ACR Technical Services
710 Industrial Park Drive, 23608, Newport News, VA, United States
Visit website- Scope lines
- 37
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 37 scope lines.
A2LA certificate 2171.01 · 37 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540 | - | - |
| 2 | - | SteelShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 2 of 36
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Conductivity – Measuring
Equipment
Liquid
~1 µS/cm
~10 µS/cm
~100 µS/cm
~1000 µS/cm
~1413 µS/cm
~10 000 µS/cm
~100 000 µS/cm
0.43 µS/cm
0.69 µS/cm
4.2 µS/cm
29 µS/cm
31 µS/cm
230 µS/cm
2100 µS/cm
Conductivity
solutions
Gas Detection Equipment
C
3H8
CH
4
CO
O
2
H
2S
0.7 %
2.5 %
0.005 %
0.01 %
20.9 %
0.0016 %
0.0025 %
2.1 %
2.1 %
2.6 %
1.6 %
1.1 %
7.6 %
5.1 %
Calibration gases:
Propane
Methane
Carbon monoxide
Oxygen
Hydrogen sulfide
III. Dimensional
Parameter/Equipment
Range
CMC
2, 6 (±)
Comments
Dial Indicators
3, 7
Up to 1 in
170 µin
Universal calibrator
Dial Indicator Calibrator
Up to 2 in
25 µin
Gage blocks &
electronic height gage
Rulers –
Tape Measures
Up to 24 in
(24 to 48) in
Up to 360 in
0.017 in
0.022 in
0.015 % + 0.019 in
Steel rule | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 3 of 36
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Coating Thickness Gauges
Up to 10 mils
Up to 100 mils
0.074 mils + 0.66 %
0.13 mils + 0.13 %
Coating thickness shims
Coating Thickness Shims
Up to 1000 mils
Up to 25 mm
0.057 mils + 0.0093 %
1.4 µm + 0.0093 %
Micrometer
Feeler Gauges
Up to 0.125 in
94 µin
Micrometer
Loupes, Glass Reticles, Glass
Scales, & Microscopes
(0.001 to 0.22) in
(0.01 to 1) mm
610 µin
7.1 µm
Stage micrometer
Micrometers & Calipers
3, 7
Up to 0.1 in
(> 0.1 to 4) in
(4 to 20) in
60 µin
53 µin
(32 + 3.6L) µin
Gage blocks
Micrometer Rods & Length
End Standards
Up to 10 in
(96 + 2.4L) µin
Gage block & super
micrometer
Anvil & Spindle Flatness on
Micrometers & Calipers
3
2 In Diameter:
Convex
Concave
5.4 µin
5.6 µin
Optical flat &
monochromatic light
Height Gauges
Up to 4 in
(4 to 20) in
(47 + 3.0L) µin
(44 + 2.7L) µin
Gage blocks
Crimpers
(0.011 to 0.06) in
(> 0.06 to 0.25) in
270 µin
(210 + 380D) µin
Pin gages
IV. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 4 (±)
Comments
DC Voltage
3 – Generate
(0 to 220) mV
9.0 μV/V + 0.4 μV
Fluke 5700A/EP w/ opt
3 | ||
| 4 | Ohm’s Law Method | - | See scope document |
| 5 | Ohm’s Law Method | - | See scope document |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 6 of 36
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Resistance3 – Generate
(cont)
Fixed Values:
100 MΩ Steps
1 GΩ Steps
10 kΩ Fixed
1 Ω Fixed
1 Ω to 100 MΩ
Up to 1.1 GΩ
Up to 1 GΩ
Up to 10 GΩ
10 kΩ
1 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
0.33 % + 0.21 MΩ
0.62 %
1.2 μΩ/Ω
1.6 μΩ/Ω
80 μΩ/Ω
84 μΩ/Ω
29 μΩ/Ω
29 μΩ/Ω
15 μΩ/Ω
10 μΩ/Ω
8.9 μΩ/Ω
8.4 μΩ/Ω
6.9 μΩ/Ω
8.9 μΩ/Ω
12 μΩ/Ω
12 μΩ/Ω
19 μΩ/Ω
20 μΩ/Ω
40 μΩ/Ω
40 μΩ/Ω
140 μΩ/Ω
40 μΩ/Ω + 0.0010 Ω
30 μΩ/Ω + 0.0015 Ω
28 μΩ/Ω + 0.0014 Ω
28 μΩ/Ω + 0.0020 Ω
28 μΩ/Ω + 0.000 002 0 kΩ
28 μΩ/Ω + 0.000 020 kΩ
28 μΩ/Ω + 0.000 020 kΩ
28 μΩ/Ω + 0.000 20 kΩ
28 μΩ/Ω + 0.000 20 kΩ
32 μΩ/Ω + 0.0020 kΩ
32 μΩ/Ω + 0.000 002 0 MΩ
60 μΩ/Ω + 0.000 030 MΩ
130 μΩ/Ω + 0.000 050 MΩ
250 μΩ/Ω + 0.0025 MΩ
500 μΩ/Ω + 0.0030 MΩ
0.30 % + 0.10 MΩ
1.5 % + 0.50 MΩ
IET HRRS-B-4-1
M
ESI SR-104U
Leeds & Northrop
4020B
Fluke 5700A/EP
Fluke
5520ASC600 | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 7 of 36
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance
3 – Measure
Up to 10 Ω
Up to 100 Ω
Up to 1000 Ω
Up to 10 kΩ
Up to 100 kΩ
Up to 1 MΩ
Up to 10 MΩ
Up to 100 MΩ
Up to 1 GΩ
19 µΩ/Ω + 50 µΩ
15 µΩ/Ω + 500 µΩ
13 µΩ/Ω + 500 µΩ
12 µΩ/Ω + 5 mΩ
12 µΩ/Ω + 50 mΩ
18 µΩ/Ω + 2 Ω
58 µΩ/Ω + 100 Ω
0.057 % + 1 kΩ
0.57 % + 10 kΩ
Agilent 3458A,
opt 002
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage, Fixed Points –
Measure
2 mV
6 mV
20 mV
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
0.040 %
0.033 %
0.031 %
0.032 %
0.031 %
0.030 %
0.031 %
0.042 %
0.054 %
0.063 %
0.094 %
0.025 %
0.023 %
0.016 %
0.016 %
0.016 %
0.016 %
0.022 %
0.028 %
0.041 %
0.047 %
0.070 %
0.015 %
78 µV/V
72 µV/V
78 µV/V
61 µV/V
63 µV/V
Fluke 792A | to 1000000000 Ω |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 8 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage, Fixed Points –
Measure (cont)
20 mV
60 mV
200 mV
600 mV
2 V
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
91 µV/V
0.016 %
0.022 %
0.032 %
0.053 %
85 µV/V
47 µV/V
42 µV/V
34 µV/V
36 µV/V
36 µV/V
38 µV/V
81 µV/V
0.014 %
0.022 %
0.034 %
59 µV/V
30 µV/V
30 µV/V
16 µV/V
19 µV/V
20 µV/V
31 µV/V
48 µV/V
76 µV/V
0.011 %
0.024 %
33 µV/V
23 µV/V
13 µV/V
12 µV/V
12 µV/V
12 µV/V
13 µV/V
17 µV/V
31 µV/V
36 µV/V
89 µV/V
28 µV/V
18 µV/V
Fluke 792A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 9 of 36
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage, Fixed Points –
Measure (cont)
2 V
6 V
20 V
60 V
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
300 kHz
11 µV/V
11 µV/V
11 µV/V
11 µV/V
11 µV/V
14 µV/V
23 µV/V
27 µV/V
44 µV/V
28 µV/V
18 µV/V
10 µV/V
10 µV/V
10 µV/V
10 µV/V
11 µV/V
11 µV/V
22 µV/V
27 µV/V
43 µV/V
30 µV/V
18 µV/V
16 µV/V
11 µV/V
11 µV/V
11 µV/V
12 µV/V
14 µV/V
23 µV/V
27 µV/V
53 µV/V
28 µV/V
19 µV/V
13 µV/V
12 µV/V
12 µV/V
12 µV/V
13 µV/V
15 µV/V
32 µV/V
Fluke 792A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 10 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage, Fixed Points –
Measure (cont)
200 V
600 V
1000 V
10 Hz
20 Hz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
100 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
42 µV/V
20 µV/V
16 µV/V
15 µV/V
15 µV/V
15 µV/V
17 µV/V
22 µV/V
82 µV/V
43 µV/V
43 µV/V
43 µV/V
83 µV/V
170 µV/V
28 µV/V
22 µV/V
43 µV/V
43 µV/V
82 µV/V
170 µV/V
Fluke 792A
AC Voltage Flatness –
Generate
1 mV
3 mV
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
0.062 %
0.038 %
0.038 %
0.038 %
0.046 %
0.05 %
0.05 %
0.071 %
0.23 %
0.74 %
0.038 %
0.024 %
0.024 %
0.024 %
0.033 %
0.033 %
Fluke 5700A/EP/03 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 11 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage Flatness –
Generate (cont)
3 mV
10 mV
30 mV
100 mV
300 mV
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
0.036 %
0.061 %
0.11 %
0.19 %
0.033 %
0.021 %
0.021 %
0.021 %
0.028 %
0.029 %
0.033 %
0.058 %
0.1 %
0.18 %
0.035 %
0.02 %
0.02 %
0.02 %
0.025 %
0.029 %
0.032 %
0.057 %
0.1 %
0.18 %
0.035 %
0.02 %
0.02 %
0.02 %
0.025 %
0.029 %
0.032 %
0.057 %
0.1 %
0.18 %
0.026 %
0.018 %
0.018 %
0.018 %
0.027 %
Fluke 5700A/EP/03 | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 12 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage Flatness –
Generate (cont)
300 mV
1 V
3 V
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(0.12 to 1.2) MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
0.028 %
0.033 %
0.053 %
0.1 %
0.17 %
0.031 %
0.017 %
0.016 %
0.015 %
0.022 %
0.026 %
0.03 %
0.055 %
0.1 %
0.17 %
0.036 %
0.015 %
0.015 %
0.015 %
0.021 %
0.028 %
0.031 %
0.055 %
0.1 %
0.17 %
Fluke 5700A/EP/03
AC Voltage3 – Generate
(0.22 to 2.2) mV
(2.2 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
0.024 % + 4 µV
90 µV/V + 4 µV
80 µV/V + 4 µV
0.02 % + 4 µV
0.05 % + 4 µV
0.11 % + 10 µV
0.14 % + 10 µV
0.27 % + 20 µV
0.024 % + 4 µV
90 µV/V + 4 µV
80 µV/V + 4 µV
0.02 % + 4 µV
Fluke 5700A/EP | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 13 of 36
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Generate
(cont)
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
0.05 % + 4 µV
0.11 % + 10 µV
0.14 % + 10 µV
0.27 % + 20 µV
0.024 % + 4 µV
90 µV/V + 4 µV
80 µV/V + 4 µV
0.02 % + 4 µV
0.05 % + 4 µV
0.11 % + 10 µV
0.14 % + 10 µV
0.27 % + 20 µV
0.024 % + 40 μV
90 µV/V + 15 μV
50 µV/V + 8 μV
80 µV/V + 10 μV
0.011 % + 30 μV
0.042 % + 80 μV
0.1 % + 200 μV
0.17 % + 300 μV
0.024 % + 0.4 mV
90 µV/V + 0.15 mV
50 µV/V + 0.05 mV
80 µV/V + 0.1 mV
0.01 % + 0.2 mV
0.028 % + 0.6 mV
0.1 % + 2 mV
0.15 % + 3.2 mV
0.024 % + 0.4 mV
90 µV/V + 0.15 mV
50 µV/V + 0.05 mV
80 µV/V + 0.1 mV
0.015 % + 0.2 mV
0.09 % + 0.6 mV
0.44 % + 2 mV
0.8 % + 3.2 mV
0.03 % + 16 mV
0.007 % + 3.5 mV
Fluke 5700A/EP | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 14 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage
3 – Measure
Up to 2.2 mV:
Wideband
(2.2 to 7) mV:
Wideband
(7 to 22) mV:
Wideband
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
0.17 % + 1.3 μV
0.074 % + 1.3 μV
0.042 % + 1.3 μV
0.081 % + 2 μV
0.12 % + 2.5 μV
0.23 % + 4 μV
0.24 % + 8 μV
0.35 % + 8 μV
0.07 % + 1 μV
0.17 % + 1 μV
0.3 % + 1 μV
0.7 % + 2 μV
0.085 % + 1.3 μV
0.037 % + 1.3 μV
0.021 % + 1.3 μV
0.04 % + 2 μV
0.06 % + 2.5 μV
0.12 % + 4 μV
0.13 % + 8 μV
0.23 % + 8 μV
0.07 % + 1 μV
0.1 % + 1 μV
0.17 % + 1 μV
0.37 % + 1 μV
0.029 % + 1.3 μV
0.019 % + 1.3 μV
0.011 % + 1.3 μV
0.021 % + 2 μV
0.031 % + 2.5 μV
0.081 % + 4 μV
0.089 % + 8 μV
0.17 % + 8 μV
0.07 %
0.1 %
0.17 %
0.37 %
Fluke 5790A opt.003
uncertainty of
wideband is for
flatness relative to
1 kHz | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 15 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage
3 – Measure
(cont)
(22 to 70) mV:
Wideband
(70 to 220) mV:
Wideband
(220 to 700) mV:
Wideband
700 mV to 2.2 V:
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
0.024 % + 1.5 μV
0.012 % + 1.5 μV
0.007 % + 1.5 μV
0.013 % + 2 μV
0.026 % + 2.5 μV
0.051 % + 4 μV
0.067 % + 8 μV
0.11 % + 8 μV
0.05 %
0.1 %
0.15 %
0.35 %
0.021 % + 1.5 μV
0.009 % + 1.5 μV
0.004 % + 1.5 μV
0.007 % + 2 μV
0.016 % + 2.5 μV
0.025 % + 4 μV
0.038 % + 8 μV
0.1 % + 8 μV
0.05 %
0.1 %
0.15 %
0.35 %
0.02 % + 1.5 μV
70 μV/V + 1.5 μV
20 μV/V + 1.5 μV
50 μV/V + 2 μV
70 μV/V + 2.5 μV
0.016 % + 4 μV
0.026 % + 8 μV
0.09 % + 8 μV
0.05 %
0.1 %
0.15 %
0.35 %
0.021 %
80 µV/V
Fluke 5790A opt.003
uncertainty of
wideband is for
flatness relative to
1 kHz | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 16 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage
3 – Measure
(cont)
700 mV to 2.2 V:
Wideband
(2.2 to 7) V:
Wideband
(7 to 22) V
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
30 µV/V
50 µV/V
80 µV/V
0.018 %
0.03 %
0.1 %
0.05 %
0.1 %
0.15 %
0.35 %
0.02 %
70 µV/V
20 µV/V
50 µV/V
70 µV/V
0.016 %
0.026 %
0.09 %
0.05 %
0.1 %
0.15 %
0.35 %
0.02 %
70 µV/V
20 µV/V
50 µV/V
80 µV/V
0.019 %
0.04 %
0.12 %
0.02 %
70 µV/V
30 µV/V
50 µV/V
90 µV/V
0.02 %
0.041 %
0.12 %
Fluke 5790A opt.003
uncertainty of
wideband is for
flatness relative to
1 kHz | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 17 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage
3 – Measure
(cont)
(70 to 220) V
(220 to 700) V
(700 to 1000) V
Up to 10 mV
(10 to 100) mV
(0.1 to 10) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.02 %
70 µV/V
30 µV/V
70 µV/V
0.01 %
0.021 %
0.05 %
0.02 %
0.01 %
40 µV/V
0.013 %
0.05 %
0.02 %
0.01 %
0.004 %
0.013 %
0.05 %
0.03 % + 3 µV
0.02 % + 1.1 µV
0.03 % + 1.1 µV
0.1 % + 1.1 µV
0.5 % + 1.1 µV
4 % + 2 µV
1.2 % + 5 µV
70 µV/V + 4 µV
70 µV/V + 2 µV
0.014 % + 2 µV
0.03 % + 2 µV
0.08 % + 2 µV
0.3 % + 10 µV
1 % + 10 µV
70 µV/V + 0.4 mV
70 µV/V + 0.2 mV
0.014 % + 0.2 mV
0.03 % + 0.2 mV
0.08 % + 0.2 mV
0.3 % + 1 mV
1 % + 1 mV
Fluke 5790A opt.003
uncertainty of
wideband is for
flatness relative to
1 kHz
Agilent 3458A, opt
002 NOTE:
synchronous sub-
sampled mode | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 18 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage3 – Measure
(cont)
(10 to 100) V
(100 to 1000) V
Up to 40 kV
pk
Up to 28 kVrms
(1 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
60 Hz
60 Hz
0.02 % + 4 mV
0.02 % + 2 mV
0.035 % + 2 mV
0.12 % + 2 mV
0.4 % + 10 mV
1.5 % + 10 mV
0.04 % + 40 mV
0.04 % + 20 mV
0.06 % + 20 mV
0.12 % + 20 mV
0.3 % + 20 mV
5 %
5 %
Agilent 3458A, opt
002 NOTE:
synchronous sub-
sampled mode
Fluke 80K-40
AC Power3 – Generate
Up to 300 W
(330 to 2200) W
(2200 to 20 500) W
(45 to 65) Hz
0.12 %
0.11 %
0.12 %
Fluke 5520A plus
resistance standard
AC Current
3 – Generate
(0 to 220) μA
(0.22 to 2.2) mA
(2.2 to 22) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20 Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.025 % + 16 nA
0.016 % + 10 nA
0.012 % + 8 nA
0.028 % + 12 nA
0.11 % + 65 nA
0.025 % + 40 nA
0.016 % + 35 nA
0.012 % + 35 nA
0.02 % + 110 nA
0.11 % + 650 nA
0.025 % + 400 nA
0.016 % + 350 nA
0.012 % + 350 nA
0.02 % + 550 nA
0.11 % + 5 μA
Fluke 5700A/EP | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 19 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current
3 – Generate
(cont)
(22 to 220) mA
(0.22 to 2.2) A
(29 to 330) μA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(1.1 to 3) A
(2.2 to 22) A
Clamp-On Meters –
Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
Non-Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
10 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 30) kHz
(10 to 30) kHz
(10 to 30) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz*
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.025 % + 4 μA
0.016 % + 3.5 μA
0.012 % + 2.5 μA
0.02 % + 3.5 μA
0.11 % + 10 μA
0.026 % + 35 μA
0.045 % + 80 μA
0.7 % + 160 μA
1.6 % + 0.4 μA
1 % + 0.6 μA
0.4 % + 4 μA
0.4 % + 200 μA
2.5 % + 5 mA
0.055 % + 1 mA
0.051 % + 1 mA
0.05 % + 1 mA
0.05 % + 1 mA
0.16A
0.18A
0.26 % + 0.11 A
0.74 % + 0.088 A
0.3 % + 0.12 A
0.8 % + 0.1 A
0.18 A
0.23 A
0.55 % + 0.27 A
1 % + 0.27 A
0.57 % + 0.95 A
0.98 % + 0.93 A
Fluke 5700A/EP
Fluke 5520A SC600
Fluke 5700A/EP
Fluke 5520A SC600
*multiply by f in kHz
Fluke 5222A
Fluke 5500A coil | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 20 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current
3 – Measure
Up to 100 µA
(0.1 to 1) mA
(1 to 100) mA
(0.1 to 1) A
Up to 550 μA
550 μA to 5.5 mA
(5.5 to 22) mA
(22 to 550) mA
550 mA to 2.2 A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
0.4 % + 30 nA
0.15 % + 30 nA
0.06 % + 30 nA
0.4 % + 0.2 µA
0.15 % + 0.2 µA
0.06 % + 0.2 µA
0.03 % + 0.2 µA
0.4 % + 20 µA
0.15 % + 20 µA
0.06 % + 20 µA
0.03 % + 20 µA
0.06 % + 20 µA
0.4 % + 40 µA
0.6 % + 150 µA
0.4 % + 0.2 mA
0.16 % + 0.2 mA
0.08 % + 0.2 mA
0.1 % + 0.2 mA
0.3 % + 0.2 mA
1 % + 0.4 mA
0.02 %
0.008 %
0.005 %
0.02 %
0.008 %
0.005 %
0.02 %
0.008 %
0.005 %
0.02 %
0.008 %
0.005 %
0.02 %
0.009 %
0.008 %
Agilent 3458A opt.
002
Fluke 5790A w/ A40 | to 100 µA |
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 21 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current
3 – Measure
(cont)
(2.2 to 11) A
(11 to 20) A
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(5 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
0.022 %
0.013 %
0.021 %
0.038 %
0.034 %
0.034 %
Fluke 5790A w/ A40
Inductance3 – Measure
0.01 μH to 4.1 H
(4.1 to 99 999) H
(12 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 100) kHz
(12 to 100) Hz
100 Hz to 1 kHz
(1 to 20) kHz
0.049 %
0.029 %
0.059 %
0.23 %
0.049 %
0.029 %
0.21 %
GenRad 1693
Digibridge
NOTE: slow measure
rate, averaging,
open/short
Inductance3 – Generate
100 mH fixed
100 Hz
1 kHz
0.023 %
0.023 %
General ratio 1482-L
Capacitance3 – Measure
0.000 01 pF to 6.4 nF
6.4 nF to 99 999 μF
(12 to 100) Hz
100 Hz to 1 kHz
(1 to 20) kHz
(12 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 100) kHz
0.05 %
0.029 %
0.21 %
0.049 %
0.029 %
0.059 %
0.23 %
GenRad 1693
Digibridge
NOTE: slow measure
rate, averaging,
open/short
Capacitance3 – Generate
(0.19 to 3.3) nF
(3.3 to 11) nF
(11 to 110) nF
(110 to 330) nF
10 Hz to 10 kHz
0.58 % + 0.01 nF
0.29 % + 0.01 nF
0.29 % + 0.1 nF
0.29 % + 0.3 nF
Fluke 5520A SC600 | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 22 of 36
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance
3 – Generate
(cont)
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
1000 pF
10 Hz to 10 kHz
1 kHz
0.29 % + 1 nF
0.29 % + 3 nF
0.29 % + 10 nF
0.46 % + 30 nF
0.52 % + 100 nF
0.52 % + 300 nF
0.52 % + 1 µF
0.52 % + 3 µF
0.52 % + 10 µF
0.87 % + 30 µF
1.3 % + 100 µF
0.64 pF of value
Fluke 5520A SC600
GenRad 1404-A
Phase
3 – Generate
Up to 360°
1 Hz to 1 kHz
(1 to 6.3) kHz
(6.3 to 50) kHz
(50 to 100) kHz
0.0053°
0.01°
0.017°
0.046°
Clarke-Hess 5000
Phase
3 – Measure
(10 to 32) mVrms
32 mV to 100 V
rms
(100 to 320) Vrms
Up to 360°:
1:1 Resistive
1:1 Capacitive
1 Hz to 10 kHz
(10 to 50) kHz
50 kHz to 10 MHz
(1 to 10) Hz
10 Hz to 50 kHz
50 kHz to 10 MHz
(1 to 10) Hz
10 Hz to 5 kHz
1 Hz to 1 kHz
(1 to 50) kHz
(1 to 50) kHz
(50 to 200) kHz
0.23°
0.4°
0.7°
0.1°
0.05°
0.4°
0.23°
0.11°
0.002°
0.003°
0.003°
0.009°
Krohn-Hite 6620
phase meter
Clarke-Hess 5002
Agilent 3458A opt.
002 | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 23 of 36
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Phase
3 – Measure (cont)
Up to 360°:
10:1 Capacitive
100:1 Capacitive
(1 to 50) kHz
(50 to 200) kHz
(1 to 50) kHz
(50 to 200) kHz
0.003°
0.009°
0.003°
0.009°
Clarke-Hess 5002
Agilent 3458A opt.
002
Distortion3 – Measure
(0.3 to 100) %:
< 30 V
(30 to 300) V
0.1 %:
< 30 V
(0.001 to 100) %:
50 mV to 300 V
10 Hz to 1 MHz
(1 to 3) MHz
10 Hz to 300 kHz
(300 to 500) kHz
(0.5 to 3) MHz
(10 to 20) Hz
(20 to 30) Hz
30 Hz to 300 kHz
(300 to 500) kHz
(0.5 to 1.2) MHz
20 Hz to 20 kHz
(20 to 100) kHz
3 % of full scale
7.1 % of full scale
3 % of full scale
7.1 % of full scale
13 % of full scale
13 % of full scale
7.1 % of full scale
3 % of full scale
7.1 % of full scale
13 % of full scale
1.2 dB
2.3 dB
HP 334A
Agilent 8903B
Oscilloscopes
3 –
Square Wave Signal:
10 Hz to 10 kHz
50 Ω Impedance
1 MΩ Impedance
Level Sine Wave
Square Wave Signal
1 mV to 6.6 V
pk – pk
1 mV to 130 Vpk - pk
5 mV to 5.5 V
50 kHz to 100 MHz
0.25 % + 40 µV
0.1 % + 40 µV
2 % + 300 µV
3.5 % + 300 µV
Fluke 5520A SC600 | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 24 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
Oscilloscopes
3 – (cont)
Square Wave Signal
Amplitude
(Reference, 50 kHz)
Flatness
(Reference, 50 kHz)
Time Markers
(5-2-1 Sequence) into a 50
W Load
Rise Time:
2.5 mV to 2.5 V
(100 to 300) MHz
(300 to 600) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
5 s to 50 ms
20 ms to 100 ns
(5 to 2) ns
10 ns
(50 to 20) ns
(24 to 300) ps
4 % + 300 µV
6 % + 300 µV
1.5 % + 100 µV
2 % + 100 µV
4 % + 100 µV
25 µs/s
2.5 µs/s
2.5 µs/s
2.5 µs/s
2.5 µs/s
27 %
Fluke 5520A SC600
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples
3 –
Type B
Type C
Type E
(600 to 800) °C
(> 800 to 1000) °C
(> 1000 to 1550) °C
(> 1550 to 1820) °C
(0 to 150) °C
(> 150 to 650) °C
(> 650 to 1000) °C
(> 1000 to 1800) °C
(> 1800 to 2316) °C
(-250 to -100) °C
(> -100 to -25) °C
(> -25 to 350) °C
(> 350 to 650) °C
(> 650 to 1000) °C
0.44 °C
0.36 °C
0.32 °C
0.35 °C
0.32 °C
0.29 °C
0.32 °C
0.45 °C
0.70 °C
0.43 °C
0.22 °C
0.22 °C
0.21 °C
0.23 °C
Fluke 5522A | ||
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 25 of 36
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples
3 – (cont)
Type J
Type K
Type N
Type R
Type S
Type T
(-210 to -100) °C
(> -100 to -25) °C
(> -25 to 150) °C
(> 150 to 760) °C
(> 760 to 1200) °C
(-210 to < 0) °C
(0 to 1200) °C
(-210 to -100) °C
(> -100 to -25) °C
(> -25 to 120) °C
(> 120 to 1000) °C
(> 1000 to 1372) °C
(-210 to < 0) °C
(0 to 1200) °C
(-200 to -100) °C
(> -100 to -25) °C
(> -25 to 120) °C
(> 120 to 410) °C
(> 410 to 1300) °C
(0 to 250) °C
(> 250 to 400) °C
(> 400 to 1000) °C
(> 1000 to 1767) °C
(0 to 250) °C
(> 250 to 1000) °C
(> 1000 to 1400) °C
(> 1400 to 1767) °C
(-250 to -150) °C
(> -150 to 0) °C
(> 0 to 120) °C
(> 120 to 400) °C
0.25 °C
0.18 °C
0.17 °C
0.21 °C
0.24 °C
0.28 °C
0.18 °C
0.31 °C
0.22 °C
0.21 °C
0.25 °C
0.36 °C
0.28 °C
0.18 °C
0.37 °C
0.26 °C
0.24 °C
0.22 °C
0.27 °C
0.48 °C
0.34 °C
0.31 °C
0.36 °C
0.41 °C
0.34 °C
0.34 °C
0.40 °C
0.51 °C
0.24 °C
0.19 °C
0.19 °C
Fluke 5522A
Fluke 5700A/EP &
digital multimeter &
ice point reference
Fluke 5522A
Fluke 5700A/EP &
digital multimeter &
ice point reference
Fluke 5522A | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 26 of 36
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicating Systems
3 –
Pt 385, 100 Ω
PtNi 385, 120 Ω
Cu 427, 10 Ω
(-200 to 0) °C
(> 0 to 100) °C
(> 100 to 260) °C
(> 260 to 300) °C
(> 300 to 600) °C
(> 600 to 630) °C
(-80 to 100) °C
(> 100 to 260) °C
(-100 to 260) °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.24 °C
0.08 °C
0.15 °C
0.34 °C
Fluke 5520A SC600
V. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC
2, 4, 6 (±)
Comments
RF Power – Generate
Sine Wave (50 Ω):
1 mV to 3 Vp-p
(-56.02 to 13.52) dB
(3 to 10) V
p-p
(13.52 to 23.98) dB
(25 to 10) dB
(10 to -10) dB
(-10 to -60) dB
(-60 to -110) dB
(25 to 10) dB
(10 to -10) dB
(-10 to -60) dB
(-60 to -110) dB
1 mW
Up to 50 W
0.001 Hz to 100 kHz
100 kHz to 20 MHz
0.001 Hz to 100 kHz
100 kHz to 20 MHz
10 MHz to 2 GHz
(2 to 18) GHz
50 MHz
(1 to 400) MHz
0.15 dB
0.23 dB
0.19 dB
0.25 dB
1.0 dB
0.75 dB
1.0 dB
1.5 dB
1.1 dB
0.75 dB
1.3 dB
2.0 dB
0.010 mW
2.5 %
HP 3325A opt 001,
002
HP 3325A opt 001,
002
HP 83630A opt 001,
008, H53
HP 436A
HP 83630A &
amplifier | ||
| 27 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 27 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
RF Power – Measure
1 µW to 100 mW
(-30 to +20) dB
1 µW to 100 mW
(-30 to +20) dB
1 µW to 100 mW
(-30 to +20) dB
1 mW
Up to 50 W
(100 to 300) kHz
300 kHz to 10 MHz
10 MHz to 2 GHz
(2 to 4.2) GHz
10 MHz to 1 GHz
(1 to 3) GHz
(3 to 13) GHz
(13 to 18) GHz
(1 to 4) GHz
(4 to 12) GHz
(12 to 18) GHz
(18 to 26.5) GHz
50 MHz
(1 to 400) MHz
0.20 dB
0.11 dB
0.11 dB
0.12 dB
0.13 dB
0.11 dB
0.11 dB
0.11 dB
0.11 dB
0.11 dB
0.12 dB
0.14 dB
0.010 mW
2.5 %
HP 436A with 8482A
HP 436A with 8481A
HP 436A with 8485A
HP 432A, 478AH73,
& 34401A
HP 436A with 8482A,
directional coupler, &
attenuators
Tuned RF Power – Measure
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
100 kHz to 26.5 GHz
0.17 dB
0.18 dB
0.20 dB
0.23 dB
0.24 dB
0.26 dB
0.34 dB
0.35 dB
0.37 dB
0.38 dB
0.41 dB
0.53 dB
HP 8902A,
HP 11722A,
HP 11792A
Attenuation – Generate
SMA, 1 dB step
(1 to 11) dB
SMA, 10 dB step
(10 to 110) dB
DC to 12.4 GHz
(12.4 to 26.5) GHz
DC to 12.4 GHz
(12.4 to 26.5) GHz
2.1 % + 0.24 dB
2.1 % + 0.29 dB
2.3 % + 0.23 dB
2.7 % + 0.15 dB
Agilent 8494H
Agilent 8496H | ||
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 28 of 36
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
Frequency Modulation –
Generate
Rate: 100 kHz to 8 MHz
Dev: < 500 kHz peak
(1 to 26.5) GHz
8.8 %
Agilent 83630A
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Dev: ≤ 40 kHz
Rate: 50 Hz to 100 kHz
Dev: ≤ 400 kHz
Rate: 20 Hz to 200 kHz
Dev: ≤ 400 kHz
(0.25 to 10) MHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
0.73 % + 1 digit
3.0 % + 1 digit
4.3 % + 1 digit
HP 8902A with
11793A
Amplitude Modulation –
Measure
Rate: 150 kHz to 10 MHz
Depths: (5 to 99) %
Rate: 150 kHz to 10 MHz
Depths: Up to 99 %
Rate: (10 to 1300) MHz
Depths: (5 to 99) %
Rate: (10 to 1300) MHz
Depths: Up to 99 %
Rate: (1.3 to 18) GHz
Depths: (5 to 99) %
Rate: (1.3 to 18) GHz
Depths: Up to 99 %
50 Hz to 10 kHz
20 Hz to 10 kHz
50 Hz to 50 kHz
20 Hz to 100 kHz
50 Hz to 50 kHz
20 Hz to 100 kHz
1.9 % + 1 digit
3.0 % + 1 digit
1.3 % + 1 digit
3.3 % + 1 digit
1.3 % + 1 digit
3.3 % + 1 digit
HP 8902A with
11793A
Amplitude Modulation –
Generate
Rate: DC to 100 kHz
Depths: (5 to 99) %
10 MHz to 26.5 GHz
6.3 %
Agilent 83630A | ||
| 29 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 29 of 36
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Phase Modulation –
Measure
150 kHz to < 10 MHz
Carrier
10 MHz to 18.0 GHz
Carrier
200 Hz to 10 kHz
200 Hz to 20 kHz
5.1 % + 1 digit
6.7 % + 1 digit
HP 8902A with
11793A
VI. Mechanical
Parameter/Equipment
Range
CMC
2, 6, 8 (±)
Comments
Accelerometers
Frequency Response
(0.02 to 5000) pC/g
(1 to 10 000) mV/g
Sensitivity @ 100 Hz
(10 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
100 pC/g
2.7 %
2.4 %
3.3 %
2.4 %
PCB 301A11 with
signal conditioner,
frequency
generator, DMM,
& shaker
Pressure & Vacuum
Measure & Measuring
Equipment
3, 7 –
Pneumatic
(30 to 100) microns
(> 100 to 1000) microns
(1 to 10) Torr
(0.1 to 1.0) inꞏH
2O
(> 1.0 to 24) inꞏH2O
(0.2 to 25) psia
(0.2 to 25) psig
(2 to 1000) psig
(1000 to 10 000) psig
(> 10 000 to 12 148) psig
(20 to 100) psi
(> 100 to 1000) psi
(> 1000 to 10 000) psi
4.3 % + 1.0 microns
6.4 % – 1.1 microns
0.63 %
0.0013 inꞏH
2O
0.012 % 0.0012 inꞏH2O
15 parts in 10
6 psia
15 parts in 106 psig
16 parts in 106 psig
34 parts in 10
6
0.0037 % – 0.03 psi
0.021 % - 0.000 90 psi
0.018 % + 0.021 psi
0.0050 % + 0.80 psi
Leybold CTR 90
Dwyer 1425-24
Ruska 2465-725
Ruska 2465-729
Ruska 2400-735-
00, Ruska 2402
Fluke 2700G | ||
| 30 | - | AirShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 30 of 36
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Pressure & Vacuum
Measure & Measuring
Equipment
3, 7 – (cont)
Pneumatic
Hydraulic
(10 to 100) psi
(> 30 to 300) psi
(-14.5 to 0) psi
(> 0.5 to 5) psi
(> 1.5 to 15) psia
(> 30 to 300) psi
(> 100 to 1000) psi
(> 300 to 3000) psi
(> 500 to 5000) psi
(> 1000 to 10 000) psi
(1000 to 10 000) psi
(> 10 000 to 12 140) psi
(> 100 to 1000) psi
(> 1000 to 10 000) psi
(> 100 to 1000) psi
(> 300 to 3000) psi
(> 500 to 5000) psi
(> 1000 to 10 000) psi
0.031 % + 0.021 psi
0.024 % + 0.028 psi
0.042 psi
0.0012 psi
0.0024 psi
0.067 psi
0.28 psi
0.67 psi
1.2 psi
2.3 psi
31 parts in 10
6
0.0037 % + 0.06 psi
0.018 % + 0.021 psi
0.0050 % + 0.80 psi
0.28 psi
0.67 psi
1.2 psi
2.3 psi
Crystal XP2i
Druck DPI-610 &
transducers
Ruska 2400-735-00
Fluke 2700G
Druck DPI-610 &
transducers
Air/Nitrogen Flow
3, 7 –
Measure
(0.01 to 1000) SLPM
(0.0004 to 35) SCFM
(3 to 10) sccm
(10 to 30) sccm
(30 to 100) sccm
(100 to 300) sccm
(0.3 to 1.0) slpm
(1.0 to 3.0) slpm
(3.0 to 10) slpm
(10 to 30) slpm
(30 to 100) slpm
(100 to 300) slpm
(300 to 1000) slpm
(1000 to 3000) slpm
0.68 % + 0.0090 sccm
0.67 % – 0.0031 sccm
0.65 % + 0.033 sccm
0.66 % + 0.012 sccm
0.59 % + 0.000 37 slpm
0.63 % + 0.000 47 slpm
0.56 % + 0.0054 slpm
0.63 % + 0.000 91 slpm
0.65 % + 0.017 slpm
0.72 % + 0.030 slpm
0.76 % + 0.062 slpm
0.99 % – 1.7 slpm
CME FCS-8A &
laminar flow
elements | See scope document |
| 31 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 31 of 36
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Torque
3, 7 – Measure
(5 to 50) ozfꞏin
(20 to 200) ozfꞏin
(5 to 50) lbfꞏin
(10 to 100) lbfꞏin
(40 to 400) lbfꞏin
(12.5 to 125) lbfꞏft
(60 to 600) lbfꞏft
(60 to 600) lbfꞏft
(100 to 1000) lbfꞏft
0.60 % + 0.002 ozfꞏin
0.59 % + 0.012 ozfꞏin
0.59 % + 0.0035 lbfꞏin
0.59 % + 0.004 lbfꞏin
0.62 % + 0.012 lbfꞏin
0.35 % + 0.011 lbfꞏft
0.36 % + 0.014 lbfꞏft
0.60 % + 0.010 lbfꞏft
0.33 % + 0.030 lbfꞏft
CDI 2000-4-02
CDI 2000-5-02
CDI 501-I-DTT
CDI 1001-I-DTT
CDI 4002-I-DTT
CDI 2000-10-02
CDI 2000-12-02
CDI 6004-F-DTT
CDI 2000-13-02
Torque – Measuring
Equipment
3, 7
(8 to 336) ozfꞏin
(5 to 200) lbfꞏin
(15 to 260) lbfꞏft
(50 to 1050) lbfꞏft
0.025 % + 0.0022 ozfꞏin
0.032 % + 0.0012 lbfꞏin
0.030 % + 0.0014 lbfꞏft
0.038 % + 0.015 lbfꞏft
Torque
wheel/arms,
Class F weights
& pan
Scales & Balances3, 7 –
Fixed Values:
Up to 10 kg*
Up to 1000 lb*
(1 to 500) mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
0.5 lb
1 lb
2 lb
5 lb
10 lb
20 lb
25 lb
50 lb
0.75 lb
5 lb
8 lb
13 lb
0.019 mg
0.042 mg
0.043 mg
0.043 mg
0.061 mg
0.090 mg
0.15 mg
0.35 mg
0.63 mg
1.5 mg
3.1 mg
0.000 13 lb
0.000 15 lb
0.000 26 lb
0.000 60 lb
0.0011 lb
0.0024 lb
0.0031 lb
0.0060 lb
0.015 lb
0.017 lb
0.017 lb
0.019 lb
Class 1, 2 or 3
weights.
*Fixed values.
Uncertainties are
per weight.
Class F weights
*Fixed values.
Uncertainties are
per weight.
Weight pans | ||
| 32 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) 02/10/2025 Page 32 of 36
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Force – Measuring
Equipment (Tension only)
(1 to 10) lb
(> 10 to 100) lb
(> 100 to 1000 lb
0.0056 % + 0.0037 lbf
0.0063 % + 0.0037 lbf
0.011 % – 0.0010 lbf
Class F weights
Mass
7 – Measure
(0.1 to 62) g
(> 62 to 205) g
(0 to 600) g
(0 to 6000) g
(0.2 to 1) kg
(> 1 to 10) kg
(> 10 to 50) kg
0.000 67 % + 0.000 081 g
0.000 45 % + 0.000 30 g
0.000 14 % + 0.0037 g
0.000 16 % + 0.025 g
0.34 %
0.035 %
0.007 %
Mettler AT261
Mettler XS603S
Mettler XS6002S
TIF 9010A
Piston Operated Volumetric
Apparatus (POVA) –
(10 to 100) μL
(100 to 1000) μL
(> 1 to 10) mL
(> 10 to 100) mL
(> 100 to 200) mL
0.16 % + 0.078 μL
0.21 % + 0.030 μL
0.22 % + 0.000 10 mL
0.21 % + 0.0010 mL
0.21 %
Mettler AT261 &
DI H2O
Notes: pipettes &
syringes
Piston Operated Volumetric
Apparatus (POVA)
3 –
(1 to 10) L
0.30 % + 0.0020 L
TIF 9010A & DI
H2O
Notes: pipettes &
syringes
Velocity
3, 7 – Measure
(1575 to 6000) fpm
1.5 % + 2.4 fpm
Alnor RVA501
Rotational Speed,
RPM
3, 7 – Measuring
Equipment
Optical
Mechanical
(10 to 100 000) rpm
Up to 5000 rpm
0.001 % + 0.13 rpm
0.025 %
HP 3325A
Quantum dynamics
N-11-ECS/3A | ||
| 33 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) Revised 02/10/2025 Page 33 of 36
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Rotational Speed,
RPM
3, 7– Measure
Optical
Mechanical
(10 to 600) rpm
(> 600 to 100 000) rpm
Up to 5000 rpm
0.041 % + 0.42 RPM
0.010 % + 0.60 RPM
0.15 % + 2.0 RPM
Tachometer
VII. Thermodynamics
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Relative Humidity
3 –
Measuring Equipment
11.31 % RH
33.07 % RH
75.47 % RH
97.6 % RH
(10 to 40) % RH
(> 40 to 97) % RH
0.61 % RH
0.62 % RH
0.97 % RH
1.5 % RH
0.97 % RH
1.3 % RH
LiCl
MgCl
2
NaCl
K
2SO4
Vaisala MI70 with
HMP-77B
Relative Humidity
3 –
Measure
(10 to 40) % RH
(> 40 to 97) % RH
0.83 % RH
1.1 % RH
Vaisala MI70 with
HMP-77B
Temperature
3 – Measure
Chambers
Infrared
(-80 to 150) °C
(0 to 1000) °C
(-196 to 0) °C
0 °C
(> 0 to 232) °C
(> 232 to 420) °C
(> 420 to 660) °C
0 °C
(> 0 to 260) °C
(0 to 100) °C
(> 100 to 500) °C
0.26 °C
0.089 °C
0.031 °C
0.01 °C
0.037 °C
0.048 °C
0.34 °C
0.025 °C
0.15 °C
1.1 % + 0.88 °C
1.7 % + 0.3 °C
Fluke 1524 with
PRT,
Fluke 1524 with
RTD,
Fluke 5624 PRT,
Fluke 5626 PRT
Fluke 5627 PRT
Fluke 561 | ||
| 34 | ison to PRT Fluke 9141 Notes: add 1 | - | See scope document |
| 35 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) Revised 02/10/2025 Page 35 of 36
IX. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Frequency – Measuring
Equipment
10 MHz reference
(1 to 10) Hz
(10 to 100) Hz
(0.1 to 1) kHz
(1 to 10) kHz
(10 to 100) kHz
(0.1 to 1) MHz
(1 to 10) MHz
(10 to 21) MHz
2.5 × 10
-10 Hz/Hz
1.3 × 10-2 Hz/Hz
1.3 × 10-3 Hz/Hz
1.3 × 10-4 Hz/Hz
1.3 × 10-5 Hz/Hz
1.7 × 10-6 Hz/Hz
4.9 × 10-7 Hz/Hz
2.9 × 10-7 Hz/Hz
1.7 × 10-7 Hz/Hz
Agilent Z3816A
Agilent 3325B/GPS
Frequency – Measure
1 Hz to 225 MHz
225 MHz to 3 GHz
(10 to 100) MHz
(0.1 to 1) GHz
(1 to 10) GHz
(10 to 20) GHz
2.9 × 10
-10 Hz/Hz +
0.14 x 10-6 Hz
2.9 × 10
-9 Hz/Hz
2.4 × 10-8 Hz/Hz
2.4 × 10-9 Hz/Hz
3.5 × 10-10 Hz/Hz
2.8 × 10-10 Hz/Hz
Agilent 53132A/GPS
Agilent 53132A/GPS
HP 5350B/GPS
Timers/Stopwatches
(1 to 86 400) sec
(1 to 3600) sec
0.039 sec
0.50 sec
Agilent 53132A/GPS
Stopwatch
__________________________________________________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 36 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2171.01) Revised 02/10/2025 Page 36 of 36
4 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
and D is the diameter of the device in inches.
6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
7 The contributions from the “best existing device” are not included in the CMC claim.
8 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 37 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- All American Scales & CalibrationParis, OH · ~568 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
- Cleveland Specialty Inspection ServicesMentor, OH · ~649 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
- Trescal, Inc - Milwaukee, WIMilwaukee, WI · ~1,165 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
- MSI-Viking GageCanton, MI · ~1,330 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
- BHD Test & MeasurementThornton, CO · ~2,483 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.