UK Grid Solutions
UK Grid Solutions, Grid Automation Laboratories, St Leonards Building, Redhill Business Park, ST16 1WT, Stafford, United Kingdom
Visit website- Accredited standards
- 5
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60255-11
IEC 60255-26
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61850-10
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60068-2-14
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-11; IEC 60255-11; IEC 60255-26
ISO/IEC 17025:2017 UK Grid Solutions Limited Issue No: 027 Issue date: 06 August 2025 UK Grid Solutions Grid Automation Laboratories St Leonards Building Redhill Business Park Stafford ST16 1; IEC 17025; IEC 60255-26
BS EN 61850-10:2013 BS EN 61850-10:2005; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61850
Read from the scope as published by UKAS. Register refreshed 2026-11-06.
Scope as published by UKAS
5 lines
ISO/IEC 17025
Active4085
Accredited scope, certificate 4085
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 UK Grid Solutions Limited Issue No: 027 Issue date: 06 August 2025 UK Grid Solutions Grid Automation Laboratories St Leonards Building Redhill Business Park Stafford ST16 1; IEC 17025; IEC 60255-26 | Air | to 1000 A/m |
| 2 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-11; IEC 60255-11; IEC 60255-26 | Measuring Relays, Protection Devices and ancillary equipment | to 5 kV |
| 3 | BS EN 61850-10:2013 BS EN 61850-10:2005; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61850 | Substation automation products with IEC 61850 communication functions | - |
| 4 | BS EN 61850-10:2013 BS EN 61850-10:2005; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61850 | Substation automation products with IEC 61850 communication functions | - |
| 5 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60068-2-14 | Measuring Relays, Protection Devices and ancillary equipment | -40 to 85 oC |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
UK Grid Solutions, Grid Automation Laboratories, St Leonards Building, Redhill Business Park, Stafford, ST16 1WT, GB
52.80632, -2.11638
Open in MapsLabs with overlapping accredited scope in United Kingdom
- TUV SUD Limited (Trading as TUV SUD)Hampshire · ~224 kmUKASShares 2 accredited test methodsIEC 60068-2-14IEC 61000-4-11
- Cranage EMC TestingShropshire · ~28 kmUKASShares 1 accredited test methodIEC 61000-4-11
- UL International (UK)Hampshire · ~184 kmUKASShares 1 accredited test methodIEC 61000-4-11
- MS Testing – a trading division of Mariner Systems (UK)Co Durham · ~203 kmUKASShares 1 accredited test methodIEC 61000-4-11
- Resonate TestingNorthern Ireland · ~318 kmUKASShares 1 accredited test methodIEC 60068-2-14
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.