G.T. MICHELLI CO., LLC - HOUSTON

15050 West Dr., 77053, Houston, TX, United States

Visit website
A2LA 3601.10ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
10
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 10 scope lines.

A2LA certificate 3601.10 · 10 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 40 in
2-DC Voltage; DC Current; AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 2 of 9 II. Electrical DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate3 (0 to 329.9999) mV (0 to 3.299 999) V (0 to 32.999 99) V (30 to 329.9999) V (100 to 1020) V 51 µV/V + 2.3 µV 38 µV/V + 3.9 µV 38 µV/V + 39 µV 44 µV/V + 390 µV 45 µV/V + 1200 µV Fluke 5500A DC Current – Generate3 (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 2.2) A (2.2 to 11) A 190 µA/A + 0.039 µA 82 µA/A + 0.19 µA 100 µA/A + 1.9 µA 300 µA/A + 34 µA 870 µA/A + 580 µA Fluke 5500A DC Voltage – Measure3 Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1050) V 8.0 µV/V + 0.30 µV 7.3 µV/V + 0.30 µV 7.0 µV/V + 0.5 µV 9.4 µV/V + 30 µV 13 µV/V + 100 µV Keysight 3458A DC Current – Measure3 Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 35 µA/A + 0.80 nA 18 µA/A + 5.0 nA 20 µA/A + 50 nA 36 µA/A + 0.50 µA 100 µA/A + 10 µA Keysight 3458A AC Voltage – Generate3 Up to 33 mV (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.12 % + 0.016 mV 0.078 % + 0.016 mV 0.12 % + 0.016 mV 0.16 % + 0.016 mV 0.31 % + 0.026 mV 0.84 % + 0.047 mV 0.048 % + 0.016 mV 0.024 % + 0.016 mV 0.055 % + 0.016 mV 0.080 % + 0.031 mV 0.18 % + 0.13 mV 0.41 % + 0.26 mV Fluke 5500A
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 3 of 9 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.045 % + 47 µV 0.024 % + 47 µV 0.055 % + 47 µV 0.078 % + 47 µV 0.19 % + 0.16 mV 0.41 % + 0.70 mV 0.045 % + 0.62 mV 0.027 % + 0.47 mV 0.055 % + 0.47 mV 0.078 % + 0.47 mV 0.18 % + 1.6 mV 0.039 % + 2.3 mV 0.061 % + 7.0 mV 0.071 % + 7.0 mV 0.10 % + 7.0 mV 0.19 % + 0.062 V 0.039 % + 0.016 V 0.062 % + 0.016 V 0.070 % + 0.016 V Fluke 5500A AC Voltage – Measure3 Up to 100 mV (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300 kHz (0.3 to 1) MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz 0.0072 % + 0.0048 mV 0.0096 % + 0.0024 mV 0.017 % + 0.0024 mV 0.031 % + 0.0024 mV 0.092 % + 0.0024 mV 0.41 % + 0.012 mV 1.3 % + 0.012 mV 4.1 % + 0.084 mV 4.2 % + 0.096 mV 15 % + 0.12 mV Keysight 3458A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 4 of 9 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (cont) (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 750) V (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300 kHz (0.3 to 1) MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300 kHz (0.3 to 1) MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.0082 % + 48 µV 0.0086 % + 24 µV 0.016 % + 24 µV 0.036 % + 24 µV 0.079 % + 24 µV 0.32 % + 0.12 mV 0.99 % + 0.12 mV 4.0 % + 0.84 mV 4.1 % + 0.96 mV 15 % + 1.2 mV 0.016 % + 0.48 mV 0.0086 % + 0.24 mV 0.016 % + 0.24 mV 0.033 % + 0.24 mV 0.082 % + 0.24 mV 0.32 % + 1.2 mV 0.99 % + 1.2 mV 4.0 % + 8.4 mV 4.0 % + 9.6 mV 15 % + 0.012 V 0.020 % + 4.8 mV 0.021 % + 2.4 mV 0.022 % + 2.4 mV 0.036 % + 2.4 mV 0.12 % + 2.4 mV 0.041 % + 0.040 V 0.047 % + 0.020 V 0.063 % + 0.020 V 0.12 % + 0.020 V 0.30 % + 0.020 V Keysight 3458A AC Current – Measure3 (Up to 100) µA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz 0.40 % + 3.6 nA 0.15 % + 3.6 nA 0.060 % + 3.6 nA 0.064 % + 3.6 nA Keysight 3458A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 5 of 9 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure3 (cont) (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.41 % + 0.24 µA 0.15 % + 0.24 µA 0.06 % + 0.24 µA 0.031 % + 0.24 µA 0.06 % + 0.24 µA 0.4 % + 0.48 µA 0.55 % + 1.8 µA 0.41 % + 2.4 µA 0.15 % + 2.4 µA 0.06 % + 2.4 µA 0.032 % + 2.4 µA 0.06 % + 2.4 µA 0.4 % + 4.8 µA 0.55 % + 18 µA 0.41 % + 24 µA 0.15 % + 24 µA 0.06 % + 24 µA 0.031 % + 24 µA 0.06 % + 24 µA 0.4 % + 48 µA 0.55 % + 0.18 mA 0.4 % + 0.21 mA 0.16 % + 0.21 mA 0.08 % + 0.21 mA 0.1 % + 0.21 mA 0.3 % + 0.21 mA 1 % + 0.42 mA Keysight 3458A Resistance – Measure3 Up to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 17 µΩ/Ω + 50 µΩ 15 µΩ/Ω + 0.50 mΩ 18 µΩ/Ω + 0.50 mΩ 14 µΩ/Ω + 5.0 mΩ 14 µΩ/Ω + 50 mΩ 220 µΩ/Ω + 2.0 Ω 180 µΩ/Ω + 0.10 kΩ 0.087 % + 1.0 kΩ 0.41 % + 10 kΩ Keysight 3458A
6-thermocouple indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 6 of 9 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate3 Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 0.017 % + 0.78 mΩ 0.014 % + 1.2 mΩ 0.0076 % + 1.1 mΩ 0.0075 % + 1.6 mΩ 0.0073 % + 1.6 mΩ 0.0071 % + 1.6 mΩ 0.0070 % + 1.6 mΩ 0.0071 % + 0.16 Ω 0.0088 % + 0.16 mΩ 0.0095 % + 1.6 Ω 0.012 % + 1.6 Ω 0.014 % + 23 Ω 0.057 % + 39 Ω 0.12 % + 1.9 kΩ 0.53 % + 2.3 kΩ 1.1 % + 0.078 MΩ Fluke 5500A Electrical Calibration of Thermocouple Indicators3 – Generate & Measure Type B Type C Type E Type J (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.44 °C 0.36 °C 0.32 °C 0.35 °C 0.30 °C 0.27 °C 0.31 °C 0.44 °C 0.70 °C 0.43 °C 0.20 °C 0.19 °C 0.20 °C 0.23 °C 0.26 °C 0.18 °C 0.17 °C 0.21 °C 0.24 °C Fluke 5500A
-
7-Thermocouple Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 7 of 9 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Indicators3 – Generate & Measure (cont) Type K Type N Type R Type S Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.33 °C 0.20 °C 0.21 °C 0.25 °C 0.37 °C 0.40 °C 0.25 °C 0.22 °C 0.21 °C 0.27 °C 0.51 °C 0.37 °C 0.34 °C 0.38 °C 0.46 °C 0.36 °C 0.37 °C 0.44 °C 0.52 °C 0.24 °C 0.18 °C 0.20 °C Fluke 5500A
See scope document
8-Scales and Balances; Truck & Rail Scales; Weight cart and weight blocks; Pressure – Measuring Equipment; Pressure transducers; Torque – Measuring Equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 8 of 9 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Scales and Balances3 Truck & Rail Scales3 (5 to 20) g (20 to 50) g (50 to 200) g (200 to 1000) g (1 to 5) kg (1 to 10) lb (10 to 25) lb (25 to 50) lb (50 to 500) lb (500 to 1000) lb (1000 to 5000) lb (6000 to 30 000) lb 1.5 mg 5.2 mg 5.4 mg 6.5 g 0.0065 kg 0.0026 lb 0.0065 lb 0.013 lb 0.13 lb 0.26 lb 1.6 lbs 1.4 lb ASTM Class 6 (applied load) Weight cart and weight blocks (applied load) Pressure – Measuring Equipment3 (-14 to 0) psig (0 to 30) psig (0 to 100) psig (0 to 500) psig (0 to 1000) psig (0 to 3000) psig (0 to 5000) psig (0 to 10 000) psig (0 to 20 000) psig 0.0027 psig 0.0037 psig 0.019 psig 0.069 psig 0.18 psig 0.35 psig 0.57 psig 1.6 psig 3.7 psig Pressure transducers Torque – Measuring Equipment3 (5 to 25) lbf·in (25 to 50) lbf·in (50 to 250) lbf·in (250 to 500) lbf·in (25 to 125) lbf·ft (125 to 250) lbf·ft (100 to 500) lbf·ft (500 to 1000) lbf·ft 0.058 lbf·in 0.066 lbf·in 0.51 lbf·in 0.91 lbf·in 0.19 lbf·ft 0.76 lbf·ft 1.6 lbf·ft 4.6 lbf·ft Mountz BMX50i Mountz BMX500i Mountz BMX250F Mountz BMX1000F
-
9-Temperature – Measuring Equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.10) Revised 06/24/2026 Page 9 of 9 IV. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature – Measuring Equipment3 Up to 50 °C (50 to 420) °C (420 to 660) °C (-25 to 140) °C 0.072 °C 0.42 °C 0.60 °C 0.036 °C Fluke 9144 field metrology well with Fluke 5609 PRT Fluke 7109A Portable bath w/Fluke 5609 PRT __________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
See scope document
10ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

15050 West Dr., Houston, TX, 77053, US

29.75894, -95.36770

Open in Maps