Spektra Labs by APS Dynamics
San Juan Capistrano, CA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2405.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | Accelerometers; Velocity Sensors; Vibration Meters; Vibration Calibrators; Vibration Displacement Sensors; Vibration Controllers; Portable Shakers | - |
| 2 | - | AccelerometersShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2405.01) 02/05/2026 Page 2 of 3
Parameter/Range
Frequency3, 4
CMC2, 5 (±)
Comments
Accelerometers (Secondary) –
Charge
(Charge Amplifier)
(0.1 to 10 000) pC
0.2 Hz to 20 kHz
(>20 to 50) kHz
0.26 %/0.6°
1.1 %/1.1°
Internal comparison
method, SPEKTRA
CS18 w/ phase
Accelerometers (Secondary) –
Voltage
(Measuring Amplifier)
1.0 mV to 30 V
0.2 Hz to 20 kHz
(>20 to 50) kHz
0.26 %/0.6°
1.1 %/1.1°
Internal comparison
method, SPEKTRA
CS18 w/ phase
Accelerometers –
Sensitivity/Frequency
Response
(1 to 3) g
n
(0.25 to 10) g
n
(1 to 100) Hz
(10 to <100) Hz
(100 Hz to >2.5 kHz
(>2.5 to 10) kHz
(>10 to 15) kHz
2.3 %
1.5 %
1.2 %
2.0 %
3.4 %
Comparison method,
Endevco 68357, APS
dynamics long stroke
shaker
Comparison method,
Endevco 68357,
Bouche shaker
Parameter/Equipment
Range3, 4
CMC2, 5 (±)
Comments
Accelerometers3–
Shock Amplitude
(20 to 2000) g
n
(>2000 to 10 000) gn
1.7 %
2.7 %
Comparison method,
Endevco 2925 POP
system | - |
| 3 | - | Microphones; Sound Level Meters; Acoustic CalibratorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2405.01) 02/05/2026 Page 3 of 3
________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 gn is the standard gravitational acceleration due to gravity.
4 For sinusoidal excitation and narrow -band evaluation, the amplitudes of vibration acceleration, velocity
and displacement are unambiguously linked to one another by the vibration frequency; therefore, velocity
and displacement sensors are calibrated using the measurand acceleration and frequency, as stated in the
table.
5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7APS Dynamics, Inc. is the legal entity doing business as Spektra Labs (formally known as Precision Labs).
Parameter/Range
Frequency4
CMC2 (±)
Comments
Acoustics –
Sound Pressure Level
Microphones
(84 to 114) dB
Sound Level Meters
(84 to 114) dB
Sound Pressure Level
(94 to 114) dB
(Microphones,
Sound Level
Meters, Acoustic
Calibrators)
31.5 Hz to 5 kHz
(5.0 to 10) kHz
(10.0 to 16) kHz
31.5 Hz to 5 kHz
(5.0 to 10) kHz
(10.0 to 16) kHz
1000 Hz
0.20 dB
0.25 dB
0.50 dB
0.20 dB
0.25 dB
0.50 dB
0.20 dB
Comparison method,
SPEKTRA CS18AK
w/
acoustic coupler
Comparison method,
SPEKTRA CS18AK
w/
acoustic coupler
Substitution method,
SPEKTRA CS18AK
w/
reference microphone
and reference
calibrator | 84 to 114 dB |
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- FLW Service CorporationHuntington Beach, CA · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Anko ElectronicsAnaheim, CA · ~44 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RSA Industries Inc dba American GagePlacentia, CA · ~45 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Element U.S. Space & DefenseFullerton, CA · ~48 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Fred V. Fowler Company LLC DBA Anko Electronics Test & MeasurementVista, CA · ~51 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.