TestEquity
1935 Plaza Real, 92056, Oceanside, CA, United States
Visit website- Scope lines
- 7
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 3159.01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3159.01) 06/03/2025 Page 2 of 6
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(cont)
(22 to 220) mA
220 mA to 2.2 A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
61 µA
40 µA
28 µA
50 µA
0.25 mA
0.59 mA
1.1 mA
16 mA
Fluke 5730A
AC Current – Measure
Up to 100 µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
0.43 µA
0.18 µA
0.091 µA
0.091 µA
4.2 µA
1.7 µA
0.80 µA
0.51 µA
0.80 µA
42 µA
17 µA
8.1 µA
5.1 µA
8.1 µA
0.42 mA
0.17 mA
81 µA
51 µA
81 µA
4.2 mA
1.8 mA
1.0 mA
1.2 mA
3.2 mA
Agilent 3458A,
option 002 | to 1 A |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3159.01) 06/03/2025 Page 3 of 6
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
4.6 µV
4.7 µV
4.2 µV
4.4 µV
6.1 µV
12 µV
25 µV
27 µV
11 µV
6.3 µV
6.0 µV
8.6 µV
15 µV
32 µV
49 µV
0.086 mV
62 µV
28 µV
19 µV
34 µV
0.082 mV
0.17 mV
0.31 mV
0.63 mV
0.52 mV
0.21 mV
0.10 mV
0.16 mV
0.21 mV
0.79 mV
2.2 mV
4.1 mV
5.3 mV
2.1 mV
0.93 mV
1.5 mV
1.9 mV
5.8 mV
23 mV
40 mV
Fluke 5730A | to 2.2 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3159.01) 06/03/2025 Page 4 of 6
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(cont)
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(15 to 50) Hz
50 Hz to 1 kHz
54 mV
20 mV
12 mV
18 mV
34 mV
0.35 V
0.12 V
Fluke 5730A
AC Voltage – Measure
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
24 µV
10 µV
18 µV
33 µV
90 µV
0.31 mV
1.0 mV
0.12 mV
0.096 mV
0.17 mV
0.33 mV
0.84 mV
3.1 mV
10 mV
1.1 mV
0.95 mV
1.7 mV
3.3 mV
8.3 mV
31 mV
0.10 V
25 mV
22 mV
24 mV
39 mV
0.12 V
Agilent 3458A,
option 002 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3159.01) 06/03/2025 Page 5 of 6
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Current – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
15 nA
87 nA
0.84 µA
11 µA
0.20 mA
Fluke 5730A
DC Current – Measure
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
3.6 nA
32 nA
0.33 µA
5.1 µA
0.13 mA
Agilent 3458A,
option 002
DC Voltage – Generate
(0 to 0.22) V
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
2.1 µV
12 µV
43 µV
85 µV
1.1 mV
7.8 mV
Fluke 5730A
DC Voltage – Measure
0 V to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
1.1 µV
6.5 µV
62 µV
0.84 mV
9.7 mV
Agilent 3458A,
option 002
DC Resistance – Generate,
Fixed Points
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
43 µΩ
98 µΩ
0.18 mΩ
0.25 mΩ
0.46 mΩ
1.0 mΩ
2.0 mΩ
6.8 mΩ
13 mΩ
67 mΩ
0.13 Ω
0.88 Ω
Fluke 5730A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3159.01) 06/03/2025 Page 6 of 6
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Resistance – Generate,
Fixed Points (cont)
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1.7 Ω
14 Ω
36 Ω
0.43 kΩ
0.95 kΩ
11 kΩ
Fluke 5730A
DC Resistance – Measure
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
0.24 mΩ
2.0 mΩ
14 mΩ
0.14 Ω
1.4 Ω
21 Ω
0.68 kΩ
55 kΩ
Agilent 3458A,
option 002
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eithe r a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 7 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Molecular BioProducts d.b.a. Unity Lab ServicesCarlsbad, CA · ~11 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Fred V. Fowler Company LLC DBA Anko Electronics Test & MeasurementVista, CA · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Spektra Labs by APS DynamicsSan Juan Capistrano, CA · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Flagship Lab ServicesSan Diego, CA · ~57 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GL TechnologiesSan Diego, CA · ~57 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994