TÜV SÜD Product Service
Daimlerstraße 40, 60314, Frankfurt am Main, Germany
Visit website- Accredited standards
- 3
- DAKKS certificates
- 2
- Sites in our directory
- 8
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 10993-1Biological evaluation of medical devices - Part 1: Requirements and general principles for the evaluation of biological safety within a risk management process
ISO 10993-12Biological evaluation of medical devices - Part 12: Sample preparation and reference materials
ISO 10993-18Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process
DIN EN ISO 10993-18; DIN EN ISO 10993-1; DIN EN ISO 10993-12
DIN EN ISO 10993-1; DIN EN ISO 10993-12; DIN EN ISO 10993-18; SOP A; SOP B; SOP C; SOP D; SOP E
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-11321-21-00
Accredited scope, certificate D-PL-11321-21-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Medizinprodukten | - |
| 2 | DIN EN ISO 10993-18; DIN EN ISO 10993-1; DIN EN ISO 10993-12 | Medizinprodukte, Biomaterialien | - |
| 3 | DIN EN ISO 10993-1; DIN EN ISO 10993-12; DIN EN ISO 10993-18; SOP A; SOP B; SOP C; SOP D; SOP E | Medizinprodukten; Werkstoffen für Medizinprodukte | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-11321-21-01
Gültig ab: 14.10.2026
Ausstellungsdatum: 14. 10.2026 Seite 4 von 4
Abkürzungen
DIN Deutsches Institut für Normung
EN Europäische Norm
GC Gaschromatographie
HS Headspace
ICP Induktiv gekoppeltes Plasma
ISO International Organization for Standardization
LC Flüssigchromatographie
MS Massenspektrometrie
Q-TOF Quadrupol -Flugzeit -Massenspektrometer
SOP
Standard Arbeitsanweisung der
TÜV SÜD Product Service GmbH | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-11321-21-01
Accredited scope, certificate D-PL-11321-21-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Medizinprodukten | - |
| 2 | DIN EN ISO 10993-18; DIN EN ISO 10993-1; DIN EN ISO 10993-12 | Medizinprodukte, Biomaterialien | - |
| 3 | DIN EN ISO 10993-1; DIN EN ISO 10993-12; DIN EN ISO 10993-18; SOP A; SOP B; SOP C; SOP D; SOP E | Medizinprodukten; Werkstoffen für Medizinprodukte | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-11321-21-01
Gültig ab: 14.10.2026
Ausstellungsdatum: 14. 10.2026 Seite 4 von 4
Abkürzungen
DIN Deutsches Institut für Normung
EN Europäische Norm
GC Gaschromatographie
HS Headspace
ICP Induktiv gekoppeltes Plasma
ISO International Organization for Standardization
LC Flüssigchromatographie
MS Massenspektrometrie
Q-TOF Quadrupol -Flugzeit -Massenspektrometer
SOP
Standard Arbeitsanweisung der
TÜV SÜD Product Service GmbH | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
7 other sites in this organization
Labs with overlapping accredited scope in Germany
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.