0.8 mV 0.023 % + 3.5 mV 0.052 % + 8 mV 0.15 % + 90 mV 0.48 % + 90 mV 1.2 % + 190 mV 0.041 % + 16 mV 91 µV/V + 3.5 mV Fluke 5700A Note: Voltage output above 100 kHz exhibits a linear drop off of -2.2 mV per Hz above 100 kHz. AC Current 3 – Generate Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (0.33 to 1.1) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.23 % + 0.1 µA 0.17 % + 0.1 µA 0.14 % + 0.1 µA 0.35 % + 0.15 µA 0.92 % + 0.2 µA 1.8 % + 0.4 µA 0.23 % + 0.15 µA 0.14 % + 0.15 µA 0.12 % + 0.15 µA 0.23 % + 0.2 µA 0.58 % + 0.3 µA 1.2 % + 0.6 µA 0.21 % + 2 µA 0.1 % + 2 µA 0.046 % + 2 µA 0.092 % + 2 µA 0.23 % + 3 µA 0.46 % + 4 µA 0.21 % + 20 µA 0.1 % + 20 µA 0.046 % + 20 µA 0.12 % + 50 µA 0.23 % + 0.1 mA 0.46 % + 0.2 mA Fluke 5522A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 8 of 18 Parameter/Range Frequency CMC2, 4, 8 (±) Comments AC Current3 – Generate (10 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.076 % + 25 nA 0.039 % + 20 nA 0.02 % + 16 nA 0.063 % + 40 nA 0.17 % + 80 nA 0.076 % + 40 nA 0.039 % + 35 nA 0.02 % + 35 nA 0.063 % + 0.4 µA 0.17 % + 0.8 µA 0.073 % + 0.4 µA 0.038 % + 0.35 µA 0.02 % + 0.35 µA 0.063 % + 4 µA 0.16 % + 8 µA 0.073 % + 4 µA 0.038 % + 3.5 µA 0.02 % + 3.5 µA 0.063 % + 40 µA 0.16 % + 80 µA 0.068 % + 35 µA 0.078 % + 80 µA 0.87 % + 160 µA 0.21 % + 0.1 mA 0.069 % + 0.1 mA 0.69 % + 1 mA 2.9 % + 5 mA 0.069 % + 2 mA 0.12 % + 2 mA 3.5 % + 2 mA 0.14 % + 5 mA 0.17 % + 5 mA 3.5 % + 5 mA Fluke 5700A Fluke 5522A
10 to 20.5 A
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 9 of 18 Parameter/Range Frequency CMC2, 8 (±) Comments AC Current 3 – Generate (cont) Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz (100 to 400) Hz (10 to 100) Hz (100 to 400) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.29 % + 0.2 µA 0.69 % + 0.5 µA 0.29 % + 0.3 µA 0.69 % + 0.8 µA 0.092 % + 4 µA 0.23 % + 10 µA 0.092 % + 40 µA 0.23 % + 0.1 mA 0.14 % + 0.2 µA 0.35 % + 1 mA 0.14 % + 2 mA 1.2 % + 5 mA 0.029 % + 0.003 A 0.083 % + 0.003 A 0.32 % + 0.025 A 0.87 % + 0.027 A 0.32 % + 0.09 A 1.5 % + 0.1 A Fluke 5522A with LCOMP On Fluke 5522A, 50 turn coil AC Power 3 – Generate (45 to 65 Hz, PF=1) Up to 10.9 µW (10.9 to 109 µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 37) W (37 to 337) W (0.337 to 1.12) kW (1.12 to 3.06) kW (3.06 to 11.2) kW (11.2 to 20.9) kW 0.55 W to 16.8 kW (16.8 to 1045) kW 0.17 % 0.13 % 0.06 % 0.056 % 0.055 % 0.055 % 0.055 % 0.058 % 0.063 % 0.076 % 0.081 % 0.09 % 0.17 % 0.23 % 0.25 % Fluke 5522A Fluke 5522A + 50 turn coil
to 1025 A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 10 of 18 Parameter/Equipment Range CMC2, 8 (±) Comments Capacitance 3 – Generate (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.58 % + 0.01 nF 0.58 % + 0.01 nF 0.58 % + 0.01 nF 0.29 % + 0.01 nF 0.29 % + 0.1 nF 0.29 % + 0.1 nF 0.29 % + 0.3 nF 0.29 % + 1 nF 0.29 % + 3 nF 0.29 % + 10 nF 0.46 % + 30 nF 0.52 % + 0.1 µF 0.52 % + 0.3 µF 0.52 % + 1 µF 0.52 % + 3 µF 0.52 % + 10 µF 0.87 % + 30 µF 1.2 % + 100 µF Fluke 5522A Electrical Calibration of Thermocouple Indicators3 – Generate & Measure Type E Type J (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.19 °C Fluke 5522A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 11 of 18 Parameter/Equipment Range CMC2, 8 (±) Comments Electrical Calibration of Thermocouple Indicators 3 – Generate & Measure (cont) Type K Type N Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.26 °C 0.15 °C 0.13 °C 0.20 °C 0.31 °C 0.31 °C 0.18 °C 0.16 °C 0.15 °C 0.21 °C 0.49 °C 0.20 °C 0.13 °C 0.12 °C Fluke 5522A Electrical Calibration of RTD Indicators 3 – Generate Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.04 °C 0.04 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.19 °C Fluke 5522A Electrical Calibration of Phase Indicators3 – Generate (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.12 °phase 0.3 °phase 0.6 °phase 2.9 °phase 6 °phase 12 °phase Fluke 5522A
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 12 of 18 Parameter/Equipment Range CMC2, 5, 8 (±) Comments DC Voltage3 – Measure (0 to 100) mV (0.10 to 1.0) V (1.0 to 10) V (10 to 100) V (100 to 1000) V 11 µV/V + 0.3 µV 10 µV/V + 0.3 µV 10 µV/V + 0.5 µV 13 µV/V + 30 µV 14 µV/V + 100 µV Agilent 3458A DC High Voltage3 – Generate & Measure (1 to 100) kV 1.2 % Phenix KVM-(series) Resistance3 – Measure Up to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 10 MΩ to 1 GΩ (1 to 10) GΩ (10 to 100) GΩ 21 µΩ/Ω + 50 µΩ 18 µΩ/Ω + 0.5 mΩ 17 µΩ/Ω + 0.5 mΩ 16 µΩ/Ω + 5 mΩ 19 µΩ/Ω + 50 mΩ 24 µΩ/Ω + 2 Ω 70 µΩ/Ω + 100 Ω 0.060 % + 1 kΩ 77 μΩ/Ω 0.54 % 0.70 % Agilent 3458A Voltage source & µA range of 3458A DC Current3 – Measure Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 50) A (50 to 200) A (200 to 1000) A 35 µA/A + 0.8 nA 35 µA/A + 5 nA 40 µA/A + 50 nA 53 µA/A + 0.5 µA 0.018 % + 10 µA 0.12 % 0.14 % 0.32 % 0.39 % Agilent 3458A Current shunts, DMM
to 1000 A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 13 of 18 Parameter/Range Frequency CMC2, 5, 8 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 700) V (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 40) Hz 40 Hz to 1 kHz (1to20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.051 % + 3 µV 0.056 % + 1.1 µV 0.083 % + 1.1 µV 0.46 % + 1.1 µV 0.78 % + 1.1 µV 4.7 % + 2 µV 0.013 % + 4 µV 0.016 % + 2 µV 0.027 % + 2 µV 0.12 % + 2 µV 0.23 % + 2 µV 0.41 % + 10 µV 1.2 % + 10 µV 0.011 % + 40 µV 0.016 % + 20 µV 0.024 % + 20 µV 0.041 % + 20 µV 0.11 % + 20 µV 0.36 % + 100 µV 1.2 % + 100 µV 0.029 % + 0.4 mV 0.012 % + 0.2 mV 0.020 % + 0.2 mV 0.037 % + 0.2 mV 0.095 % + 0.2 mV 0.36 % + 1 mV 1.2 % + 1 mV 0.025 % + 4 mV 0.025 % + 2 mV 0.026 % + 2 mV 0.048 % + 2 mV 0.15 % + 2 mV 0.47 % + 10 mV 1.7 % + 10 mV 0.048 % + 40 mV 0.048 % + 20 mV 0.070 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV Agilent 3458A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 14 of 18 Parameter/Range Frequency CMC2, 5, 8 (±) Comments AC High Voltage – Generate & Measure 3 (0.7 to 6) kV (6 to 80 kV) (DC to 500) Hz 60 Hz 1.5 % 1.6 % Fluke 80K-6, DMM Phenix KVM-(series) AC Current3 – Measure Up to 100 μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 50) A (50 to 200) A (200 to 1000) A (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz 0.46 % + 0.03 µA 0.18 % + 0.03 µA 0.074 % + 0.03 µA 0.074 % + 0.03 µA 0.46 % + 0.2 µA 0.18 % + 0.2 µA 0.076 % + 0.2 µA 0.047 % + 0.2 µA 0.074 % + 0.2 µA 0.46 % + 2 µA 0.18 % + 2 µA 0.077 % + 2 µA 0.048 % + 2 µA 0.074 % + 2 µA 0.46 % + 20 µA 0.18 % + 20 µA 0.077 % + 20 µA 0.049 % + 20 µA 0.075 % + 20 µA 0.47 % + 200 µA 0.2 % + 200 µA 0.12 % + 200 µA 0.14 % + 200 µA 0.35 % + 200 µA 0.12 % 0.14 % 0.32 % 0.39 % Agilent 3458A Current shunts, DMM
15Direct cross-float method- Ruska 2400-See scope document
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 16 of 18 Parameter/Equipment Range CMC2, 6, 9 (±) Comments Pneumatic Pressure – Measure &/or Measuring Equipment Effective Area Determination of High Accuracy Piston- Cylinder Unit (PCU) or Ball- Nozzle Units (BNU) Calibration of Transfer Standards & Pressure Devices (0.14 to 30) psi (0.14 to 300) psi 0.0085 % 0.0081 % Direct cross-float method– PK DWT, Std. Mass RK-300/1100WC Torque Devices (Wrenches, Drivers, Screwdrivers) 3 5 lbfꞏin to 2000 lbfꞏft 1.2 % Torque Calibrator IV. Thermodynamics Parameter/Equipment Range CMC 2, 9 (±) Comments Temperature – Measure3 (-38 to 0) °C (0 to 156) °C (156 to 420) °C (420 to 660) °C 0.019 °C 0.023 °C 0.052 °C 0.099 °C PRT, readout Temperature – Measuring Equipment3 (-25 to 0) °C (0 to 156) °C (156 to 250) °C 0.013 °C 0.019 °C 0.051 °C PRT, readout, bath
17NIST SP 960-12-See scope document
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.03) 12/09/2025 Page 18 of 18 5 Agilent 3458A CMCs are based upon the temper ature the standard was calibrated (tcal ± 5 oC) and an auto calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature.) CMCs are also based upon 1-year floor specifications . CMCs are expressed as either a specific value that covers the full range or as a combination of a percent or the fraction of the reading/output plus a range specification. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. 7 Applicable when the internal time base (oscillator) of the device under test is/can be measured directly by the frequency counter. 8 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 9 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 10 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 11 This scope meets A2LA’s P112 Flexible Scope Policy.
19ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

738 S. Main Street, Clute, TX, 77531, US

29.02469, -95.39883

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.