SoWiTec development
Löherstraße 24, 72820, Sonnenbühl, Germany
- Accredited standards
- 6
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 6 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
IEC 61400-1
IEC 61400-12-1
IEC 61400-50-1
IEC 61400-50-2
IEC 61724-1
ISO 9613-2Acoustics - Attenuation of sound during propagation outdoors - Part 2: Engineering method for the prediction of sound pressure levels outdoors
IEC 61400-1; IEC 61400-12-1; FGW TR 6; IEC 61400-50; IEC 61400-50-1; IEC 61400-50-2; FGW TR5
ISO 9613-2; TA Noise; LAI; IEC 61724-1; VDI 3786 Bl. 1; VDI 3786 Bl. 5; WMO -No. 8; HV_SFA; HV_SRM
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-20107-01-00
Accredited scope, certificate D-PL-20107-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001; DIN EN ISO/IEC 17011 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-20107-01-01
Accredited scope, certificate D-PL-20107-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | - | wind; wind turbines; photovoltaic systemsShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-PL-20107-01-01
Valid from : 14.01.2026
Date of issue : 14.01.2026 page 2 of 5
Content
1 implementation, evaluation and analysis of wind m easurements with remote measurement
methods (SoDAR and LiDAR) and wind measuring masts / meteorological measuring equipment
[Flex A] ............................................................................................................................................... 3
2 determination of wind potential and energy yields of wind turbines;
determination of site quality [Flex A] ................................................................................................ 3
3 preparation of noise immission forecasts for wind turbines ............................................................ 4
4 preparation of shadow impact forecasts for wind t urbines ............................................................. 4
5 implementation, evaluation and analysis of global radiation measurements ................................. 4
6 determination of the irradiation potential and yi eld estimation for photovoltaic systems ............. 5
Flexible scope of accreditation:
The testing laboratory is permitted to use the standardized or equivalent test methods marked with
[Flex A] with different issue statuses without the need for prior information and approval from
DAkkS (flexible accreditation according to category A).
The testing laboratory has a current list of all test methods in the flexible accreditation area. The list
is publicly available on the website of the testing laboratory. | - |
| 3 | IEC 61400-1; IEC 61400-12-1; FGW TR 6; IEC 61400-50; IEC 61400-50-1; IEC 61400-50-2; FGW TR5 | wind measurements; wind turbines | - |
| 4 | ISO 9613-2; TA Noise; LAI; IEC 61724-1; VDI 3786 Bl. 1; VDI 3786 Bl. 5; WMO -No. 8; HV_SFA; HV_SRM | - | - |
| 5 | HV_SRA; HV_AEP_PV | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- DIgSILENT GmbH Prüflabor für NAR-KonformitätGomaringen · ~9 kmDAKKSShares 1 accredited test methodEN ISO 9001
- 4base lab AG advanced molecular analysisReutlingen · ~12 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Eurofins Institut JägerTübingen · ~14 kmDAKKSShares 1 accredited test methodEN ISO 9001
- ap-qualifizierungReutlingen · ~15 kmDAKKSShares 1 accredited test methodEN ISO 9001
- MG-ZfPSt. Johann · ~17 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.