Technical Maintenance, Inc. - WHITE

3660 Highway 411 N.E., 30184, White, GA, United States

Visit website
A2LA 2348.10ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 2348.10 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-to 300 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

Page 2 of 5 (A2LA Cert. No. 2348.10) 06/25/2026 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comment DC Voltage – Generate (0 to 329.999) mV 330 mV to 3.299 99 V (3.3 to 32.999 9) V (33 to 329.999) V (330 to 1020) V 0.028 % of rdg + 10 µV 0.013 % of rdg + 15 µV 0.016 % of rdg + 150 µV 0.015 % of rdg + 1.5 mV 0.015 % of rdg + 5.5 mV Fluke 5080A DC Voltage – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 0.0076 % of rdg + 3.5 µV 0.0058 % of rdg + 7 µV 0.0051 % of rdg + 50 µV 0.0064 % of rdg + 600 µV 0.0056 % of rdg + 10 mV Fluke 8845A DC Current – Generate (0 to 329.99) µA (0.330 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.999) mA 330 mA to 1.0999 A (1.1 to 2.999 9) A (3 to 10.999) A (11 to 20.5) A (20.5 to 150) A (150 to 1050) A 0.1 % of rdg + 0.1 µA 0.095 % of rdg + 0.25 µA 0.083 % of rdg + 1.25 µA 0.1 % of rdg + 16.5 µA 0.18 % of rdg + 220 µA 0.19 % of rdg + 220 µA 0.29 % of rdg + 2.5 mA 0.58 % of rdg + 3.8 mA 0.44 % of rdg + 0.14 A 0.55 % of rdg + 0.14 A Fluke 5080A Fluke 5080A, 5500A/coil x50 Resistance – Generate 0 Ω 100 Ω 1000 Ω 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1000 MΩ 0.014 Ω 0.049 % of rdg 0.029 % of rdg 0.029 % of rdg 0.044 % of rdg 0.11 % of rdg 0.12 % of rdg 1 % of rdg 1 % of rdg Fluke 5080A Tsuruga 5804 resistor AC Voltage – Generate 45 Hz to 1 kHz (1 to 32.99) mV (33 to 329.99) mV 330 mV to 3.299 9 V (3.3 to 32.999) V (33 to 101.99) V (102 to 329.99) V (330 to 1020) V 0.42 % of rdg + 60 µV 0.2 % of rdg + 60 µV 0.15 % of rdg + 180 µV 0.16 % of rdg + 1.8 mV 0.19 % of rdg + 18 mV 0.19 % of rdg + 18 mV 0.2 % of rdg + 180 mV Fluke 5080A
3

Extracted from the scope document; tables may not line up. View scope for the original.

Page 3 of 5 (A2LA Cert. No. 2348.10) 06/25/2026 Parameter/Range Frequency CMC2, 3 (±) Comment AC Voltage – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 750) V 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.12 % of rdg + 0.04 mV 0.19 % of rdg + 0.05 mV 0.79 % of rdg + 0.08 mV 4.8 % of rdg + 0.5 mV 0.13 % of rdg + 0.3 mV 0.18 % of rdg + 0.5 mV 0.74 % of rdg + 0.8 mV 4.7 % of rdg + 5 mV 0.12 % of rdg + 3 mV 0.18 % of rdg + 5 mV 0.74 % of rdg + 8 mV 4.7 % of rdg + 50 mV 0.12 % of rdg + 30 mV 0.18 % of rdg + 50 mV 0.74 % of rdg + 80 mV 4.7 % of rdg + 500 mV 0.12 % of rdg + 0.3 V 0.18 % of rdg + 0.5 V 0.74 % of rdg + 0.8 V 4.7 % of rdg + 5 V Fluke 8845A AC Current – Generate 45 Hz to 1 kHz (45 to 65) Hz (65 to 440) Hz (29 to 329.9) µA 330 µA to 3.299 9 mA (3.3 to 32.999) mA (33 to 329.99) mA 330 mA to 1.099 9 A (1.1 to 2.999 9) A (3 to 10.999) A (11 to 20.5) A (20.5 to 1000) A 0.31 % of rdg + 0.75 µA 0.27 % of rdg + 0.9 µA 0.23 % of rdg + 12 µA 0.32 % of rdg + 120 µA 0.28 % of rdg + 1.2 mA 0.33 % of rdg + 1.5 mA 0.47 % of rdg + 6 mA 0.8 % of rdg + 15 mA 0.57 % of rdg + 1 A 0.86 % of rdg + 0.98 A Fluke 5080A Fluke 5080A, 5500A/coil x50
4

Extracted from the scope document; tables may not line up. View scope for the original.

Page 4 of 5 (A2LA Cert. No. 2348.10) 06/25/2026 Parameter/Equipment Range CMC2 (±) Comment Electrical Simulation of Thermocouple Indicators – Type J (-200 to 0) °C (0 to 1200) °C 1.2 °C 0.83 °C Fluke 725 Electrical Simulation of RTD Indicators – Pt100-385 Pt100-392 (0 to 200) °C (0 to 200) °C 0.39 °C 0.36 °C Fluke 725 III. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comment Scales & Balances (0.1 to 250) kg 9 g + 0.6R Class F weights Pressure Up to 100 psi Up to 689 kPa Up to 300 psi Up to 2068 kPa Up to 1000 psi Up to 6895 kPa Up to 10 000 psi Up to 68 948 kPa 0.09 psi 0.62 kPa 0.22 psi 1.5 kPa 10 psi 69 kPa 10 psi 69 kPa Fluke 700P06 Fluke 700P27 Fluke 700P08 Fluke 700P31
5-RTD; Thermocouple; Frequency
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Page 5 of 5 (A2LA Cert. No. 2348.10) 06/25/2026 IV. Thermodynamics Parameter Range CMC2, 6 (±) Comment RTD – Measure Pt100-385 Pt100-3926 (0 to 200) °C (0 to 200) °C 0.39 °C 0.36 °C Fluke 725 Thermocouple – Measure Type J (50 to 105) °C 1.2 °C Fluke 725, Fluke 9140 dry block V. Time & Frequency Parameter Range CMC2 (±) Comment Frequency (45 to 119.99) Hz (120 to 1000) Hz 0.017 % of rdg + 2 mHz 0.16 % of rdg + 2 mHz Fluke 5080A ____________________________________________________________ 1 This laboratory does not offer commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 In the statement of CMC, R is the numerical value of the resolution of the device under test in microinches. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
See scope document
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3660 Highway 411 N.E., White, GA, 30184, US

34.63226, -83.75960

Open in Maps

Other Locations

1 other site in this organization