Laboratorio controllo qualità acque e soluzioni per dialisi - U.O.C. Patologia Clinica - Dipartimento dei Servizi - AST Pesaro Urbino
Via Roma 54, 61049, Urbania, Italy
- Accredited standards
- 3
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 7899-2:2003; UNI EN ISO 6222:2001; UNI EN ISO 16266:2008; Rapporti ISTISAN 2007/05 pag 59 Met ISS A006A; Rapporti ISTISAN 2007/05 pag 22 Met ISS A001A; Rapporti ISTISAN 2007/05 pag 164 Met ISS A016B; MP-C22-01 2025 Rev. 7; MP-LAL-02 2025 Rev. 6
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
1 line
ISO/IEC 17025
Active00421
Accredited scope, certificate 00421
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 7899-2:2003; UNI EN ISO 6222:2001; UNI EN ISO 16266:2008; Rapporti ISTISAN 2007/05 pag 59 Met ISS A006A; Rapporti ISTISAN 2007/05 pag 22 Met ISS A001A; Rapporti ISTISAN 2007/05 pag 164 Met ISS A016B; MP-C22-01 2025 Rev. 7; MP-LAL-02 2025 Rev. 6 | Drinking water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- TENTAMUS AGRIPARADIGMARavenna · ~89 kmACCREDIAShares 2 accredited methods and materialsEN ISO 7899-2:2003Drinking water
- ECOPRISMAPrato · ~119 kmACCREDIAShares 2 accredited methods and materialsEN ISO 7899-2:2003Drinking water
- ALFA SolutionsReggio Emilia · ~189 kmACCREDIAShares 2 accredited methods and materialsEN ISO 7899-2:2003Drinking water
- Hygeia Lab SrlRoma · ~209 kmACCREDIAShares 2 accredited methods and materialsEN ISO 7899-2:2003Drinking water
- BIOSICThiene · ~242 kmACCREDIAShares 2 accredited methods and materialsEN ISO 7899-2:2003Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.