Registers refreshed 2026-11-20.See refresh dates
Mexico

Analisis por Instrumentos y Software para CMM's SA de CV., dba Soporte Metrology

27 Poniente 507, interior 103, Colonia Chulavista, Puebla, Puebla, 72420, Mexico, Puebla, Puebla, Mexico

Visit website
A2LA 3006.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
7
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 7 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 230-2Test code for machine tools - Part 2: Determination of accuracy and repeatability of positioning of numerically controlled axes
ISO 230-6Test code for machine tools - Part 6: Determination of positioning accuracy on body and face diagonals (Diagonal displacement tests)
ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode
ISO 10360-8Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 8: CMMs with optical distance sensors
ISO 10360-12Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 12: Articulated arm coordinate measurement machines (CMM)
ISO 10360-13Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 13: Optical 3D CMS

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

3006.01

The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-08-05. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3006.01

LineMethodMatrixRange
1ISO 10360-2; ASME B89.4.10360.2; ISO 10360-5:2010; ISO 10360-5:2020-to 18000 mm
2ISO 230-2; ISO 230-6; ASME B89.4.22; ISO 10360-12; VDI/VDE 2634-3-to 18000 mm
3-Checking Fixtures & Workpieces
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3006.01) Revised 1/15/2026 Page 3 of 7 II. Dimensional Testing/Calibration1 Parameter/Equipment Range CMC2, 4, 9 (±) Comments Dimensional Measurements8 Checking Fixtures & Workpieces X, Y, Z: Up to (2600, 1500, 1400) mm Up to (900, 1500, 700) mm (11 + 5.9L) μm (2.2 + 6L) μm ASME Y14.5: CMM used as reference III. Dimensional Testing1 Parameter/Equipment Range Comments 3D Measurement3, 7, 9 Distances and 3D Measurements3, 7, 9 Up to 3700 mm Up to 80 000 mm ASME Y14.5: articulated arm CMM used with tactile probing and/or laser scanning Laser tracker used as reference
to 80000 mm
4ASME B89.4.22; ISO 10360-12; ISO 10360-8--
5VDI/VDE 2634-3; ISO 10360-13test sphere; ball cubeto 700 mm
6-Sensor Measurement Volume
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3006.01) Revised 1/15/2026 Page 6 of 7 Parameter/Equipment Range CMC2, 4 (±) Comments Optical 3D Coordinate Measuring Systems cont. Distortion Error Distortion Error in Sensor Measurement Volume (Single View) D CC.SMV.SV:O3D) Distortion Error in Sensor Measurement Volume (Multiple View) D CC.SMV.MV:O3D) Distortion Error Flat-Form Distortion Error 100% (Single View) (DForm.Pla.All:SMV.SV:O3D) Flat-Form Distortion Error 100% (Multiple View) (D Form.Pla.All:SMV.MV:O3D) Flat-Form Distortion Error 95% (Single View) (DForm.Pla.95%:SMV.SV:O3D) Flat-Form Distortion Error 95% (Multiple View) (DForm.Pla.95%:SMV.MV:O3D) Volumetric Length Measurement Error Bi-directional Length Measurement Error in Concatenated Measurement Volume in Multiple View. (E Vol:CMV.MV:O3D) Up to 700 mm Up to 700 mm Up to 900 mm Up to 900 mm Up to 900 mm Up to 900 mm Up to 3000 mm 1.6 µm 1.6 µm 6.4 µm 7.3 µm 6.3 µm 7.2 µm (1.4 + 7L) µm Ball Cube Ball Cube Test Plane Test Plane Test Plane Test Plane Ball Bar
to 3000 mm
7ASME Y14.5; ASME B89.4.22Checking Fixtures and Workpiecesto 1200 mm
8ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

27 Poniente 507, interior 103, Colonia Chulavista, Puebla, Puebla, 72420, Mexico, Puebla, Puebla, MX

19.04372, -98.19815

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .