MS Testing – a trading division of Mariner Systems (UK)
5 Maple Way, Aycliffe Industrial Park, Newton Aycliffe, DL5 6BF, Co Durham, United Kingdom
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at MS Testing – a trading division of Mariner Systems (UK)?
Claim this profile to keep it accurate.
Register record
- UKASRefreshed
- 4413Active
Accredited standards
19Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 60068 series
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
BS EN 60068-2-2:2007 A equipment and systems Constant/Cyclic IEC 60068-2-2:2007 BS EN 60945; BS EN 60068-2-1:2007 A Constant/Cyclic IEC 60068-2-1:2007 BS EN 60945; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 13628-6: 2006; ISO 13628-6: 2006 Min temp: - 40
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
BS EN 60068-2-2:2007 A equipment and systems Constant/Cyclic IEC 60068-2-2:2007 BS EN 60945; BS EN 60068-2-1:2007 A Constant/Cyclic IEC 60068-2-1:2007 BS EN 60945; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 13628-6: 2006; ISO 13628-6: 2006 Min temp: - 40
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
BS EN 60068-2-6:1996 A Sinusoidal BS EN 60068-2-6:2008; BS EN 60945; BS EN 60068-2-64:2008; BS EN 60068-2-64:2019 Freq range: 2 to 3000 Hz IEC 60068-2-64:2019 Max pk/pk displacement: ISO 13628-6: 2006; BS EN 60068-2-27:1993
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
BS EN 60068-2-30:2005 Test Db Humidity range: BS EN 60068-2-78:2002 10; BS EN 60068-2-78:2013; BS EN 60945; BS EN 60945:2002; BS EN 60068-2-14:2009 BS EN 60068-2-14:2023 Na Shock Nb Cycle Nc Fluid bath Max temp: 80ºC Min temp: -30ºC Max chamber size: 990 x 1080 x 1080
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
BS EN 60068-2-6:1996 A Sinusoidal BS EN 60068-2-6:2008; BS EN 60945; BS EN 60068-2-64:2008; BS EN 60068-2-64:2019 Freq range: 2 to 3000 Hz IEC 60068-2-64:2019 Max pk/pk displacement: ISO 13628-6: 2006; BS EN 60068-2-27:1993
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
BS EN 60068-2-30:2005 Test Db Humidity range: BS EN 60068-2-78:2002 10; BS EN 60068-2-78:2013; BS EN 60945; BS EN 60945:2002; BS EN 60068-2-14:2009 BS EN 60068-2-14:2023 Na Shock Nb Cycle Nc Fluid bath Max temp: 80ºC Min temp: -30ºC Max chamber size: 990 x 1080 x 1080
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidanceCertificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.
BS EN 60068-2-6:1996 A Sinusoidal BS EN 60068-2-6:2008; BS EN 60945; BS EN 60068-2-64:2008; BS EN 60068-2-64:2019 Freq range: 2 to 3000 Hz IEC 60068-2-64:2019 Max pk/pk displacement: ISO 13628-6: 2006; BS EN 60068-2-27:1993
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
BS EN 60068-2-30:2005 Test Db Humidity range: BS EN 60068-2-78:2002 10; BS EN 60068-2-78:2013; BS EN 60945; BS EN 60945:2002; BS EN 60068-2-14:2009 BS EN 60068-2-14:2023 Na Shock Nb Cycle Nc Fluid bath Max temp: 80ºC Min temp: -30ºC Max chamber size: 990 x 1080 x 1080
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60945; IEC 61000-3-2
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60947-2; IEC 60945; IEC 61000-4-2
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60945; IEC 61000-4-3
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-11; IEC 60945
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC
IEC 60529Degrees of protection provided by enclosures (IP Code)
BS EN 60529:1992 A1; BS EN 60529:2013 Protected against solid IP1X A objects greater than 50 mm dia Protected against solid IP2X A objects greater than 12; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
BS EN 60068-2-2:2007 A equipment and systems Constant/Cyclic IEC 60068-2-2:2007 BS EN 60945; BS EN 60068-2-1:2007 A Constant/Cyclic IEC 60068-2-1:2007 BS EN 60945; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 13628-6: 2006; ISO 13628-6: 2006 Min temp: - 40
BS EN 60068-2-30:2005 Test Db Humidity range: BS EN 60068-2-78:2002 10; BS EN 60068-2-78:2013; BS EN 60945; BS EN 60945:2002; BS EN 60068-2-14:2009 BS EN 60068-2-14:2023 Na Shock Nb Cycle Nc Fluid bath Max temp: 80ºC Min temp: -30ºC Max chamber size: 990 x 1080 x 1080
BS EN 60068-2-6:1996 A Sinusoidal BS EN 60068-2-6:2008; BS EN 60945; BS EN 60068-2-64:2008; BS EN 60068-2-64:2019 Freq range: 2 to 3000 Hz IEC 60068-2-64:2019 Max pk/pk displacement: ISO 13628-6: 2006; BS EN 60068-2-27:1993
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60947-2; IEC 60945; IEC 61000-4-2
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60945; IEC 61000-4-3
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60945; IEC 61000-3-2
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-11; IEC 60945
IEC 60947-2Name not checked yet
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60947-2; IEC 60945; IEC 61000-4-2
Other standards
ISO 13628-6Petroleum and natural gas industries - Design and operation of subsea production systems - Part 6: Subsea production control systems
BS EN 60068-2-2:2007 A equipment and systems Constant/Cyclic IEC 60068-2-2:2007 BS EN 60945; BS EN 60068-2-1:2007 A Constant/Cyclic IEC 60068-2-1:2007 BS EN 60945; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 13628-6: 2006; ISO 13628-6: 2006 Min temp: - 40
BS EN 60068-2-6:1996 A Sinusoidal BS EN 60068-2-6:2008; BS EN 60945; BS EN 60068-2-64:2008; BS EN 60068-2-64:2019 Freq range: 2 to 3000 Hz IEC 60068-2-64:2019 Max pk/pk displacement: ISO 13628-6: 2006; BS EN 60068-2-27:1993
Scope as published by UKAS
10 lines
ISO/IEC 17025
Active4413
Location
5 Maple Way, Aycliffe Industrial Park, Newton Aycliffe, Co Durham, DL5 6BF, GB
54.68483, -1.77402
Open in MapsLabs with overlapping accredited scope in United Kingdom
- TUV SUD Limited (Trading as TUV SUD)Hampshire · ~426 kmUKASShares 4 accredited methods and materialsIEC 60945IEC 61000-4-11Air
- Eurofins Electrical & Electronic UKNorth Yorkshire · ~64 kmUKASShares 3 accredited methods and materialsIEC 60945AirWater
- Intertek Testing & CertificationEssex · ~357 kmUKASShares 3 accredited methods and materialsIEC 61000-6-1AirWater
- UL International (UK)Hampshire · ~406 kmUKASShares 3 accredited methods and materialsIEC 61000-4-11AirWater
- Cura Terrae OH and Emissions TestingWest Yorkshire · ~105 kmUKASShares 2 accredited materialsAirWater
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.