FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United Kingdom

NPL Management

National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, Middlesex, United Kingdom

UKAS|0002ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
11
Standards
19
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at NPL Management?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
0002Active

Accredited standards

19

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
As written on the certificate · Line 7 (UKAS 0002)

BS EN ISO 23210:2009; BS EN ISO 21877:2019; BS EN 15259:2007 Total Particulate Matter BS EN 13284-1:2017; BS EN 1911:2010; BS EN 14791:2017

EN 12341Name not checked yet
As written on the certificate · Line 4 (UKAS 0002)

BS EN 12341:2014; BS EN 16909:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; in-house method QPAS/B/564

EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
As written on the certificate · Line 9 (UKAS 0002)

BS EN ISO 21258:2010; BS EN 15259:2007; BS EN 14792:2017; BS EN 14789:2017; BS EN 12619:2013

EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
As written on the certificate · Line 6 (UKAS 0002)

BS EN ISO 23210:2009; BS EN 13284-1:2017; BS EN 15259:2007 Ammonia US EPA Method 26; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 23210:2009

As written on the certificate · Line 7 (UKAS 0002)

BS EN ISO 23210:2009; BS EN ISO 21877:2019; BS EN 15259:2007 Total Particulate Matter BS EN 13284-1:2017; BS EN 1911:2010; BS EN 14791:2017

EN 14181Stationary source emissions - Quality assurance of automated measuring systems
As written on the certificate · Line 2 (UKAS 0002)

BS EN 14181:2014; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; in-house Method QPLM/B/216

EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
As written on the certificate · Line 9 (UKAS 0002)

BS EN ISO 21258:2010; BS EN 15259:2007; BS EN 14792:2017; BS EN 14789:2017; BS EN 12619:2013

EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
As written on the certificate · Line 8 (UKAS 0002)

BS EN ISO 16911-1:2013; BS EN 15259:2007; BS EN 14790:2017; BS EN 15058:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2

EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
As written on the certificate · Line 7 (UKAS 0002)

BS EN ISO 23210:2009; BS EN ISO 21877:2019; BS EN 15259:2007 Total Particulate Matter BS EN 13284-1:2017; BS EN 1911:2010; BS EN 14791:2017

EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
As written on the certificate · Line 9 (UKAS 0002)

BS EN ISO 21258:2010; BS EN 15259:2007; BS EN 14792:2017; BS EN 14789:2017; BS EN 12619:2013

EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
As written on the certificate · Line 8 (UKAS 0002)

BS EN ISO 16911-1:2013; BS EN 15259:2007; BS EN 14790:2017; BS EN 15058:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2

EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
As written on the certificate · Line 2 (UKAS 0002)

BS EN 14181:2014; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; in-house Method QPLM/B/216

As written on the certificate · Line 3 (UKAS 0002)

BS EN 16911-2; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 16017-1; ISO/IEC 17025

As written on the certificate · Line 6 (UKAS 0002)

BS EN ISO 23210:2009; BS EN 13284-1:2017; BS EN 15259:2007 Ammonia US EPA Method 26; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 23210:2009

As written on the certificate · Line 7 (UKAS 0002)

BS EN ISO 23210:2009; BS EN ISO 21877:2019; BS EN 15259:2007 Total Particulate Matter BS EN 13284-1:2017; BS EN 1911:2010; BS EN 14791:2017

As written on the certificate · Line 8 (UKAS 0002)

BS EN ISO 16911-1:2013; BS EN 15259:2007; BS EN 14790:2017; BS EN 15058:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2

As written on the certificate · Line 9 (UKAS 0002)

BS EN ISO 21258:2010; BS EN 15259:2007; BS EN 14792:2017; BS EN 14789:2017; BS EN 12619:2013

As written on the certificate · Line 10 (UKAS 0002)

BS EN ISO 16911-1:2013; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 16911-1:2013; IEC 17025

EN 16909Name not checked yet
As written on the certificate · Line 4 (UKAS 0002)

BS EN 12341:2014; BS EN 16909:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; in-house method QPAS/B/564

EN 16911-2Name not checked yet
As written on the certificate · Line 3 (UKAS 0002)

BS EN 16911-2; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 16017-1; ISO/IEC 17025

ISO

ISO 16017-1Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling
As written on the certificate · Line 3 (UKAS 0002)

BS EN 16911-2; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 16017-1; ISO/IEC 17025

ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
As written on the certificate · Line 8 (UKAS 0002)

BS EN ISO 16911-1:2013; BS EN 15259:2007; BS EN 14790:2017; BS EN 15058:2017; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2

As written on the certificate · Line 10 (UKAS 0002)

BS EN ISO 16911-1:2013; BS EN 15259:2007; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 16911-1:2013; IEC 17025

ISO 21258Stationary source emissions - Determination of the mass concentration of dinitrogen monoxide (N2O) - Reference method: Non-dispersive infrared method
As written on the certificate · Line 9 (UKAS 0002)

BS EN ISO 21258:2010; BS EN 15259:2007; BS EN 14792:2017; BS EN 14789:2017; BS EN 12619:2013

ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
As written on the certificate · Line 7 (UKAS 0002)

BS EN ISO 23210:2009; BS EN ISO 21877:2019; BS EN 15259:2007 Total Particulate Matter BS EN 13284-1:2017; BS EN 1911:2010; BS EN 14791:2017

ISO 23210Stationary source emissions - Determination of PM10/PM2,5 mass concentration in flue gas - Measurement at low concentrations by use of impactors
As written on the certificate · Line 6 (UKAS 0002)

BS EN ISO 23210:2009; BS EN 13284-1:2017; BS EN 15259:2007 Ammonia US EPA Method 26; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 23210:2009

As written on the certificate · Line 7 (UKAS 0002)

BS EN ISO 23210:2009; BS EN ISO 21877:2019; BS EN 15259:2007 Total Particulate Matter BS EN 13284-1:2017; BS EN 1911:2010; BS EN 14791:2017

Other standards

EPA 26Name not checked yet
As written on the certificate · Line 6 (UKAS 0002)

BS EN ISO 23210:2009; BS EN 13284-1:2017; BS EN 15259:2007 Ammonia US EPA Method 26; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 23210:2009

Scope as published by UKAS

11 lines
UKAS

ISO/IEC 17025

Active

0002

View scope

Location

National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, GB

51.54606, -0.25378

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.