Registers refreshed 2026-11-20.See refresh dates
Mexico

Sistemas y Basculas de Mexico S.A. de

Calle Miguel Palacios # 5570, Cd. Juarez Chihuahua, 32390, Mexico, Cd. Juarez Chihuahua, Mexico

Visit website
A2LA 3063.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM E617Standard Specification for Laboratory Weights and Precision Mass Standards

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

3063.01

The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3063.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 220 g
2ASTM E617-to 5 kg
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3063.01) 10/8/2024 Page 3 of 4 Parameter/Equipment Range CMC2 (±) Comments Industrial Scales/Bench Scales3 (cont.) – Resolution: 0.0002 lb 0.0005 lb 0.001 lb 0.002 lb 0.005 lb 0.01 lb Up to 0.1250 lb (> 0.1250 to 0.5) lb (> 0.5 to 1) lb (> 1 to 1.5) lb (> 1.5 to 2) lb Up to 0.1250 lb (> 0.1250 to 1.25) lb (> 1.25 to 2.5) lb (> 2.5 to 4) lb (> 4 to 5) lb Up to 0.125 lb (> 0.125 to 2.5) lb (> 2.5 to 5) lb (> 5 to 7.5) lb (> 7.5 to 10) lb Up to 0.250 lb (> 0.250 to 5) lb (> 5 to 10) lb (> 10 to 15) lb (> 15 to 20) lb Up to 0.250 lb (> 0.250 to 12) lb (> 12 to 25) lb (> 25 to 35) lb (> 35 to 50) lb Up to 0.25 lb (> 0.25 to 25) lb (> 25 to 50) lb (> 50 to 75) lb (> 75 to 100) lb 0.000 13 lb 0.000 18 lb 0.000 23 lb 0.000 34 lb 0.000 28 lb 0.000 32 lb 0.000 41 lb 0.000 49 lb 0.0006 lb 0.0007 lb 0.000 65 lb 0.000 75 lb 0.0009 lb 0.0012 lb 0.0014 lb 0.0013 lb 0.0014 lb 0.0018 lb 0.0023 lb 0.0028 lb 0.0032 lb 0.0036 lb 0.0044 lb 0.0054 lb 0.0071 lb 0.0064 lb 0.0071 lb 0.009 lb 0.011 lb 0.014 lb NIST Class F weights
to 100 lb
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3063.01) 10/8/2024 Page 4 of 4 Parameter/Equipment Range CMC2 (±) Comments Floor Scales3 – Resolution: 0.01 lb 0.02 lb 0.05 lb 0.1 lb 0.2 lb 0.5 lb Up to 0.25 lb (> 0.25 to 25) lb (> 25 to 50) lb (> 50 to 75) lb (> 75 to 100) lb Up to 0.50 lb (> 0.50 to 50) lb (> 50 to 100) lb (> 100 to 150) lb (> 150 to 200) lb Up to 75 lb (> 75 to 250) lb (> 250 to 500) lb Up to 250 lb (> 250 to 500) lb (> 500 to 1000) lb Up to 500 lb (> 500 to 1000) lb (> 1000 to 2000) lb Up to 500 lb (> 500 to 1000) lb (> 1000 to 5000) lb 0.0064 lb 0.0071 lb 0.009 lb 0.011 lb 0.014 lb 0.013 lb 0.014 lb 0.018 lb 0.023 lb 0.028 lb 0.034 lb 0.045 lb 0.071 lb 0.072 lb 0.090 lb 0.14 lb 0.14 lb 0.18 lb 0.19 lb 0.33 lb 0.35 lb 0.90 lb NIST Class F weights ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
to 5000 lb
5ISO/IEC 17025: 2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Calle Miguel Palacios # 5570, Cd. Juarez Chihuahua, 32390, Mexico, Cd. Juarez Chihuahua, MX

31.73649, -106.42662

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.