Mensor, LP

201 Barnes Drive, 78666, San Marcos, TX, United States

Visit website
A2LA 2066.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 2066.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-0 to 100 V
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2066.01) Revised 02/11/2026 Page 2 of 3 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate– Generate 1 Ω 100 Ω 450 Ω 1 kΩ 45 kΩ 500 kΩ 1 MΩ 5.6 μΩ/Ω 550 μΩ/Ω 2.5 mΩ/Ω 5.5 mΩ/Ω 460 mΩ/Ω 7.5 Ω/Ω 15 Ω/Ω Ohm Labs Multiple Resistance Standard (MRS) – Fixed Range Resistors II. Mechanical Parameter/Equipment Range CMC 2, 4, 6 (±) Comments Pressure – Gauges, Controllers, & Transducers Gauge, Pneumatic Absolute, Pneumatic Absolute/Gage, Pneumatic Absolute/Gauge, Hydraulic (-370 to -93) kPa (-93 to 0) kPa (0 to 172) kPa (0 to 172) kPa (172 to 6900) kPa (6.9 to 55) MPa (55 to 103) MPa (1 to 207) MPa (207 to 500) MPa 0.0017 % 0.000 91 % + 7 mPa 0.000 86 % + 9.5 mPa 0.000 91 % + 35 mPa 0.0012 % 0.0019 % 0.0021 % 0.0028 % 0.0072 % Fluke CPC6050 Dual Ruska DWTs Ruska DWTs Ruska DWTs DHB DWTs DHB DWTs Fluke DWTs DHB DWTs DHB DWTs Mass – Measure Up to 1 kg (1 to 10) kg 0.24 mg 2.5 mg Reference mass set and Mettler balance III. Thermodynamics Parameter/Equipment Range CMC 2, 4 (±) Comments Temperature – Measuring Equipment (-40 to 420) °C 0.057 °C PRT ____________________________________________
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2066.01) Revised 02/11/2026 Page 3 of 3 1 Commercial calibration service is available for this laboratory. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

201 Barnes Drive, San Marcos, TX, 78666, US

29.88264, -97.94058

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.