Przedsiębiorstwo Wodociągów i Kanalizacji Sp. z o.o. w Wyszkowie
ul. Komunalna 12, 07-200, Wyszków, Poland
- Accredited standards
- 13
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO11
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7150-1Water quality - Determination of ammonium - Part 1: Manual spectrometric method
ISO 7887Water quality - Examination and determination of colour
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10523Water quality - Determination of pH
ISO 19458Water quality - Sampling for microbiological analysis
Other standards2
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
PN-ISO 5667-5:2017-10; PN-EN ISO 19458:2007; PN-EN ISO 9308-2:2014-06; PN-EN ISO 7887:2012 p.6 +Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10523:2012; PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06; PN-ISO 6059:1999; PN-82/C-04576-08; PN-EN 26777:1999; PN-ISO 9297:1994; PN-EN 27888:1999; PN-ISO 7150-1:2002
PN-EN ISO 8467:2001
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
3 lines
ISO/IEC 17025
ActiveAB 1850
The scope document we hold says it is valid until 2027-01-08.
Accredited scope, certificate AB 1850
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1850
Scope of accreditation No. AB 1850
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1850
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 4 z/of 07.10.2025
p.o. KIEROWNIK A DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr A B 1850 z dnia 09.01.2023 r.
Cykl akredytacji od 09.01.2023 r. do 08.01.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 1850 of 09.01.2023
Accreditation cycle from 09.01.2023 to 08.01.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 4, 07.10.2025 1/4
Nazwa i adres / Name and address
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.
w Wyszkowie
ul. Komunalna 1
07-200 Wyszków
DZIAŁ LABORATORIUM
ul. Komunalna 12
07-200 Wyszków
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/29/P
- N/29/P
- K/29/P
- Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi / Chemical tests and
sampling of drinking water
- Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi / Tests of
physical properties and sampling of drinking water
- Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi / Microbiological
tests and sampling of drinking water
Wersja strony / Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1850 | - |
| 2 | PN-ISO 5667-5:2017-10; PN-EN ISO 19458:2007; PN-EN ISO 9308-2:2014-06; PN-EN ISO 7887:2012 p.6 +Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10523:2012; PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06; PN-ISO 6059:1999; PN-82/C-04576-08; PN-EN 26777:1999; PN-ISO 9297:1994; PN-EN 27888:1999; PN-ISO 7150-1:2002 | Drinking water | See scope document |
| 3 | PN-EN ISO 8467:2001 | Drinking water | 0.5 to 10 mg/l O2 |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Badawcze INTERLABO A.Tomaszewski, M.Tomaszewski Spółka JawnaWarszawa · ~48 kmPCAShares 2 accredited methods and materialsISO 5667-5:2017-10Drinking water
- Intertek PolandGostynin · ~136 kmPCAShares 2 accredited methods and materialsISO 5667-5:2017-10Drinking water
- "EKO-SERWIS" s.c. Dorota Markowska, Maciej MarkowskiŁódź · ~163 kmPCAShares 2 accredited methods and materialsISO 5667-5:2017-10Drinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~185 kmPCAShares 2 accredited methods and materialsEN ISO 8467:2001Drinking water
- Przedsiębiorstwo Naukowo-Techniczne "EKOTERRA"Kielce · ~202 kmPCAShares 2 accredited methods and materialsEN ISO 8467:2001Drinking water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.