7layers
Borsigstraße 11, 40880, Ratingen, Germany
Visit website- Accredited standards
- 141
- DAKKS certificates
- 6
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 141 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI102
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 296
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-2
ETSI EN 300 422-3
ETSI EN 300 422-4
ETSI EN 300 440
Show all 102
ETSI EN 300 609-4
ETSI EN 301 087
ETSI EN 301 091-1
ETSI EN 301 091-2
ETSI EN 301 357
ETSI EN 301 419-1
ETSI EN 301 419-2
ETSI EN 301 419-3
ETSI EN 301 419-7
ETSI EN 301 420
ETSI EN 301 441
ETSI EN 301 442
ETSI EN 301 489-1
ETSI EN 301 489-2
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-6
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-20
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-51
ETSI EN 301 489-52
ETSI EN 301 502
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-3
ETSI EN 301 908-11
ETSI EN 301 908-13
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3-1
ETSI EN 302 208
ETSI EN 302 264-1
ETSI EN 302 264-2
ETSI EN 302 372
ETSI EN 302 502
ETSI EN 302 567
ETSI EN 302 571
ETSI EN 302 729
ETSI EN 302 858
ETSI EN 302 858-1
ETSI EN 303 340
ETSI EN 303 345-1
ETSI EN 303 345-2
ETSI EN 303 345-3
ETSI EN 303 345-4
ETSI EN 303 345-5
ETSI EN 303 396
ETSI EN 303 406
ETSI EN 303 417
ETSI EN 303 446-1
ETSI EN 303 446-2
ETSI EN 303 447
ETSI EN 303 645
ETSI EN 303 661
ETSI EN 303 687
ETSI EN 303 883-1
ETSI EN 303 883-2
ETSI EN 305 550-1
ETSI EN 305 550-2
ETSI ETS 300 609-1
ETSI TS 101 087
ETSI TS 101 789-1
ETSI TS 102 230-1
ETSI TS 102 384
ETSI TS 102 933-1
ETSI TS 102 933-2
ETSI TS 102 936-1
ETSI TS 102 936-2
ETSI TS 103 412
ETSI TS 103 428
ETSI TS 103 543
ETSI TS 103 701
ETSI TS 103 732-1
ETSI TS 103 732-2
ETSI TS 103 732-3
ETSI TS 126 269
ETSI TS 134 114
ETSI TS 136 124
ETSI TS 138 124
ETSI TS 151 010-1
ETSI TS 151 010-2
ETSI TS 151 010-4
ETSI TS 151 010-5
IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-8
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61326 series6
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
EN4
EN 16454
EN 17240
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50364
IEC4
IEC 62209-152
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62369-1
IEC 62443-4-2
Other standards4
ANSI C63.26
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
RSS-170
3GPP TS 25.141 R17 V17.0.0; ETSI TS 101 789 -1 V1.1.2; ETSI EN 300 220 -1 V3.1.1; ETSI EN 300 220 -2 V3.3.1; ETSI EN 300 220 -3-1 V2.1.1; ETSI EN 300 220 -3-2 V1.1.1; ETSI EN 300 220 -4 V1.1.1; ETSI EN 300 330 V2.1.1
ETSI EN 302 208 V3.4.1; ETSI EN 300 296 V2.2.1; ETSI EN 300 440 V2.2.1; ETSI EN 302 372 V2.1.1; ETSI EN 302 729 V2.1.1; ETSI EN 303 447 V1.3.1
ETSI EN 302 065 -3 V2.1.1 (2016-11); ETSI EN 302 065 -3-1 V3.2.1 (2025-02); ETSI EN 303 661 V1.1.1 (2024-05); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 301 893 V2.2.1 (2024-11); EN 303 687 V1.1.1 (2023-06); ETSI EN 302 502 V2.1.1 (2017-03)
ETSI EN 300 422 -2 V2.1.1 (2017-02); ETSI EN 300 422 -3 V2.1.1 (2017-02); ETSI EN 300 422 -4 V2.1.1 (2017-05); ETSI EN 301 357 V2.1.1 (2017-06); ETSI EN 305 550 -1 V1.2.1 (2014-10); ETSI EN 305 550 -2 V1.2.1 (2014-10); ETSI EN 305 550 V2.1.0 (2017-10)
ETS 300 609 -1; ETSI EN 300 609 -4; ETSI EN 301 087; ETSI TS 101 087; ETSI EN 301 502; 3GPP TS 11.21; ETSI EN 301 908 -1; ETSI EN 301 908 -3; ETSI EN 301 908 -11; 3GPP TS 25.104
ETSI EN 303 406 V1.1.1 (2017-02); ETSI EN 302 858 V2.1.1 (2016-12); ETSI EN 303 396 V1.1.1 (2016-12); ETSI EN 301 091 -1 V2.1.1 (2017-01); ETSI EN 301 091 -2 V2.1.1 (2017-01); ETSI EN 301 091 V1.1.1 (1998-06)
ETSI EN 301 419 -1 V4.1.1; ETSI EN 301 419 -2 V5.1.1; ETSI EN 301 419 -3 V5.0.2; ETSI EN 301 419 -7 V5.1.1; ETSI EN 301 420 V4.0.1; ETSI EN 301 511 V12.5.1
ETSI EN 301 441 V2.1.1 (2016-06); ETSI EN 301 442 V2.1.1 (2016-06); ETSI EN 302 571 V2.1.1 (2017-02); ETSI EN 303 417 V1.1.1 (2017-06); IEEE 1528 -2013; IEEE/IEC 62209 -1528-2020
DIN EN 61326 -2-5; VDE 0843-20-2-5; EN IEC 61326-2-5:2021; ETSI EN 301 489 -1 V2.2.3 (2019-11); ETSI EN 301 489 -2 V2.1.1 (2019-04); ETSI EN 301 489 -3 V2.3.2 (2023-01); ETSI EN 301 489 -5 V2.2.1 (2019-04); ETSI EN 301 489 -6 V2.2.1 (2019-04)
ETSI EN 301 489 -9 V2.1.1 (2019-04); ETSI EN 301 489 -17 V3.3.1 (2024-09); ETSI EN 301 489 -19 V2.2.1 (2022-09); ETSI EN 301 489 -20 V2.2.1 (2021-11); ETSI EN 301 489 -33 V2.2.1 (2019-04); ETSI EN 301 489 -34 V2.1.1 (2019-04)
ETSI EN 301 489-50 V2.3.1; ETSI EN 301 489-51 V2.1.1; ETSI EN 301 489-52 V1.3.1; 3GPP TS 25.113 V18.0.0; 3GPP TS 34.124 V18.00; ETSI TS 136 124 V18.0.0; 3GPP TS 36.124 V18.0.0
3GPP TS 51.010-5 V10.21.0; ETSI TS 151 010-5 V10.20.0; PTCRB Bearer -Agnostic TTY Test Specification RFT 062 V2.0; ETSI EN 301 908-1 V15.2.1; ETSI EN 301 908-2 V13.1.1; ETSI EN 301 908-13 V13.3.1; 3GPP TS 25.101 V18.0.0; 3GPP TS 26.131 V18.1.0
ETSI EN 302 264 -1 V1.1.1 (2009-06); ETSI EN 302 264 -2 V1.1.1 (2009-06); ETSI EN 302 264 V2.1.1 (2017-05); ETSI EN 303 883 V1.1.1 (2016-09); ETSI EN 303 883 -1 V2.1.1 (2024-08); ETSI EN 303 883 -2 V2.1.1 (2024-08); ETSI EN 302 065 -1 V2.1.1 (2016-11); ETSI EN 302 065 -2 V2.1.1 (2016-11)
ETSI EN 302 567 V2.1.1; ETSI EN 303 340 V1.2.1; ETSI EN 303 345 -1 V1.1.1; ETSI EN 303 345 -2 V1.2.1; ETSI EN 303 345 -3 V1.1.1; ETSI EN 303 345 -4 V1.1.1; ETSI EN 303 345 -5 V1.2.1; ETSI EN 302 858 -1 V1.3.1
3GPP TS 38.124 V18.1.0 (2024-01); ETSI TS 138 124 V18.1.0 (2024-05); ETSI EN 303 446 -1 V1.2.1 (2019-10); ETSI EN 303 446 -2 V1.2.1 (2019-10); ANSI C63.4 2014 (2014-06); ANSI C63.4a 2017 (2017); AS/NZS 61000.6.3 2021 (2021-10)
ETSI TS 103 701 V1.1.1; ETSI EN 303 645 V2.1.1; BSI TR-03173; CTIA: Cybersecurity Certification Test Plan for IoT Devices V2.1.1; CTIA: Cybersecurity Certification Test Plan for IoT Devices V2.1.2; ETSI TS 103 732 V1.1.1; ETSI TS 103 732-1 V2.1.2
3GPP TS 26.132; ETSI TS 102 230 -1; 3GPP TS 31.120; 3GPP TS 31.121; 3GPP TS 31.122; 3GPP TS 31.124; 3GPP TS 34.108; 3GPP TS 34.109; 3GPP TS 34.121 -1
3GPP TS 34.229 -3; 3GPP TS 37.571 -1; 3GPP TS 37.571 -2; 3GPP TS 37.571 -3; 3GPP TS 37.571 -4; 3GPP TS 37.571 -5; 3GPP TR 37.901; ETSI TS 102 384; ETSI TS 102 933 -1; ETSI TS 102 933 -2
EN 16454: 2023; ETSI TS 102 936 -1 2011-04; ETSI TS 102 936 -2 2011-04; ETSI TS 126 269 V18.0.0 (2024-05); ETSI TS 103 412 V1.3.1 (2020-03); ETSI TS 103 428 V1.2.2 (2021-04); ETSI TS 103 543 V1.1.1 (2018-02); GOST 33467 (2015); GOST 33470 (2015); GOST 33471 (2015); ESMA UAE.S 5019 2024 (2024)
ETSI TS 103 732-2; ETSI TS 103 732-3; IEC 62443-4-2:2019; prEN 18031-1:2023 (E); prEN 18031-2:2023 (E); prEN 18031-3:2023 (E)
OMA-ETS-LightweightM2M Version 1.0.2; OMA-ETS-MMS_INT 15 Oct 2010; CTIA 01.01 Version 6.0.6, June 2025; CTIA 01.20 Version 6.0.4, April 2025; CTIA 01.50 Version 6.0.5, June 2025; CTIA 01.70 Version 6.0.3, December 2024; CTIA 01.71 Version 6.0.1, June 2024; CTIA 01.72 Version 6.0.1, September 2023; CTIA 01.73 Version 6.0.4, November 2023; CTIA 01.90 Version 6.0.2, April 2025; CTIA 01.03 Version 6.0.4, June 2025; 3GPP TS 34.114 V12.2.0 (2016-09); ETSI TS 134 114 V12.2.0 (2016-11); VF Ant. Req. V5.4
3GPP TS 51.010-1; ETSI TS 151 010-1; 3GPP TS 51.010-2; ETSI TS 151 010-2; 3GPP TS 51.010-4; ETSI TS 151 010-4
DIN EN 61000-4-6; VDE 847-4-6; DIN EN 61000-4-8; VDE 847-4-8; DIN EN 61000-4-9; VDE 847-4-9; DIN EN 61000-4-11; VDE 847-4-11; DIN EN 61000-3-2; VDE 838-2; DIN EN 61000-3-3; VDE 838-3
HKCA 1066 ISSUE 1 NOVEMBER 2013; HKCA 1073 ISSUE 1 JANUARY 2015; HKCA 1075 ISSUE 2 SEPTEMBER 2018; HKCA 1080 ISSUE 1 AUGUST 2018; HKCA 1081 ISSUE 1 APRIL 2022; DIN EN 61000 -4-2; VDE 847-4-2 2009-12 (2009-12); DIN EN 61000 -4-3; VDE 847-4-3 2021-11 (2021-11); DIN EN 61000 -4-4; VDE 847-4-4 2013-04 (2013-04); DIN EN 61000 -4-5; VDE 847-4-5 2021-04 (2021-04)
ISO 7637-2; ISO 7637-3; CISPR 16-2-1; CISPR 16-2-3; CISPR 16-2-4; CISPR 11; DIN EN IEC 61000-6-1; VDE 0839-6-1; DIN EN IEC 61000-6-2; VDE 0839-6-2
DIN EN IEC 61000-6-3; VDE 0839-6-3; DIN EN IEC 61000-6-4; VDE 0839-6-4; EN IEC 61000-6-8; DIN EN IEC 61000-6-8; VDE 0839-6-8; DIN EN 50130-4; VDE 0830-1-4; DIN EN 55011; VDE 0875-11; DIN EN 55014-1; VDE 0875-14-1; CISPR 14.1
DIN EN 55014 -2; VDE 0875-14-2; CISPR 14.2; DIN EN 55024; VDE 0878-24; CISPR 24: 2010+AMD1:2015; DIN EN 55032; VDE 0878-32; CISPR 32; DIN EN 55035; VDE 0878-35; EN 55035; CISPR 35; DIN EN 61326 -1; VDE 0843-20-1
EN IEC 61326 -1; IEC 61326 -1 Edition 3.0; DIN EN 61326 -2-1; VDE 0843-20-2-1; DIN EN 61326 -2-2; VDE 0843-20-2-2; DIN EN 61326 -2-3; VDE 0843-20-2-3; DIN EN 61326 -2-4; VDE 0843-20-2-4
LoRa Alliance End -Device Certification Radiated RF Performance For US 915 MHz ISM Band Devices v1.1; LoRa Alliance End -Device Certification Radiated RF Performance for South Korea 920-923 MHz ISM Band Devices v1.1.1; LoRaWAN 1.0.4 End Device Certification Requirements for All Regions; LoRaWAN 1.0.4 End Device Certification Class B Certification Specification; LoRaWAN 1.0.4 End Device Certification Class C Certification; LoRaWAN End Device Specification for SCHC Certification; LoRaWAN End -Device RF Performance measurements for All Regions; SIGFOX certification for End Products Test Specification for certification labs Rev1.1 (2016/08/26); DIN EN 16454 2015-12; DIN EN 16454: 2024-03; EN 16454 2015
TRA TS041 2.0; SASO 2944 (2023); 2017/79/AB (2018); CEN TS 17240 (31.12.2018) 2018; EN 17240 (6 October 2024) 2024; TS.11 v42.0; TS.37 V9.0; TS.39 V7.0; TS.40 V8.0; TS.42 v6.0; OMA -TS -LightweightM2M 1.1 (2018-07-10)
EN 62369-1; EN 50364; DIN EN IEC 62311; EN IEC 62311; ANSI C63.10; ANSI C63.10 -2020 +Cor.1-2023; ANSI C63.10a; ANSI C63.26
ANSI C 63.10-2013; ANSI C 63.10-2020; ANSI C63.10-2020/Cor 1-2023; ANSI/TIA-603-E-2016; ANSI/TIA-102.CAAA-E-2016; ANSI C63.26-2015; KDB Publication 971168
ANSI/TIA-603-E-2016; ANSI/TIA-102.CAAA-E-2016; ANSI C63.26-2015; KDB Publication 971168; KDB Publication 940660; ANSI C63.26-2015; KDB Publication 653005; ANSI C63.26-2015; KDB Publication 935210 D03; KDB Publication 935210 D04; KDB Publication 935210 D05
RSS -135; RSS -137; RSS -139; RSS -140; RSS -142; RSS-170; RSS-191; RSS -192; RSS -195; RSS -197
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
64 lines
ISO/IEC 17025
ActiveD-PL-12140-01-00
ISO/IEC 17025
ActiveD-PL-12140-01-01
ISO/IEC 17025
ActiveD-PL-12140-01-02
ISO/IEC 17025
ActiveD-PL-12140-01-03
ISO/IEC 17025
ActiveD-PL-12140-01-04
ISO/IEC 17025
ActiveD-PL-12140-01-05
Location
Labs with overlapping accredited scope in Germany
- TÜV NORD Hochfrequenztechnik GmbH & Co. KGKöln · ~39 kmDAKKSShares 2 accredited test methodsANSI C63.26-2015RSS-170
- PHOENIX TESTLABBlomberg · ~171 kmDAKKSShares 1 accredited test methodANSI C63.26-2015
- IBL-LabSt. Ingbert · ~226 kmDAKKSShares 1 accredited test methodANSI C63.26-2015
- TÜV SÜD Product ServiceMünchen · ~488 kmDAKKSShares 1 accredited test methodANSI C63.26-2015
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.