Compliance Management Group (CMG)
257 Simarano Drive, Suite 4, 01752-3070, Marlboro, MA, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Compliance Management Group (CMG)?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2316.01Active
- 2316.03Active
Certificates and scope
2ISO/IEC 17025
Active2316.01
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 2316.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Electrical Testing | ISO/IEC 17025:2017; ISO 10605; ISO 11452-4; ISO 7637-2; ISO 7637-3 Electrical Loads ISO 16750-2 Emissions Harmonics and Flicker EN 61000-3-2 | - | - |
| 2 | Electrical Testing | IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6 | - | - |
| 3 | Electrical Testing | IEC 61800-3; ANSI C63 | Electronic | to 18000 MHz |
| 4 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active2316.03
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 2316.03
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Electrical Testing | ISO/IEC 17025:2017; ISO 10605; ISO 11452-4; ISO 7637-2; ISO 7637-3 Electrical Loads ISO 16750-2 Emissions Harmonics and Flicker EN 61000-3-2 | - | - |
| 2 | Electrical Testing | IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6 | - | - |
| 3 | Electrical Testing | IEC 61800-3; ANSI C63 | Electronic | to 18000 MHz |
| 4 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Compliance WorldwideSandown, NH · ~30 kmA2LAShares 2 accredited methods and materialsANSI C63Electronic
- BUREAU VERITAS CONSUMER PRODUCTS SERVICESLittleton, MA · ~48 kmA2LAShares 2 accredited methods and materialsANSI C63Electronic
- CETECOMMilpitas, CA · ~4,307 kmA2LAShares 2 accredited methods and materialsANSI C63Electronic
- ATLAS Compliance & EngineeringSan Jose, CA · ~4,310 kmA2LAShares 2 accredited test methodsANSI C63IEC 61000-4-2
- Bay Area ComplianceSunnyvale, CA · ~4,316 kmA2LAShares 2 accredited test methodsANSI C63ISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.