MS Testing – a trading division of Mariner Systems (UK)
5 Maple Way, Aycliffe Industrial Park, Newton Aycliffe, DL5 6BF, Co Durham, United Kingdom
Visit website- Accredited standards
- 19
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 19 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series8
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 61000 series7
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC3
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 60947-2
Other standards1
ISO 13628-6Petroleum and natural gas industries - Design and operation of subsea production systems - Part 6: Subsea production control systems
BS EN 60068-2-2:2007 A equipment and systems Constant/Cyclic IEC 60068-2-2:2007 BS EN 60945; BS EN 60068-2-1:2007 A Constant/Cyclic IEC 60068-2-1:2007 BS EN 60945; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 13628-6: 2006; ISO 13628-6: 2006 Min temp: - 40
BS EN 60068-2-6:1996 A Sinusoidal BS EN 60068-2-6:2008; BS EN 60945; BS EN 60068-2-64:2008; BS EN 60068-2-64:2019 Freq range: 2 to 3000 Hz IEC 60068-2-64:2019 Max pk/pk displacement: ISO 13628-6: 2006; BS EN 60068-2-27:1993
BS EN 60068-2-30:2005 Test Db Humidity range: BS EN 60068-2-78:2002 10; BS EN 60068-2-78:2013; BS EN 60945; BS EN 60945:2002; BS EN 60068-2-14:2009 BS EN 60068-2-14:2023 Na Shock Nb Cycle Nc Fluid bath Max temp: 80ºC Min temp: -30ºC Max chamber size: 990 x 1080 x 1080
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60945; IEC 61000-3-2
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60947-2; IEC 60945; IEC 61000-4-2
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 60945; IEC 61000-4-3
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-11; IEC 60945
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
BS EN 60529:1992 A1; BS EN 60529:2013 Protected against solid IP1X A objects greater than 50 mm dia Protected against solid IP2X A objects greater than 12; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025
Read from the scope as published by UKAS. Register refreshed 2026-11-20.
Scope as published by UKAS
10 lines
ISO/IEC 17025
Active4413
Location
5 Maple Way, Aycliffe Industrial Park, Newton Aycliffe, Co Durham, DL5 6BF, GB
54.60087, -1.56887
Open in MapsLabs with overlapping accredited scope in United Kingdom
- TUV SUD Limited (Trading as TUV SUD)Hampshire · ~415 kmUKASShares 2 accredited test methodsIEC 60945IEC 61000-4-11
- Eurofins Electrical & Electronic UKCastleford · ~99 kmUKASShares 1 accredited test methodIEC 60945
- Cranage EMC TestingShropshire · ~199 kmUKASShares 1 accredited test methodIEC 61000-4-11
- UL International (UK)Hampshire · ~371 kmUKASShares 1 accredited test methodIEC 61000-4-11
- Intertek Testing & CertificationLeatherhead · ~376 kmUKASShares 1 accredited test methodIEC 61000-6-1
Accreditation data refreshed from the UKAS register on .