Registers refreshed 2026-11-20.See refresh dates
Germany

7layers

Borsigstraße 11, 40880, Ratingen, Germany

Visit website
DAKKS D-PL-12140-01-00DAKKS D-PL-12140-01-01DAKKS D-PL-12140-01-02and 3 moreISO/IEC 17025Register refreshed 2026-11-20
Part of the Bureau Veritas group: 82 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
141
DAKKS certificates
6
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 141 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI102
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 296
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-2
ETSI EN 300 422-3
ETSI EN 300 422-4
ETSI EN 300 440
Show all 102
ETSI EN 300 609-4
ETSI EN 301 087
ETSI EN 301 091-1
ETSI EN 301 091-2
ETSI EN 301 357
ETSI EN 301 419-1
ETSI EN 301 419-2
ETSI EN 301 419-3
ETSI EN 301 419-7
ETSI EN 301 420
ETSI EN 301 441
ETSI EN 301 442
ETSI EN 301 489-1
ETSI EN 301 489-2
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-6
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-20
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-51
ETSI EN 301 489-52
ETSI EN 301 502
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-3
ETSI EN 301 908-11
ETSI EN 301 908-13
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3-1
ETSI EN 302 208
ETSI EN 302 264-1
ETSI EN 302 264-2
ETSI EN 302 372
ETSI EN 302 502
ETSI EN 302 567
ETSI EN 302 571
ETSI EN 302 729
ETSI EN 302 858
ETSI EN 302 858-1
ETSI EN 303 340
ETSI EN 303 345-1
ETSI EN 303 345-2
ETSI EN 303 345-3
ETSI EN 303 345-4
ETSI EN 303 345-5
ETSI EN 303 396
ETSI EN 303 406
ETSI EN 303 417
ETSI EN 303 446-1
ETSI EN 303 446-2
ETSI EN 303 447
ETSI EN 303 645
ETSI EN 303 661
ETSI EN 303 687
ETSI EN 303 883-1
ETSI EN 303 883-2
ETSI EN 305 550-1
ETSI EN 305 550-2
ETSI ETS 300 609-1
ETSI TS 101 087
ETSI TS 101 789-1
ETSI TS 102 230-1
ETSI TS 102 384
ETSI TS 102 933-1
ETSI TS 102 933-2
ETSI TS 102 936-1
ETSI TS 102 936-2
ETSI TS 103 412
ETSI TS 103 428
ETSI TS 103 543
ETSI TS 103 701
ETSI TS 103 732-1
ETSI TS 103 732-2
ETSI TS 103 732-3
ETSI TS 126 269
ETSI TS 134 114
ETSI TS 136 124
ETSI TS 138 124
ETSI TS 151 010-1
ETSI TS 151 010-2
ETSI TS 151 010-4
ETSI TS 151 010-5
IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national

National versions in the same scope

AS/NZS 61000.6.3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-8
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS CISPR 11national version with changes

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says EN 55014-2. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

IEC 61326 series6
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
EN4
EN 16454
EN 17240
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50364
IEC4
IEC 62209-152
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62369-1
IEC 62443-4-2
Other standards4
ANSI C63.26
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
RSS-170

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

64 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12140-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12140-01-01

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12140-01-02

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12140-01-03

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12140-01-04

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12140-01-05

View scope

Location

Borsigstraße 11, Ratingen, 40880, DE

51.30232, 6.83515

Open in Maps

Accreditation data refreshed from the DAKKS register on .