The Sherwin-Williams Company - Columbus
2121 New World Drive, 43207, Columbus, OH, United States
- Accredited standards
- 28
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 28 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM28
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM C1549
ASTM D523Standard Test Method for Specular Gloss
ASTM D610
ASTM D660
ASTM D661
ASTM D714
ASTM D772
ASTM D1308
ASTM D1654Exclusion
Limits written next to it
ASTM D1654 (except Procedure A, Method 5)
ASTM D1729
ASTM D2244
Show all 28
ASTM D2247
ASTM D2248
ASTM D3359
ASTM D4138
ASTM D4214
ASTM D4585
ASTM D4587
ASTM D4803
ASTM D5235
ASTM D5402
ASTM D5894
ASTM D7091
ASTM E805
ASTM G85
ASTM G154
ASTM G155
ASTM D4587; ASTM G154; ASTM G155; SAE J2527; AAMA 613 Section 7.10; AAMA 614 Section 7.10; AAMA 615 Section 7.10; AAMA 623 Section 7.8; AAMA 624 Section 7.10; AAMA 625 Section 7.10; AAMA 2603 Section 8.7.2; AAMA 2604 Section 8.8.2; AAMA 2605 Section 8.8.2; ASTM D5894; ASTM G85, Annex A5; AAMA 613 Section 7.12; AAMA 614 Section 7.12; AAMA 615 Section 7.12; ASTM D4803; AAMA 613 Section 7.8; AAMA 614 Section 7.8; AAMA 615 Section 7.8; AAMA 623 Section 7.7; AAMA 624 Section 7.9; AAMA 625 Section 7.9; AAMA 2603 Section 8.7.1; AAMA 2604 Section 8.8.1; AAMA 2605 Section 8.8.1; ASTM D2247; ASTM D4585; AAMA 613 Section 7.11; AAMA 614 Section 7.11; AAMA 615 Section 7.11; AAMA 623 Section 7.9; AAMA 624 Section 7.11; AAMA 625 Section 7.11; ASTM B117; ISO/IEC 17025:2017
AAMA 613 Section 7.1; AAMA 614 Section 7.1; AAMA 615 Section 7.1; AAMA 623 Section 7.1; AAMA 624 Section 7.1; AAMA 625 Section 7.1; AAMA 2603 Section 8.1; AAMA 2604 Section 8.1; AAMA 2605 Section 8.1; ASTM D1729; ASTM D2244; ASTM E805; ASTM C1549; ASTM D4138 (Method A); ASTM D5235; ASTM D7091; AAMA 613 Section 7.2; AAMA 614 Section 7.2; AAMA 615 Section 7.2; AAMA 623 Section 7.2; AAMA 624 Section 7.2; AAMA 625 Section 7.2; AAMA 2603 Section 8.2; AAMA 2604 Section 8.2; AAMA 2605 Section 8.2; ASTM D523; ASTM D1654 (except Procedure A, Method 5); ASTM D610; ASTM D660; ASTM D661; ASTM D714; ASTM D772; ASTM D4214
AAMA 614 Section 7.6; AAMA 615 Section 7.6; AAMA 624 Section 7.5; AAMA 625 Section 7.5; AAMA 2604 Section 8.6; AAMA 2605 Section 8.6; AAMA 613 Section 7.4; AAMA 614 Section 7.4; AAMA 615 Section 7.4; AAMA 623 Sections 7.4.2.1, 7.4.2.2, 7.4.3.1, 7.4.3.2; AAMA 624 Sections 7.4.2.1, 7.4.2.2, 7.4.3.1, 7.4.3.2, 7.4.4.1, 7.4.4.1.1; AAMA 625 Sections 7.4.2.1, 7.4.2.2, 7.4.3.1, 7.4.3.2, 7.4.4.1, 7.4.4.2; AAMA 2603 Section 8.4; AAMA 2604 Section 8.4; AAMA 2605 Section 8.4; ASTM D3359; AAMA 613 Section 7.5; AAMA 614 Section 7.5; AAMA 615 Section 7.5; AAMA 2603 Section 8.5; AAMA 2604 Section 8.5; AAMA 2605 Section 8.5; AAMA 613 Section 7.3; AAMA 614 Section 7.3; AAMA 615 Section 7.3; AAMA 623 Section 7.3; AAMA 624 Section 7.3; AAMA 625 Section 7.3; AAMA 2603 Section 8.3; AAMA 2604 Section 8.3; AAMA 2605 Section 8.3; AAMA 613 Section 7.7; AAMA 614 Section 7.7.4; AAMA 615 Section 7.7.4; AAMA 623 Section 7.6; AAMA 624 Section 7.7; AAMA 625 Section 7.7; AAMA 2603 Section 8.6.3; AAMA 2604 Section 8.7.4; AAMA 2605 Section 8.7.4; ASTM D2248; ASTM D5402; AAMA 613 Section 7.6; AAMA 614 Sections 7.7.1, 7.7.2, 7.7.3, 7.7.5; AAMA 615 Sections 7.7.1, 7.7.2, 7.7.3, 7.7.5; AAMA 623 Section 7.5; AAMA 624 Sections 7.6, 7.8; AAMA 625 Sections 7.6, 7.8; AAMA 2603 Sections 8.6.1, 8.6.2; AAMA 2604 Sections 8.7.1, 8.7.2, 8.7.3, 8.7.5; AAMA 2605 Sections 8.7.1, 8.7.2, 8.7.3, 8.7.5; ASTM D1308
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active1176.05
The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1176.05
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D4587; ASTM G154; ASTM G155; SAE J2527; AAMA 613 Section 7.10; AAMA 614 Section 7.10; AAMA 615 Section 7.10; AAMA 623 Section 7.8; AAMA 624 Section 7.10; AAMA 625 Section 7.10; AAMA 2603 Section 8.7.2; AAMA 2604 Section 8.8.2; AAMA 2605 Section 8.8.2; ASTM D5894; ASTM G85, Annex A5; AAMA 613 Section 7.12; AAMA 614 Section 7.12; AAMA 615 Section 7.12; ASTM D4803; AAMA 613 Section 7.8; AAMA 614 Section 7.8; AAMA 615 Section 7.8; AAMA 623 Section 7.7; AAMA 624 Section 7.9; AAMA 625 Section 7.9; AAMA 2603 Section 8.7.1; AAMA 2604 Section 8.8.1; AAMA 2605 Section 8.8.1; ASTM D2247; ASTM D4585; AAMA 613 Section 7.11; AAMA 614 Section 7.11; AAMA 615 Section 7.11; AAMA 623 Section 7.9; AAMA 624 Section 7.11; AAMA 625 Section 7.11; ASTM B117; ISO/IEC 17025:2017 | coatings | - |
| 2 | AAMA 614 Section 7.6; AAMA 615 Section 7.6; AAMA 624 Section 7.5; AAMA 625 Section 7.5; AAMA 2604 Section 8.6; AAMA 2605 Section 8.6; AAMA 613 Section 7.4; AAMA 614 Section 7.4; AAMA 615 Section 7.4; AAMA 623 Sections 7.4.2.1, 7.4.2.2, 7.4.3.1, 7.4.3.2; AAMA 624 Sections 7.4.2.1, 7.4.2.2, 7.4.3.1, 7.4.3.2, 7.4.4.1, 7.4.4.1.1; AAMA 625 Sections 7.4.2.1, 7.4.2.2, 7.4.3.1, 7.4.3.2, 7.4.4.1, 7.4.4.2; AAMA 2603 Section 8.4; AAMA 2604 Section 8.4; AAMA 2605 Section 8.4; ASTM D3359; AAMA 613 Section 7.5; AAMA 614 Section 7.5; AAMA 615 Section 7.5; AAMA 2603 Section 8.5; AAMA 2604 Section 8.5; AAMA 2605 Section 8.5; AAMA 613 Section 7.3; AAMA 614 Section 7.3; AAMA 615 Section 7.3; AAMA 623 Section 7.3; AAMA 624 Section 7.3; AAMA 625 Section 7.3; AAMA 2603 Section 8.3; AAMA 2604 Section 8.3; AAMA 2605 Section 8.3; AAMA 613 Section 7.7; AAMA 614 Section 7.7.4; AAMA 615 Section 7.7.4; AAMA 623 Section 7.6; AAMA 624 Section 7.7; AAMA 625 Section 7.7; AAMA 2603 Section 8.6.3; AAMA 2604 Section 8.7.4; AAMA 2605 Section 8.7.4; ASTM D2248; ASTM D5402; AAMA 613 Section 7.6; AAMA 614 Sections 7.7.1, 7.7.2, 7.7.3, 7.7.5; AAMA 615 Sections 7.7.1, 7.7.2, 7.7.3, 7.7.5; AAMA 623 Section 7.5; AAMA 624 Sections 7.6, 7.8; AAMA 625 Sections 7.6, 7.8; AAMA 2603 Sections 8.6.1, 8.6.2; AAMA 2604 Sections 8.7.1, 8.7.2, 8.7.3, 8.7.5; AAMA 2605 Sections 8.7.1, 8.7.2, 8.7.3, 8.7.5; ASTM D1308 | - | - |
| 3 | AAMA 613 Section 7.1; AAMA 614 Section 7.1; AAMA 615 Section 7.1; AAMA 623 Section 7.1; AAMA 624 Section 7.1; AAMA 625 Section 7.1; AAMA 2603 Section 8.1; AAMA 2604 Section 8.1; AAMA 2605 Section 8.1; ASTM D1729; ASTM D2244; ASTM E805; ASTM C1549; ASTM D4138 (Method A); ASTM D5235; ASTM D7091; AAMA 613 Section 7.2; AAMA 614 Section 7.2; AAMA 615 Section 7.2; AAMA 623 Section 7.2; AAMA 624 Section 7.2; AAMA 625 Section 7.2; AAMA 2603 Section 8.2; AAMA 2604 Section 8.2; AAMA 2605 Section 8.2; ASTM D523; ASTM D1654 (except Procedure A, Method 5); ASTM D610; ASTM D660; ASTM D661; ASTM D714; ASTM D772; ASTM D4214 | - | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
THE SHERWIN-WILLIAMS COMPANY – COLUMBUS
Columbus, OH
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 15th day of July 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1176.05
Valid to May 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Akron Rubber DevelopmentAkron, OH · ~181 kmA2LAShares 2 accredited test methodsASTM D2244ASTM G155
- Ghesquiere Plastic TestingHarper Woods, MI · ~275 kmA2LAShares 2 accredited test methodsASTM D2244ASTM G155
- Michigan Testing InstituteSterling Heights, MI · ~291 kmA2LAShares 2 accredited test methodsASTM D3359ASTM G155
- ICC Evaluation ServiceElkhart, IN · ~320 kmA2LAShares 2 accredited test methodsASTM D3359ASTM G155
- Assured Testing ServicesRidgway, PA · ~397 kmA2LAShares 2 accredited test methodsASTM D3359ASTM G155
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.