Registers refreshed 2026-11-20.See refresh dates
China

Guangdong Global Testing Technology Co.,

Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong Pr., China, Dongguan, 523808, People's Republic of China, Dongguan, China

Visit website
A2LA 6947.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
49
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 49 standard numbers and the 17 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI30
ETSI EN 300 086
ETSI EN 300 113
ETSI EN 300 219
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-2
ETSI EN 300 296
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-1
ETSI EN 300 422-2
ETSI EN 300 422-3
Show all 30
ETSI EN 300 440
ETSI EN 301 166
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3
ETSI EN 303 340
ETSI EN 303 345-1
ETSI EN 303 372-2
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 687
ETSI TS 134 121-1
ETSI TS 136 521-1
ETSI TS 151 010-1
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011, IEC 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national

National versions in the same scope

AS CISPR 14.1national version with changes

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national

National versions in the same scope

AS CISPR 15national version with changes

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national

National versions in the same scope

AS/NZS CISPR 32identical to it

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

EN3
EN 50385
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
IEC 61000 series3
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national

National versions in the same scope

AS/NZS 61000.4.2probably the same standard; matched by number only

Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

6947.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 6947.01

LineMethodMatrixRange
147 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; EN 55011; EN IEC 55011; CISPR 11; AS/NZS CISPR 11; J55011; BS EN 55011; BS EN IEC 55011; EN 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J55014-1; BS EN 55014-1; BS EN IEC 55014-1; EN 55015; BS EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; J55015; BS EN IEC 55015; EN 55032; SANS 2332; CISPR 32; AS/NZS CISPR 32; J55032; BS EN 55032; VCCI-32-1; VCCI-CISPR 32 (up to 6 GHz); IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; AS/NZS 61000.3.2; JIS C 61000-3-2; BS EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; EN IEC 61000-3-3; AS/NZS 61000.3.3; BS EN 61000-3-3; BS EN IEC 61000-3-3; SANS 61000-3-3; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; AS/NZS 61000.4.2electrical devicesto 40 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6947.01) Revised 11/24/2025 Page 2 of 5 Test Technology: Test Method(s): Radiated Immunity (up to 6GHz, 30V/m) IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; AS/NZS 61000.4.3 Electrical Fast/Transient Burst (EFT) IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; AS/NZS 61000.4.4 Surge IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; AS/NZS 61000.4.5 Conducted Immunity IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6; BS EN 61000-4-6; BS EN IEC 61000-4-6; AS/NZS 61000.4.6 Power frequency magnetic field immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; AS/NZS 61000.4.8 Voltage Dips and Short Interruptions and Voltage Variations IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11; AS/NZS 61000.4.11; IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34; BS EN IEC 61000-4-34; AS/NZS 61000.4.34 Generic Standards, Product Family Standards and Industry Specific Standards ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-34; ETSI EN 301 489-52; ETSI EN 301 489-53; EN 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-1; BS EN IEC 61000-6-1; AS/NZS 61000.6.1; EN 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-2; BS EN IEC 61000-6-2; AS/NZS 61000.6.2; EN 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-3; BS EN IEC 61000-6-3; AS/NZS 61000.6.3; EN 61000-6-4; EN IEC 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; EN 55014-2; EN IEC 55014-2; CISPR 14-2; AS/NZS CISPR 14.2; BS EN 55014-2; BS EN IEC 55014-2; EN 55035; CISPR 35; BS EN 55035; SANS 2335; IEC 61326-1; EN 61326-1; EN IEC 61326-1; BS EN 61326-1; BS EN IEC 61326-1; IEC 61326-2-6; EN 61326-2-6; BS EN 61326-2-6; IEC 61547; EN IEC 61547; BS EN 61547; BS EN IEC 61547; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; IEC 60669-2-1; EN 60669-2-1; EN IEC 60669-2-1; AS/NZ 60669.2.1; BS EN 60669-2-1; BS EN IEC 60669-2-1; EN 50130-4; BS EN 50130-4; EN 50121-3-2; BS EN 50121-3-2; EN 50121-4; BS EN 50121-4; EN 50121-5; BS EN 50121-5; IEC 62040-2; EN IEC 62040-2; BS EN IEC 62040-2; IEC 61851-21-2; EN IEC 61851-21-2; BS EN IEC 61851-21-2; IEC 62920; EN 62920; BS EN 62920; EN 300 386
3ANSI C63.10-2020+Cor.1-2023; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024; 47 CFR FCC Part 15 Subpart C, F; 47 CFR FCC Part 15 Subpart E; KDB 905462 D02 UNII DFS Compliance Procedures New Rules; CFR 47 FCC Parts 20, 22, 24, 25, 27, 90, 95, 97, 101; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; RSS-GEN; RSS-119; RSS-130; RSS-132; RSS-133; RSS-139; RSS-195; RSS-199; RSS-210; RSS-211; RSS-216; RSS-220; RSS-247; RSS-248; ETSI EN 300 328; MIC Notice No.88 Appendix No.43 & 44; ETSI EN 301 893; MIC Notice No.88 Appendix No.45 & 47; ETSI EN 303 687; ETSI EN 300 086; ETSI EN 300 113; ETSI EN 300 219; ETSI EN 300 296; ETSI EN 301 166; ETSI EN 302 065-1; ETSI EN 302 065-2; ETSI EN 302 065-3; ETSI EN 303 340; ETSI EN 303 345-1; ETSI EN 303 372-2; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-2; EN 300 422-1; EN 300 422-2; EN 300 422-3; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 303 413; ETSI EN 303 417; Japan MIC Radio Law Article 38-2-2, Paragraph 1, Item 8; Radio Law Article 38-2-2, Paragraph 1, Item 47-1/2/3; ETSI EN 301 511; ETSI TS 151 010-1; 3GPP TS 51.010-1; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI 301 908-13; ETSI TS 134 121-1; 3GPP TS 34 121-1; ETSI TS 136 521-1; 3GPP TS 36 521-1; AS/NZS AS/NZS 4295; AS/NZS 4268; RSS-102; RSS-102.NS.MEAS; SPR-002; EN 62479; IEC 62479; BS EN 62479; EN 50385; BS EN 50385; EN 50663; BS EN 50663; EN 62311; IEC 62311; EN 50665; BS EN 50665; BS EN IEC 62311; AS/NZS 2772.2--
4EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ANSI C63.4-2014; FCC MP-5 (February 1986); ANSI C63.10-2013; ANSI C63.10-2020; KDB 905462 D02 (v02); ANSI C63.26:2015; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E-to 40000 MHz
547 Code of Federal Regulations; FCC KDB 974614--
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited GUANGDONG GLOBAL TESTING TECHNOLOGY CO., LTD. Dongguan, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 24th of April 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6947.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.