Spektra Labs by APS Dynamics

San Juan Capistrano, CA, United States

Visit website
A2LA 2405.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 2405.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994Accelerometers; Velocity Sensors; Vibration Meters; Vibration Calibrators; Vibration Displacement Sensors; Vibration Controllers; Portable Shakers-
2-Accelerometers
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2405.01) 02/05/2026 Page 2 of 3 Parameter/Range Frequency3, 4 CMC2, 5 (±) Comments Accelerometers (Secondary) – Charge (Charge Amplifier) (0.1 to 10 000) pC 0.2 Hz to 20 kHz (>20 to 50) kHz 0.26 %/0.6° 1.1 %/1.1° Internal comparison method, SPEKTRA CS18 w/ phase Accelerometers (Secondary) – Voltage (Measuring Amplifier) 1.0 mV to 30 V 0.2 Hz to 20 kHz (>20 to 50) kHz 0.26 %/0.6° 1.1 %/1.1° Internal comparison method, SPEKTRA CS18 w/ phase Accelerometers – Sensitivity/Frequency Response (1 to 3) g n (0.25 to 10) g n (1 to 100) Hz (10 to <100) Hz (100 Hz to >2.5 kHz (>2.5 to 10) kHz (>10 to 15) kHz 2.3 % 1.5 % 1.2 % 2.0 % 3.4 % Comparison method, Endevco 68357, APS dynamics long stroke shaker Comparison method, Endevco 68357, Bouche shaker Parameter/Equipment Range3, 4 CMC2, 5 (±) Comments Accelerometers3– Shock Amplitude (20 to 2000) g n (>2000 to 10 000) gn 1.7 % 2.7 % Comparison method, Endevco 2925 POP system
-
3-Microphones; Sound Level Meters; Acoustic Calibrators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2405.01) 02/05/2026 Page 3 of 3 ________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 gn is the standard gravitational acceleration due to gravity. 4 For sinusoidal excitation and narrow -band evaluation, the amplitudes of vibration acceleration, velocity and displacement are unambiguously linked to one another by the vibration frequency; therefore, velocity and displacement sensors are calibrated using the measurand acceleration and frequency, as stated in the table. 5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7APS Dynamics, Inc. is the legal entity doing business as Spektra Labs (formally known as Precision Labs). Parameter/Range Frequency4 CMC2 (±) Comments Acoustics – Sound Pressure Level Microphones (84 to 114) dB Sound Level Meters (84 to 114) dB Sound Pressure Level (94 to 114) dB (Microphones, Sound Level Meters, Acoustic Calibrators) 31.5 Hz to 5 kHz (5.0 to 10) kHz (10.0 to 16) kHz 31.5 Hz to 5 kHz (5.0 to 10) kHz (10.0 to 16) kHz 1000 Hz 0.20 dB 0.25 dB 0.50 dB 0.20 dB 0.25 dB 0.50 dB 0.20 dB Comparison method, SPEKTRA CS18AK w/ acoustic coupler Comparison method, SPEKTRA CS18AK w/ acoustic coupler Substitution method, SPEKTRA CS18AK w/ reference microphone and reference calibrator
84 to 114 dB
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.